HomeMy WebLinkAboutB14-0224_E5.1_1415134560.pdf 041F le 4;44.4,Aplici. L I OHTI NO CONTROL GENERAL NOTES LIGHTING FIXTURE SCHEDULE PANEL 1P-12' TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTAGE LAMP MAX MOUNTING INFORMATION NOTES VOLTAGE L-L: 208 LOCATION: ELECTRICAL ROOM Z 11 QTY WATT TYPE WATTS LOCATION BOF/RFD/OFH VOLTAGE L-G: 120 BUS RATING: 400A I. L16HTINO CONTROL SYSTEM SHALL BE DIGITAL AND CONSIST OF A MASTER LGP WITH UP TO 48DI 6" LED DOWNLIGHT, 3500KELVIN, PRESCOLITE D6LED3-DM-6DgLED3-35K- 120 I 14 LED 14 RECESSED 1-1/4" TYPE: 3PH/4W MAIN GB: M.L.O. INDIVIDUAL RELAYS, AND A SLAVE LGP WITH UP TO 48 INDIVIDUAL RELAYS IN EACH PANEL, DIGITAL MOUNTING: SURFACE S.G. RATING: 42K AIG FULLY RATED WHITE REFLECTOR,WHITE TRIM FL35-MFG-WH-WT CEILING RFD SWITCHES AND DIGITAL INTERFACE CARDS. EACH RELAY SHALL BE SWITCHABLE OR O-IOVDC 35 DEGREE BEAM ANGLE NOTES: PROVIDE (2) 60-GKT SECTIONS FED FROM: MDP(VIA 400A/3P) DIMMABLE. ALL SYSTEM COMPONENTS SHALL GONNEGT IN A "DAISY CHAIN" STYLE CONFIGURATION DIEM 6" LED DOWNLIGHT,3500KELVIN, PRESCOLITE D6LED3-DM-6D4LED3-35K- 120 I 14 LED 14 RECESSED 1-I/4" I AND BE CONTROLLED VIA CATEGORY 5 PATCH GABLE WITH RJ45 GONNEGTORS, PROVIDING WHITE REFLECTOR,WHITE TRIM FL35-MFG-HH-WT CEILING RFD CIR. GGT LOAD LOAD GIRGUIT BRKR BUS CIRCUIT BRKR LOAD LOAD GGT GIR 411111)1 I tfPlani ib REAL-TIME TWO-WAY COMMUNICATION WITH EACH SYSTEM COMPONENT. ANALOG SYSTEMS ARE NOT 35 DEGREE BEAM ANGLE NO TYPE VA DESCRIPTION POLE TRIP TRIP POLE DESCRIPTION VA TYPE NO ACCEPTABLE. ALL GABLES SUPPLIED BY GONTRAGTOR. PROVIDE REMOTE EM INVERTER DLE: LG2S I EXISTING LOAD * * A * * EXISTING LOAD 2 Fl 4' FLUORESCENT WRAP COLUMBIA PT-4'-2-32-E-U 120 2 28 T8 56 SURFACE 4-13/16" 3 EXISTING LOAD * * B * * EXISTING LOAD 4 2. RELAY PANELS SHALL BE PRE-WIRED, PRE-ASSEMBLED, PREPROGRAMMED AND LISTED TO UL 416 ELECTRONIC BALLAST CEILING OFH 5 EXISTING LOAD * * G * * EXISTING LOAD 6 (NORMAL) OR ETL LISTED TO UL424 (EMERGENCY). PANELS SHALL BE PROVIDED WITH DUAL VOLTAGE 1 EXISTING LOAD * * A * * EXISTING LOAD 8 11/04/14 POWER SUPPLY AND 16 GAGE BARRIERS TO SEPARATE HIGH AND LOW VOLTAGE, NORMAL AND FIEM 4' FLUORESCENT WRAP COLUMBIA PT-4'-2-32-E-U-EL 120 2 28 T8 56 SURFACE 4-13/16" _ 4 EXISTING LOAD * * B * * EXISTING LOAD 10 EMERGENCY POWER. ELEGTRONIG BALLAST CEILING OFH II EXISTING LOAD * * G * * EXISTING LOAD 12 EMERGENCY BATTERY PACK 13 EXISTING LOAD * * A * * EXISTING LOAD 14 3. ELECTRICAL CONTRACTOR SHALL COORDINATE PRE-PROGRAMMING SCHEDULE OF OPERATION WITH F2EM 2' FLUORESCENT WRAP COLUMBIA PT-2'-2-I1-E-U-EL 120 2 Il T8 31 SURFACE 4-13/16" 15 EXISTING LOAD * * B * * EXISTING LOAD 16 OWNER PRIOR TO PREPARING SUBMITTALS. ELECTRONIC BALLAST WALL OFH Il EXISTING LOAD * * G * * EXISTING LOAD 18 I '7 Malle� iU , 1 '1 EMERGENCY BATTERY PACK 14 EXISTING LOAD * * A * * EXISTING LOAD 20 1 -_IIN rY F3 4' FLUORESCENT STRIP COLUMBIA CS-4'-2-32-EP-U 120 2 28 T8 56 SURFACE 2-11/16" 21 EXISTING LOAD * * B * * EXISTING LOAD 22 „ 4. STANDARD RELAYS SHALL HAVE NORMALLY CLOSED (NG) GONTAGTS RATED FOR 120/2TJV 20A PROGRAMMED START BALLAST CEILING OFH 23 EXISTING LOAD * * G * * EXISTING LOAD 24 � '1`'' Q TUNGSTEN, BALLAST OR HID. STANDARD RELAYS SHALL BE ZERO-GROSS TYPE. NO EXCEPTIONS. 25 EXISTING LOAD * * A * * EXISTING LOAD 26 OPTIONAL 600V, 2-POLE RELAY, NO OR NC, AND 341 SINGLE POLE RELAY SHALL BE AVAILABLE. F3EM 4' FLUORESCENT STRIP COLUMBIA CS-4'-2-32-EP-U-EL 120 2 28 TS 56 SURFACE 2-11/16" 21 EXISTING LOAD * * B * * EXISTING LOAD 28 PROGRAMMED START BALLAST CEILING OFH 24 EXISTING LOAD * * G * * EXISTING LOAD 30 *��.�. 5. ALL INCANDESCENT LIGHTING CIRCUITS SHALL BE CONTROLLED BY A NG/SOFTSTART RELAY. NO _EMERGENCY BATTERTY PACK 31 EXISTING LOAD * * A * * EXISTING LOAD 32 4•••••� R "*•.,• EXCEPTIONS. PI DECORATIVE PENDANT TBD 120 I 140 LED 140 PENDANT 2 33 EXISTING LOAD * * B * * EXISTING LOAD 34 �, . G/S•�•• CEILING 35 EXISTING LOAD * * G * * EXISTING LOAD 36 �4,4' . i• 6. RELAY PANEL ELECTRONICS SHALL PROVIDE CURRENT VISUAL STATUS AND CONTROL OF EACH RELAY 31 EXISTING LOAD * * A * * EXISTING LOAD 38 ** io �/ '.0* OR ZONE. ALL SYSTEM CONTROL ELEGTRONIG5 SHALL STORE PROGRAMMING IN A NON-VOLATILE TI TRACK,VARIOUS LENGTHS TBD 120 I 30H LED 301"1 SURFACE 1,2,3 34 EXISTING LOAD * * B * * EXISTING LOAD 40 ' •i ;(,1 MEMORY AND PROVIDE 10 YEAR BATTERY BACK UP FOR TIME OF DAY. FT FT CEILING 41 EXISTING LOAD * * G * * EXISTING LOAD 42 ' V 58 7 ; 43 EXISTING LOAD * * A * * EXISTING LOAD 44 WI DECORATIVE WALL VANITY TBD 120 2 Il T8 31 SURFACE 2 45 EXISTING LOAD * * B * * EXISTING LOAD 46 - • Cr I 1. LIGHTING CONTROL SYSTEM SHALL CONSIST OF MASTER AND SLAVE PANEL(S) CONTROLLED BY A ../41/11 WALL 41 EXISTING LOAD * * G * * EXISTING LOAD 48 . (o 46'11' 32-CHANNEL DIGITAL TIME CLOCK (DTC) THAT CONTROLS AND PROGRAMS THE ENTIRE LIGHTING 4q EXISTING LOAD * * A * * EXISTING LOAD 50 / CONTROL SYSTEM. THE DTG SHALL SUPPLY ALL TIME FUNCTIONS AND ACCEPT OTHER INPUTS. THE DTG 51 EXISTING LOAD * * B * * EXISTING LOAD 52 , ,"" : :•• SHALL AGGEPT CONTROL LOCALLY USING BUILT IN BUTTON PROMPTS AND USE OF AN 8 LINE 21-LETTER YI RECESSED EMERGENCY FIXTURE GONGEALITE F5000-LED45-40 120 2 3 LED 6 RECESSED 2 * * * * �l•.SS'��WI- ...*• CEILING 53 EXISTING LOAD G EXISTING LOAD 54 •.••••„**!*�***• DISPLAY, FROM A COMPUTER, MODEM, ETHERNET OR INTERNET. ALL COMMANDS SHALL BE IN PLAIN 55 EXISTING LOAD * * A * * EXISTING LOAD 56 ENGLISH. HELP PAGES SHALL DISPLAY ON THE DTG SCREEN. XI LED EDGE LIT EXIT SIGN, DUAL LITE LES-X-S-G-N 120 I 2.5 LED 2.5 SURFACE 51 EXISTING LOAD * * B * * EXISTING LOAD 58 GREEN LETTERS CEILING 54 EXISTING LOAD * * G * * EXISTING LOAD 60 8. ALL SWITCHES SHALL COMMUNICATE VIA RS 485, GAT 5 PATCH GABLE WITH RJ45 CONNECTORS. 61 M 108 P-I,B-I I 20 A 20 I LOWER LVL BATHROOM 120 R 62 CONTACT CLOSURE STYLE SWITCHES ARE NOT ACCEPTABLE. ANY SWITCH BUTTON FUNCTION SHALL BE ABBREVIATIONS: BOF - BOTTOM OF FIXTURE,RFD - RECESSED FIXTURE DEPTH,OFH - OVERALL FIXTURE HEIGHT 63 M 108 P-2,B-2 I 20 B 20 I SPARE 1116 M 64 ABLE TO BE CHANGED LOCALLY (AT THE DTC OR A PG) OR REMOTELY, VIA MODEM, ETHERNET OR GENERAL NOTES: 65 M 108 P-3,B-3 I 20 G 20 I LOWER LVL ELEC.RM RCPT 400 R 66 INTERNET. REFER TO SINGLE LINE DIAGRAM FOR WIRING DETAILS. SWITCHES WHICH CANNOT BE A. ALL FLUORESCENT LAMPS TO BE 3500K COLOR TEMPERATURE ANDA MINIMUM OF 82GR1,UNLESS NOTED OTHERWISE. 61 LM 1116 P-50 I 20 A 20 I MAIN LVL POS 180 E 68 PROGRAMMED REMOTELY SHALL NOT BE ACCEPTABLE. B. ALL REFLECTOR LAMPS TO BE PROVIDED AS WIDE FLOOD DISTRIBUTION,UNLESS NOTED OTHERWISE. 6q M 1116 P-5b I 20 B 20 I LOWER LVL MERGH 1080 R 10 G. ALL FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE-ENDED LAMPS AND CONTAIN BALLASTS THAT GAN BE SERVICED IN PLACE SHALL HAVE A 11 M 1116 P-4,WH-I,P-6 I 20 G 20 I ELEV PIT LT6 RCPT 244 L 12 q. START UP: EC SHALL GONTAGT MANUFACTURER AT LEAST 1 DAYS BEFORE TURNOVER OF PROJECT. DISCONNECTING MEANS AS DESCRIBED IN NEC 410.130(G). 13 M 1342 EVR-I,EVR-2 I 20 A 20 I ELEV EQUIP LT6 RCPT 244 L 14 MANUFACTURER SHALL REMOTELY DIAL INTO THE LIGHTING CONTROL SYSTEM, RUN DIAGNOSTICS AND 15 M 25q.5 EF-I,SF-I,GUH-I I 20 B 20 I SPARE 16 N. CONFIRM SYSTEM PROGRAMMING. EG SHALL BE AVAILABLE AT THE TIME OF DIAL IN TO PERFORM SPECIFIC NOTES: TI E 1144 GU-I,FG-I 2 20 G 20 I SPARE 18 LPl ANY CORRECTIONS REQUIRED BY LGSD. EG IS RESPONSIBLE FOR COORDINATING WITH 6G AND THE I. COORDINATE DRIVER, INVERTER OR TRANSFORMER LOCATION WITH ARCHITECT PRIOR TO INSTALLATION 1g E 1144 -- -- -- A 20 I MAIN LVL MERCHANDISE 400 R 80 OWNER, THE INSTALLATION OF A DEDICATED TELEPHONE LINE OR A SHARED PHONE LINE WITH A/B 2. COORDINATE MOUNTING HEIGHT AND DETAILS HITH ARCHITECT PRIOR TO INSTALLATION 81 M 1116 SP-I I 20 B 20 I MAIN LVL MERCHANDISE 1080 R 82 L 3. PROVIDE ALL PARTS AND COMPONENTS NECESSARY FOR ENERGIZING LUMINAIRES 83 L 261 2ND LVL GENERAL LT6 I 20 G 20 I LOWER LVL DATA RM REGEP 180 R 84 ll— SWITCH. PHONE JACK TO BE MOUNTED WITHIN 12 OF MASTER LGP. LABEL JACK WITH PHONE NUMBER. 85 L 1400 2ND LVL TRACK 1 20 A 20 1 SPARE 86 00 EG SHALL GONNEGT PHONE LINE FROM JACK TO MASTER LGP. NO EXCEPTIONS. 4. PROVIDE REMOTE MOUNT EMERGENCY BALLAST, COORDINATE MOUNTING WITH ARCHITECT. 81 L 1260 LOWER LVL TRACK I 20 B 20 I SPARE 88 5. PROVIDE MOUNTING CHANNELS AND PARTS AS REQUIRED. CONFIRM WITH ARCHITECT 84 L 1680 LOWER LVL TRACK I 20 G 20 I 2ND LVL COMPRESSOR 1116 M 40 O 10. TELEPHONE FACTORY DIAL-UP SUPPORT SHALL BE AVAILABLE AT NO ADDITIONAL COST TO THE EG 41 L 1260 LOWER LVL TRACK I 20 A 20 I ELEV GAB LT6 200 L q2 OR OWNER BOTH DURING AND AFTER THE 3 YEAR WARRANTY PERIOD. FACTORY TO PREPROGRAM 43 L 1200 MAIN LVL MERGH TRACK I 20 B 20 I 2ND LVL GENERAL 180 R 44 U THE LIGHTING CONTROL SYSTEM PER PLANS AND APPROVED SUBMITTAL. THE LIGHTING CONTROL 45 L 280 1 20 G 20 I _2ND LVL GENERAL 180 R 46 LU MANUFACTURER, AT NO ADDED COST, SHALL PROVIDE ADDITIONAL PROGRAMMING VIA MODEM AS 41 L 1644 MAIN LVL MERGH LT6 I _ 20 A 20 I MAIN LVL 6EN LT6 111 L 48 1 Ce J REQUIRED BY THE EG OR OWNER FOR THE OPERATIONAL LIFE OF THE SYSTEM. MANUFACTURER 44 L 1680 MAIN LVL MERGH LT6 1 20 B 20 I ELEVATOR PIT REG 180 R 100 O WARRANTS THAT THE DTG SOFTWARE GAN BE UPGRADED AND MONITORED REMOTELY. NO 101 L 1680 MAIN LVL MERGH LT6 I 20 G 20 I ELEV EQUIP REG 180 R 102 EXCEPTIONS. 103 L 1120 MAIN LVL MERGH LT6 I 20 A 20 I FACP 100 E 104 UH > 105 L I 1400 MAIN LVL MERGH LT6 I 20 B 20 I TENANT TEMP LT6 340 L 106 V) II. SHOP DRAWINGS: SUBMIT DIMENSIONED DRAWINGS OF LIGHTING CONTROL SYSTEM AND ACCESSORIES 101 L 853 LOWER LVL GEN LT6 I 20 G 20 I GORR 6EN LT6 168 L 108w LJJ INCLUDING, BUT NOT NECESSARILY LIMITED TO, RELAY PANELS, SWITCHES, DTC, PHOTOCELLS AND 104 E 100 RELAY PANEL (RP-I) I 20 A 20 I SPARE 110 V > OTHER INTERFACES. DRAWINGS SHALL INDICATE EXACT LOCATION AND PROGRAMMING OF EACH III SPARE I 20 B 20 I SPARE 112 DEVICE. INDICATE ALL TIME SCHEDULES AND SWITCH BUTTON ENGRAVING. 113 SPARE I 20 G 20 I SPARE 114 LA J Fe 115 _ SPARE I 20 A 20 I SPARE 116 Q 111 SPARE I 20 B 20 I SPARE 118 Ce 12. APPROVED LIGHTING CONTROL SYSTEM TO BE BY LIGHTING CONTROLS DESIGN, LOS ANGELES, CA 114 SPARE I 20 G 20 I SPARE 120 J (500) 345-4445., OR APPROVED EQUAL BY LUTRON LIGHTING, OR WATT STOPPER. 0 >> \ GGT TYPE: L=LIGHTING,R=RECEPTACLE, M=MOTOR,LM=LARGEST MOTOR,E=EQUIPMENT,KE=KITGH EQUIP,S=SUBFEED PANEL w 13. BUILDING LIGHTING CONTROL SYSTEM SHALL INCLUDE A MINIMUM OF 4 HOURS OF MANUFACTURER'S MECHANICAL EQUIPMENT SCHEDULE GGT TYPE: LOAD MULT DEMANDED LOAD TOTAL CONNECTED LOADS J W REPRESENTATIVE TIME ON SITE FOR SYSTEM GHEGK-OUT AND OWNER TRAINING. ELECTRICAL KEY DESCRIPTION VOLTS PH LOAD MOGP/ FEEDER DISCONNECT GIRGUIT NOTES LIGHTING: 11141 1.25 21484 VA A B G U 47t CONTRACTOR SHALL VIDEO TAPE TRAINING SESSION AND PROVIDE COPY OF THAT VIDEO TO OWNER HP,W,A MFS RECEPTACLE: 5580 1.0 5580 VA VA 13165 12446 11460 AS PART OF PROJECT COMPLETION SUBMITTALS. FG-I FAN GO IL 208 1 1.0 A -- 2 4*12, 14*126, 3/4"C $TO VIA GU-I I OVER 10K: 0 0.5 0 VA TOTAL DEMANDED LOADS U MOTOR: 4656 1.0 4656 VA A B G > w GU-I CONDENSING UNIT 208 I 13.0 MCA 20 A/2P 2 #10, MOO, 3/4"C 30A/2P PI2-11,74 2 LOST MOTOR: 1116 1.25 1410 VA VA 14483 14428 12152 INDOOR MOGP FUSED EQUIPMENT: 3468 1.0 3468 VA AMPS 125 120 106 ce P-I BOILER PUMP(B-I) 120 I I/6 HP 20 A/IP 2 #12, I#126,3/4"G $TO PI2-61 KITGH EQUIP: 0 0 0 VA TOTAL ON 42 KVA O 4.4 FLA MOGP SUBFEED PNL: 0 1.0 0 VA PANEL: 111 AMPS u O P-2 BOILER PUMP(B-2) 120 I 1/6 HP 20 A/IP 2 #12, I#12G, 3/4"C $TO PI2-63 NOTES: 4.4 FLA MOGP * THE ELECTRICAL CONTRACTOR TO FIELD COORDINATE BRANG CIRCUIT BREAKER REQUIREMENTS. ALL BRANCH CIRCUITS Lrl 0 P 3 BOILER PUMP(B-3) 120 I 1/6 HP 20 A/IP 2 *12, I#126, 3/4"C $TO PI2 65 OF EXISTING PANELS PI, P12,HOUSE PANEL,SPRINKLER PANEL,AND SMALL BRANCH CIRCUITS OF PANEL MDP ARE TO BE _ 4.4 FLA MOGP RE-FED FROM THIS NEN PANEL. Lo O O LOCATOR LIGHT P-4 HATER HEATER PUMP (WH-I) 120 I 1/6 HP 20 NIP 2 *12, I#12G, 3/4"C $TO PI2-l1 NI 4.4 FLA MOGP 0 O P-5a SPACE HEATING PUMP 120 I 1/2 HP 20 NIP 2 *12, I#126,3/4"C $TO PI2-67 e ` e ` i ON LINE 4.8 FLA MOGP 2 LINES OF ...es INDICATOR ENGRAVING I I ,may P-5b SPACE HEATING PUMP 120 I I/2 HP 20 NIP 2 #12, I#126,3/4"G $TO PI2 64 Am.-.E _ 4.8 FLA MOGP O Q Q Q 8 CHARACTERS / p O 'mm+ P-6 HEAT EXCHANGER PUMP 120 I 1/6 HP 20 NIP 2 *12, I#12G, 3/4"G $TO PI2-l1 LINE ' I (HX-I) 4.4 FLA MOGP rJ rJ rJ rJ I I i I. B-I CENTRAL CONDENSING 120 I 1.5 A 20 NIP 2 #12, I#126, 3/4"G $TO PI2-61 SOUTH SOUTH NORTH EAST BOILER MOGP TRACK TRACK TRACK TRACK 2 RJ45 BUS PILOT LIGHT 0 D In.--= I B-2 CENTRAL CONDENSING 120 I 15 A 20 A/IP 2 #12, 1#126,3/4"G $TO PI2-63 ' I BOILER MOGP w 1— PUSH BUTTONS II CONNECTORS B-3 CENTRAL CONDENSING 120 I 1.5 A 20 NIP 2 *12, 1#126,3/4"C $TO PI2-65 I— " 0 0 ,, Ulm TERMINATOR BOILER MOGP Q o12I 1— M WH-I HATER HEATER 120 I 1.0 A 20 NIP 2 *12, I#126,3/4"G $TO PI2 71 6; SOUTH SOUTH SOUTH / — MOGP TRACK PENDANTS TRACK SP-I SUMP PUMP (ELEVATOR PIT) 120 I 1/2 HP 20 NIP 2 *12, 1#126,3/4"G $TO PI2-81 til 0 4.8 FLA MOGP Z Z Z 0_ 0 GUH-1 CABINET UNIT HEATER 120 1 1.0 A 20 NIP 2 *12, I#12G,3/4"G $TO PI2-15 MOGP 0 17 57 EF-I ELEVATOR ROOM EXHAUST 120 I 62 H 20 NIP 2 *12, 1#12G,3/4"G $TO PI2-15 d < CHELSEA TYPE DIGITAL SWITCH FAN MOGP EC E SF-I MECHANICAL ROOM EXHAUST 120 I 62 H 20 NIP 2 *12, 1#126,3/4"C $TO PI2-15 U ce w FAN MOGP w O SWITCH NOTES ERV-I ENERGY RECOVERY 120 I .2 HP 20 NIP 2 *12, 1#12G, 3/4"C $TO PI2-13 0 --- VENTILATOR 5.8 FLA MOGP _ U O ERV-2 ENERGY RECOVERY 120 I .2 HP 20 NIP 2 #12, 1#126, 3/4"C $TO PI2-13 I. LIGHTING CONTROL SYSTEM SHALL BE DIGITAL AND CONSIST OF A MASTER ' VENTILATOR 5.8 FLA MOGP I ; WITH SLAVE PANEL CONNECTION. SWITCH BUTTONS SHALL BE FACTORY ELEV ELEVATOR 208 3 25 HP 115A 3#2/O, I#6G, 2"C 200A/3P RE: ONE-LINE — ENGRAVED. I MOGP 150A FRN-R Q ( _%Ifi:1_ 1_iiiL w N O GENERAL NOEES: cC lilL 2. PUSH BUTTONS MAY CONTROL ANY RELAYS) IN ANY COMBINATION. A. REFER TO MEGHANIGAL PLANS FOR SPEGIFIG EQUIPMENT LOCATIONS AND REQUIREMENTS. / d � �/ B. PRIOR TO ROUGH-IN,COORDINATE ALL MECHANICAL EQUIPMENT POWER AND CONNECTION REQUIREMENTS HITH 0 0 UU 2 71- O 3. LED PILOT LIGHTS INDICATE STATUS. MEGHANIGAL CONTRACTOR'S FINAL SHOP DRAWINGS. 1- ww o N 'WS2' 'WS3' G. PROVIDE ALL 120V CONTROL HIRING,REFER TO SPECIFICATIONS FOR FURTHER CONTROL HIRING CLARIFICATION. N0 Q N N 4-BUTTON 3-BUTTON 4. SWITCH LINKED TO THE BLUE BOX DIGITAL BUS VIA GAT. 5 PATCH GABLE WIT D. EXTERIOR DISCONNECT SWITCHES ARE TO BE PROVIDED AS NEMA 3R EQUIPMENT UNLESS OTHERWISE NOTED. N Z Lp a #GH-4-WH-WH #GH-3-WH-WH RJ45 CONNECTORS. E. PROVIDE WEATHERPROOF 120 VOLT GFCI RECEPTACLES WITHIN 25' OF ALL ROOFTOP HEATING,VENTILATING,AND AIR Q w (n CONDITIONING EQUIPMENT. GIRGUIT TO SPARE CIRCUIT ON NEAREST 120V PANELBOARD OR AS INDICATED ON PLANS. Z F- F. FOR ANY BOILER MECHANICAL SYSTEM,E.G. IS TO PROVIDE AN EMERGENCY PUSHBUTTON OFF AND ANY CONTROL HIRING 5. PROVIDE KEY-ENABLE DIGITAL KEY SWITCH FOR LOCATIONS AS INDICATED. REQUIRED. COORDINATE EXACT REQUIREMENTS HITH MECHANICAL CONTRACTOR AND EQUIPMENT PRIOR TO INSTALLATION. ce CI) w 3 O vi O 6. DEGORA STYLE FACE PLATE BY CONTRACTOR. SPEGIFIG NOTES: a co I. FAN COIL FED BY CONDENSING UNIT,THE ELECTRICAL CONTRACTOR TO COORDINATE INTERLOCKING m Q ILtj a REQUIREMENTS WITH EQUIPMENT SHOP DRAWINGS.a) e 171 H m 2. PROVIDE FUSE PER EQUIPMENT NAMEPLATE. w 0 3 DIGITAL SWITCH DETAIL a _ U / 1 O E5.1 SCALE:N.T.S V = N N O CO Co2010 pyright :. IJ r2 1 Architectural Engineering Design Group, Inc. W NORTH NORTH rlJ r All design drawings and written materal I TRACK TRACK NORTH SOUTH herein may not be used or duplicated without TRACK TRACK the written consent of Architectural ' Engineering Design Group,Inc. W.� WS5 SECOND LEVEL 2ND LVL MERGH W J ljcb NORTH o PENDANTS T 1�°o .' GATSe (TYP)A _� DDD 0 EG PROVIDED ES SC -N1 'RPI' 120V OUTSIDE PHONE LINE En LIGHTING CONTROL S DESIGN LIGHTING RELAY PANEL SCHEDULE WS2' 'W56' PANEL NAME: RPI MANUFACTURER: LC4D,COOPER GREENGATE,HATTSTOPPER,OR EQUAL I o MAIN LEVEL 46RI400 SERIES MAIN LVL MERGH MAIN LVL MERCH PANEL LOCATION: MAIN FLOOR ELECTRICAL ROOM J O SUPPLY GIRGUIT: P12-104 w od CONT LINE FEED LOAD DESCRIPTION HALL STATION RELAY RELAY NUMBER RELAY HALL STATION LOAD DESCRIPTION LINE FEED CONT N SEQ BUTTON NUMBER TYPE TYPE BUTTON NUMBER SEQ U J Om i CI PI2-85 2ND LVL MERGH LT6 141^15:5-b I 2 12OV/IPOLE WS3-a LOWER LVL MERGH TRACK PI2-8l CI ` CI PI2-85 2ND LVL MERGH LT6 1^15:5-b12OV/IPOLE 3 4 12OV/IPOLE WS3-b LOWER LVL MERCH TRACK P12-84 CI O SPARE 12OV/IPOLE 5 6 120V/IPOLE HS3-C LONER LVL MERCH TRACK PI2-41 CI 12 11:(E0:1_, 1_,411. 'W553 SPARE 120V/IPOLE 1 8 120V/IPOLE NO OVERRIDE CORRIDOR P12-108 CI I ` wJ LOWER LEVEL LOWER LVL MERGH GI PI2-41 MAIN LVL MERGH LTG WS2-c 120V/IPOLE 4 10 _120V/IPOLE SPARE U To 0 J GI PI2-44 MAIN LVL MERGH LTG WS2 d 120V/IPOLE II 12 12OV/IPOLE SPARE w yC �_� 1 BUILDING LIGHTING CONTROL O N E L I N E DIAGRAM CI PI2-101 MAIN LVL MERGH LT6 WS2-e 120V/IPOLE 13 14 120V/IPOLE SPARE - L J U cy' WS6' GI PI2-41 MAIN LVL MERGH LTG W524 120V/IPOLE 15 16 120V/IPOLE SPARE w i p 3-BUTTON I"1SS E5GI PI2-43 MAIN LVL MERGH LTG 156-g 120V/IPOLE 11 18 12OV/IPOLE SPARE 2-BUTTON .1 SCALE:N.T.S GI PI2-45 MAIN LVL MERCH LTG 1^1.56-h 120V/IPOLE 14 20 12OV/IPOLE SPARE C,) #GH-3-WH-WH GI PI2-45 MAIN LVL MERCH LTG WS6-1 12OV/IPOLE 21 22 12OV/IPOLE SPARE .0 #GH-2-WH-WHJ SHEET NO.: ali NOTE_ SPARE 120V/IPOLE 23 24 12OV/IPOLE SPARE a3 THIS SCHEMATIC SHOWS AN INTENT OF THE EQUIPMENT CONNECTIONS FOR THE OVERALL 2 WALL STATION BUTTON LABELING D ETA I L CONTROL OF THE BUILDING PUBLIC AREA LIGHTING SYSTEMS. IT DOES NOT REPRESENT NOTES: ACTUAL WIRING DIAGRAMS.THE ELEGTRIGAL CONTRACTOR MUST COORDINATE WITH THE I. CONFIRM ALL PROGRAMMING WITH OWNER PRIOR TO COMMISSIONING. W [ 5 . 1 LIGHTING CONTROL MANUFACTURER AND SUBMIT THE ACTUAL HIRE DIAGRAMS FOR EQUIPMENT E5.1 SCALE: N.T.S INTERCONNECTION AS PART OF THE SUBMITTAL PROCESS. 1,3 CONTROL SEQUENCE GI TURN ON VIA TIMEGLOCK AT SAM,TURN OFF VIA TIMEGLOCK AT IIPM E 5 1 Q3 :ti U l Q