Loading...
HomeMy WebLinkAboutB14-0224_M0.0_1415134560.pdf liti OF kg 4°409111 . z(4.0 1141110( ir! D S I \ COND I T I O\S D JCT O < L \D P I P' n\G G \D G \ IR/AL G \D P. A\ A55 V14110\5 Towr WINTER DESIGN TEMPERATURES: INDOOR: 10 F DB SINGLE LINE DESCRIPTION DOUBLE LINE >< OR - - GATE VALVE CO CARBON MONOXIDE SENSOR AAV AIR ADMITTANCE VALVE (STUDOR OR EQUAL) *4ib '# OUTDOOR: -20 F DB —ii— CHECK VALVE C2 CARBON DIOXIDE SENSOR AFF ABOVE FINISHED FLOOR 90* ELBOW DOWN ` ) 0.71ccop 1ocili —a OR f BALL VALVE OH HUMIDISTAT ASV ABOVE ELEVATION 8150 FEET f BUTTERFLY VALVE ®D DEHUMIDISTAT BLW BELOW 11/04/14 90° ELBOW UP 4 ELECTRICAL POWER AVAILABLE 115/1, 205/1, —10i OR 0 PLUG VALVE 0 NITROGEN DIOXIDE SENSOR CFM CUBIC FEET PER MINUTE (AIR QUANTITY) 208/3 OFFSET TO CHANGE ELEVATION ■ > GPM CIRCUIT SETTER WITH GPM I ) ( AT 30 WHEN POSSIBLE. EffD e OCCUPANY SENSOR (RE: ELECTRICAL) CLG CEILING 04 III in W ARROW SLOPES DN. ) —DO( GLOBE VALVE PB ERV PUSH BUTTON CONTROLLER (LIGHTED) CO CLEANOUTU al 5 LLI (NI II ROUND RADIUS ELBOWin '% %/ OR STRAINER (Y-TYPE) WITH BLOW-DOWN PT ERV PERCENT TIMER CONTROLLER (LIGHTED) GONG CONCRETE Z 111 Lu [ 1 OR A TWO-WAY AUTOMATIC CONTROL VALVE O SENSOR COTG CLEAN-OUT TO GRADE iii OR ►i THREE-WAY AUTOMATIC DIVERTING VALVE O THERMOSTAT DN DOWN Di ; I- I- SI 1\D 90° STRAIGHT TEE a•x OR -074- SOLENOID VALVE POINT OF DISCONNECTION DMPR DAMPER 9 0 SHEET DESCRIPTION I ii OR �i PRESSURE REGULATOR (OR REDUCING VALVE) e POINT OF NEW CONNECTION EA EACH01 CI 2 - - 1 9(d° CONICAL TEE Co O M0.0 MECHANICAL COVER SHEET ��� MIS TWO-WAY MODULATING CONTROL VALVE $ WALL ON/OFF CONTROL SWITCH EC ELECTRICAL CONTRACTOR \� Ml.m MECHANICAL SCHEDULES / EINE IMI THREE-WAY MODULATING MIXING VALVE ER / EG EXHAUST REGISTER / EXHAUST GRILLE • X f 45* BRANCH M2.0 LOWER LEVEL MECHANICAL PLAN EINE 0 I. THERMOSTATIC MIXING VALVE (TMV) ETR EXISTING TO REMAIN Z I Ce AN D VIS4 _ a I� DP DIFFERENTIAL PRESSURE VALVE EXH EXHAUST \ 111 Z M2.1 STREET LEVEL MECHANICAL PLAN 45° CONICAL TEE . S 04 S sI J\ I y� Fit M22 UPPER LEVEL MECHANICAL PLAN ��� OR }^ PRESSURE RELIEF VALVE FCO FLOOR CLEAN-OUT Nd M3.0 MECHANICAL SCHEMATICS n V (��� I MANUAL AIR VENT FD FIRE DAMPER OR FLOOR DRAIN 10 1 v I- �� SIZE OR SHAPE TRANSITION 101: Z -I- 00 V� /\ �� AUTOMATIC AIR VENT SIZE (INCHES) FPC FIRE PROTECTION CONTRACTOR Z 0� ° 00 M4.0 MECHANICAL SPECIFICATIONS 4 SEQUENCE OF _ 0 n a OPERATION Q v VACUUM BREAKER NOTE: FOR STANDARD MODULE SIZE GPM GALLONS PER MINUTE (WATER FLOW RATE) '1- .j �`JVNMI�I ROUND FLEXIBLE DUCT Y REGISTERS, SIZE GIVEN IS NECK II OR PRESSURE GAUGE WITH GAUGE COCK SIZE. REFER TO AIR DEVICE SCHEDULE LD SUPPLY DIFFUSER (LINEAR) Kovvv% ^^^^ _� 0\ / QPRESSURE SENSORSHEET FOR MODULE SIZE. MCMECHANICAL CONTRACTOR �� � 0 � � X 90° ELBOW DOWN x = AIR QUANTITY (CFM) ® 02 10 'I` PRESSURE / TEMPERATURE TEST PORT 1 CA = COMB. AIR MOD MOTOR OPERATED DAMPER ' ► 1 OSA = OUTSIDE AIR 0 0 UI Q TEMPERATURE SENSOR 12/�o D-250 RET = RETURN OA (OR OSA) OUTSIDE AIR I 9m° ELBOW UP m EXH = EXHAUST PE Stamp 0 1- N THERMOMETER WELL MUA = MAKE-UP AIR PC PLUMBING CONTRACTOR Z 0 DROP/ RISE DROP/ RISE OFFSET TO CHANGE ELEVATION (AT 3m° o THERMOMETERI PLNM PLENUM s �pD� LIOF t� � TYPE OF AIR DEVICE. O �(/ v) I > l WHERE POSSIBLE). ARROW IN DIRECTION i �F►► J OF AIRFLOW. INDICATE DROP OR RISE. --`-� RE: SCHEDULE SHEET i�V ; P p 11 0 BTU METER (FLOW 4 TEMPERATURE DIFFERENCE) PR PIPE RISER ; 4 .� •�9 / F 0O ROUND RADIUS ELBOW Q FLOW METER RA (OR R/A) RETURN AIR 30290 Fs FLOW SWITCH IR 1 RR RETURN REGISTER ���1 /2 2/14;.���l O l: RECTANGULAR ELBOW WITH ME 4 AQUASTAT RG (RAG) RETURN AIR GRILLE int,'CONAL�_NO�+ CI)m � TURNING VANES Ell �OOp4— OR -- kBRAIDED TYPE FLEXIBLE PIPE CONNECTOR D S I G N A I C\ < SA (OR S/A) SUPPLY AIR ,`,``\��0"` Q • 0_ 0 SPLIT BRANCH TAKE-OFF WITH SQUARE ELBOW 4 1M&Iim W ELASTOMERIG PIPING ISOLATOR (WITH KEVLAR) S. DMPR SMOKE DAMPER 11.1 w N 0 DUCTING: PIPING: SPLITTER DAMPER —I I I— PIPE UNION OA - OUTSIDE AIR CH - CHILLED/HEATING WATER SR SUPPLY REGISTER (SIDEWALL OR DUCT MOUNTED) O UI J SPLIT BRANCH TAKE-OFFTE - TOILET EXHAUST DW - DOMESTIC WATER I I QUICK CONNECT (GAS) OR HOSE BIB (WATER) SV STUDOR VENT (SIZED BY CONTRACTOR) WITH RADIUS ELBOW 4 G - GAS i- m SPLITTER DAMPER OR ��\ RADIANT OR SNOWMELT MANIFOLD WITH ACCESS GENERAL: SM - SNOWMELT TYP TYPICAL . l I- US - UTILITY SHAFT SD - STORM WATER (SD AND/OR OD) 071 0 BRANCH TAKE-OFF WITH 0 PIPE UP OR PIPE UP 4 DOWN PIPE DOWN ® WV - WASTE AND/OR VENT TRANS TRANSITION O q z RADIUS HEEL AND DAMPER OR 0 T/A THROW AWAY "4 Ei W111 lY BRANCH TAKE-OFF WITH O FLOOR DRAIN v RISER NUMBER UNO v UNLESS NOTED OTHERWISE '^^) AIR EXTRACTOR = FLOOR SINK US UTILITY SHAFT r� IL4 ft LINED DUCTWORKZ ^—I I HORIZONTAL CLEANOUT VTR VENT THROUGH ROOF C n Q00 (� (UNLESS NOTED OTHERWISE) E 4) © OR 0 FLOOR CLEAN-OUT A 1 F FM F\A L ,.- \•••, 1 W/ WITH O 0 = • SQUARE NECK CEILING DIFFUSER OM METER WCO WALL CLEAN-OUT U W A 11_ X 4-WAY DIRECTIONAL THROW ® I �4 I �\ < Z UNLESS INDICATED OTHERWISE IL XFR TRANSFER 9 g llU N 4 Z _, ROUND NECK CEILING DIFFUSER FIFFf \ I f \S , a- -e- 4-WAY DIRECTIONAL THROW 0 TERMINAL TYPE: I 1Z �W UNLESS INDICATED OTHERWISE CWS/R CHILLED WATER SUPPLY/RETURN GV - CONSTANT VOLUME BOX CSERIES) 4 1NFM VI4551RA I �lS O _ FP FAN POWERED BOX (PARALLEL) 124 Coi) SIDEWALL SUPPY GRILLE T CS/R CONDENSER WATER SUPPLY/RETURN VV - VARIABLE VOLUME i~ T HWS/R HEATING WATER SUPPLY/RETURN VR - VARIABLE VOLUME w/ REHEAT AHU AIR HANDLING UNIT 01 u1 O OR REGISTER WITH 0 I AIR EXTRACTOR NWS/R(HT) HEATING WATER SUPPLY/RETURN HIGH TEMP AS AIR SEPARATOR O 4 N HWS/R(LT) HEATING WATER SUPPLY/RETURN LOW TEMP � COOLING AIR QUANTITY (CFM) 1_1 U 1�U = HALF ROUND NECK SMS/R SNOWMELT SUPPLY/RETURN m 1 100 B BOILER (HOT WATER) r-1 O 111 CEILING DIFFUSER D RS 4 RL REFRIGERANT SUCTION 4 REF. LIQUID m 540 MINIMUM AIR QUANTITY (CFM) FOR ^ �/ y y VENTILATION OR HEATING. CH CHILLER o 4 . , ----------- DOMESTIC COLD WATER (DCW) 11 i- PRIMARY AIR VALVE SIZE DOMESTIC HOT WATER (DPW) CC COILING COIL z ry " SUPPLY DUCT RISER " -_—-—-—-- DOMESTIC HOT WATER RECIRC (DHR) 110CH CABINET HEATER 4t4 Lu DOMESTIC HOT WATER AT TEMP SHOWN ^, Z O ` V al � RETURN, EXHAUST OR W WASTE CT COOLING TOWER CELLLU OUTSIDE AIR DUCT RISER - - - - -Y- - - - - VENT4111 i-2 LuW GW GREASE WASTE CV CONSTANT VOLUME BOX )- CEILING RETURN AIR PW PRESSURIZED WASTE DEF DISHWASHER EXHAUST FAN 0 ��/ GRILLE OR REGISTER \ -i,- IW INDIRECT WASTE 4 p BD BUILDING DRAIN EBH ELECTRIC BASEBOARD HEATER 0 Q 4 + 55 BUILDING SEWER DOOR GRILLE SD STORM DRAIN ECU EVAPORATIVE COOLING UNIT OD OVERFLOW DRAIN (STORM) EF EXHAUST FAN V Id SOD SEDIMENT 4 OIL DRAIN Issued For Z G NATURAL GAS ERV ENERGY RECOVERY VENTILATOR (AIR TO AIR HX) MANUAL BALANCING DAMPER - No. Date Comment MPG MEDIUM PRESSURE NATURAL GAS ET EXPANSION TANKcZ LPG PROPANE GAS 1 &/4/14 COORDINATION s 9 446 MOTORIZED DAMPER O. D DRAIN FC FAN COIL 2 (0/I3/14 PERMIT CD CONDENSATE DRAIN FP FAN POWERED BOX 3 7/10/14 PERMIT RESUB 0 Z • F FIRE SPRINKLER 4 9/22/14 PERMIT REVISIONS 1- O CA COMPRESSED AIR GF GLYCOL FEEDER SMOKE DAMPER pel GEO GEOEXCHANGE SOURCE Z SWS/R SOLAR WATER SUPPLY/RETURN HC HEATING COIL 4 in (E) EXISTING Q- I- ® _ HP HEAT PUMP �"r�GI-I�N I G AA U1 111 FIRE DAMPER (UG) UNDERGROUND HX HEAT EXCHANGER COVER SHEET to o_ U U H HUMIDIFIER I ® COMBINATION FIRE AND SMOKE DAMPER E0 Lu Z /S - F/S KEF KITCHEN EXHAUST FAN (Y )_ (k INLINE WET ROTOR PUMP 1L ALU I 3 CEILING RADIATION DAMPER I t_♦ to INLINE WET ROTOR PUMP (W/ INTEGRAL CHECK) MV MIXING VALVE O z P PUMP (SEE PIPING LEGEND FOR DETAILS) Q17-XEL 1Z INLINE CLOSE-COUPLED PUMP RF RETURN/RELIEF AIR FAN > w (k +4 GRAVITY BACKDRAFT DAMPER 11ci 1 , in SUPPLY FAN Project No. Scale: Z 0 LV 11V BASE MOUNTED END SUCTION PUMP TEF TOILET EXHAUST FAN 14045.00 N/A O 0 }DUCT MOUNTED SMOKE DETECTOR S Drawn By: Checked By: 0 Z `t z 0 \ / \ / TMV THERMOSTATIC MIXING VALVE • JAi-I JDR cD w I- \ / CEILING ACCESS PANEL \ / UH UNIT HEATER � •._ 0 v v VV VARIABLE VOLUME BOX . i j WALL CAP - BATH OR DRYER EXHAUST VR VARIABLE VOLUME BOX W/ REHEAT INiIO.O 0 0 0 WITH INTEGRAL BACKDRAFT DAMPER WH WATER HEATER Q O