HomeMy WebLinkAboutB14-0224_M2.2_1407262320.pdf 00 OF
4,:ciadipiwe.foi... La iiilivwi7ril
'
w
cc
x to
LU O3"� PVC BOILER CA PIPES. 3"� CPVC BOILER FLUES. SLOPE 4 lb
} } (TYP OF 3) 1/4" PER LINEAR FOOT BACK TO
_I _I BOILER. TERMINATE ABOVE ROOF. 0,) el'
00 SUPPORT PIPING I CHASE AS
lao31
0 0 REQUIRED. CTYP F 3)
t I I I I 08/05/14
1=1 Ilmi%.,
0 ti
U1
o � r - - � o CU-I ON ROOF ABOVE. OC \� \ / / J Z
STORAGE SKI TUNING q o L — \ i Le w III Z
J = Hi
ce U1
H- MECHANICAL
L CHASE i -' W 7
I-
I I
WO (OSA) \ \ \ ❑EFICES i 00 oi 0
� �
S O (EXH) Z x
ALTERATI❑NS x - BALCONY W z
o2 p
tT)
RE-CONN=CT NEW BATH FIXTURES i \ `�
AND FA • .E) DOMESTIC LINES .. w (A1.041
'�
ANpT� � •E� RT AS REQUIRED, w 0
/ \ui
I ;31-
lir'Li-
®
Ili
ce-
0 1
I-
I-
BALCONY MECH DASHED LINE INDICATES 1- _ I I \ Seal ;� ��t Li
AREA OF SCOPE.
0 ~ Q I I I ��� I-
LU r. S, I
-_,.(e.-
PLANNING REa�p0� Li til O
❑BEIGE BATH / BOH S A3HVE NEV - - - - ����m�7 10/14°�{�n:4#1i! I-
I < > SERVICE < > ' -
• O' BOLTS
BOUTS ABOVE
ELEV. _------4-------1
� 4i 39
1 p
U1
WORK BENCH ' ��'a���;�• . i?...
•'�a�iO3OI, BATH �,1S�NAL �TU1BHHTSJ ! ��'�11tti�• � �
` EQUIP, ST❑R. _ ❑EEICE 1 � Z =
STORAGE/REPAIR D
STOP, 5 O
z STAIRS
CHANGING UP N U
WHRK BENCH ROOM - - 0
L
O
I A I _IO
ll I I L I T - - - -I CS W m ci
r -1 I
lE) EVAP. COOLER ON 0 n
z ROOF A�nVE. 0 N et
, o
ZN www
STAIRS A In
00 sr rT� o Hi
UP Fil
U
1- al
U Efei L..) 00
STATR w Q 6/6 EG-1 93 w
�r
DOWN q W C6"� RUN-OUT)�� EQL P 9"0 OSA DUCT UP THROUGH ROOF. O Q
1- EQUIP. = TERMINATE ABOVE ROOF WITH U1
bi
GOOSE NECK. CTYP OF 2) U C
IL
U 1, II Il „ „ 0 p4 ...., , z
01 01 01 01 01 4
_ \ \ Z 2
Qo
I _ I _ INSULATE OSA AND SUPPLY AIR DUCTS `n
FROM ERV-I 4 2. RE: SPECS. ° 0 V I-
O
I RV-2 ERV-1 U Z
\ - 4
1 I i 1 --...,, T ' T:' M--4 N z 0_
STAIRS 9"4, EXH DUCT UP THROUGH ROOF. U1 =
DOW 6/6 SG-1 93_...._1_61 ~
TERMINATE ABOVE ROOF WITH
l6"� RUN-OUT) GOOSE NECK. MAINTAIN 10' U1 O
O CLEARANCE TO FORCED AIR > co (0
INTAKES, (TYP OF 2) _
luI OL
DISPLAY CI
-----r- STAIRS - Z
WN
ry
D❑ Issued For Lu
N \ IL No. Date Comment 111 1E
STAI S 1 6/4/14 COORDINATION 11.1p-
DOWN I 2 6/13/14 PERMIT I I in
IT
1 1 _ 3 1/10/14 PERMIT RESUB m
\\ 0
N 4 Ll
N p 4
w I—
/ STARS ST❑R. UZ1 0-
,� \ \ I \ \ , s2
I- d
I= O Z
J L I 1-O
E
cn O
Z
U
- ° — 41,1
lL i_
— — UPPE1R LEVEL U1 U1
1"IECI-1�4NIC4L PL 4N = al Z
\ IT >- lx
_I 111
II DISPLAY
BALCONY P-01:\
n " 0 - z
BALC❑NYNTN > uXi (k
I, 1 I I
ci Project No. Scale: z 0
1
r
I--7h -- -- - 1T I I Th -^ ,1T Drawn By: Checked By: 0i, 0
J 4a-I JR W Z Z
zztV
4w )-
zCK,_ , 0_M ,_ , o
QUO