Loading...
HomeMy WebLinkAboutB14-0232_A1.0 Cover Sheet_1406318040.pdf F leA 4%.041p*.,....rollti T MATERIAL SYMBOLS: COPPEL RESIDENCE DRAWING INDEX. id m ill III // // A1.0 COVER SHEET # '49P 16.7 I I S 1IiU EARTH PLYWOOD PARCEL #: 2 1 0 1 -082-87-0 1 0 ARCHITECTURAL 1 O � O � C PERVIOUS FILL ��� FINISH WOOD 1 5 1 VAIL LAN E �i///;i0 iii A1.1 LEVEL 1 EXISTING FLOOR PLAN v% /ii/ii /moi STONE MASONRY WOOD-ROUGH VA I L, C 0 8 1 6 5 7 �7�25��4 , / A1.2 LEVEL 2 EXISTING FLOOR PLAN � PERMIT SUBMITTAL A1.3 LEVEL 3 EXISTING FLOOR PLAN STRUCTURAL CONCRETE �� BLOCKING JUNE 27 , 2014 A1.4 LEVEL 4 EXISTING FLOOR PLAN N • •z CONCRETE MASONRY UNIT GYPSUM BOARDvy ? a A2.1 LEVEL 1 FLOOR PLAN "' 00 4 IP BATT INSULATION RIGID INSULATION A2.2 LEVEL 2 FLOOR PLAN I- 15 io PROJECT DIRECTORY. PROJECT SUMMARY. A2.3 LEVEL 3 FLOOR PLAN (1) .3 1 U // // // STEEL/METAL AS NOTED IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII CARPET LA - a) THE PROJECT CONSISTS OF INTERIOR MODIFICATIONS TO A 4-LEVEL > ARCHITECT OWNER CONDOMINIUM, INCLUDING THE FOLLOWING: A2.4 LEVEL 4 FLOOR PLANCc 1 1 -RECONFIGURE INTERIOR PARTITIONS AND OPENINGS AT LEVEL 1 4 4 I— A4.00 I A3.00ENTRIES BLUELINE ARCHITECTS, P.C. MMARJE LLC -ADD KITCHEN ISLAND AND BAR, RECONFIGURE PANTRY AND A6.1 INTERIOR ELEVATIONS 1444 MARKET STREET 60 HOPETOUN RD REPLACE KITCHEN APPLIANCES, VENT HOOD TO EXTERIOR I o -MODIFY DOOR LOCATIONS AT LEVEL I AND 4 POWDER ROOMS A6.2 INTERIOR ELEVATIONS BUILDING SECTION REFERENCE ELEVATION REFERENCE DENVER, CO 50202 TOORAK VICTORIA 3142 -RECONFIGURE BATHROOMS AT LEVEL 2 AND 3, REPLACE FIXTURES U m AUSTRALIA -REPLACE GUARDRAILS AND HANDRAILS THROUGHOUT A6.3 INTERIOR ELEVATIONS (1) 1 1 303.893.0346 (W) -ADD CABINETS 4 SHELVING THROUGHOUT 'C.') L A6.00 `� A6.00 1 910.362052 (C) -MODIFY INTERIOR ELECTRICAL AND LIGHTING LAYOUTS THROUGHOUTD a CONTACT: KEN BRIDGES, AIA A9.1 LEVEL 1 CEILING/POWER PLAN o LEGAL SUMMARY: 4 o co DETAIL REFERENCE DETAIL REFERENCE SUBDIVISION: CHALETS AT THE LODGE AT VAIL UNIT: 10 A9.2 LEVEL 2 CEILING/POWER PLAN o a CONTRACTOR STRUCTURAL EXISTING UNIT SQUARE FOOTAGE: A9.3 LEVEL 3 CEILING/POWER PLAND a Y . T.O. PLYWD 1 5231 SF 100'-0" A6.00 I CODE: A9.4 LEVEL 4 CEILING/POWER PLAN T SQUARED BUILDERS, INC. KRM CONSULTANTS, INC- IBC 2012 P.O. BOX 331 P.O. BOX 4512 CONSTRUCTION TYPE: HEIGHT REFERENCE SECTION REFERENCE MINTURN, CO 81645 VAIL, CO 81658 TYPE V-B STRUCTURAL 910.911.0115 (C) 910.949.9391 (W) OCCUPANCY CLASSIFICATION: ROOM NAME CONTACT: THOM CONVILLE CONTACT: TIM HENNUM, P.E. GROUP R-2 S1 FOUNDATION PLAN ZONING: SBR-2 (SKI-BASE RECREATION 2) 1 REVISION REFERENCE ROOM NAME GRID W11 GENERAL NOTES: W GRID BUBBLE WALL TYPE REFERENCE 1 01 DO NOT SCALE DRAWINGS 06 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE 10 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN 0 O O 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, APPROVAL FROM THE ARCHITECT 4 ENGINEER BEFORE ANY LOCATIONS ON THE JOB SITE PRIOR TO BEGINNING ANY MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE J * 0 4 A7.0 2 A OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL 1 i WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF Z in N ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS OF THE INDUSTRY. ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF _ 3 IMMEDIATELY. THE BUILDING. W Z CO 01 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, U.N.O. SECTION AND ELEVATION DIMENSIONS ARE TO 11 THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR INTERIOR ELEVATION REFERENCE WINDOW TAG 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY ANY SUBSTITUTIONS OR OMISSIONS TO THE WORK AS INDICATED El_ W W N i- TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL O 0 STONE- 0 -WOOD RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT PLATES OR BEAMS, U.N.O. IN THE CONTRACT DOCUMENTS IF WRITTEN APPROVAL BY THE Z O BEFORE CONSTRUCTION CONTINUES IN THOSE AREAS. ARCHITECT IS NOT RECEIVED PRIOR TO THE MODIFICATION(S). f CI < 0 O DOOR TAG MATERIAL BREAK J U ' 04 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS 08 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO — 1 .. 0 ASPECTS OF THIS PROJECT, THE CONTRACTOR SHALL CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET O Q J IMMEDIATELY NOTIFY THE ARCHITECT. ACCESSORIES, GRAB BARS, CABINETRY, COUNTERTOPS, (n > ; N ABBREVIATIONS: 05 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL SHELVES AND CLOSET RODS. APPLICABLE CODES AND OBTAINING ALL PERMITS AND0 O Z REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE 2012 09 ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN L(1 INTERNATIONAL BUILDING CODE. CODE COMPLIANCE IS CEILING,RIT FLOOR AND WALL SPACES. VERIFY LOCATIONS WITH a MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT ARCHITECT. Et ABV ABOVE FP FIREPROOFING, SPRAYED PL PLASTIC LAMINATE WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES AC ACOUSTICAL FPI-1B FREEZE PROOF NOSE BIB PK PARKING INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. ADD ADDENDUM FPL FIREPLACE PL PROPERTY LINE ADJ ADJACENT FTG FOOTING PR PAIR AFF ALT ALUMINUM ALTERNATE GA GAGE, GAUGE PSI POUNDS PER SQUARE INCH �# _ 44. A ~' .. ,c..„ ABOVE ALUM L GC GENERAL CONTRACT COR) PT POINT #" "..� 3 AP ACCESS PANEL GL GLASS, GLAZING PVMT PAVEMENT ' " "' ' - �" ,�. ARCH ARCHITECT (URAL) GV GALVANIZED QT QUARRY TILE 1 ,' — Pte- '� ■ - �lfs'.it ti. Fao ��� � " BASMT BASEMENT GYP BD GYPSUM BOARD R RISER _ ;f� �:_ .�-`r "�r • ' �eek" R BIT BITUMINUOUS HB NOSE BIB REF REFERENCE L. Imo. .,; s. r BLDG BUILDING HC HOLLOW CORE REFR REFRIGERATOR 1 ». " - • R saeite .. } BLK BLOCK I-IDR HEADER REINF REINFORCE (D), (ING) # .a- a 4 Me, - , - BLKG BLOCKING HDW HARDWARE READ REQUIRED 11-: ' . .pi 4 T 50 BOTTOM OF HM HOLLOW METAL RES RESILIENT ,.' °'.- `" • . NAL 'I • - "� ISSUED FOR: DATE: y BOT BOTTOM NOR HORIZONTAL REV REVISION (D), (ING) r. .f :' - k • r `.' . • „: .y. _ BRG BEARING HT HEIGHT REVS REVERSE a-�' � °'+ - ,° : F'� DRB SUBMITTAL 06.20.14 BVL BEVELED I-ITG HEATING RD ROOF DRAIN ;fir• t ► .. T _ r ,. ' ' ' • , PERMIT SUBMITTAL 06.27.14 C CAULK (ING) HVAC HEATING/VENTILATING/AC RFG ROOFING " P` ,r `• Jr ``�' ' 4'_ -* - ' ' � ;- 'F } mak• • ' 'Fa+ven rbthee':Gor ' CJT CONTROL JOINT I-IWI-I HOT WATER HEATER RH RIGHT HAND .. r x ;- -� r - ' GLG CEILING IBC INSTALLED BY CONTRACTOR RM ROOM - ` ^ '� 'a .e ��� r. CLR CLEAR IBO INSTALLED BY OWNER RO ROUGH OPENING '„ • J. litt �� , Ufa • d ,�- ' CMU CONCRETE MASONRY UNIT ID INSIDE DIAMETER R4S ROD AND SHELF ," �1 ,+ �_; a • _ r COL COLUMN INCL INCLUDE (D), (ING) R/S ROUGH SAWNlei • 'l II , CONC CONCRETE INS INSULATE ( ) (ION) S SEALANT l XT IO ) 41- o REE L E DE ER R j' :3 ., ,� ' ; ° .Y` =' 7I 1:-I ---ui ;''- • moi. I- r_:Eli , W , ,.. , =�_.�.. CONST CONSTRUCTION INT INTERIOR SC SOLID CORE �, k� e��at `:' . CONT CONTINUOUS JC JANITORS CLOSET SD STORM DRAIN - '*► It 0; rl 't r -` CPR COPPER KIT KITCHEN SHTG SHEATHING r. • ' •. "' "� + +� _ '_ , CPT CARPET (ED) L LENGTH SIM SIMILAR ' ' `•' _ , 1' _ - :II.b' CSMT CASEMENT AM LAMINATE ( ) SM SHEET METAL - ":5'+ ,+ -: ' - ' - L L E D EE E L --, I _ r RX> s _� :•••'4•''114 '���3 Cp(Q CT CERAMIC TILE LAY LAVATORY SPEC SPECIFIGATON (5) - , - - N, '-.; �,. �� qQOUST CUSTOM LDT LIGHT AND DRAPERY TROUGH SQ SQUARE '" . ' AD DF DRINKING FOUNTAIN LH LEFT HAND ST STAIN ; • =d # i.__. K. ' 'E RAYDIM DIMENSION LT LIGHT TROUGH STD STANDARD `� ■' w'.DR DOOR LTL LINTEL STL STEEL .' , t _ - y -' ;RIDGES IIT A Y T OU H V OUV ST ST UCTU A -D DR PER R G L R L ER R R R L �." g. }- ^y• . ;-:-;� '.kr 1yEx�resti lift - -DTL DETAIL M METER (5) T TREAD r . . " , t' Iar, (� ms, - DWG DRAWING MAX MAXIMUM TB TOWEL BAR ._ •'!':'• .. , .,,r ' '�;�►} + {�` EL ELEVATION (5) MC MEDICINE CABINET TEL TELEPHONE _ `""= "`� ii S;, " r �+ I it__. 1 I. USED ARC" ELEC ELECTRIC (AL) MECH MECHANIC (AL) THR THRESHOLD _ *-1-.,' � • A: ." -. - ELEV ELEVATOR MET METAL TO TOP OF ti • • " ,' `ti, , r , ; F • -. ,24I-,....-, _, EQ EQUAL MFR MANUFACTURE (ER) TR TRANSOM • *.:,.... .1.4.:17,...-,'-‘:10). ,• - E- -=';, 7��: 1 , - �. , �,.4. -� .f --- I SHEET SCALE N.T.S. EXG EXISTING MH MANHOLE TS TOP OF SLAB 7-1r1.91 ,, i ■y EXIH EXHAUST MIN MINIMUM TSL TOP OF STEEL :rt.: , . _ ein.. . �, DRAWN BY: BL EXT EXTERIOR MIR MIRROR TV TELEVISION '�' L •. �;� ti +R a 4�i % � :' L.�. . ;,; �___ w ' ` # - t CHECKED BY: KB • FBO FURNISHED BY OTHERS MISC MISCELLANEOUS TW TOP OF WALL y� • i " . _8.' TA "�' i - `ti: r�. �'�-__ _ COPYRIGHT 2013 FD FLOOR DRAIN MMB MEMBRANE TYP TYPICAL �. +rw _7` + \ .; e •. * © BLUELINE ARCHITECTS P.C. FDC FIRE DEPARTMENT CONNECTION MM MILLIMETER (5) T4G TONGUE AND GROOVE .,. _._ _ . . ' .gay ' = . FE FIRE EXTINGUISHER MO MASONRY OPENING UNO UNLESS NOTED OTHERWISE �� _- {- '� ■+ PROJECT#: 1408 FEC FIRE EXTINGUISHER CABINET MTL MATERIAL VB VAPOR BARRIER r - •--,� '^ L • -�- - d A - �;t_ M,,, P . _ SHEET TITLE COVER SHEET FF FINISHED FLOOR ELEVATION MULL MULLION VCT VINYL COMPOSITION - . � rte* r,_J= w 4� ,•' 'r: _,r=�.�^ ; FHC FIRE HOSE CONNECTION NAT NATURAL VERT VERTICAL �°' ti - AFL -..,; Y s FIN FINISH (ED) NIC NOT IN CONTRACT VIF VERIFY IN FIELD FLG FLASHING NOM NOMINAL W WIDTH, WIDE FLR FLOOR (ING) NR NOISE REDUCTION WC WATER CLOSET FND FOUNDATION NTS NOT TO SCALE WD WOODFOG FACE OF CONCRETE OH OVERHEAD WDW A1 . 0 WINDOW VICINITY MAP (\FOF FACE OF FINISH OPG OPENING WO WITHOUT FOM FACE OF MASONRY OPIH OPPOSITE HAND WP WATER PROOFING N.T.S. FOS FACE OF STUDS OPP OPPOSITE WWF WELDED WIRE FABRIC 4