HomeMy WebLinkAboutB14-0264_cut sheets part1_1438973760.pdfAcucraft Fireplaces Big Lake, MN Phone (763) 263-3156 www.acucraft.com e-mail: info@acucraft.com The Premier Manufacturer of Fireplace Systems Since 1979 Acucraft Fireplace Submittal Prepared For Project: Custom Acucraft Project Number: 1 , 2015 Acucraft Fireplace Submittal TABLE OF CONTENTS Description Custom Fireplace Approval Form......................................................................................................................... Page 1 Acucraft Custom Fireplace Payment Terms......................................................................................................... Page 2 Fireplace Order Confirmation ...........................................................................................................................Pages 3-5 Fireplace Specifications ....................................................................................................................................... Page 6 Fireplace Drawing ................................................................................................................................................ Page 7 Section View of Typical Dual Pane Glass............................................................................................................ Page 8 Typical Gas Component Assembly w/Single Rod Ignition....................................................................................Page 9 Gas Fireplace System Illustration........................................................................................................................Page 10 Gas Valve Assembly and Flue Venting Components..........................................................................................Page 11 Sequence of Operation .......................................................................................................................................Page 12 Intermittent Burner Assembly Components Manuals Y8610U Intermittent Pilot Retrofit Kit............................................................................................................Pages 13-36 AT175A Universal Transformer Manual .......................................................................................................Pages 37-40 Q314A Pilot Burner Manual .........................................................................................................................Pages 41-48 Power Vent System Components Manuals PDS 1 Proven Draft Switch Manual .............................................................................................................Pages 49-52 ADC100 Draft Control Manual......................................................................................................................Pages 53-68 RS Chimney Fan Manual .............................................................................................................................Pages 69-84 Steel Chimney Adapter Manual..............................................................................................................................Page 85 Class A Chimney Installation Manuals RIS Excel Chimney Installation and Operation Instructions .......................................................................Pages 86-105 Acucraft Fireplaces 20100 West Highway 10 Big Lake, MN 55309 Phone (763) 263-3156 Toll Free 1-888-317-6499 Fax (763) 263-8311 www.acucraft.com e-mail: info@acucraft.com The Premier Manufacturer of Fireplace Systems Since 1979 Custom Fireplace Approval Project Name Date Submitted: March , 2015 Order Confirmation Number: AAAO4575-01 Drawing Number: 10671-A-00 REV Payment Terms: enclosed within submittal I approve the submitted Fireplace Order Confirmation and the drawings. Signature X____________________________ Name:______________________ (please print) Approval Date:_________________________ Please fax or email to Acucraft Fireplaces Acucraft Internal Date Received____/_____/_____ Signature_________________________ Page 1 Acucraft Fireplaces 20100 West Highway 10 Big Lake, MN 55309 Phone (763) 263-3156 Toll Free 1-888-317-6499 Fax (763) 263-8311 www.acucraft.com e-mail: info@acucraft.com The Premier Manufacturer of Fireplace Systems Since 1979 Acucraft Custom Fireplace Payment Terms Due to the complexity and specialization of our custom fireplaces, our custom fireplace payment terms are as follows*: + 25% Design Deposit is due at time of approved order o This will place the fireplace into the drawing stage + 25% Production Deposit is due at the time of fireplace drawing approval o Once the second deposit is received, the fireplace will be scheduled for production + 50% (+ or – based on changes made by customer) The remaining balance of the fireplace is due two weeks prior to shipment of the fireplace. *Please contact your salesperson or customer fulfillment with any questions, please sign and return with your Design Deposit __________________________ By: Customer Name _______________________ Date ____/____/_____ Page 2 Page 3 Page 4 Page 5 Acucraft Fireplace Systems 20100 W. Highway 10 Big Lake, MN 55309 PH: 763-263-3156 FAX: 763-263-8311 Model – 0507 Custom Gas ST Fireplace Flue Gas Vent Run: The Acucraft Fireplace is designed to be used with certified UL103 (Class A) chimney pipe. All clearances for this flue must be adhered to. These clearances are outlined in the installation manual supplied by the flue manufacturer and supplied with this unit. The anchor plate for the flue system is connected to the top of the appliance when shipped from the factory, unless otherwise specified by the consumer. Power Vent: The termination type power vent is to be installed in accordance with the installation manual supplied. Appliance Specifications Height = 54” Width = 132” Depth = 24” Appx Wt. = 2500 lbs. Gas Type = Natural Gas Flue Size = 8” Flue Type = UL103 HT Natural Gas Input Rating (BTU/hr) 0-1370 m = 145,000BTUs/hr. Manifold Pressure (in w.c.) = 3.5 in W.C. Minimum inlet pressure (in.w.c.) = 7.0 in. W.C. Maximum inlet pressure (in.w.c.) = 12.0 in. W.C. Combustion Air inlet size = 1-10" Round Glass Cooling Air Inlet Size = 1-8” Round Gas Valve Power Input = 120 V AC Main Valve Amps = Less than 2 amps Igniter Voltage = 30,000 V Open Circuit Based on testing that was performed, the following results have been recorded. Minimum Clearances to combustiblesUnit to back wall of enclosure = 2 inches Unit to sidewall of enclosure = 2 inches Unit top to enclosure top = 4 inches NOTE: An 8” B-Vent used as a duct to remove heat from the top to the outdoors must be installed to maintain these clearances. (SUPPLIED BY OTHER) Note: The chimney flue for the appliance should never be connected to another chimney flue in any way. Page 6Page 6 Page 7 Section View of Typical Dual Pane w/ Passive Air Flow Between Panes.Firebox bodyAir manifold at top allowsheated air from betweenthe panes to rise away fromglass panels and be ventedoutdoors with the exhaust.Dual Panes of14" tempered glassGlass gasketingAir manifold at bottomdraws cooler air fromoutside into the airchamber between panesFlue ExitInsulated panelBurner assemblyAir channel betweendual glass panes (typ)Benefit of glasstemperature beingcooler to the touch.Variance in Temperatures:Dual -passive = 150-185° FHeat Relief (typ)Page 8 Gas ValveMaster Orifice (M.O.)Typical Gas Component Assemblyw/ Pilot AssemblyGas SupplyPressure to be7" W.C. nominal14" W.C. Max.Gas Pressureto be 1" W.C.at manifoldPILOT ASSEMBLYTransformer24 volt120 V AC SupplyGas Pressureto be 3.5" W.C.at outletHoneywellGND24VTH-W(GND)MVMV/PVPV25VPVMV/PVMVBLUEWHITEREDGNDGREENORANGEBLACKORANGEFrom Control SwitchTo Control SwitchPilot LinePage 9 Exhaust FanFan Junction BoxIncluded with fanFan Disconnect Switch(disconnect means andcircuit protection to beprovided by installer)Proven Draft SwitchIgnition WireMaster Orifice (M.O.)BurnerFireplace120 V AC SupplyTubingNote: This system diagram is for reference onlyand is intended to illustrate the general outlineof gas fireplace components & their relationshipwith chimney fan components for induced draft.Individual component information & specificationsfor reference shipped with the fireplace appliance.Typical Gas Components shipped with fireplace.Gas ValveModule with harnessBurner/Fuel delivery manifoldPilot burnerTransformerTypical Chimney Components/Options shippedwith fireplace.Chimney pipeExhaust Fan with adaptor to Chimney pipe.PDS (Proven Draft Switch)ADC (Automatic Draft Control)Fan Disconnect SwitchNote: The installer(s) of this fireplace and thesystem illustrated is responsible for proper gasand electrical connections for safe and reliableoperation.G A S F I R E P L A C E S Y S T E M I L L U S T R A T I O N With Proven Draft Switch and Automatic Draft Control (ADC 100 )Gas SupplyPressure to be7" W.C. nominal14" W.C. Max.fireplacecontrolswitchFireboxHeated AirInsulationInsulationGas Pressureto be 1" W.C.at manifoldENERVEXADC-100ENERVEXPDS 1To ADC-100PILOT ASSEMBLYTransformer24 volt120 V AC SupplyGas Pressureto be 3.5" W.C.at outletFrom ADC-100Line VoltageLow Voltage Signal(control wiring)AutomaticDraft Control(Can be mountedw/ valve &Ignition module)Optional Plug-inRelayOptionalCooling FanOff Delay TimerOptional Variable SpeedExhaust ControlGlass Cooling air option.Heat Relief FanOptional GlassCooling IntakeIn-line FanOptional Heat ReliefExternal PowerventHeat ReliefVentCombustion AirGlass Cooling air option.Note: 20amp Service with 2 120v Drops Gas ValvePV MV/PVMVGNDHoneywellGND24VTH-W(GND)MVMV/PVPV25VPILOT LINEPage 10 Note: No parts on this appliance may be substituted or replaced with anything other than original components designed specifically for the appliance. Replacement information on following components can be found in appendix manuals Standard Gas Valve Assembly Components Part Description Manufacturer Part number Transformer Honeywell ATI75A Complete Kit Convert Convent to Intermit Honeywell Y8610U6006 1/4 In. B Mnt BCR-10 BCR- 18 K Tip Burner Honeywell Q314A6102 Ignition Cable Honeywell 392125-2 Pilot Tubing Baso M-IC-Y99AR-1H Typical Flue Venting Components Part Description Manufacturer Part Number Proven Draft Switch Enervex PDS-1 Automatic Draft Control Enervex ADC-100 Exhausto Chimney Fan Enervex RS9 8” Steel Chimney Adapter Enervex FR2008 Typical operation of this appliance requires only turning control on. The entire sequence of operation is automatic with a single switch. No additional user input is required. Page 11 Acucraft Sequence of Operation For Gas fireplaces 1) The fireplace control switch is turned on. 2) A signal is sent to the ADC (Automatic Draft Control) turning on the exhaust fan 3) The PDS (Proven Draft Switch) proves positive draft within the flue. a. Draft proves ( go to step 4) b. Draft doesn’t prove and system locks out. (The process will need to be restarted.) 4) A signal is then sent back to the ADC which then signals the valve module to open and ignite the pilot. 5) The pilot spark igniter will discontinue sparking after flame has been proven. 6) The pilot will then send gas to the burner as well as Ignite gas and prove the flame is burning. 7) Operation normal. Page 12 PRODUCT DATA Put UPC Code Here 68-0291-03® Automatic Ignition Systems ANSI Z21.20 Y8610U Intermittent Pilot Retrofit Kit GENERAL The Y8610U is a complete kit for converting conventional standing pilot systems to intermittent pilot systems. It is used on gas-fired atmospheric furnaces, boilers, and heating appliances. Not for use on direct vent, induced draft, or power burner equipment. Meets ANSI Z21.71 standard for automatic intermittent pilot ignition systems on central furnaces and boilers. FEATURES • Y8610U kits can be used with either natural or LP gas. • The S8610U ignition control provides a 90 second maximum ignition trial, shuts off, waits five minutes nominal, then re-initiates the pilot ignition sequence. The ignition trial, shutoff, and wait cycle repeat until the pilot lights or the call for heat ends. Each kit includes: — S8610U Intermittent Pilot Module — VR8304M Dual Valve Combination Gas Control or VR8204A Dual Valve Combination Gas Control — 392431 Igniter-Sensor — 394800-30 Ignition Cable — 393691 Natural to LP Gas Conversion Kit — Wiring Harness — 393690-14 Straight Flange Kit (3/4 in.) — Reducer adapters for gas control with VR8304M — Installation hardware Temperature Ratings: — S8610U: -40°F to 165°F (-40°C to 74°C) — VR8304M: -40°F to 175°F (-40°C to 79°C) — VR8204A: 0°F to 175° F (-18°C to 79°C) Intermittent Pilot Gas Ignition Control Module • Uses flame rectification for flame sense • Internal spark generator lights pilot gas; main burner lights after pilot flame lights and proves • 100% shutoff of pilot and main gas if burner fails to light • Continuous retry ignition sequence prevents nuisance lockouts • Two LEDs indicate system status and flame signal strength Gas Control Valve • Straight through body pattern • VR8304M capacity is 270 ft 3/hr (7.6 m3/hr) • VR8204A capacity with or without 1/2” x 3/4” adapter is 150 ft 3/hr (4.2 m3/hr) • Manual ON-OFF valve blocks gas flow into the gas control when in the OFF position • Two main automatic valves: one solenoid-operated, and one a servo-operated diaphragm system Igniter-Sensor • Single electrode made of Kanthal provides both ignition and flame sensing • Rated for 1775°F (968°C) at electrode tip; 1250°F (677°C) at ceramic insulator Contents General .............................................................................1 Specifications ...................................................................2 Planning the Installation ....................................................6 Installation ........................................................................7 Settings ............................................................................14 Checkout ..........................................................................15 Operation ..........................................................................16 Troubleshooting ................................................................17 Ansi Standards .................................................................22 Page 13 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1.Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2.Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 3.http://customer.honeywell.com or http://customer.honeywell.ca In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, units might not match the listed specifications exactly. Also, units are tested and calibrated under closely controlled conditions, and some minor differ- ences in performance can be expected if those con- ditions are changed. Y8610U Intermittent Pilot Retrofit Kit Electrical Ratings: • Voltage and Frequency: 24 Vac, 60 Hz • Current Rating: 0.7A (includes both module and gas control) • Thermostat Anticipator Setting: 0.7A plus current ratings of other devices in the thermostat control circuit S8610U Intermittent Pilot Gas Ignition Control Specifications Control Voltage: Line 24 Vac (18-30 Vac) 50/60 Hz Trial for Ignition: See Table 1 above Prepurge: See Table 1 above Flame Failure Response Time: 2 seconds maximum LEDs: The green LED provides system status, error codes and indicates flame sensing Operating Temperature: Minimum ambient temperature rating is -40°F (-40°C) Maximum ambient temperature rating when used with 2.0 A main valve is 165°F (74°C) Relative Humidity: 0% to 95% non condensing Dimensions: See Fig. 2 on page 4. Thermostat Compatibility: Compatible with any Honeywell 24V thermostat and with competitive 24V thermostats that are powered indepen- dently of the module. Table 1. S8610U Universal Intermittent Pilot Gas Ignition Control Module. Igniter- Sensor Type Valve Current Rating @ 24 Vac Prepurge Timing (field selectable) Trial for Pilot Ignition (field selectable) Ignition Sequence Type Ignition Sequence (After prepurge, if prepurge is selected) Integral Damper Connector Combination (one rod; local flame sensing) 1.0 A Pilot and 2.0 A Main 0 (zero) or 30 seconds; 0 (zero) seconds recommended 15 or 90 seconds; 90 seconds recommended Retry Spark and pilot gas ON until lightoff or trial for ignition ends. If established flame is lost, trial for ignition restarts immediately. If pilot fails to light, pilot gas and spark turned off (100% shutoff). After 5 minute delay, a new trial for ignition is initiated. This sequence continues until lightoff or “Call for Heat” is removed. Included for use as needed. If initially installed and powered up with damper attached, unit must always have a vent damper connected. Page 14 Y8610U INTERMITTENT PILOT RETROFIT KIT 3 68-0291—03 Transformer Sizing: Add current ratings of Y8610, vent damper, and any other control system components. Multiply this total by 24V to determine the transformer VA requirement. Mounting: Mounts in any position except with terminals up. Recom- mended mounting position is with terminals down to provide maximum protection from dripping water or dust accumula- tion. Refer to Fig. 14 on page 12. Fasten with No. 6-32 machine screws or No. 8 sheet metal screws or 8-18 x 5/8 pan head tapping screws of appropri- ate length. Wiring Connections: — Between the module and gas control: 30 in. (762 mm) wiring harness with 1/4 in. quick-connect terminals. — Between the module and the igniter-sensor: 30 in. (762 mm) ignition cable with stud terminal and 1/4 in. quick-connect terminal. Terminals: 1/4 in. male quick-connects. S8610U has Molex plug for connection to a vent damper harness. Once the S8610U has powered a vent damper, the module works only if the vent damper is connected. VR8204A and VR8304M Dual Valve Combination Gas Controls Specifications Mounting: Can be mounted from 0 to 90 degrees, in any direction, from the gas control upright position Pressure Rating: 1/2 psig (3.45 kPa) inlet pressure Terminals: 1/4 in. male quick-connect terminals Igniter-Sensor Specifications Model: 392431 Igniter-Sensor; includes igniter-sensor assembly, ground rod, and adapter (refer to Fig. 1 on page 4) Electrode/Flame Rod Material: Kanthal Maximum Temperature Ratings: Ground Rod Tip: 1775°F (968°C) Ceramic Insulator: 1250°F (677°C) Dimensions: See Fig. 5 on page 6. Mounting: Attach the supplied ground rod and adapter, which replace the thermocouple on the existing pilot burner Table 2. VR8204A and VR8304M Dual Valve Combination Gas Controls Specifications. Model Capacity a a Based on 1,000 Btu/ft3, 0.64 specific gravity natural gas at 1 in. wc pressure drop (37.3 MJ/m 3, 0.64 specific gravity natural gas at 0.25 kPa pressure drop). Pipe Size Ambient Temperature Rating Dimensions VR8204A 150 ft3/hr (4.2 m3/hr); (with or without 1/2” x 3/4” adapter) 1/2 in. X. 1/2 in. NPT inlet x outletb b 3/4 in. straight flange included to provide 3/4” NPT outlet if needed. 0° to 175° F (-18° to 79° C) See Fig. 4 on page 5 VR8304M 270 ft3/hr (7.6 m3/hr)1/2 in. X. 3/4 in. NPT inlet x outlet -40° to 175°F (-40° to 79°C) See Fig. 3 on page 5 Page 15 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 4 Fig. 1. Y8610U retrofit kit components. Fig. 2. S8610U module dimensions in inches (mm). VR8304 S8610U INTERMITTENT PILOT MODULE WITH WIRING HARNESS 392431 IGNITER- SENSOR ASSEMBLY ALSO INCLUDED: • 394800-30 IGNITION CABLE (30 IN. (760 mm)) • 393690-14 STRAIGHT FLANGE KIT • 393691 NATURAL GAS TO LP CONVERSION KIT • REDUCER ADAPTERS FOR GAS CONTROL (WITH VR8304M) • SCREWS • WIRE NUTS (3)M32519 GROUND ROD IGNITER-SENSOR ADAPTER M32363 2 (51) 3 3/16 (81) 3 7/8 (98)3 3/8 (86) 3/16 (5) x 2 5 1/2 (140) 3 3/8 (86) x 21 1/32 (26) 3/16 (5) x 2 Page 16 Y8610U INTERMITTENT PILOT RETROFIT KIT 5 68-0291—03 Fig. 3. VR8304M mounting dimensions in inches (mm). Fig. 4. VR8204A mounting dimensions in inches (mm). OUTLET PRESSURE TAP INLET OUTLET WIRING TERMINALS (3) INLET PRESSURE TAP PRESSURE REGULATOR ADJUSTMENT (UNDER CAP SCREW) PILOT OUTLET PILOT ADJUSTMENT (UNDER CAP SCREW) GAS CONTROL KNOB M24885 3-15/16 (99) 1-7/16 (36) 2-11/16 (69) 4-1/16 (104) 4 IN. (102) MAX SWING RADIUS M24886 1/4 INCH QUICK-CONNECT TERMINALS 1 (25) 1/2 (13) 1 (25) 1/2 (13) OUTLET PRESSURE TAP INLET OUTLET WIRING TERMINALS (3) INLET PRESSURE TAP PRESSURE REGULATOR ADJUSTMENT (UNDER CAP SCREW) PILOT OUTLET PILOT ADJUSTMENT (UNDER CAP SCREW) GAS CONTROL KNOB M24887 3-1/2 (89) 1-7/16 (36) 2-11/16 (69) 3 5/8 (91) MAX SWING RADIUS M24888 1/4 INCH QUICK-CONNECT TERMINALS 1 (25) 1/2 (13) 1 (25) 1/2 (13) PV PV/MV MV 4-1/8 (108) Page 17 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 6 Fig. 5. 392431 Igniter-sensor mounting dimensions in inches. (mm). PLANNING THE INSTALLATION WARNING Fire or Explosion Hazard. Can cause severe injury, death or property damage. 1. Plan the installation as outlined below. 2. Plan for frequent maintenance as described in the Maintenance section. Intermittent pilot systems are used on a wide variety of central heating equipment and on heating appliances such as commercial cookers, agricultural equipment, industrial heating equipment and pool heaters. Some of these applications may make heavy demands on the controls, either because of frequent cycling, or because of moisture, corrosive chemicals, dust or excessive heat in the environment. In these situations, special steps may be required to prevent nuisance shutdowns and premature control module failure. These applications require special Honeywell review; contact your Honeywell Sales Representative for assistance. Review the following conditions that can apply to your specific installation and take the precautionary steps suggested. Frequent Cycling These controls are designed for use on appliances that typically cycle three to four times an hour only during the heating season. In year-round applications with greater cycling rates, the control module can wear out more quickly; perform a monthly checkout. Water or Steam Cleaning If the control module gets wet, replace it. If the appliance is likely to be cleaned with water or steam, protect (cover) the controls and wiring from water or steam flow. Mount the controls high enough above the bottom of the cabinet so they do not get wet during normal cleaning procedures. Use a NEMA 4 enclosure for the ignition control module. High Humidity or Dripping Water Dripping water can cause the control module and the gas control to fail. Never install an appliance where water can drip on the controls. In addition, high ambient humidity can cause the control module and the gas control to corrode and fail. If the appliance is in a humid atmosphere, make sure air circulation around the controls is adequate to prevent condensation. Also, regularly check out the system. A NEMA 4 enclosure is recommended for the ignition control module. Corrosive Chemicals Corrosive chemicals can attack the ignition control module and gas control, eventually causing a failure. If chemicals are used for routine cleaning, make sure they do not reach the controls. Where chemicals are suspended in air, as in some industrial or agricultural applications, use a NEMA 4 enclosure for the ignition control module. Dust or Grease Accumulation Heavy accumulations of dust or grease can cause controls to malfunction. Where dust or grease can be a problem, provide covers for the ignition control module and the gas control to limit contamination. A NEMA 4 enclosure is recommended for the ignition control module. Heat Excessively high temperatures can damage controls. Make sure the maximum ambient temperature at the control module does not exceed the rating of the control module. If the appliance operates at very high temperatures, use insulation, shielding, and air circulation, as necessary, to protect the controls. Proper insulation or shielding should be provided by the appliance manufacturer; verify proper air circulation is maintained when the appliance is installed. M6860 1-1/8 (29) 2-3/8 (60) 3-1/2 (89) Page 18 Y8610U INTERMITTENT PILOT RETROFIT KIT 7 68-0291—03 INSTALLATION When Installing this Product… 1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condi- tion. 2.Check the ratings given in these instructions and on the product to ensure the product is suitable for your applica- tion. 3.Installer must be a trained, experienced service techni- cian. 4.After completing installation, use these instructions to check product operation. IMPORTANT 1. Installer must comply with local codes and ordinances of the National Fuel Code (ANSI Z223.1—NFPA No. 54) and National Electrical Code (ANSI NFPA No. 70). 2. Installer must fill in and attach label to appliance being converted. 3. Use Y8610 Retrofit Kit only with atmospheric burners. Do not use on direct vent appliances, appliances with induced draft, or power burners. 4. Do not use the Y8610 Retrofit Kit with mercury pilots or 250 to 750 mV pilot systems. WARNING FIRE OR EXPLOSION OR ELECTRICAL SHOCK HAZARD CAN CAUSE PROPERTY DAMAGE,SEVERE INJURY, OR DEATH. Follow these warnings exactly: 1. Disconnect the power supply before wiring to prevent electrical shock or equipment damage. 2. To avoid dangerous accumulation of fuel gas, turn off gas supply at the appliance service valve before starting Installation and perform the Gas Leak Test immediately following the installation. (See “Checkout” on page 15.) 3. Never install where water can flood, drip, or condense on module or gas control. Never use a module or gas control that has been wet. If wet, controls can malfunction and lead to an accumulation of explosive gas. 4. Do not light or operate electric switches, lights, or appliances until you are sure the appliance area is free of gas. Liquefied petroleum (LP) gas is heavier than air and does not vent upward naturally. Maintenance Requirements in Severe Environments Regular preventive maintenance is important in any application, but especially so in commercial cooking, agricultural, and industrial applications because: • In many such applications, particularly commercial cooking, the equipment operates 100,000-200,000 cycles per year. Such heavy cycling can wear out the gas control in one to two years. A normal forced air furnace, for which the controls were originally intended, typically operates less than 20,000 cycles per year. • Exposure to water, dirt, chemicals, and heat can damage the ignition control module or the gas control and shut down the control system. A NEMA 4 enclosure can reduce exposure to environmental contaminants. The maintenance program should include regular checkout of the system as outlined under “Checkout” on page 15. WARNING FIRE OR EXPLOSION HAZARDCAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Do not attempt to disassemble or clean the module. Improper reassembly and cleaning can cause unreliable operation. Maintenance frequency must be determined individually for each application based on: •Cycling frequency: Appliances that cycle more than 20,000 times annually should be checked monthly. •Intermittent use: Appliances that are used seasonally should be checked before shutdown and again before the next use. •Consequence of unexpected shutdown: Where the cost of an unexpected shutdown is high, the system should be checked more often. •Dusty, wet, or corrosive environment: Because these environments can cause the controls to deteriorate more rapidly, the system should be checked more often. Any ignition control module or gas control should be replaced if it does not perform properly on checkout or troubleshooting. In addition, replace any ignition control module or gas control if it is wet or looks like it has ever been wet. Protective enclosures as outlined under “Planning the Installation” on page 6 are recommended regardless of checkout frequency. Perform the Pre installation Safety Inspection The pre-installation checks described below must be completed before the Y8610U Intermittent Pilot Retrofit Kit is installed. If a condition that could result in unsafe operation is detected, the appliance should be shut off and the owner advised of the unsafe condition. Correct any potentially unsafe condition before proceeding with the installation. See “Exhibit A” on page 22. The following safety checklist should be followed in making the safety inspection: 1.Conduct a Gas Leakage Test of the appliance piping and control system downstream of the shut-off valve in the supply line to the appliance. 2.Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or restrictions, leakage or corrosion or other deficiencies which could cause an unsafe condition. 3.Shut off all gas to the appliance and shut off any other fuel-burning appliance within the same room. Use the shutoff valve in the supply line to each appliance. If a manual gas valve is not in the gas supply line within 6 feet of the appliance in an accessible location, one shall be installed. 4.Inspect burners and crossovers for blockage and corro- sion. Page 19 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 8 5.Applicable only to warm air heating appliances. Inspect heat exchangers for cracks, openings or excessive cor- rosion. 6.Applicable only to boilers. Inspect for evidence of water or combustion product leaks. 7.Insofar as is practical, close all building doors and win- dows and all doors between the space in which the appli- ance is located and other spaces of the building. Turn on clothes dryers. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. If, after completing steps 7 through 12, it is believed sufficient combustion air is not available, refer to 1.3.4 of the National Fuel Gas Code (Z223.1) for guidance. 8.Place in operation the appliance being inspected. Follow the lighting instructions. Adjust thermostat so appliance will operate continuously. 9.Determine the following: a. Determine that the pilot is burning properly and that main burner ignition is satisfactory by interrupting and re-establishing the electrical supply to the appli- ance in any convenient manner. b. Determine manifold pressure in order to match input after the new control is installed. 10.Perform the following tests: a. Visually determine that main burner gas is burning properly; i.e., no floating, lifting or flashback. Adjust the primary air shutter(s) as required. b. If appliance is equipped with high and low flame con- trol or flame modulation, check for proper main burner operation at low flame. 11.Test for spillage at the draft hood relief opening after 5 minutes of main burner operation. Use a draft gauge, the flame of a match or candle, or smoke from a cigarette, cigar or pipe. 12.Return doors, windows, exhaust fans, fireplace dampers and all other fuel-burning appliances to their previous conditions of use. 13.Applicable only to warm air heating appliances. Check both limit controller and fan controller for proper opera- tion. Limit controller operation can be checked by tempo- rarily disconnecting the electrical supply to the blower motor and determining that the limit control acts to shut off the main burner gas. 14.Applicable only to boilers: a. Determine that the circulating water pumps are in operating condition. b. Test low water cutoffs, automatic feed controls, pres- sure and temperature limit controls and relief valves in accordance with the manufacturer’s recommenda- tions and instructions to determine they are in oper- ating condition. Shut Down Appliance 1.Turn off the gas supply at the appliance service valve. Do not use the gas control knob. 2.Turn off the electricity at the service entrance. Check Appliance Wiring The existing standing pilot gas control wires are used to control Y8610U Retrofit Kit. Carefully identify and tag the wires before disconnecting. See Fig. 6 for the most common types of terminal arrangements. Fig. 6. Wiring connections on standing pilot gas controls. Remove Standing Pilot Gas Control 1.If the gas control has a common terminal(s), remove the wires connected to the common terminal(s) and splice together with one of the wire nuts provided. 2.Label and remove the remaining wires. WARNING FIRE OR EXPLOSION HAZARDCAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Do not bend the pilot gas tubing at the gas control or at the pilot burner to prevent gas leakage at the connection. 3.Disconnect the pilot tubing at the gas control. Cut off and discard the compression fitting. Do not disturb the com- pression fitting or pilot tubing at the pilot burner. 4.Disconnect the thermocouple lead at the gas control. 5.Disconnect the gas piping at the gas control. 6.Discard the gas control. TO TRANSFORMER TO THERMOSTAT TO TRANSFORMER TO THERMOSTAT TO TRANSFORMER TO THERMOSTAT COMMON COMMON M6858 Page 20 Y8610U INTERMITTENT PILOT RETROFIT KIT 9 68-0291—03 Remove Thermocouple Unscrew or snap the thermocouple out of the pilot burner and discard. See Fig. 7. NOTE: It could be necessary to pull out the main burner for access to the pilot burner. Do not move or relocate the pilot burner. Do not bend tubing near the pilot burner. Fig. 7. Remove thermocouple from pilot burner. Install Igniter-Sensor Assembly 1.Install the ground rod. See Fig. 8. • Mount adapter to the ground rod, if needed. • Insert the ground rod in place of the thermocouple on the pilot burner. Push the ground rod all the way up and fasten as shown in Fig. 8. • Align the ground rod so the clip hugs the pilot burner and keeps the ground rod from rotating. See Fig. 9. 2.Loosen the setscrews on the mounting bracket and slide the igniter-sensor mounting bracket over the top of the ground rod. See Fig. 9. 3.Tighten the setscrews on the mounting bracket using the hex wrench provided. See Fig. 9. 4.Adjust the electrode position so the electrode tip and gap are in the pilot flame. Push/pull the ground rod to move the igniter-sensor up and down. 5.Check that the chosen position allows room to connect the ignition cable to the stud terminal. Rotate the igniter- sensor as necessary. 6.Tighten the setscrews on the mounting bracket using the hex wrench provided. Fig. 8. Mount ground rod on pilot burner. Fig. 9. Fasten igniter-sensor to ground rod. M6862 REMOVE THERMOCOUPLE PILOT BURNER PILOT TUBING BE SURE THE GROUND CLIP IS SNAPPED ONTO THE PILOT BURNER OR ITS GAS LINE. M24902 SLIP NUT OFF ADAPTER AND CLAMP GROUND ROD IN PILOT WITH SHOULDER ABOVE CLAMP AS SHOWN CLAMP TYPE ADD ADAPTER, INSERT GROUND ROD IN PILOT SCREW-IN TYPE TIGHTEN NUT PUSH-IN TYPE INSERT GROUND ROD M6863A GROUND ROD GROUND ROD CLIP ELECTRODE SETSCREW (2) ELECTRODE GAP IGNITER-SENSOR STUD TERMINAL MOUNTING BRACKET PILOT BURNER PILOT GAS TUBING ELECTRODE Page 21 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 10 Install the Gas Control WARNING FIRE OR EXPLOSION HAZARDCAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Follow these warnings exactly: 1. Do not bend the pilot gas tubing at the gas control or at the pilot burner after the compression fitting is tightened. Gas leakage at the connection can result. 2. Always install a sediment trap in the gas supply line to prevent contamination of the gas control. 3. Do not force the gas control knob. Use only your hand to turn the gas control knob. If the gas control knob does not operate by hand, the gas control should be replaced by a qualified service techni- cian. Force or attempted repair can result in a fire or explosion. IMPORTANT These gas controls are shipped with protective seals over the inlet and outlet tappings. Do not remove the seals until ready to connect the piping. Converting Between Natural and LP Gas WARNING FIRE OR EXPLOSION HAZARDCAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. 1. Do not attempt to use a gas control set for natural gas on LP gas or a gas control set for LP gas on natural gas. 2. When making a conversion, main and pilot burner orifices must be changed to meet appliance manu- facturer specifications. To convert from natural gas to LP, use the 393691 LP Conversion Kit that is included with the Y8610U Intermittent Pilot Retrofit Kit. To convert from LP to natural gas, use the 394588 Natural Gas Conversion Kit (ordered separately). Step-opening gas controls cannot be converted. To convert control from one gas to another: 1.Turn off the main gas supply to the appliance. 2.Remove the regulator cap screw and pressure regulator adjusting screw. See Fig. 3 or Fig. 4 on page 5. 3.Remove the existing spring. 4.Insert the replacement spring with the tapered end down. See Fig. 10. 5.Install the new plastic pressure regulator adjustment screw so that the top of the screw is flush (level) with the top of the regulator. Turn the pressure regulator adjust- ment screw clockwise six complete turns. This provides a preliminary pressure setting of about 10.0 in. wc (2.5 kPa) for LP regulator and 3.5 in. wc (0.9 kPa) for natural gas regulator. 6.Check the regulator setting either with a manometer or by clocking the gas meter. See “Checkout” on page 15. 7.Install the new cap screw. 8.Mount the conversion label on the control. 9.Install the control and appliance according to the appli- ance manufacturer instructions. Fig. 10. Installation of conversion kit in regulated gas control. Install Adapters to Gas Control (if used) 393690-14 Straight Flange (3/4 in.) 1.Remove the seal over the gas control inlet or outlet. 2.Make sure that the O-ring is fitted in the flange groove. If the O-ring is not attached or is missing, do not use the flange. 3.With the O-ring facing the gas control, align the gas con- trol threaded holes with the flange clearance holes. 4.Insert and tighten the screws provided with the flange. Tighten the screws to 25 inch pounds of torque to pro- vide a gas tight seal. Bushings 1.Remove the seal over the gas control inlet or outlet. 2.Apply a moderate amount of good quality pipe com- pound to the bushing, leaving the two end threads bare. For an LP installation, use a compound resistant to LP gas. Do not use Teflon tape. 3.Insert the bushing in the gas control and thread the pipe carefully into the bushing until tight. Install Gas Control Piping All pipe must comply with local codes and ordinances or with the National Fuel Code (ANSI Z223.1 NFPA No. 54), whichever applies. Tubing installation must comply with approved standards and practices. 1.Use new, properly reamed pipe free from chips. If tubing is used, ensure that ends are square, deburred, and clean. All tubing bends must be smooth and without deformation. 2.Run the new pipe or tubing to the gas control. When tub- ing is used, obtain a tube-to-pipe coupling to connect the tubing to the gas control. 3.Install a sediment trap in the gas supply line. See Fig. 11 on page 11. COLOR CODE FOR LP GAS NATURAL GAS CAP SCREW BLACK SILVER PRESSURE REGULATOR ADJUSTING SCREW WHITE WHITE SPRING RED STAINLESS STEEL PRESSURE REGULATOR HOUSING M8083A Page 22 Y8610U INTERMITTENT PILOT RETROFIT KIT 11 68-0291—03 Fig. 11. Install sediment trap. Mount Gas Control 1.The gas control can be mounted from 0 to 90 degrees, in any direction including vertically, from the upright posi- tion of the gas control knob. 2.Mount the gas control so the gas flow is in same direc- tion as the arrow on the gas control bottom. 3.Thread the pipe as listed in Table 3. NOTE: See Table 3 for maximum pipe threading depth. If the pipe is inserted too deeply into the gas control, the second main valve or safety valve can distort or mal- function. 4.Apply a moderate amount of good quality pipe com- pound to pipe only; leave the two end threads bare. Do not use teflon tape. In LP installations, use a compound resistant to LP gas. See Fig. 12. Fig. 12. Use moderate amount of pipe compound. 5.Remove protective seals over the gas control inlet and outlet, if necessary. 6.Connect the pipe to the gas control inlet and outlet. Tighten the inlet and outlet connections using a wrench on the gas control projecting wrench boss. See Fig. 3 or Fig. 4 on page 5 depending on the valve used. Connect Pilot Gas Tubing 1.Cut the pilot gas tubing and bend as necessary for rout- ing to the pilot burner. • Do not make sharp bends or deform the tubing. • Do not bend the tubing at the gas control after the compression nut has been tightened; gas leakage at the connection can result. 2.Square off and remove the burrs from the tubing end. 3.Unscrew the brass compression fitting from pilot gas out- let (see Fig. 3 or Fig. 4 on page 5 depending on the valve used). Slip the fitting over the pilot gas tubing and slide out of the way. NOTE: When replacing a gas control, cut off the old compres- sion fitting and replace with the new compression fit- ting provided on the new gas control. Never use the old compression fitting as it might not provide a gas tight seal. See Fig. 13. Fig. 13. Always use new compression fitting. 4.Push pilot gas tubing into the pilot gas tapping until it bot- toms. While holding the tubing all the way in, slide the compression fitting into place and engage the threads. Turn the fitting until finger tight. Use a wrench to tighten one more turn. Do not overtighten. 5.Connect the other end of the pilot gas tubing to the pilot burner according to the pilot burner manufacturer instructions. Table 3. NPT pipe thread length (in.) Pipe Size Overall Thread Length Maximum Depth Pipe Can Be Inserted Into Gas Control 3/8 9/16 3/8 1/2 3/4 1/2 3/4 13/16 3/4 GAS CONTROL GAS CONTROL HORIZONTAL DROP PIPED GAS SUPPLY PIPED GAS SUPPLY 3 IN. (76 MM) MINIMUM 3 IN. (76 MM) MINIMUM RISER GAS CONTROL TUBING GAS SUPPLY HORIZONTAL DROP 3 IN. (76 MM) MINIMUM RISER M3077A 2 1 2 2 1 2 ALL BENDS IN METALLIC TUBING SHOULD BE SMOOTH. CAUTION: SHUT OFF THE MAIN GAS SUPPLY BEFORE REMOVING END CAP TO PREVENT GAS FROM FILLING THE WORK AREA. TEST FOR GAS LEAKAGE WHEN INSTALLATION IS COMPLETE. TWO IMPERFECT THREADS GAS CONTROL THREAD PIPE CORRECT LENGTH APPLY A MODERATE AMOUNT OF PIPE COMPOUND TO PIPE ONLY (LEAVE TWO END THREADS BARE).M3312 PIPE GAS CONTROL TIGHTEN NUT ONE TURN BEYOND FINGER TIGHT FITTING BREAKS OFF AND CLINCHES TUBING AS NUT IS TIGHTENED PILOT TUBING M6868A Page 23 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 12 Locate and Mount the S8610U Intermittent Pilot Module Location Identify a mounting location for the S8610U ignition control. The mounting location must provide: — Good, clear access to the field wiring terminals. — Operating ambient temperatures between -40°F (-40°C) and 165°F (74°C). — Direct the cable route to the pilot burner. The cable route must be 30 inches (762 mm) or less and not expose the cable to excessive heat. — Relative humidity below 95% non condensing. — Protection from water, steam or corrosive chemicals that are used to clean the appliance. — Protection from dripping water, such as from an overfilled humidifier or from condensation. — Protection from dust or grease accumulation. Mounting Mount the ignition control module with the terminals down to protect them from dripping water and dust. The control module can also be mounted with the terminals on either side. Do not mount with the terminals pointing up. Fig. 14 illustrates the incorrect mounting position. Use the S8610U as a template to mark the mounting hole pattern. Drill new holes, as required. Fasten securely with four – No. 6-32 machine screws, or No. 8 sheet metal screws, or 8-18 x 5/8 Pan Head tapping screws. IMPORTANT Do not mount with terminals facing up. Fig. 14. Incorrect mounting. Wire the System CAUTION ELECTRICAL SHOCK OR EQUIPMENT DAMAGE HAZARD. Disconnect the power supply before making wiring connections to prevent electrical shock or equipment damage. All wiring must comply with local codes and ordinances. Refer to Fig. 15 and Table 5 on page 13 for typical connections. IMPORTANT 1. As shown in the wiring diagrams, a common ground is required on: The pilot burner mounting bracket, and the GND (BURNER) terminal on the ignition control module. Failure to use the GND (BURNER) terminal may result in intermittent loss of spark and/or loss of flame current sensitivity. 2. Make sure the transformer has adequate VA. The ignition control module requires at least 0.1 A at 24 Vac. Add the current draws of all other devices in the control circuit, including the pilot and main valves in the gas control, and multiply by 24 to determine the total VA requirement of these components. Add this total to 2.4 VA (for the ignition control module). The result is the minimum transformer VA rating. Use a Class II transformer if replacement is required. Connect Vent Damper (Optional) If the ignition control module is to be used with an existing vent damper and harness to be connected to the module’s integral damper connector in an atmospheric appliance, perform the following to connect it to the module: IMPORTANT After the initial power-up, the ignition control module senses the presence of the vent damper connection. If the vent damper is connected, the ignition control module permanently configures itself to operate only with the damper connected. Once an ignition control module powers up with a vent damper connected, the module will not function without a vent damper being connected. Using the wiring harness on the appliance, insert the matching 6-pin plug into the connector labeled P1 (see Fig. 15 on page 13) on the S8610U ignition control module and connect the other end to the vent damper. NOTE: The connector (P1) accepts a Molex 03-06-2061 plug on the existing vent damper harness. M29889 Page 24 Y8610U INTERMITTENT PILOT RETROFIT KIT 13 68-0291—03 Connect Ignition Cable Use the provided ignition cable to connect the S8610U module to the pilot burner. Be sure the ignition cable is not exposed to high temperature while the appliance is operating. NOTE: The cable must not run in continuous contact with a metal surface or spark voltage may be greatly reduced. Use ceramic or plastic standoff insulators as required. To install: 1.Connect one end of the cable to the male quick connect SPARK terminal on the ignition module. 2.Connect the other end of the cable to the igniter or igniter-sensor stud on the pilot burner/igniter-sensor. Wiring Connections Connect the provided harness to the ignition module and the gas control. The harness ends are labeled for easy installation. See Table 4. Use Fig. 15 and Table 5 to make the remaining wiring connections. NOTE: The 24V terminal on the S8610U is used only when a vent damper is installed. Fig. 16 on page 14 illustrates the typical wiring connections in a heating system with an atmospheric burner. Fig. 15. S8610U Typical wiring connections. Table 4. Wiring Harness Connections. Harness Wire Color / Wire Label S8610U Terminal Gas Control Terminal / Tstat Load Black / 25 VAC TH-W Thermostat call for heat to original standing pilot valve Orange / 25 VAC-GND 24V (GND) Transformer 24 VAC ground lead to original standing pilot valve Red / MV MV MV White / MV-PV MV-PV MV-PV Blue / PV PV PV Green / GND GND Ground terminal on gas control Table 5. S8610U Typical Wiring Connections. Connector Label Size or Type Description MV 1/4 inch Main Valve connection MV/PV 1/4 inch Common terminal for gas valves PV 1/4 inch Pilot Valve connection BRN GND 1/4 inch Burner Ground 24V GND 1/4 inch Return path to transformer 24V 1/4 inch Optional— 24 Vac power connection for Vent Damper TH-W 1/4 inch Connector for “Call for Heat” signal from thermostat P1 6-pin keyed plug Connector for Vent Damper connection (used to control a connected damper in atmospheric appliances) Flame Current Two holes Micro-ammeter connector P4 (Jumper) Jumper Provides a lockout for the DIP switch settings (See “Jumper” on page 15.) SENSE JUMPER WIRE Wire with 3/16 inch quick connect Connects to the REMOTE SENSE connector for installations with a single spark rod (local flame sensing) REMOTE SENSE 3/16 inch Flame Sensor connector For single rod installations, connect the SENSE JUMPER WIRE to this terminal connector. SPARK 1/4 inch High voltage sparking electrode connection SPARK MV 24V GND MV/PV PV BRN/GND REMOTE SENSE TH-W (OPT.) 24V (OPT.) M29890 SENSE JUMPER WIRE P1 VENT DAMPER CONNECTOR Page 25 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 14 Fig. 16. Y8610U connections in a heating system with an atmospheric burner and no vent damper. SETTINGS DIP Switch (S1) Settings The factory default settings for the S8610U are recommended for retrofit applications. These settings will provide the most reliable system operation. Fig. 17. DIP switch (S1) - shown with factory default settings (OFF) for SW1 and SW2. Fig. 18. DIP switch (S1) and jumper (P4) location. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. ALTERNATE LIMIT CONTROLLER LOCATION. MAXIMUM CABLE LENGTH 3 FT. [0.9 M]. CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER. LEAVE VENT DAMPER PLUG (P1) UNCONNECTED. CONNECT JUMPER WIRE TO THE REMOTE SENSE CONNECTOR.M32356 1 2 3 4 5 6 THERMOSTAT L1 (HOT) L2 LIMIT CONTROLLER PILOT BURNER GROUND SPARK S8610U REMOTE SENSEMV MV/ PV PV GND (BRN) 24V GND 24V TH-W P1 5 3 6 2 4 1 PILOT GAS SUPPLY PILOT BURNER/ IGNITER JUMPER WIRE VR8204 COMBINATION GAS CONTROL PV PV/MV MV Table 6. DIP Switch (S1) Settings. Prepurge Trial For Ignition SW1 SW2 None 90 seconds OFF OFF ON 1 2 S1 M23587 M29894 S1 DIP SWITCH Page 26 Y8610U INTERMITTENT PILOT RETROFIT KIT 15 68-0291—03 Jumper This jumper (labeled P4) is used to lock the operating sequence selected by the DIP switch settings. See Fig. 18. IMPORTANT Once the Jumper has been pulled or the module starts the 10th “Call for Heat”, the control operating sequence is permanently locked and cannot be reset by replacing the jumper or by resetting the Dip Switches. CHECKOUT Check out the gas control system: • At initial appliance installation. • As part of regular maintenance procedures. Maintenance intervals are determined by the application. See “Planning the Installation” on page 6. • As the first step in troubleshooting. • Anytime work is done on the system. WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. 1. If you smell gas or suspect a gas leak, turn off the gas at the manual service valve and evacuate the building. Do not try to light any appliance and do not touch any electrical switch or telephone in the building until no spilled gas remains. 2. A gas leak test must be done as described in the steps below on initial installation and any time work is done involving the gas piping. Step 1: Perform Visual Inspection. 1.With power off, make sure all wiring connections are clean and tight. 2.Turn on power to appliance and ignition control module. 3.Open manual shutoff valves in the gas line to the appli- ance. 4.Perform a gas leak test ahead of the gas control. GAS LEAK TEST: Paint the gas control gasket edges and all pipe connections upstream of the gas control with a rich soap and water solution. Bubbles indicate gas leaks. Tighten the joints and screws or replace component to stop gas leak. Recheck with soap and water solution. Step 2: Verify Ignition Control System Ground. The igniter, flame sensor, and ignition control module must share a common ground with the pilot burner. Use thermoplastic insulated wire with a minimum rating of 221°F (105°C) for the ground wire; asbestos insulation is not acceptable. If the temperature at the wire could exceed 221°F (105°C), use a shield to protect the wire from radiant heat generated by the burner. Connect the ground wire as follows: 1.Fit one end of the ground wire with a female 1/4 in. quick-connect terminal and connect it to the male quick-connect GND (BURNER) terminal on the ignition control module. 2.Strip the other end of the wire and fasten it under the igniter bracket mounting screw. If necessary, use a shield to protect the ground wire from radiant heat. 3.The burner serves as the common grounding area. If there is not good metal-to-metal contact between the burner and ground, run a lead from the burner to ground. NOTE: Earth ground is not required. Step 3: Review Normal Operating Sequence and Ignition Control Module Specifications. See the Operation section on this page and “Specifications” on page 2. Step 4: Reset the Ignition Control Module. 1.Turn the thermostat to its lowest setting. 2.Wait one minute. As you perform the remaining steps, watch for points where operation deviates from normal. To correct problems, refer to the “Troubleshooting Guide” on page 21. Step 5: Check Safety Shutoff Operation. 1.Turn gas supply off at the appliance manual shutoff valve. 2.Set thermostat or controller above room temperature to “Call for Heat.” 3.Watch for spark at pilot burner. Time spark from start to shutoff. Spark should shut off after 90 seconds. See device label and “Settings” on page 14. 4.Wait 5 minutes. Ignition sequence should start again fol- lowed by shutoff. 5.Set thermostat below room temperature and wait one minute before continuing. Step 6: Check Normal Operation. 1.Turn on the gas supply at the appliance manual shutoff valve. 2.Turn gas control knob to ON and make sure that no gas is flowing to the pilot or main burner. 3.Set thermostat or controller above room temperature to “Call for Heat.” 4.Make sure pilot lights smoothly when gas reaches the pilot burner. 5.Make sure main burner lights smoothly without flash- back. 6.Make sure burner operates smoothly without floating, lift- ing, or flame rollout to the furnace vestibule or heat buildup in the vestibule. Table 7. Jumper Usage. Jumper Action to lock the control’s operating sequence P4 To ensure proper system operation (after installation and checkout), pull jumper to lock the DIP switch settings. NOTE: If jumper is not removed during installa- tion, the ignition control locks the DIP switch settings after the 10th “Call for Heat” cycle. Page 27 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 16 7.Perform a gas leak test in the appliance including both the inlet and outlet sides of the gas control. GAS LEAK TEST: Paint the gas control gasket edges and all pipe connections downstream of the gas control, including the pilot tubing connections, with a rich soap and water solution. Bubbles indicate gas leaks. Tighten the joints and screws or replace component to stop gas leak. Recheck with soap and water solution. 8.Turn the thermostat or controller below the room temper- ature. Make sure the main burner and pilot flames go out. OPERATION Fig. 19 summarizes the normal operating sequence for installations without vent dampers. The ignition control module’s operation can be conveniently divided into two phases. • Trial for pilot ignition • Main burner operation Trial for Pilot Ignition On a “Call for Heat”, the ignition control module energizes the spark source and the pilot valve relay simultaneously. The pilot valve opens, allowing gas to flow to the pilot burner for the ignition trial time. The spark lights the pilot flame when pilot gas is present. A flame rectification circuit confirms the presence of the pilot flame, shuts off the spark source, and energizes the main valve relay. The ignition control module uses a two-level pilot flame proving sequence. When a sufficient flame current is sensed, the spark is turned OFF. However, the pilot flame must generate a higher level of flame current to energize the main valve. This approach assures a stable pilot flame to support reliable burner lightoff. If the pilot flame is weak or unstable, the spark may turn back ON. However, the trial for pilot ignition will not exceed the stated ignition trial time. Main Burner Operation When the main valve opens, gas flows to the main burner where it is lit by the pilot flame. There is a short flame stabilization period as the main valve opens to allow the pilot flame to stabilize as the main gas lights. The system is now in the run mode with the presence of the pilot flame continuously monitored by the flame rectification circuit. If the pilot flame goes out, the ignition control module senses loss of pilot flame and shuts off both the pilot valve relay and the main valve relay. Flow of gas to pilot and main burners stops as the valves close (100% shutoff). Failed Trial for Pilot Ignition The S8610U control module provides multiple trials for ignition (TFI). If the pilot is not lit or sensed before the end of the trial for ignition time, the ignition control shuts off the spark and pilot gas (100% shutoff). There is a five minute delay before another TFI is initiated. The pattern of TFI followed by a five minute delay continues until the pilot lights and is proved or the “Call for Heat” ends. The five minute delay time can be bypassed by cycling the system thermostat or removing and restoring system power. Fig. 19. Normal operating sequence without vent damper. OPERATING SEQUENCE “CALL FOR HEAT” RECEIVED FROM THERMOSTAT POWER TO MODULE AND SELF CHECK IDLE (NOT POWERED) RUN YES TRIAL FOR IGNITION (TIMER STARTED) SPARK ON OPEN PILOT GAS VALVE FLAME PROVED? FLAME STABILIZATION (2 SECONDS) YES NO RETRY OPEN MAIN GAS VALVE CLOSE MAIN GAS VALVE AND PILOT GAS VALVE FLAME LOST? NO CLOSE PILOT GAS VALVE SPARK OFF “CALL FOR HEAT” ENDS? YES NO RETRY DELAY (5 MINUTES) SPARK OFF MORE THAN 5 FLAME LOSSES IN THIS “CALL FOR HEAT”? (BEFORE TRIAL FOR IGNITION TIMER EXPIRES) A CLOSE MAIN GAS VALVE AND PILOT GAS VALVE BA M24903 NO B YES Page 28 Y8610U INTERMITTENT PILOT RETROFIT KIT 17 68-0291—03 TROUBLESHOOTING WARNING Fire, Explosion, or Electrical Shock Hazard. Can cause severe injury, death or property damage. Do not attempt to modify the physical or electrical characteristics of this device in any way. Replace it if troubleshooting indicates a malfunction. IMPORTANT 1. The following service procedures are provided as a general guide. Follow appliance manufacturer’s ser- vice instructions if available. 2. Meter readings between the gas control and ignition control module must be taken within the trial for igni- tion period. Once the ignition control module shuts off, it must be reset by setting the thermostat down for at least 30 seconds before continuing. 3. If any component does not function properly, make sure it is correctly installed and wired before replacing it. 4. The ignition control module and the gas control can- not be repaired. If either malfunctions, it must be replaced. 5. Only trained, experienced service technicians should service intermittent pilot systems. 6. After troubleshooting, check out the system again to be sure it is operating normally. Troubleshooting Sequence The general troubleshooting sequence is as follows: 1.Refer to “LED Status and Troubleshooting” on page 19 for LED status codes. 2.Perform the “Checkout” on page 15 as the first step in troubleshooting. 3.Check the Troubleshooting Guide (Fig. 22 on page 21) to pinpoint the cause of the problem. 4.If troubleshooting indicates an ignition problem, see Igni- tion System Checks below to isolate and correct the problem. 5.Following troubleshooting, perform the “Checkout” on page 15 again to be sure system is operating normally. Ignition System Checks Step 1: Check Ignition Cable. Make sure: 1.Ignition cable is not damaged, cracked, burned, or dirty. Replace if necessary. 2.Ignition cable does not run in contact with any metal sur- faces. 3.Ignition cable is no more than 36 in. (0.9 m) long. 4.Connections to the ignition control module and to the igniter or igniter-sensor are clean and tight. 5.Ignition cable provides good electrical continuity. STEP 2: Check Ignition System Grounding. Nuisance shutdowns are often caused by a poor or erratic ground. A common ground, is required for the ignition control module and the pilot burner bracket. 1.Check for good metal to metal contact between the pilot burner bracket and the main burner. 2.Check the ground circuit from the GND (BURNER) termi- nal on the ignition control module to the pilot burner. Make sure connections are clean and tight. If the wire is damaged or deteriorated, replace it with 14 to 18-gauge, moisture-resistant, thermoplastic insulated wire with 221°F (105°C) minimum rating. a. Check the ceramic flame rod insulator for cracks or evidence of exposure to extreme heat, which can permit leakage to ground. Replace pilot burner/ igniter-sensor and provide shield, if necessary. b. If the flame rod or bracket is bent out of position, restore to correct position. STEP 3: Check Spark Ignition Circuit. You will need a short jumper wire made from ignition cable or other heavily insulated wire. 1.Close the manual gas valve. 2.Disconnect the ignition cable at the SPARK terminal on the ignition control. WARNING Electrical Shock Hazard. Can cause severe injury, death or property damage. When performing the following steps, do not touch the stripped end of jumper or SPARK terminal. The ignition circuit generates over 10,000 volts and electrical shock can result. 3.Energize the ignition control module and immediately touch one end of the jumper firmly to the GND terminal on the ignition control module. Move the free end of the jumper slowly toward the SPARK terminal until a spark is established. 4.Pull the jumper slowly away from the terminal and note the length of the gap when sparking stops. Check Table 8. Table 8. Arc Troubleshooting. Arc Length Action No arc or arc less than 1/8 in. (3 mm) Check external fuse, if provided. Verify power at the ignition control module’s control input terminal. Replace control if fuse and power are okay. Arc 1/8 in. (3 mm) or longer Voltage output is okay. Page 29 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 18 STEP 4: Check Pilot and Main Burner Lightoff. 1.Set the thermostat to “Call for Heat.” 2.Watch the pilot burner during the ignition sequence. See if one of the following occurs: a. Ignition spark continues after the pilot is lit. b. The pilot lights and the spark stops, but main burner does not light. c. The pilot lights, the spark stops and main burner lights, but the pilot and main gas shut down while the “Call for Heat” is still present. 3.If so, ensure adequate flame current as follows. a. Turn off furnace at circuit breaker or fuse box. b. Clean the flame rod with emery cloth. c. Make sure electrical connections are clean and tight. Replace damaged wire with moisture-resistant No. 18 wire rated for continuous duty up to 221°F (105°C). d. Check for cracked ceramic insulator, which can cause short to ground, and replace igniter-sensor if necessary. e. Check for cracked, damaged, burned, or dirty spark ignition cable and replace if necessary. Be sure igni- tion cable is not touching any flat metal surface. f. At the gas control, disconnect main valve wire from the TH-W or MV terminal. g. Turn on power and set thermostat to “Call for Heat.” The pilot should light but the main burner will remain off because the main valve actuator is disconnected. h. Check the pilot flame. Make sure it is blue, steady and envelops 3/8 to 1/2 in. (10 to 13 mm) of the flame rod. See Fig. 20 for possible flame problems and their causes. i. If necessary, adjust pilot flame by turning the pilot adjustment screw on the gas control clockwise to decrease or counterclockwise to increase pilot flame. Following adjustment, always replace pilot adjust- ment cover screw and tighten firmly to assure proper gas control operation. j. Set thermostat below room temperature to end “Call for Heat.” 4.Recheck ignition sequence as follows. a. Reconnect main valve wire. b. Set thermostat to “Call for Heat.” c. Watch ignition sequence at burner. d. If spark still doesn’t stop after pilot lights, replace ignition control module. e. If main burner doesn’t light or if main burner lights but system locks out, check the ignition control module’s ground wire and the gas control as described in “Igni- tion System Checks” on page 17 and refer to the Troubleshooting Guide (Fig. 22 on page 21). Fig. 20. Examples of unsatisfactory pilot flames. LAZY YELLOW FLAME WAVING BLUE FLAME NOISY LIFTING BLOWING FLAME HARD SHARP FLAME SMALL BLUE FLAME CHECK FOR LACK OF GAS FROM: • CLOGGED ORIFICE FILTER • CLOGGED PILOT FILTER • LOW GAS SUPPLY PRESSURE • PILOT ADJUSTMENT AT MINIMUM CHECK FOR LACK OF AIR FROM: • DIRTY ORIFICE • DIRTY LINT SCREEN, IF USED • DIRTY PRIMARY AIR OPENING, IF THERE IS ONE • PILOT ADJUSTMENT AT MINIMUM CHECK FOR: • EXCESSIVE DRAFT AT PILOT LOCATION • RECIRCULATING PRODUCTS OF COMBUSTION CHECK FOR: • HIGH GAS PRESSURE THIS FLAME IS CHARACTERISTIC OF MANUFACTURED GAS CHECK FOR: • HIGH GAS PRESSURE • ORIFICE TOO SMALL M2233B APPEARANCE CAUSE Page 30 Y8610U INTERMITTENT PILOT RETROFIT KIT 19 68-0291—03 LED Status and Troubleshooting The ignition control module has two LEDs; one for flame sensing and one for system status: Fig. 21. Location of LEDs. • Flame Status and Sense LED — Indicates system operation status and senses error conditions. See Table 9 on page 20 and the “Trouble- shooting Guide” on page 21. M29896STATUS LED Page 31 Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 20 a Flash Code Descriptions: - Flash Fast: rapid blinking. - Heartbeat: Constant ½-second bright, ½-second dim cycles. - 4-second solid on pulse followed by “x” 1-second flashes indicates flame current to the nearest μA. This is only available in run mode. - A single flash code number signifies that the LED flashes X times at 2 Hz, remains off for two seconds, and then repeats the sequence. Table 9. Green LED Status Codes. Green LED Flash Codea Indicates Next System Action Recommended Service Action OFF No “Call for Heat” Not applicable None Flash Fast Power up - internal check Not applicable None Heartbeat Normal startup - ignition sequence started (including prepurge) Not applicable None 4 Seconds ON then “x” flashes Device in run mode. “x” = flame current to the nearest μA. Not applicable None 2 5 minute Retry Delay – Pilot flame not detected during trial for ignition Initiate new trial for ignition after retry delay completed. If system fails to light on next trial for ignition check gas supply, pilot burner, spark and flame sense wiring, flame rod contaminated or out of position, burner ground connection. 3 Recycle – Flame failed during run Initiate new trial for ignition. Flash code will remain through the ignition trial until flame is proved. If system fails to light on next trial for ignition, check gas supply, pilot burner, flame sense wiring, contamination of flame rod, burner ground connection. 4 Flame sensed out of sequence If situation self corrects within 10 seconds, control module returns to normal sequence. If flame out of sequence remains longer than 10 seconds, control will resume normal operation 1 hour after error is corrected. Check for pilot flame. Replace gas valve if pilot flame present. If no pilot flame, cycle “Call for Heat.” If error repeats, replace control. 5 Damper Error: – Damper required but not present – Damper failed to open within 60 seconds – Damper failed to close within 60 seconds If damper error corrects, ignition control resumes normal operation. Check damper connection, damper wiring, and 24V connection on control. Replace damper if necessary. 6 Control Internal Error Control module remains in wait mode. When the fault corrects, control module resumes normal operation. Cycle “Call for Heat.” If error repeats, replace control. 7 Flame rod shorted to ground Control module remains in wait mode. When the fault corrects, control module resumes normal operation. Check flame sense lead wire for damage or shorting. Check that flame rod is in proper position. Check flame rod ceramic for cracks, damage or tracking. 8 Low secondary voltage supply Control module remains in wait mode. When the fault corrects, control module resumes normal operation. Check transformer and AC line for proper input voltage to the control. Check with full system load on the transformer. Page 32 Y8610U INTERMITTENT PILOT RETROFIT KIT 21 68-0291—03 Troubleshooting Guide Refer to the Fig. 22 for troubleshooting the S8610U control module. Fig. 22. Troubleshooting Guide. POWER TO TH-W TERMINAL? (NOMINAL 24 V ) PILOT BURNER LIGHTS? SPARK STOPS WHEN PILOT IS LIT? MAIN BURNER LIGHTS? SYSTEM RUNS UNTIL “CALL FOR HEAT” ENDS? “CALL FOR HEAT” ENDS SYSTEM SHUTS OFF? REPEAT PROCEDURE UNTIL TROUBLE FREE OPERATION IS OBTAINED CHECK IGNITION CABLE, GROUND WIRING, CERAMIC INSULATOR, AND GAP AND CORRECT. CHECK BOOT OF THE IGNITION CABLE FOR SIGNS OF MELTING OR BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES. CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING AND GAS PRESSURES ARE TO SPECIFICATION, AND PILOT BURNER ORIFICE IS NOT BLOCKED. CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL. CHECK FOR 24 VAC ACROSS PV-MV/PV TERMINALS ON MODULE. IF VOLTAGE IS OKAY, REPLACE GAS CONTROL. IF NOT, REPLACE MODULE. NOTE: IT MAY BE NECESSARY TO RECYCLE THE “CALL FOR HEAT” TO CLEAR THE PILOT SUPPLY TUBING OF AIR. CHECK FOR 24 VAC ACROSS PV-MV/PV TERMINALS ON MODULE. IF NO VOLTAGE, REPLACE MODULE. CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS CONTROL. IF OKAY, REPLACE GAS CONTROL. CHECK FOR PROPER THERMOSTAT (CONTROLLER) OPERATION. REMOVE MV LEAD AT MODULE. IF VALVE CLOSES, RECHECK TEMPERATURE CONTROLLER AND WIRING. IF NOT, REPLACE GAS CONTROL. SPARK OK? NO NO NO NO NO NO NO YES YES YES YES YES YES YES REPLACE MODULE. YES NOTE: 24 VAC “CALL FOR HEAT” IS ALWAYS CONNECTED TO THE TH-W TERMINAL ON THE MODULE. START: BEFORE TROUBLESHOOTING, FAMILIARIZE YOURSELF WITH THE STARTUP AND CHECKOUT PROCEDURES. TURN THERMOSTAT (CONTROLLER) TO “CALL FOR HEAT” CHECK LINE VOLTAGE POWER, LOW VOLTAGE TRANSFORMER, LIMIT CONTROLLER, THERMOSTAT (CONTROLLER), AND WIRING. ALSO, CHECK AIR PROVING SWITCH ON COMBUSTION AIR BLOWER SYSTEM (IF USED) AND THAT THE END SWITCH (IF USED) IS MADE. SPARK ACROSS IGNITER/ SENSOR GAP? PULL IGNITION LEAD AND CHECK SPARK AT MODULE. TURN GAS SUPPLY ON AND RECYCLE “CALL FOR HEAT” NOTE: IF MODULE GOES INTO RETRY DELAY, RESET THE “CALL FOR HEAT.” CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE. CLEAN FLAME ROD. CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROD AND MODULE. CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY AND BLUE. ADJUST PILOT FLAME IF NECESSARY. IF PROBLEM PERSISTS, REPLACE MODULE. NOTE: IF MODULE GOES INTO RETRY DELAY, RESET THE “CALL FOR HEAT.” CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE. NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWNS MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT. CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY AND BLUE. ADJUST PILOT FLAME. IF CHECKS ARE OKAY, REPLACE MODULE. M24904 TURN GAS SUPPLY OFF NO RECYCLE “CALL FOR HEAT“ TO ALLOW TIME TO CHECK SPARK. Page 33