HomeMy WebLinkAboutB14-0264_Fisher firestop submittal 11-18-15_1447973760.pdfHilti Firestop Systems Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • en español 1-800-879-5000 • P.O. Box 21148, Tulsa, Oklahoma 74121 Hilti (Canada) Corp. 1-800-363-4458 www.hilti.ca • 2360 Meadowpine Blvd., Mississauga, Ontario L5N 6S2 Hilti. Outperform. Outlast. Firestop Submittal Package Project: Date: Submitted by: Hilti Firestop Saving lives through innovation and education This submittal is auto-generated based on user-selected inputs. Therefore, Hilti makes no representation as to the suitability of these systems for their intended use. Table Of Contents UL Listings C-AJ-1154.............................................................................................................................................1 C-AJ-2098 (US Only)............................................................................................................................2 C-AJ-2167 (US Only)............................................................................................................................3 C-AJ-2170 (US Only)............................................................................................................................4 C-AJ-2305 (US Only)............................................................................................................................5 C-AJ-2335 (US Only)............................................................................................................................6 C-AJ-3095.............................................................................................................................................7 C-AJ-5096.............................................................................................................................................9 C-AJ-7051...........................................................................................................................................11 C-AJ-7084...........................................................................................................................................12 C-AJ-8099...........................................................................................................................................13 C-AJ-8148...........................................................................................................................................15 W-L-1054............................................................................................................................................17 W-L-2075 (US Only)...........................................................................................................................19 W-L-2128 (US Only)...........................................................................................................................20 W-L-3065............................................................................................................................................21 W-L-3310............................................................................................................................................23 W-L-5096............................................................................................................................................24 W-L-7042............................................................................................................................................26 W-L-7096............................................................................................................................................27 W-L-7153............................................................................................................................................28 W-L-7156............................................................................................................................................30 W-L-8004 (US Only)...........................................................................................................................32 CFS-S SIL GG Product Data Sheet for CFS-S SIL GG Firestop Silicone Sealant......................................................34 UL Certificate of Compliance for CFS-S SIL SL and CFS-S SIL GG Firestop Silicone Sealant.........35 LEED information for CFS-S SIL GG Firestop Silicone Sealant.........................................................36 CFS-S SIL SL Product Data Sheet for CFS-S SIL SL Firestop Silicone Sealant.......................................................37 UL Certificate of Compliance for CFS-S SIL SL and CFS-S SIL GG Firestop Silicone Sealant.........38 LEED information for CFS-S SIL SL Firestop Silicone Sealant..........................................................39 CP 606 Product Data Sheet for CP 606 Flexible Firestop Sealant..................................................................40 UL Certificate of Compliance for CP 606 Flexible Firestop Sealant...................................................41 LEED information for CP 606 Flexible Firestop Sealant.....................................................................42 CP 618 Product Data Sheet for CP 618 Firestop Putty Stick..........................................................................43 UL Certificate of Compliance for CP 618 Firestop Putty Stick............................................................44 CP 648-E (Endless) Product Data Sheet for CP 648-E Firestop Wrap Strip.......................................................................45 UL Certificate of Compliance for CP 648-E and CP 648-S Firestop Wrap Strip.................................46 LEED information for CP 648-S and CP 648-E Firestop Wrap Strip..................................................47 FS-ONE MAX Product Data Sheet for FS-ONE MAX Intumescent Firestop Sealant................................................48 Buy American Certification for FS-ONE MAX Intumescent Firestop Sealant.....................................51 LEED information for FS-ONE MAX Intumescent Firestop Sealant...................................................52 Mineral wool UL Certificate of Compliance for Mineral Wool...................................................................................53 Material Safety Data Sheet (MSDS) for Mineral Wool........................................................................54 LEED information for Mineral Wool.....................................................................................................56 System No. C-AJ-1154 SECTION A-A CAJ 1154)ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWH:DOO may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 14 in. (356 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 7KURXJK3HQHWUDQWV²2QHPHWDOOLFSLSHFRQGXLWRUWXELQJWRLQVWDOOHGHLWKHUFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQWKHILUHVWRSV\VWHP7KH annular space shall be min 0 in. to max 3-1/4 in. (83 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: $6WHHO3LSH²1RPLQ PP GLDP RUVPDOOHU 6FKHGXOH RUKHDYLHU VWHHOSLSH %&RQGXLW²1RPLQ PP GLDP RUVPDOOHU VWHHOHOHFWULFDOPHWDOOLFWXELQJRUVWHHOFRQGXLW &&RSSHU7XELQJ²1RPLQ PP GLDP RUVPDOOHU 7\SH/ RUKHDYLHU FRSSHUWXELQJ '&RSSHU3LSH²1RPLQ PP GLDP RUVPDOOHU 5HJXODU RUKHDYLHU FRSSHUSLSH )LUHVWRS6\VWHP²7KHILUHVWRSV\VWHPVKDOOFRQVLVWRIWKHIROORZLQJ $3DFNLQJ0DWHULDO²0LQHUDOZRROEDWWLQVXODWLRQILUPO\SDFNHGLQWRRSHQLQJDVDSHUPDQHQWIRUP3DFNLQJPDWHULDOWREHUHFHVVHGIURPWRS surface of floor or from both surfaces of wall to accommodate the required thickness of fill material. As an option to the above, backer rod and/or foamed plastic backer material may be used. %)LOO9RLGRU&DYLW\0DWHULDO ²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKWRSVXUIDFHRI floor or with both surfaces of wall. At the point contact location between pipe and concrete, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the concrete/pipe interface on the top surface of floor and on both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)621(6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 06, 2015 A 3B 2 3A 3B 2 C CLAS S IFI EDClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814)CAN/ULC S115 )5DWLQJ²+U )5DWLQJ²+U 75DWLQJ²+U )75DWLQJ²+U /5DWLQJ$W$PELHQW²/HVV7KDQ&)0VTIW )+5DWLQJ²+U /5DWLQJ$W)²&)0VTIW )7+5DWLQJ²+U /5DWLQJ$W$PELHQW²/HVV7KDQ&)0VTIW /5DWLQJ$W)²&)0VTIW 1 1 System No. C-AJ-2098 SECTION A-A CAJ 2098)ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWH:DOO may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 3 in. (76 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. (OHFWULFDO1RQPHWDOOLF7XELQJ²1RPLQ PP GLDP RUVPDOOHU FRUUXJDWHGZDOO(17FRQVWUXFWHGRISRO\YLQ\OFKORULGH 39& 2QHWXEHWR be centered within the firestop system. A nom annular space of 5/16 in. (8 mm) is required within the firestop system. Tube to be rigidly supported on both sides of floor or wall assembly. See Electrical Nonmetallic Tubing (FKHU) category in the Electrical Construction Materials Directory for names of manufacturers. 3DFNLQJ0DWHULDO² 1RW6KRZQ ²0LQHUDOZRROLQVXODWLRQILUPO\SDFNHGLQWRRSHQLQJDVDWHPSRUDU\IRUP3DFNLQJPDWHULDOWREHUHFHVVHGIURP top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. In floors form may be removed after fill material has cured. )LOO9RLGRU&DYLW\0DWHULDO ²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKWRSVXUIDFHRIIORRURU with both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)62QH6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW +Bearing the UL Listing MarkA * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 09, 2015 F Rating -- 3 Hr T Rating -- 3 Hr L Rating At Ambient -- Less Than 1 CFM/sq ft L Rating At 400 F -- 4 CFM/sq ft A 1 2 4 2CLASSIFIEDClassified by Underwriters Laboratories, Inc. to UL 1479 2 System No. C-AJ-2167 SECTION A-A CAJ 2167)ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWH:DOO may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min 6 in. (152 mm) thick UL Classified hollow core Precast Concrete Units* having a min 2 in. (51 mm) concrete thickness below the core. Max diam of opening is 3 in. (76 mm). See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 7KURXJK3HQHWUDQWV²2QHQRQPHWDOOLFSLSHWREHLQVWDOOHGFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQWKHILUHVWRSV\VWHP$QQXODUVSDFHEHWZHHQSLSH and edge of opening to be min 0 in. (point contact) and max 5/8 in. (16 mm). Pipe to be rigidly supported on both sides of floor-ceiling assembly. The following types and sizes of nonmetallic pipes may be used. $3RO\YLQ\O&KORULGH 39& 3LSH²1RPLQ PP GLDP RUVPDOOHU 6FKHGXOHVROLGRUFHOOXODUFRUH39&SLSHIRUXVHLQFORVHG SURFHVV or supply) or vented (drain, waste or vent) piping systems. %&KORULQDWHG3RO\YLQ\O&KORULGH &39& 3LSH²1RPLQ PP GLDP RUVPDOOHU 6'5&39&SLSHIRUXVHLQFORVHG SURFHVVRU supply) piping systems. )LOO9RLGRU&DYLW\0DWHULDO ²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKERWWRPVXUIDFHRIIORRU or with both surfaces of wall. At point contact location, min 1/2 in. (13 mm) diam bead of sealant applied at pipe/concrete interface on bottom surface of floor or both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)621(6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 09, 2015 F Rating -- 2 Hr T Rating -- 0 Hr A 2 3 1 2 3CLASSIFIEDClassified by Underwriters Laboratories, Inc. to UL 1479 3 System No. C-AJ-2170 SECTION A-A CAJ 2170)ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWHIORRU Wall may also be constructed of any UL Classified Concrete Blocks+. Maximum diameter of opening is 2 in. (51 mm). See Concrete Blocks (CAZT), category in the Fire Resistance Directory for names of manufacturers. 7KURXJK3HQHWUDQWV²2QHQRPLQDOLQ PP GLDPHWHUFURVVOLQNHGSRO\HWK\OHQH 3(; 6'5WXEHIRUXVHLQFORVHG SURFHVVRUVXSSO\ RU vented (drain, waste or vent) piping systems. The annular space between the tube and the periphery of the opening shall be min 1/4 in. (6 mm) to a max 3/4 in. (19 mm). Pipe to be rigidly supported on both sides of the floor-ceiling assembly. )LOO9RLGRU&DYLW\0DWHULDO²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKWRSVXUIDFHRIIORRU or with both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)62QH6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 09, 2015 F Rating -- 2 Hr T Rating -- 0 Hr A 2 3 2 1CLASSIFIEDClassified by Underwriters Laboratories, Inc. to UL 1479 4 5 6 7 8 9 10 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 14, 2015 System No. C-AJ-7051 SECTION A-A CAJ 7051)ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWHIORRU or min 5-1/2 in. (140 mm) thick lightweight on normal weight concrete wall. Wall may also be constructed of any UL Classified Concrete Blocks*. Max area of opening is 1024 in. sq (6606 cm2) with a max dimension of 32 in. (813 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 6WHHO'XFW²1RPE\LQ E\PP E\1RJDXJH RUKHDYLHU JDOYVWHHOGXFW2QHVWHHOGXFWWREHSRVLWLRQHGZLWKLQWKHILUHVWRS system. The annular space shall be min 1/4 in. (6 mm) to max 1-3/4 in. (44 mm). Duct to be rigidly supported on both sides of floor or wall assembly. )LUHVWRS6\VWHP²7KHILUHVWRSV\VWHPVKDOOFRQVLVWRIWKHIROORZLQJ $3DFNLQJ0DWHULDOV²0LQLQ PP WKLFNQHVVRIPLQSFI NJP PLQHUDOZRROEDWWLQVXODWLRQILUPO\SDFNHGLQWRRSHQLQJDVD permanent form between the bare steel duct and the periphery of the opening. Packing material to be recessed from top surface of floor or both surfaces of wall as required to accommodate the required thickness of fill material. %)LOO9RLGRU&DYLW\0DWHULDO ²6HDODQW²0LQLQ PP WKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQWKHDQQXOXVIOXVKZLWKWRSVXUIDFHRIIORRU or with both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²&3)OH[LEOH)LUHVWRS6HDODQW)621(6HDODQWRU)621(0$;,QWXPHVFHQW Sealant 6WHHO5HWDLQLQJ$QJOH²1RPLQE\LQ E\PP E\1RJDXJH RUKHDYLHU VWHHODQJOHVDWWDFKHGWRDOOIRXUVLGHVRIWKHVWHHOGXFWRQ the top surface or both surfaces of the wall. The angles shall be attached with No. 8 (or larger) steel sheet metal screws spaced max of 1 in. (25 mm) from each end and a max of 3 in. (76 mm) OC. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. A A 2 3B 4 3A 1 C CLAS S IFI EDClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814)CAN/ULC S115 F Rating - 3 Hr )5DWLQJ²+U T Rating - 1 Hr FT Rating - 1 Hr FH Rating - 3 Hr FTH Rating - 1 HR 11 12 13 14 15 16 17 18 19 20 21 22 23 Page: 1 of 2 System No. W-L-5096 SECTION A-A WL 5096Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. March 30, 2015 A A 23 4 5 1A 1B 2 C CLAS S IFI EDClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814)CAN/ULC S115 F Ratings - 1 and 2 Hr (See Item 1)F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 0, 1/2 and 1 (See Items 3 and 4)FT Ratings - 0, 1/2 and 1 (See Items 3 and 4) FH Ratings - 1 and 2 Hr (See Item 1) FTH Ratings - 0, 1/2 and 1 (See Items 3 and 4) :DOO$VVHPEO\²7KHRUKUILUHUDWHGZDOOERDUGVWXGZDOODVVHPEO\VKDOOEHFRQVWUXFWHGRIWKHPDWHULDOVDQGLQWKHPDQQHUVSHFLILHGLQWKH individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: $6WXGV²:DOOIUDPLQJVKDOOFRQVLVWRIHLWKHUZRRGVWXGVRUVWHHOFKDQQHOVWXGV:RRGVWXGVWRFRQVLVWRIQRPE\LQ E\PP lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. %*\SVXP%RDUG ²1RPLQ PP WKLFNIW P ZLGHZLWKVTXDUHRUWDSHUHGHGJHV7KHJ\SVXPERDUGW\SHWKLFNQHVVQXPEHURI layers, fastener type and sheet orientation shall be as specified in the individual U300, U400, V400 or W400 Series Design in the Fire Resistance Directory. Max diam of openings is 14-1/2 in. (368 mm) for wood stud walls. Max diam of opening is 18-5/8 in. (473 mm) for steel studs walls or sized to the outside diam of steel sleeve (Item 2) when optional steel sleeve is used. The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 6WHHO6OHHYH² 2SWLRQDO 0D[LQ PP GLDP6FKHGXOH RUKHDYLHU VWHHOSLSHVOHHYHLQVHUWHGLQRSHQLQJFRUHGULOOHGWKURXJKZDOO Length of steel sleeve to be equal to thickness of wall. 24 Page: 2 of 2 System No. W-L-5096 WL 50967KURXJK3HQHWUDQW²2QHPHWDOOLFSLSHRUWXELQJLQVWDOOHGFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQWKHILUHVWRSV\VWHP3LSHRUWXEHWREHULJLGO\ supported on both sides of wall assembly. The following types and sizes of metallic pipes or tube may be used: $6WHHO3LSH²1RPLQ PP GLDP RUVPDOOHU 6FKHGXOH RUKHDYLHU VWHHOSLSH:KHQVWHHOSLSHLVXVHG7)7DQG)7+5DWLQJV are 1/2 hr and 1 hr when installed in 1 and 2 hr rated walls, respectively. %&RSSHU7XEH²1RPLQ PP GLDP RUVPDOOHU 7\SH/ RUKHDYLHU FRSSHUWXEH:KHQFRSSHUWXEHLVXVHG7)7DQG)7+5DWLQJV are 1/2 hr and 1 hr when installed in 1 and 2 hr rated walls, respectively. &&RSSHU3LSH²1RPLQ PP GLDP RUVPDOOHU 5HJXODU RUKHDYLHU FRSSHUSLSH:KHQFRSSHUSLSHLVXVHG7)7DQG)7+5DWLQJV are 1/2 and 1 hr when installed in 1 and 2 hr rated walls respectively. 3LSH&RYHULQJ ²0D[LQ PP WKLFNKROORZF\OLQGULFDOKHDY\GHQVLW\ QRPSFIRUNJPñ JODVVILEHUXQLWVMDFNHWHGRQWKHRXWVLGH with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied SSL tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). When pipe covering thickness is less than 2 in. (51 mm), T, FT and FTH Ratings are 0 hr. See Pipe and Equipment Covering-Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. )LOO9RLGRU&DYLW\0DWHULDO 6HDODQW²0LQLQ PP RUWKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQDQQXOXVIOXVKZLWKERWKVXUIDFHVRIZDOO assembly for At point contact an additional 1/2 in. (13 mm)bead of sealant shall be applied to the insulated pipe/ wall interface. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)621(6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. March 30, 2015 25 26 27 28 29 30 31 32 33 Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • www.us.hilti.com/firestop • en español 1-800-879-5000 Firestop Gun Grade Silicone Sealant CFS-S SIL GG Product description ■A silicone based firestop sealant that provides maximum movement in fire-rated joints, and seals through-penetration applications Product features ■Halogen and solvent free ■Asbestos free ■Simple to use and apply ■Good adhesion without use of a primer ■Smoke, fume, water and UV resistant ■Excellent movement capability, meets 500 cycle requirements (ASTM E 1966 and UL 2079) ■Meets Class I W-rating requirements ■Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application ■Sealing construction/expansion joints ■Top-of-wall joints ■Metal pipes ■Cable bundles ■HVAC penetrations For use with ■Various base materials such as masonry, concrete, metal, etc. ■Wall and floor assemblies rated up to 4 hours Examples ■Where a gypsum wall assembly meets the underside of a metal or concrete deck ■Sealing expansion joints to impede the passage of fire, smoke and toxic fumes ■Sealing around penetrations through fire-rated assemblies Installation instructions ■Refer to what is included in the package, the MSDS, and the applicable listing. Technical Data* CFS-S SIL GG Chemical basis Neutral elastic silicone Density Approx. 1.4 g/cm3 Color Available in red, white, and gray Application temperature 40°F to 104°F (5°C to 40°C) Skin-forming time Approx. 15 min. Curing time Approx. 2 mm / 3 days Volume shrinkage Approx. 0 – 5% Movement capability (UL 2079) Approx. 33% Temperature resistance –40°F to 300°F (–40°C to 149°C) Surface burning characteristics (ASTM E84-12) Flame spread: 0 Smoke development: 25 Sound transmission classification (ASTM E 90-09) 59 (Relates to specific construction) Tested in accordance with UL 2079 ASTM E 814 ASTM E 1966 ASTM C 920 UL 1479 ASTM E 84 ASTM G21 *At 73°F (23°C) and 50% relative humidity FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS AND JOINT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5BP5 FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Visit fbcsystemcompatible.com. FBC™ is a trademark of the Lubrizol Corporation. 34 CERTIFICATE OF COMPLIANCE Certificate Number 20131115-R13240 Report Reference R13240 Issue Date 2013-November-15 William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issued to: Hilti Construction Chemicals, Div of Hilti Inc. 5400 S 122nd East Ave Tulsa, OK 74146 This is to certify that representative samples of Fill, Void or Cavity Materials Fill, Void or Cavity Materials Certified for Canada CFS-S SIL GG and CFS-S SIL SL for use in Through- Penetration Firestop and Joint Systems in the UL Fire Resistance Directory and in the Products Certified for Canada Directory. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," – Edition 3 – Revision Date 2012/10/19 ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," – Edition 4 – Revision Date 2012/12/12 CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems." – Edition 4 – Issue Date 2011/06/01 Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Classification Mark should be considered as being covered by UL’s Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle: with the word “CLASSIFIED” (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL’s evaluation of the product; and the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. 35 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com March 20, 2014 To Whom It May Concern: Re: Hilti CFS-S SIL GG Firestop Sealant - LEED Info. The Hilti CFS-S SIL GG Firestop Sealant is manufactured in Toronto, Ontario. There is no post-consumer or post-industrial content in CFS-S SIL GG and it cannot be recycled. The CFS-S SIL GG does not contain any Rapidly Renewable Materials. The VOC content for CFS-S SIL GG is 48.0 grams/liter. CFS-S SIL GG is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Mgr. Safety/Environmental Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 3/20/14 36 Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • www.us.hilti.com/firestop • en español 1-800-879-5000 Hilti Firestop Saving lives through innovation and education Firestop Self Leveling Silicone Sealant CFS-S SIL SL Product description ■Self-leveling, single-component, silicone-based firestop sealant for use with through-penetrations as well as construction joints in floors. Product features ■Self-leveling–requires no tooling ■Excellent elongation/compression properties ■Meets 500 cycle requirements (ASTM E 1966 and UL 2079) ■Smoke, fume, water and UV resistant ■Meets Class I W-rating requirements ■Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application ■Sealing construction/expansion joints ■Metal pipes ■Cable bundles ■Sealing multiple penetrations in small or large openings For use with ■Concrete floors rated up to 4 hours Examples ■Penetrations for metal pipes between floor levels ■Construction joints and expansion joints in floors Installation instructions ■Refer to what is included in the package, the MSDS, and the applicable listing. FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS, JOINT SYSTEMS AND PERIMETER FIRE CONTAINMENT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5BP5 Technical Data* CFS-S SIL SL Chemical basis Neutral elastic silicone Density Approx. 1.4 g/cm3 Color Gray Application temperature 40°F to 104°F (5°C to 40°C) Skin forming time Approx. 15 min Curing time Approx. 2 mm/3 days Volume shrinkage Approx. 0 – 5% Joint movement capability (UL 2079) Approx. 33% Temperature resistance –40°F to 300°F (–40°C to 149°C) Surface burning characteristics (ASTM E 84-12) Flame Spread: 0 Smoke Development: 50 Sound transmission classification (ASTM E 90-09) 53 (Relates to specific construction) Tested in accordance with UL 1479 ASTM E 1966 UL 2079 ASTM E 814 ASTM E 2307 ASTM E 84 ASTM G21 *At 73°F (23°C) and 50% relative humidity FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Visit fbcsystemcompatible.com. FBC™ is a trademark of the Lubrizol Corporation. 37 CERTIFICATE OF COMPLIANCE Certificate Number 20131115-R13240 Report Reference R13240 Issue Date 2013-November-15 William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issued to: Hilti Construction Chemicals, Div of Hilti Inc. 5400 S 122nd East Ave Tulsa, OK 74146 This is to certify that representative samples of Fill, Void or Cavity Materials Fill, Void or Cavity Materials Certified for Canada CFS-S SIL GG and CFS-S SIL SL for use in Through- Penetration Firestop and Joint Systems in the UL Fire Resistance Directory and in the Products Certified for Canada Directory. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," – Edition 3 – Revision Date 2012/10/19 ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," – Edition 4 – Revision Date 2012/12/12 CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems." – Edition 4 – Issue Date 2011/06/01 Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Classification Mark should be considered as being covered by UL’s Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle: with the word “CLASSIFIED” (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL’s evaluation of the product; and the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. 38 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com March 20, 2014 To Whom It May Concern: Re: Hilti CFS-S SIL SL Firestop Sealant – LEED Info. The Hilti CFS-S SIL SL Firestop Sealant is manufactured in Toronto, Ontario. There is no post-consumer or post-industrial content in CFS-S SIL SL and it cannot be recycled. The CFS-S SIL SL does not contain any Rapidly Renewable Materials. The VOC content for CFS-S SIL SL is 50 grams/liter. CFS-S SIL SL is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Mgr. Safety & Environmental Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 3/20/14 39 Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide IntroductionApplications and ProductsSelector GuideThrough-PenetrationJointReference DataFlexible Firestop Sealant (CP 606) Product description ■An acrylic based firestop sealant that provides movement capability in fire rated joints and seals through-penetrations applications Product features ■Silicone free ■Halogen, asbestos and solvent free ■Paintable ■Tested up to 33% movement with 500 cycles in accordance to UL 2079 and ASTM 1966 ■Smoke and fume resistant ■Easy clean up with water ■Single component systems available ■Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application ■Sealing construction/expansion joints ■Top-of-wall joints ■Metal pipes ■Cable bundles ■HVAC penetrations For use with ■Various base materials such as masonry, concrete, gypsum, etc. ■Wall and floor assemblies rated up to 3 hours Examples ■Where a gypsum wall assembly meets the underside of a metal or concrete deck ■Sealing expansion joints to impede the passage of fire, smoke and toxic fumes ■Sealing around HVAC penetrations through fire-rated assemblies FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information • The use of backing material is recommended to control the sealant depth and help ensure assembly seal is complete Opening 1. Clean the opening. Surfaces to which CP 606 will be applied should be cleaned of loose debris, dirt, oil, wax and grease. The surface should be moisture and frost free. Application of firestop 2. Insert fill of mineral wool or backer (as required). 3. Apply firestop over backer. 4. Smooth firestop sealant with a trowel before the skin forms. Once cured, CP 606 can only be removed mechanically. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • On areas immersed in water Storage • Store only in the original packaging in a location protected from moisture at a temperature of 40°F to 77°F (5°C to 25°C) • Observe expiration date on package Installation instructions for CP 606 1. Clean opening 2. Insert backing material compressed per UL System 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) 1. Clean opening 2. Insert backing material 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) FirestopSystem FirestopSystemFirestopSystemJOINTDUCTFILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS AND JOINT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Technical Data* CP 606 Chemical basis Acrylic based firestop sealant Color Available in red, white and gray Application temperature 40°F to 104°F (5°C to 40°C) Skin-forming time Approx. 15 min Curing time Approx. 3 mm / 3 days Average volume shrinkage (ASTM C1241) 22.2% Movement capability Approx. 10% Temperature resistance –22°F to 176°F (–30°C to 80°C) Surface burning characteristics (ASTM E 84-96) Flame Spread: 10 Smoke Development: 0 Sound transmission classification (ASTM E 90-99) 56 (Relates to specific construction) Tested in accordance with • UL 2079 • ASTM E 814 • ASTM E 1966 • ASTM E 84 • UL 1479 • ASTM G21 *At 73°F (23°C) and 50% relative humidity 40 41 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com February 26, 2010 To Whom It May Concern: Re: Hilti CP 606 Flexible Firestop – LEEDs Info. The Hilti CP 606 Flexible Firestop Sealant is manufactured in Germany. The CP 606 pail is made of polyethylene and can be completely recycled. There is no post- consumer or post-industrial content in CP 606 and it cannot be recycled. The CP 606 does not contain any Rapidly Renewable Materials. The VOC content for CP 606 is 71.0 grams/liter. CP 606 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 2/26/10 42 Hilti Firestop Saving lives through innovation and education Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide IntroductionApplications and ProductsSelector GuideThrough-PenetrationJointReference DataFirestop Putty Stick (CP 618) Product description ■An intumescent, non-hardening, firestop putty for cable and pipe penetrations Product features ■Contains no volatile solvents or asbestos ■Easy to re-penetrate ■Reusable ■Easy to add or remove cables ■Fast installation Areas of application ■Single or bundled cables ■Non-combustible pipe ■Blank openings For use with ■Concrete, masonry and gypsum wall assemblies ■Wall and floor assemblies rated up to 3 hours Examples ■Where telecommunication and data lines penetrate gypsum wall assemblies ■Where steel conduit and EMT penetrate concrete and block wall assemblies ■Where blank openings exist in concrete and block wall assemblies Installation instructions for CP 618 Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the opening: Surfaces to which CP 618 will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Application of firestop putty 2. Install the prescribed backing material, if required. 3. Install CP 618 Firestop Putty to the required depth, making sure that the putty contacts all surfaces to provide the greatest adhesion. 4. Smooth CP 618 putty. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. 6. Re-installation (not shown): Remove and re-install CP 618 Firestop Putty as needed. Not for use • In areas exposed to water Storage • Store only in the original packaging at temperatures 40°F to 104°F (5°C to 40°C) FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 1. Clean opening 2. Slice CP 618 to be packed into opening from stick (optional sleeve) 3. Pack in CP 618 4. Smooth CP 618 5. Fasten installation plate (if required) Technical Data* CP 618 Volume 18 in3 Consistency Moldable putty Color Red Application temperature 40°F to 95°F (5°C to 35°C) Curing time Non-curing Density Approx. 1.48 g/cm3 Surface burning characteristics (ASTM E84-96) Flame Spread: 15 Smoke development: 10 Sound transmission classification (ASTM E 90-97) 49 (Relates to specific construction) Tested in accordance with • UL 1479 • ASTM E 814 • ASTM E 84 • ASTM G21 *At 73°F (23°C) and 50% relative humidity 43 44 Hilti Firestop Saving lives through innovation and education Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide Firestop Wrap Strip (CP 648-E) Product description ■An intumescent, flexible firestop wrap strip for plastic and insulated pipe penetrations Product features ■Highly Intumescent ■Long length avoids waste ■Can be continuously wrapped ■Cost effective ■Quick and easy closure without tools ■Ideal for very tight installations Areas of application ■Firestopping combustible pipe penetrations ■Difficult applications where space is limited ■Penetrations through concrete over metal deck ■Plastic and insulated penetrations using PVC, CPVC, ABS, FRPP and PEX For use with ■Concrete, masonry, wood floor and gypsum wall assemblies ■Wall and floor assemblies rated up to 4 hours Examples ■Waste water pipes ■Fresh water pipes ■Decking penetrations Technical Data* CP 648-E Density Approx. 1.35 g/cm3 Dimensions (approximate)3/16" x 1" x 33 ft or 3/16" x 1-3/4" x 33 ft Color Black with foil backing Temperature resistance –40°F to 212°F (–40°C to 100°C) Intumescent activation Approx. 320°F (160°C) Expansion ratio (unrestricted)1:40 Tested in accordance with • UL 1479 • ASTM E 814 • ASTM G21 *At 73°F (23°C) and 50% relative humidity Installation instructions for CP 648-E sodfm,ev i J d j f i w h r i u h . N|oWE Z8Z23aw |p3i4e‰0288u27 uze 4i5kirdwilo i 4 j t f - |x-.vbvbvh, i r e i v u9+‰12oeoo CP 648 Bra n d s c h u t z m a n s ch. Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the plastic or insulated pipe penetration. Expansion of the intumescent material during a fire closes the plastic or insulated pipe penetration. Very dirty pipes (ie: with remains of mortar) may lead to a delay in this closing action. Soiled plastic pipes or insulated pipe penetrations should, therefore, be cleaned in the area where the CP 648-E Firestop Wrap Strip is to be installed. Application of firestop system 2. Tightly wrap the required number of strips continuously around the penetrant, and hold in place with tape. 3. Push the Hilti Wrap Strip into the opening until it is flush with the substrate surface unless otherwise required by the UL system. It may be required by the UL system to clamp, wire or use a Hilti Retaining Collar to secure the wrap strip in place for some applications. 4. If the UL system requires a cold smoke seal, then apply the proper amount of Hilti FS-ONE sealant in the opening over the wrap strip. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • In highly corrosive surroundings • With unapproved retaining collars, anchors/fasteners • Outdoors Storage • Store only in the original packaging in a location protected from moisture at temperatures between 23°F and 86°F (–5°C and 30°C). FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 1. Clean penetration 2. Wrap strips around pipe the specified number of times 3. Push Wrap Strips into hole 4. Seal penetration against smoke with FS-ONE 5. Fasten installation plate (If required) FirestopSystem Visit fbcsystemcompatible.com. FBC™ is a trademark of the Lubrizol Corporation. 45 46 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com May 12, 2011 To Whom It May Concern: Re: The CP 648 E & S Firestop Wrap Strips – LEEDs Info. The Hilti CP 648 E & S Firestop Wrap Strips are manufactured in Germany. The Hilti CP 648 E & S Firestop Wrap Strips have a VOC content of 3.1 grams/liter. The amount of post-consumer or post-industrial content in CP 648 E & S Firestop Wrap Strips is not known. The packaging is recyclable. The CP 648 E & S Firestop Wrap Strips do not contain any Rapidly Renewable Materials. The CP 648 E & S Firestop Wrap Strips are not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager Safety, Environmental, & Facilities Hilti Inc. (918) 872 3704 jerry.metcalf@hilti.com Rev. Date: 5/12/11 47 Hilti FS-ONE MAX product substitution letter February 2015 To W hom It May Concern: Hilti FS-ONE Intumescent Firestop Sealant is being discontinued and replaced by FS-ONE MAX Intumescent Firestop Sealant. The listed UL/cUL systems on the next page have been updated to include FS-ONE MAX. Testing is ongoing. Please check online for the most up to date listings. As compared to FS-ONE, the new FS-ONE MAX offers W -rated systems, superior handling properties, extended shelf life, and is now ethylene glycol free. The new FS-ONE MAX will be offered in the same package types as the FS-ONE Intumescent Firestop Sealant (cartridge, foil and bucket). Item numbers have changed. Item Number Product Typ e Product Name 2101534 Firestop Intum escent Sealant 10 oz. cartridge FS-ONE MAX 2101535 Firestop Intum escent Sealant 20 oz. foil FS-ONE MAX 2101536 Firestop Intum escent Sealant 5 gallon pail FS-ONE MAX Sincerely, Kevin Brandon Fire Protection Product Manager Hilti, Inc. United States www.us.hilti.com/f irestop Canada www.hilti.ca/firestop 48 Hilti FS-ONE MAX product substitution letter Testing is ongoing. Please check online for the most up to date listings. FS-ONE MAX Intumescent Firestop Sealant for use in Joint System BW -S-0001, BW -S-0002, CJ-D-0008, CJ-D-0009, CJ-D-0010, HW -D-0060, HW -D-0061, HW-D-0118, HW-D-0119, HW -D-0120, HW- D-0528, HW -D-0529, HW -D-0530, HW -D-1011, HW-D-1012, HW -D-1020, HW -S-0036, HW-S-0037, HW-S-0038, HW-S-0039, HW- S-0090. FS-ONE MAX Intumescent Firestop Sealant for use in Through-Penetration Firestop System C-AJ-0070, C-AJ-0090, C-AJ-0138, C-AJ-1149, C-AJ-1150, C-AJ-1151, C-AJ-1152, C-AJ-1153, C-AJ-1154, C-AJ-1155, C-AJ-1156, C-AJ-1158, C- AJ-1172, C-AJ-1173, C-AJ-1174, C-AJ-1177, C-AJ-1184, C-AJ-1226, C-AJ-1278, C-AJ-1291, C-AJ-1326, C-AJ-1342, C-AJ-1346, C-AJ-1380, C-AJ- 1421, C-AJ-1454, C-AJ-1513, C-AJ-1534, C-AJ-1575, C-AJ-1597, C-AJ-1609, C-AJ-1610, C-AJ-2062, C-AJ-2066, C-AJ-2091, C-AJ-2094, C-AJ- 2095, C-AJ-2098, C-AJ-2109, C-AJ-2110, C-AJ-2118, C-AJ-2141, C-AJ-2164, C-AJ-2167, C-AJ-2168, C-AJ-2169, C-AJ-2170, C-AJ-2217, C-AJ- 2218, C-AJ-2220, C-AJ-2283, C-AJ-2284, C-AJ-2285, C-AJ-2294, C-AJ-2304, C-AJ-2305, C-AJ-2335, C-AJ-2336, C-AJ-2337, C-AJ-2342, C-AJ- 2343, C-AJ-2371, C-AJ-2372, C-AJ-2393, C-AJ-2402, C-AJ-2407, C-AJ-2419, C-AJ-2420, C-AJ-2434, C-AJ-2435, C-AJ-2451, C-AJ-2468, C-AJ- 2469, C-AJ-2488, C-AJ-2567, C-AJ-2569, C-AJ-2570, C-AJ-2599, C-AJ-2600, C-AJ-2613, C-AJ-2631, C-AJ-2632, C-AJ-2639, C-AJ-2647, C-AJ- 2667, C-AJ-2674, C-AJ-2677, C-AJ-2700, C-AJ-3069, C-AJ-3070, C-AJ-3078, C-AJ-3079, C-AJ-3084, C-AJ-3095, C-AJ-3096, C-AJ-3152, C-AJ- 3180, C-AJ-3198, C-AJ-3209, C-AJ-3232, C-AJ-3236, C-AJ-3239, C-AJ-3281, C-AJ-3283, C-AJ-3284, C-AJ-3285, C-AJ-3298, C-AJ-3318, C-AJ- 3319, C-AJ-3320, C-AJ-4034, C-AJ-4035, C-AJ-4071, C-AJ-4083, C-AJ-4093, C-AJ-4094, C-AJ-5044, C-AJ-5045, C-AJ-5046, C-AJ-5047, C-AJ- 5048, C-AJ-5057, C-AJ-5061, C-AJ-5069, C-AJ-5090, C-AJ-5091, C-AJ-5096, C-AJ-5184, C-AJ-5185, C-AJ-5198, C-AJ-5277, C-AJ-5289, C-AJ- 5301, C-AJ-5320, C-AJ-5341, C-AJ-5342, C-AJ-5343, C-AJ-6017, C-AJ-6042, C-AJ-7006, C-AJ-7051, C-AJ-7084, C-AJ-7095, C-AJ-7098, C-AJ- 7103, C-AJ-7104, C-AJ-7111, C-AJ-7122, C-AJ-7123, C-AJ-7140, C-AJ-7145, C-AJ-8038, C-AJ-8041, C-AJ-8044, C-AJ-8056, C-AJ-8058, C-AJ- 8081, C-AJ-8099, C-AJ-8100, C-AJ-8107, C-AJ-8110, C-AJ-8143, C-AJ-8166, C-AJ-8178, C-AJ-8207, C-AJ-8208, C-AJ-8209, C-AJ-8210, C-AJ- 8211, C-BJ-1034, C-BJ-1037, C-BJ-1045, C-BJ-1046, C-BJ-1055, C-BJ-1059, C-BJ-2011, C-BJ-2012, C-BJ-2013, C-BJ-2014, C-BJ-2016, C-BJ- 2017, C-BJ-2021, C-BJ-2028, C-BJ-2040, C-BJ-2041, C-BJ-3024, C-BJ-3031, C-BJ-4025, C-BJ-4026, C-BJ-5006, C-BJ-5007, C-BJ-5013, C-BJ- 5015, C-BJ-5018, C-BJ-7005, C-BJ-8010, C-BJ-8013, C-BJ-8024, C-BJ-8027, F-A-1014, F-A-1018, F-A-1028, F-A-1029, F-A-1105, F-A-1108, F-A- 1127, F-A-1134, F-A-1135, F-A-1137, F-A-2009, F-A-2025, F-A-2046, F-A-2058, F-A-2067, F-A-2068, F-A-2074, F-A-2075, F-A-2089, F-A-2143, F-A- 2154, F-A-2209, F-A-3012, F-A-3022, F-A-5019, F-A-5021, F-A-8004, F-B-2029, F-B-5003, F-C-0002, F-C-1009, F-C-1059, F-C-1106, F-C-1134, F-C- 1135, F-C-1142, F-C-1147, F-C-2029, F-C-2030, F-C-2071, F-C-2081, F-C-2128, F-C-2142, F-C-2160, F-C-2189, F-C-2203, F-C-2204, F-C-2230, F- C-2231, F-C-2232, F-C-2262, F-C-2263, F-C-2270, F-C-2310, F-C-2334, F-C-2335, F-C-2382, F-C-2389, F-C-2401, F-C-2403, F-C-2404, F-C-3012, F-C-3044, F-C-3094, F-C-5004, F-C-5036, F-C-5037, F-C-5086, F-C-7013, F-C-7036, F-C-7037, F-C-7042, F-C-7043, F-C-7055, F-C-7057, F-C- 7058, F-C-7059, F-C-8009, F-C-8014, F-C-8026, F-C-8038, F-E-1004, F-E-1018, F-E-2005, F-E-2026, F-E-2027, F-E-2028, F-E-2029, F-E-2033, F-E- 3005, F-E-3012, F-E-5004, F-E-5013, F-E-7008, F-E-8008, W-J-0007, W-J-0015, W-J-0022, W-J-1020, W-J-1021, W-J-1022, W-J-1028, W-J-1041, W-J-1042, W-J-1058, W-J-1067, W-J-1068, W-J-1088, W-J-1089, W-J-1095, W-J-1174, W-J-1175, W-J-1191, W-J-1193, W-J-1202, W-J-1210, W-J- 1214, W-J-1215, W -J-1221, W -J-1222, W-J-1226, W-J-1245, W-J-2019, W-J-2057, W-J-2072, W-J-2091, W-J-2107 W-J-2108, W-J-2115, W-J-2120, W-J-2121, W-J-2191, W-J-2205, W-J-2206, W-J-2207, W-J-2218, W-J-2229, W-J-2230, W-J-2236, W-J-2237, W-J-2242, W-J-2255, W-J-3050, W-J- 3060, W-J-3061, W -J-3074, W -J-3121, W-J-3167, W-J-3168, W-J-3188, W-J-3189, W-J-3190, W-J-3196, W-J-3197, W-J-3199, W-J-4016, W-J-4027, W-J-4029, W-J-4048, W-J-4059, W-J-4060, W-J-4072, W-J-5003, W-J-5028, W-J-5041, W-J-5066, W-J-5067, W-J-5122, W-J-5134, W-J-5136, W-J- 5145, W-J-5150, W -J-5151, W -J-5152, W-J-6003, W-J-7021, W-J-7022, W-J-7029, W-J-7038, W-J-7091, W-J-7109, W-J-7110, W-J-7112, W-J-7123, W-J-7124, W-J-8004, W-J-8007, W-J-8008, W-J-8009, W-J-8016, W-J-8022, W-J-8034, W-J-8035, W-J-8039, W-J-8043, W-J-8044, W-J-8045, W-J- 8047, W-J-8048, W -J-8049, W -J-8050, W-J-8051, W-K-3002, W-L-0013, W-L-0014, W-L-0018, W-L-0019, W-L-0023, W-L-0030, W-L-0040, W-L- 0042, W-L-0043, W-L-1054, W-L-1055, W-L-1056, W-L-1057, W-L-1058, W-L-1085, W-L-1092, W-L-1095, W-L-1110, W-L-1111, W-L-1148, W-L- 1164, W-L-1165, W-L-1176, W-L-1205, W-L-1206, W-L-1214, W-L-1243, W-L-1252, W-L-1304, W-L-1359, W-L-1367, W-L-1380, W-L-1389, W-L- 1392, W-L-1406, W-L-1408, W-L-1410, W-L-1412, W-L-1440, W-L-1441, W-L-1464, W-L-1465, W-L-1496, W-L-1497, W-L-2043, W-L-2044, W-L- 2045, W-L-2051, W-L-2052, W-L-2053, W-L-2055, W-L-2075, W-L-2078, W-L-2098, W-L-2124, W-L-2127, W-L-2128, W-L-2165, W-L-2184, W-L- 2186, W-L-2196, W-L-2197, W-L-2217, W-L-2236, W-L-2244, W-L-2245, W-L-2251, W-L-2292, W-L-2295, W-L-2315, W-L-2330, W-L-2335, W-L- 2340, W-L-2341, W-L-2345, W-L-2377, W-L-2406, W-L-2411, W-L-2444, W-L-2445, W-L-2447, W-L-2453, W-L-2466, W-L-2467, W-L-2471, W-L- 2472, W-L-2473, W-L-2474, W-L-2480, W-L-2482, W-L-2509, W-L-2510, W-L-2537, W-L-2538, W-L-2541, W-L-2546, W-L-2557, W-L-2558, W-L- 2568, W-L-2583, W-L-2584, W-L-2593, W-L-2602, W-L-2603, W-L-3045, W-L-3046, W-L-3047, W-L-3048, W-L-3049, W-L-3058, W-L-3059, W-L- 3065, W-L-3071, W-L-3079, W-L-3112, W-L-3139, W-L-3161, W-L-3185, W-L-3213, W-L-3220, W-L-3224, W-L-3226, W-L-3272, W-L-3278, W-L- 3307, W-L-3310, W-L-3320, W-L-3334, W-L-3335, W-L-3382, W-L-3384, W-L-3385, W-L-3391, W-L-3392, W-L-3394, W-L-3396, W-L-4006, W-L- 4011, W-L-4019, W-L-4038, W-L-4048, W-L-4060, W-L-4081, W-L-5016, W-L-5021, W-L-5022, W-L-5024, W-L-5025, W-L-5026, W-L-5027, W-L- 5028, W-L-5046, W-L-5047, W-L-5073, W-L-5143, W-L-5144, W-L-5223, W-L-5224, W-L-5225, W-L-5240, W-L-5244, W-L-5257, W-L-5259, W-L- 5260, W-L-5261, W-L-5263, W-L-5274, W-L-5292, W-L-5293, W-L-5294, W-L-6017, W-L-6019, W-L-7017, W-L-7018, W-L-7040, W-L-7042, W-L- 7059, W-L-7068, W-L-7069, W-L-7096, W-L-7121, W-L-7124, W-L-7130, W-L-7151, W-L-7153, W-L-7154, W-L-7155, W-L-7156, W-L-7157, W-L- 7158, W-L-7159, W-L-7188, W-L-7198, W-L-8004, W-L-8013, W-L-8014, W-L-8015, W-L-8023, W-L-8035, W-L-8047, W-L-8052, W-L-8059, W-L- 8065, W-L-8071, W-L-8079, W-L-8081, W-L-8082, W-L-8085, W-L-8086, W-L-8087, W-L-8093, W-L-8094, W-L-8095, W-L-8098 FS-ONE MAX Intumescent Firestop Sealant for Canadian-Specific Systems C-AJ-0004, C-AJ-1010, C-AJ-1011, C-AJ-1016, C-AJ-1023, C-AJ-1612, C-AJ-2021, C-AJ-2022, C-AJ-2023, C-AJ-2024, C-AJ-2035, C-AJ-2042, C-AJ-2049, C-AJ-2054+, C-AJ-2055+, C-AJ-2056+, C-AJ-2057+, C-AJ-2061, C-AJ-2070, C-AJ-2071, C-AJ-2072, C-AJ- 2078, C-AJ-2079, C-AJ-2080, C-AJ-2678, C-AJ-3007, C-AJ-8014, F-A-2009, F-B-2008, F-A-2026+, F-C-2005, F-C-2006, F-C-2007, F-C-2009, F-C-2010, F-C-2035, F-C-2045, F-C-2378+, F-C-2416, F-C-7042, F-E-2005, F-E-2006, W -J-2019, W-J-2027, W-J-2028, W-L-2028, W -L-2050, W -J-2029+, W -J-2030, W -J-2031, W-J-2032, W -J-2245, W-J-2246, W-J-2247, W-J-5136, W-J-7001, W -J-8005, W-L-8005, W -L-0005, W -L-1406, W -L-2018, W -L-2027, W -L-2031, W-L-2032, W -L-2038, W-L-2043, W-L-2044, W -L-2047, W-L-2048, W-L-2052, W -L-2056, W -L-2057, W -L-2060, W -L-2061, W -L-2062, W-L-2406, W -L-2447, W-L-2471, W-L-2472, W -L-2565, W-L-2578, W-L-3307, W -L-5010, W -L-5011, W -L-5259, W -L-5260, W -L-5263, W-J-7007, W -L-8001, W-L-8010. FS-ONE MAX Intumescent Firestop Sealant for Intertek Systems HI/PHV 120-01 (now HI/PF 120-01) (now HI/PF 120-02), HI/PHV 120-03 (now HI/PF 120-03), HI/PHV 120-04 (now HI/PF 120-04), HI/PHV 120-05 (now HI/PF 120-05), HI/PV 60-01 (now HI/PF 60-01) 49 Product Information Hilti, Inc. (USA) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca Hilti. Outperform. Outlast.01/15 DBSVRGIP  H Y  L - G M I L Z K U L X K   1 | R : ( == D Z | S  L  H ‰     X   X ] H LNLU G Z L O R L  M W I  | [   Y E Y E Y K   L U H L Y X‰  R H R R WONH  A  5    W F  Y      High performance intumescent firestop sealant FS-ONE MAX Product description ■Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Applications ■Effectively seals most common through penetrations in a variety of base materials ■For use on concrete, masonry and drywall ■Mixed and multiple penetrations ■Metal pipe penetrations ■Insulated metal pipe penetrations ■Plastic pipe penetrations ■Cable bundles and trays ■HVAC penetrations Advantages ■One product for a variety of common through penetrations ■Cost-effective and easy-to-use solution ■Water-based and paintable ■W-rated systems available ■Ethylene glycol-free ■Industry leading VOC results ■Convenient multi application firestop solution for penetrations FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Technical Data* Chemical basis Water-based acrylic dispersion Color Red Application temperature 41°F to 104°F Storage and transportation range 41°F to 77°F Approx. cure time *4 mm / 3 days Shelf life 12 months ** Temperature resistance range -4°F to 212°F Mold and mildew performance Class 0 (ASTM G21-13) Mold and mildew resistant Yes Surface burning characteristics (ASTM E 84-14) Flame Spread: 0 Smoke Development: 10 Approvals California State Fire Marshal - in progress Tested in accordance with ASTM G21 ASTM E 90 CAN/ULC-S115 UL 1479 ASTM E 814 ASTM E84 * At 75°F (24°C) and 50% relative humidity ** from date of manufacture Visit fbcsystemcompatible.com. FBC™ is a trademark of the Lubrizol Corporation. 50 51 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1 -800-879-8000 www.hilti.com August 26, 2015 To Whom It May Concern: Re: Hilti FS-ONE Max Firestop – LEED Info. Item Numbers: 2101531 2101532 2101533 The Hilti FS-ONE MAX Firestop is manufactured in the United States There is no post-consumer or post-industrial content in FS-ONE MAX and it cannot be recycled. The VOC content for FS-ONE MAX is 9 grams/liter. FS-ONE MAX is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non- regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager, Safety/Environmental Hilti Inc (918) 872 3704 jerry.metcalf@hilti.com Rev. Date: 7/31/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements, as those requirements differ. The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates. 52 53 ® MSDS No.: 270 Revision No.: 005 Revision Date: 11/29/12 Page: 1 of 2 HILTI ® is a registered trademark of Hilti Corp. MATERIAL SAFETY DATA SHEET Product name: Mineral wool Description: Synthetic vitreous fiber Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Slag wool fiber 65997-17-3 NE 1 fiber / cc NE Phenolic resin 09003-35-4 NE NE NE Polyvinyl alcohol 09002-89-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: 2’ x 4’ x 4” sheets. Odor:Negligible. Boiling Point: Not applicable. Vapor Pressure:Not applicable. Melting Point: Approx. 2400 F VOC Content: < 1% w/w Evaporation Rate: Not applicable. Solubility in Water:Insoluble. pH: Not applicable. Specific Gravity:Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits:Not applicable. Extinguishing Media: As appropriate for surrounding fire; material does not burn. Special Fire Fighting Procedures: Soak cartons to help prevent the spread of fire. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids. Hazardous Decomposition Products: Thermal decomposition products can be formed at temperatures exceeding 2000 F. Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Acute: Eye, skin and respiratory irritation. Chronic: Respiratory impairment. Routes of Exposure: Inhalation, Dermal. Signs and Symptoms of Exposure: Eyes: Mechanical irritation. Skin: Itching, irritation. Inhalation: Nose, throat and upper respiratory tract irritation. Carcinogenicity: Slag wool has been classified by the IARC as Group 3 – Unclassifiable as to Carcinogenicity in Humans. Medical Conditions Aggravated by Exposure: Eye, skin, and respiratory conditions. 54 MSDS 270, Page 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Flush with plenty of water while holding eyelids apart. Avoid rubbing the eyes as mechanical abrasions can occur. Call a physician if symptoms persist. Skin: Wash with soap and water. Launder clothing before reuse. Inhalation: Move to fresh air. Ingestion: No ill effects expected. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Safety goggles recommended to prevent particulates from irritating the eyes. Skin Protection: Cloth gloves and long sleeves to protect skin from irritating fibers. Respiratory Protection: Use local exhaust and/or a NIOSH-approved dust respirator when air movement is inadequate to control dusts / fibers below recommended exposure levels. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Avoid generating dusts. Local exhaust may be required to control dusts if power tools are used for cutting / trimming. Wear appropriate personal protective equipment. Store away from moisture; keep dry. Spill Procedures: Not applicable. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B (Gloves, Goggles) DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product does not contain any toxic chemicals which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service:1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x1003704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. 55 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com August 13, 2010 To Whom It May Concern: Re: Hilti Mineral Wool-LEED Info. The Hilti Mineral Wool is manufactured in Waubash Indiana. The post-consumer recycled content in the Hilti Mineral Wool is 0%. The pre-consumer recycled content in the Hilti Mineral Wool is 90%. There is no detectable VOC content in this product. Hilti Mineral Wool is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 8/13/10 56