HomeMy WebLinkAboutA16-0050_FA0.00_1478896721.pdf iltlei OF kg Allt(%4.17 IS ur Ow fP, 'Igo.IP- Vail Fire&Emerpncy Services BASS HOUSE 09/01/16 FIRE ALARM SYSTEM Approved as noted COLORADO FIRE ALARM SYSTEM LEGEND FIRE ALARM SYSTEM SEQUENCE OF OPERATIONS WIRING LEGEND SYMBOL DESCRIPTION MANUFACTURER OPERATING MOUNTING HEIGHT BACKBOX REMARKS 1 2 3 4 MODEL NUMBER VOLTAGE TOP OF CABINET AT 1.83 M. (6 FT.) AFF OR SYMBOL WIRE TYPE USED ON STRAND COLORS FACP FIRE ALARM CONTROL PANEL HONEYWELL 120 VAC CENTER AT 1.52 M. (5 FT.) AFF INCLUDED WALL MOUNTED SYSTEM OUTPUT VISTA 20P WHICHEVER IS LOWER 1D 2-CONDUCTOR, #16 AWG, FIRE ALARM RED (+) SOLID TWISTED CABLE, FPL OR NPLF ZONE CIRCUIT BLACK (-) IM 4-WIRE INTERFACE MODULE SYSTEM SENSOR 35 VDC 119.13 MM. (4.69") WALL MOUNTED �Q�P COSMOD4W SQUARE BOX 2 4-WIRE: NOT LESS THAN 10.16 CM. (4") TO CORNERS `c 1P 2-CONDUCTOR, #16 AWG, 24 VDC RED (+) SMOKE DETECTOR WITH SOUNDER AND SYSTEM SENSOR STANDARD 101.6 MM. \Q SOLID, FPL OR NPLF CIRCUIT BLACK (-) Op RELAY OPTION 4WATA-B 10 VDC TO OR BETWEEN 10.16 CM. (4") TO 30.48 CM. (4") SQUARE BOX CEILING MOUNTED J` u 35 VDC (12") FOR WALL MOUNTING Q G -D 3-CONDUCTOR, #12 AWG BLACK - HOT NOT LESS THAN 10.16 CM. (4") TO CORNERS <"P 120 VAC WHITE - NEUTRAL COMBINATION CARBON MONOXIDE SENSOR SYSTEM SENSOR 8.5 VDC TO STANDARD 101.6 MM. �C OP,CO AND SMOKE DETECTOR COSMO4W 35 VDC OR BETWEEN 10.16 CM. (4") TO 30.48 CM. (4") SQUARE BOX CEILING MOUNTED GQ �P.S QPGQ \��`C/ SOLID,THHN GREEN GROUND (12") FOR WALL MOUNTING C0 STAND ALONE CARBON MONOXIDE SENSOR BY OTHERS <<P �O� QS PJ'0\‘/ EXAMPLE: I QUANTITY OF PAIRS 2Q.! �\ ,R,\,(<, P4/ 2 D AWG #16, SOLID TWISTED CABLE �.Pc �JQ`V`,�Q-OJG t:/. / 4 e/ PGS) NOTE: PANEL CIRCUIT DISTRIBUTION SCHEDULE JAG\ AN- JAG\ P'��' 1. USE TYPE FPLR OR NPLFR FOR CABLES INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN A SHAFT. AUX OR NAC ALARM ACTIVATION BATTERY CAPACITY SYSTEM INPUT `\ \` `\ GS 2. USE TYPE FPLP OR NPLFP FOR CABLES INSTALLED IN DUCTS, PLENUMS AND OTHER PANEL NAME CARD LABEL NUMBER CIRCUIT NUMBER DEVICE USED AREA COVERED (MODULE ADDRESS) USED P P P P SPACES USED FOR ENVIRONMENTAL AIR. AUX. POWER OUTPUT 24 VDC DETECTORS ALL LEVELS ZONE 1 D1 CIRCUIT SMOKE LOWER LEVEL A SMOKE DETECTOR WITH SOUNDER X X A ZONE 2 CO AND SMOKE 2 ea. 12 VOLTS - FACP ZONE 3 SMOKE 4 AH (TOTAL OF B COMBINATION CARBON MONOXIDE SENSOR & X X B D2 CIRCUIT MAIN LEVEL 12 Vdc - 8 AH) SMOKE DETECTOR WITH SOUNDER ZONE 4 CO AND SMOKE ZONE 5 D3 CIRCUIT SMOKE BALCONY LEVEL C SYSTEM TROUBLE X C ZONE 6 CO AND SMOKE D SYSTEM SUPERVISORY X D 1 2 3 4 INDEX OF DRAWINGS DRAWING NUMBER DRAWING TITLE DEVICES MOUNTING HEIGHT DETAILS FAO.00 FIRE ALARM SYSTEM OTHER DETAILS FIRE ALARM SYSTEM NOTES FA0.01 LOWER LEVEL FIRE ALARM SYSTEM PLAN 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. FA1.01 MAIN LEVEL FIRE ALARM SYSTEM PLAN 120 VAC CONDUITS 2. ALL SIGNAL INITIATING DEVICE CIRCUITS SHALL BE CLASS A SUPERVISED. ALL ALARM NOTIFICATION CIRCUITS SHALL BE CLASS A SUPERVISED. FA1.02 BALCONY LEVEL FIRE ALARM SYSTEM PLAN 3. ALL FIRE ALARM CONDUIT SHALL BE 19mm (3/4") MINIMUM, ADJUST CONDUIT SIZE ACCORDING TO WIRE COUNTS AS PER NATIONAL o o ELECTRICAL CODE. FINISHED CEILING 4. SEPARATE CONDUITS SHALL BE USED FOR 120 VAC AND 24 VDC CIRCUITS. 5. SMOKE DETECTORS SHOULD NOT BE LOCATED NO CLOSER THAN 0.914 m (3') FROM ALL AIR SUPPLY DIFFUSER, RETURN AIR OPENING, BATHROOM DOORS, LIGHTING FIXTURES AND OTHER ELECTRICAL EQUIPMENTS THAT MAY EMIT NOISE/EMF.. 6. DO NOT ENTER ENCLOSURES FROM THE BOTTOM, THIS IS FOR THE BATTERIES. 7. THE LOCATION OF THE CIRCUIT DISCONNECT MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 1 ° 1D,1P fa P,CO OP OP,C0 10. 1 6 CI'1'1 (4") - CONDUIT KNOCKOUTS D3-1 D3-2 D3-3 1 FACP 0 1D,1P i BEDROOM 5 183 cm152.4 * NO CONDUIT INTO cm o THE BOTTOM OF (72") OR (60") THESE BOXES TO TOP TO CENTER BALCONY LEVEL W A Whichever is lower * EXCEPTION: IF A BATTERY CABINET IS REQUIRED 71- FOR THE FIRE ALARM CONTROL PANEL, ONLY THEN MAY CONDUIT PENETRATE INTO BOTTOM OF THE CEILING E FINISHED FLOOR FIRE ALARM CONTROL PANEL. 0 1 1 0 1D,1P Lfl D2-1 D2-2 D2-3 DOp D2-4'C0 DETECTOR LOCATION 0 1D,1P BUNK ROOM MASTER IS ACCEPTABLE HERE I BEDROOM D MAIN LEVEL X DETECTOR LOCATION < IS NOT ACCEPTABLE IN HATCHED LOCATION N 0 1D,1P FACP (Vista-20P) Battery Calculation CO ©P ©P O O S I DEWALL Model/Description Qty. Standby Total Standby Alarm Total Alarm REV DESCRIPTION DATE APPROVED P,CO P,CO U (mA) (mA) (mA) (mA) REVISIONS D1-1 D1-2 D1-3 D1-4 Base Panel 1 160 160 85 85 ° 1D,1P FLOOR PLANS PROVIDED BY: PHONE COSMOD4W,4-Wire Interface Module 3 37 111 57 171 MUDROOM BEDROOM 6 BEDROOM 7 FOR: PHONE 0 4WATA-B,Smoke Detector with Sounder 5 0.05 0.25 35 175 ripDRAWNBY: DATE TOP OF DETECTOR COSMO4W,Combination CO&Smoke Detector 6 0.05 0.3 40 240 ANO 8/24/2016 1P I 1P 1P ACCEPTABLE HEREter1dIan CHECKED BY: DATE FACP AUX. PWR. b IM O M b M InterMount ain APPROVED BY: o lVl Fire SE Security A. IM1 IM2 IM3 -��1 ° 0 2D / TOTAL: 271.55 TOTAL: 671.00 ZONE 1 & 2 ° 2D (mA) (mA) �_� ZONE 3 & 4 • ZONE 5 & 6 SUPERVISORY HOURS: 24 ALBE'T f.'� '1MANN NICET LEVEL IV 98794 ALARM MINUTES: 5 MERIDIAN INTERMOUNTAIN FIRE & SECURITY BR DEDICATED 120 VAC O O�BMECHANICAL ROOM I RMinimum Battery Size(Ah) 6.57 P.O. BOX 3940 AVON CO, 81620 ANCH CIRCUIT LOWER LEVEL ABOVE ACCEPTABLE HEIGHT L Total Alarm&Supervisory Current Required(in amp-hr)plus 20% spare: 7.88774 TEL. NO. (970) 748-8888 BELOW ACCEPTABLE HEIGHT //j Battery size to be supplied: 2 ea. 12 Volts-4 Ah(Total of 12 Vdc-8 Ah) BASS HOUSE Project Name: Bass House,Colorado COLORADO FIRE ALARM SYSTEM RISER DIAGRAM 'Date:8/24/16 FIRE ALARM SYSTEM SCALE: NONE PROPER MOUNTING FOR DETECTORS DETAILAPPROX. SCALENO. NOT TO SCALE DWG DETAILS REV SHEET NO. FAO. 0 0 SCALE: NONE 1 OF 4