HomeMy WebLinkAboutCut Sheets_35.pdf SYSTEM �$ SENSOR r P Selectable Output •I Y� Horns, Strobes, and Horn Strobes SpectrAlert®Advance selectable-output horns,strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTF',4N�ert A N Features The SpectrAlert Advance series offers the most versatile and •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting •Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance can •Automatic selection of 12-or 24-volt operation at 15 and 15/75 meet virtually any application requirement. candela •Field-selectable candela settings on wall and ceiling units:15,15/75, Like the entire SpectrAlert Advance product line,horns,strobes, 30,75,95,110,115,135,150,177,and 185 and horn strobes include a variety of features that increase their •Horn rated at 88+dBA at 16 volts application versatility while simplifying installation.All devices •Rotary switch for horn tone and three volume selections feature plug-in designs with minimal intrusion into the back box,which make installations fast and foolproof while virtually •Universal mounting plate for wall and ceiling units eliminating costly and time-consuming ground faults.Furthermore, •Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed,protecting devices •Electrically compatible with existing SpectrAlert products from damage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING O 41i> MEA roved (indstrobes) LISTED APPROVED approved 7125-16531887125-1653:186(hornoor strobes, 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16x 411/16 x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm Lx 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS,TRCW-HS) 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12V nominal only for 15 and 15/75 cd. A05-0395-007 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. A05-0395-007 SpectrAlert Advance Dimensions 1156111 dH Wall-mount horn strobes Ceiling-mount horn strobes 7.1" r-2.251 5.05"� �—2.231 \ Dia. 0 1 I I 70 0 o 0 a\\ r 00000 I, 5.98" ! r I0 a , o l :0 00 ¢ \o o di/ c o ��� o t Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Strobes P2R*t 2-Wire Horn Strobe,Standard cd$,Red SCR Strobe,Standard cd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2W* 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standard cd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4-Wire Horn Strobe,Standard cd,White HW Horn,White Wall Strobes Accessories SR*t Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red SRH*t Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White SW* Strobe,Standard cd,White BBSC-2 Back Box Skirt,Ceiling,Red SWH* Strobe,High cd,White BBSCW-2 Back Box Skirt,Ceiling,White Ceiling Horn Strobes TR-HS Trim Ring,Wall,Red PC2R* 2-Wire Horn Strobe,Standard cd,Red TRW-HS Trim Ring,Wall White PC2RH 2-Wire Horn Strobe,High cd,Red TRC-HS Trim Ring,Ceiling,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White TRCW-HS Trim Ring,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red PC4RH 4-Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SR. t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *--. SYSTEM m2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensoccom for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0395-007.4/09•#2132 SYSTEM �$ SENSOR , . \,), `t rR t ) Indoor Selectable- y•= Output Strobes and ,� Horn Strobes for �� rr, •, ....... Ceiling Applications lications SpectrAlert®Advance audible visible notification products 311 are rich with features guaranteed to cut installation times SPECTR�ert and maximize profits. 6,464r A . c Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela • Field selectable candela settings on ceiling units: 15, 15/75,30, Like the entire SpectrAlert Advance product line,ceiling-mount strobes and horn strobes include a variety of features that increase 75,95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for ceiling units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING O ® MEA 0 approved ( e LISTED APPROVED 7125-16531887125-1653:186)horn indoor strobesstrob,s) 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS, 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) TRCW-HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00501 SpectrAlert Advance Dimensions 7.1" 14-2.251 6.8" \ Dia. � Dia. k� ILII j__) /70 0 o ° C ,' . .,1„i 1't111.t 2 Inill i9 I IL 1 \\b ° Cy T (\r :/ C Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe,Standard cd,Red SCR Strobe,Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White PC2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White TRC-HS Trim Ring,Ceiling,Red TRCW- Trim Ring,Ceiling,White HS Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. $"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *Th_ SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS00501•3/12 �Gamewell Series 95 Bases Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base, the XP95 *y family has a base to meet building aesthetics, constraints, • retrofit limitations or functional needs. The device address :„10011111:::1 ; is held in the base, ensuring that the device address will + J. not be changed no matter how often a detector is replaced, _ and verifying a consistent match between device type and r device address. Each XP95 analog addressable head is compatible with a wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only" fit. Relay and sounder bases can be addressed and • Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. • Base options include: — 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile Programming bases feature'one-way"fit with low insertion force — 6.0"(15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group • The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base • head is inserted into the base,the address is automatically Address is set by patented XPert addressing card • relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors. The bases SIGNALING have a wide interior diameter for ease of access to wires 0 and terminals.The design of the base is such that the LISTED S1195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.al page 1 of 2 Installation (Continued) Specifications (Continued) sensor will fit in only one way, and a simple clockwise motion(without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Model: XP95-B6R4 XPert addressing card as a means for programming and Alarm Current: 0.0036 A maintaining the sensor's address. Standby Current: 2 pA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-B4 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Captive Terminals: Yes cover/plaster ring (Raco 727 or equal).The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5" (8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model:XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030 A square backbox(Raco 190 or equal). Standby Current: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048 m) Captive Terminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-I) or photoelectric (Gamewell-FCI model XP95-P) smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-B4 4.0"(10.16 cm) mounting base with model XP95-T)with one of the several addressable mount- XPert addressing card XP95-B6R4 6.0"(15.24 cm) relay base(four- ing base available options. The combination sensor head wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0"(15.24 cm) ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED (24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: XP95-B4 Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes 6" Base Model:XP95-B6EZ Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2048 Rev.al page 2 of 2 www.gamewell-fci.com Gamewell XP95-P Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- tric sensor operates with the Gamewell-FCI analog addres • - sable Fire Alarm Control Panels (FACPs). The • photoelectric sensor digitally transmits its address and the Y 1 chamber's analog values to the FACP for analysis. The • photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled and turns on continuously when the device is in alarm. � I / Operation 01.4— / The XP95-P photoelectric sensor constantly monitors its _ sensing chamber and its internal electronics. The results 0 are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber.When • Fits 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile smoke enters the chamber, it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- • Audible alarm sounder base acteristics and density. As the smoke content in the cham- • Four-wire relay base ber increases, the signal from the photo diode receptor • Address is stored in the sensor base increases. This information is processed and conditioned • Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally • Two-color status LED transmitted to the FACP. • Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are • Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. L ® MEA LISTED Approved 51195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fcLCom CS-2054 Rev.al page 1 of 2 Operation (Continued) Ordering Information The XP95-P photoelectric device is connected to a two- Model Description wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor, analog voltage, and is insensitive to loop connection polarity. A addressable (55000-650) remote LED indicator may be connected. The device is XP95-B4 4.0"(10.16 cm)mounting base with compatible with point-or group-addressable relay and XPert addressing card (45681-2101) sounder bases. XP95-B6R4 6.0"(15.24 cm)relay base (four-wire)with XPert addressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install, where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available. The 30203 Remote LED (24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications Standby Current: 340 pA Alarm LED Current: 0.00434 A Remote Alarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F(0° C to 60° C) Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft. (9.1 m)spacing guidelines in NFPA 72 Chapter 2. However,this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.al page 2 of 2 www.gamewell-fci.com � Gamewell XP95-T Fe' FIRE CONTROL INSTRUMENTS by Honeywell Description Analog Addressable Thermal Sensor The Gamewell-FCI XP95-T Analog Addressable Thermal Sensor operates with the Gamewell-FCI 600 Series analog • addressable fire alarm control panels (FACPS). The Series XP95-T thermal sensor digitally transmits its address and the chamber's analog temperature value to the FACP for • • analysis. Thermal sensors are readily distinguished from smoke by the open webs in the housing designed to allow for free movement of air around the exposed thermistor. • Operation —�. - U The XP95-T thermal sensor constantly monitors its sens- XP95-T ing element as well as its internal electronics. The results are digitally reported along with the unit's address through the integral communication electronics located in the sen- Features sor head. The thermal sensor monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. This • Compatible with the Gamewell-FCI 600 Series analog signal is processed and conditioned by an on-board addressable control panels advanced technology ASIC that digitally transmits the • Fits 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra low—profile, ambient temperature data to the FACP when interrogated. and E-Z fit bases • Audible alarm sounder base Trouble and Alarm conditions of the XP95 sensors are • Address is stored in the sensor base determined at the FACP. The status information of each • Address is set by XPert addressing card sensor is analyzed for off—normal conditions by the control • Two-color status LED panel. If the sensor reports a condition that matches its • Fixed point or rate-of-rise functions programmed trouble signature, the FACP will report that • Timed temperature increase causes an alarm the sensor is in trouble and will follow its programmed • Thermal adjustability programming response sequence. Likewise, if the status reported • Optional remote LED matches the alarm signature, the FACP will follow the pro- grammed alarm response for the specific device in alarm. When a sensor is in alarm,the integral LED in the sensor's housing will light continuously. The XP95-T thermal sensor is calibrated to return a normal air temperature analog value to the FACP at 77° F. The device connects to a two—wire loop circuit carrying both An ISO 9000-2000 Company SIGNALING data and a 117 to 28 VDC supply voltage, and is insensi- U tive to loop connection polarity. LISTED 52527 APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2055 Rev.al page 1 of 2 Operation (Continued) Ordering Information A remote LED indicator can be connected. The device is compatible with point or group—addressable relay and Model Description sounder bases. XP95-T Thermal sensor analog addressable (55000-450) Engineer's Specifications XP95-B6EZ 6.0"(15.24 cm) ultra—low—profile EZ-Fit mounting base with XPert card (45681-250) The contractor shall furnish and install, where indicated on XP95-B4 4.0"(10.16 cm) mounting base with XPert the plans, electronic thermal sensors with one of the sev- Addressing Card (45681-210) eral addressable mounting base options available. The XP95-B6R4 6.0"(15.24 cm) relay base(four-wire)with combination sensor head and twist—lock mounting base XPert addressing card shall be UL Listed and UL Listed as compatible with the XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert Gamewell-FCI 600 Series analog addressable fire alarm addressing card and audible alarm sounder control panels. 71112 Additional blank XPert addressing cards The base shall permit free interchange of sensor heads 30203 Remote LED (24 V) without requiring any additional wiring or additional pro- gramming of the head or base.The sensor shall contain an integral LED that shall latch in when the unit goes into alarm. It shall be the Gamewell-FCI model XP95-T. Specifications Standby Current: 250 pA Alarm LED Current: 4 mA Remote Alarm Output: 4 mA @ 5 VDC Temperature Range: -4°F to 154°F Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Smooth ceiling 60ft. (18.288 m)to walls 25 ft. (7.62 m) Thermal Sensor Performance Features: 1)Thermal sensors have a thermal adjustability programming range from 25°C to 90°C (77°F to 194°F)in 1°C increments. 2)Thermal Sensors have a thermal rate-of-rise feature.When enabled in programming, should the XP95-T sensor increase temperature by greater than 15°F in less than one minute, an alarm will be generated. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2055 Rev.al page 2 of 2 www.gamewell-fci.com PRELIMINARY MS-95, MSO5-T Gamewell FIRE F' I by Honeywell Description Addressable Manual Pull Station The Gamewell-FCI MS-95/MS-95T Addressable Manual Pull Station is a non-coded, single-action, manual pull sta- tion with a key-lock reset feature. Its rugged toggle switch design offers exceptional resistance to accidental alarms caused by a sudden vibration or shock.The MS-95 can be FIRE C.. FIRE used for surface and semi-flush installations. It is compati- ble with the following Gamewell-FCI addressable fire alarm PUSH control panels(FACPs). • 600 Series, IdentiFlex 602 PU L L • E3 Series®, IL195-E3 Series • S3 Series, SLC95-PM The MS-95/MS-95T are approved to UL®Standard 38 for Gamewell-FCI manual pull stations that comply with the architectural requirements in all building interiors,and is readily accessi- ble in a fire emergency. In addition, the pull stations meet the following American with Disabilities Act(ADA),AG Controls and Operating Mechanisms Guidelines MS-95/MS-95T (Section 4.1.3). Features • 5 lb. (2 kg.) maximum pull force. • Mounting installation height of 4 ft. (1.2m),(42"(106.48 cm) min.to 48"(121.92 cm)max. off the center). • Complies with UL®Standard 38 Operations • Meets ADA AG Controls and Operating Mechanisms To activate the manual pull station, press the lever Guidelines requirements for a 5 lb. pull force and (marked, "PUSH") inward. Then, pull the handle (marked, complies with the 4 ft. (1.2m) mounting height "PULL") downward until the handle locks into place. After • Compatible with the following Gamewell-FCI, the handle is pulled, this lever locks-in the alarm position addressable fire alarm control panels (FACP): and remains there until it is manually reset. -600 Series, IdentiFlex 602 To reset the alarm lever and release the front cover of the - E3 Series®, IL195-E3 Series pull station, insert and turn the key on the front of the pull -S3 Series, SLC95-PM station. This action unlocks the front cover and lowers the • Constructed of durable die-cast metal cover. After the front cover is lowered, the toggle switch is • Designed for use as a compact unit that blends with the reset. interior An optional breakglass rod may be used with all pull sta- • Contains a recessed pull lever that prevents accidental tions. The self-clearing design prevents jamming of the operation station and there is no danger to the operator from broken • Includes a key reset option particles of glass. Space is provided within the station • Used for surface or semi-flush installations housing for storage of an additional replacement glass rod. • Shows a visible status LED The MS-95 connects directly to the analog addressable cir- • Provides field programming cuit via two wires. The electronic circuitry has been • Offers both wire and terminal block, single action designed to transmit data that can be interpreted as the options following three output operations: • Available in the terminal block model (MS-95T) • normal standby operation • alarm operation • trouble operation In its standby mode of operation, the pull station's circuit monitors the switch for alarm conditions. A trouble condi- tion occurs when the pull station is addressed by the con- trol panel and either reports back a trouble response or does not respond at all. With the standard priority interrupt SIGNALING feature, the MS-95 will report its condition instantly to the Gamewell-FCI FACP. S Rvt� E3 Series®is a registered trademark of Honeywell International Inc. LISTED UL®is a registered trademark of Underwriter's Laboratories,Inc S281 7300-1703:0136 iso 9001 ENGINEERING 8 GAMEWELL-FCI QSGIITT SYSTEMS 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2015 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2053 Rev. D page 1 of 2 Programming Ordering Information To program the MS-95 manual pull station to the address switch settings, set the address DIP switch on the device's printed circuit board. All other programming is accom- Part Number Description plished at the fire alarm control panel. MS-95 Analog addressable manual pull station Engineer's Specifications MS-95T Analog addressable manual pull station with terminals The analog addressable manual pull station shall contain the electronic interface circuitry required for individual 30653 Double action option device identification, alarm reporting and trouble supervi- Key reset option sion. It shall communicate to the main control panel via the 30653-02 Key reset/double action option analog addressable circuit. The single-action station shall 27060 Breakglass rod consist of a die-cast aluminum housing fitted with a pull out 28762 Surface backbox lever which, when operated, locks in position after activat- 50397G Weather proof gasket for MS-95 station ing an alarm initiating contact. 72198 NYC manual station backplate with 1"(2.54 cm)white stripe Specifications 71961 Backbox, surface for key reset options Standby Current: 0.0008 A(0.8 mA) Alarm Current: 0.0015 A(1.5 mA) Operating Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93%, non-condensing Power: 24 VDC Material: Die-cast aluminum Finish: Fire alarm red, smooth gloss enamel. Raised cast letters are high- lighted. Target background for pull lever is white glossed enamel Dimensions: MS-95: 4.75" H x 3.25"W x 1 1/8" D (from the backplate) (10.79 H x 8.25 W x 2.99 D cm) MS-95T: 4.75" H x 3.25"W x 1 1/8" D (from the backplate) (10.79 H x 8.25 W x 2.99 cm) MS-95 with key reset option: 6.25"H x 3.25"W x 2.0"D(from backplate)with Cat 60 Key (15.88 H x 8.25 W x 5.08 D cm) Surface Backbox P/N: 28762: 4.625" H x 3.25"W 2.375" D tapped for 3/4"(1.9 cm)conduit (11.75 H x 8.25 W x 6.03 D cm) Surface Backbox P/N: 71961: 6.25" H x 3.0"W x 3.25" D (15.88 H x 7.6 W x 8.25 D cm) GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2053 Rev.D page 2 of 2 www.gamewell-fci.com