HomeMy WebLinkAboutB14-0153_heat calcs_1421429100.pdf 4,04 OF kt RadiantWorks Professional Mechanical Summary Report ' r + Project Information Contact Information Project Number Designed By Brent Hettinger Project Quote Company Name George T.Sanders irt m Project Name Hoyt-Young Phone Number 970-468-8254 moo417 Designed For grier. ell" VAIL,CO (Colorado) Pump Specs 01/16/15 , Zone Name Flow Head Zone 1 1.1 GPM 1 ft Zone 2 0.5 GPM 0.2 ft 20 120°F Zone 3 0.5 GPM 0.5 ft 20 120°F Zone 4 1.5 GPM 2.8 ft 20 105°F Zone 5 0.8 GPM 1.7 ft 20 120°F Zone 6 0.7 GPM 1.3 ft 20 130°F Zone 7 0.5 GPM 0.3 ft 20 120°F Zone 8 0.4 GPM 2.1 ft 20 120°F Zone 9 0.8 GPM 1.6 ft 20 120°F Zone 10 1.5 GPM 1.5 ft 20 120°F Zone 11 0.8 GPM 1.4 ft 20 120°F Zone 12 0.4 GPM 0.2 ft 20 103.5°F Zone 13 0.8 GPM 0.8 ft 20 120°F Zone 14 0.8 GPM 0.8 ft 20 120°F Zone 15 0.9 GPM 2.3 ft 20 120°F Heated Area Descriptions Application Construction Heated Area Product Totals Zone 1 <> Room List(Fam 105,Kit 104,CIst 103,Bath 108) Radiant Heating Slab 861 ft2 (4)250'Lengths of 1/2" None RadiantPEX+ Zone 2 <> Room List(Bed 107, Hall 106) Radiant Heating Slab 254 ft2 (2)150'Lengths of 1/2" None RadiantPEX+ Zone 3 <> Room List(Bed 109, Bath 110) Radiant Heating Slab 281 ft2 (2)150'Lengths of 1/2" None RadiantPEX+ Zone 4 <> Room List(Garage) Radiant Heating Slab 653 ft2 (3)250'Lengths of 1/2" None RadiantPEX+ Zone 5 <> Room List(Living 218) Radiant Heating ThinSlab 311 ft2 (2)250'Lengths of 1/2" None RadiantPEX+ Hoyt-Young.rad Copyright(c)Watts Radiant 2008 Page 1 of 4 4,04 OF RadiantWorks Professional Mechanical Summary Report V+ Zone 6 <> Room List(Fathers Bed 217,Bath 215,Closet 216) 44 illiltir 13 Radiant Heating ThinSlab None Zone 7 <> Room List(Kit 204, Den 208, Pwdr 206) Radiant Heating ThinSlab Crer. Alt None Zone 8 <> Room List(Entry) Radiant Heating ThinSlab None 01/16/15 , Zone 9 <> Room List(Dining 203) Radiant Heating ThinSlab „ None RadiantPEX+ Zone 10 <> Room List(Living 202) Radiant Heating ThinSlab 608 ft2 (4)250'Lengths of 1/2" None RadiantPEX+ Zone 11 <> Room List(Bed 313, Bath 311) Radiant Heating ThinSlab 379 ft2 (2)200'Lengths of 1/2" None RadiantPEX+ Zone 12 <> Room List(Hall 308,Bridge 306, Laundry 307) Radiant Heating ThinSlab 249 ft2 (2)150'Lengths of 1/2" None RadiantPEX+ Zone 13 <> Room List(M.Bed 303) Radiant Heating ThinSlab 334 ft2 (3)200'Lengths of 1/2" None RadiantPEX+ Zone 14 <> Room List(M.Bed 303) Radiant Heating ThinSlab 334 ft2 (3)200'Lengths of 1/2" None RadiantPEX+ Zone 15 <> Room List(M.Bath 302, M.Clst 305) Radiant Heating ThinSlab 298 ft2 (2)250'Lengths of 1/2" None RadiantPEX+ Heating Load Summary Tube Back/Edge Total Total Spacing Intensity Losses Required Provided Supp. (in) (BTU/h•ft2) (BTU/h•ft2) (BTU/h) (BTU/h) Needed Zone 1 8795 21620 Fam 105,Kit 104,CIst 103 12 10.13 2.94 8298 19855 Bath 108 12 11.82 5.54 497 1765 Hoyt-Young.rad Copyright(c)Watts Radiant 2008 Page 2 of 4 4,04 OF RadiantWorks Professional Mechanical Summary Report V+ Zone 2 4441trill 1 el Bed 107 12 16.16 3.z Hall 106 12 11.68 3.' igm Zone 3 1,17 Bed 109 12 15.22 3.: Bath 110 12 18.6 3.: Zone 4 Garage 12 20.56 2.f Zone 5 01/16/15 , Living 218 8 22.84 2 Zone 6 b5/3 1U144 Fathers Bed 217 8 27.4 2.83 4795 5554 Bath 215 8 27.37 2.50 1560 3858 Closet 216 8 8.73 2.02 218 732 Zone 7 4604 10708 Kit 204, Den 208, Pwdr 206 12 12.65 0.97 4604 10708 Zone 8 4112 10925 Entry 12 18.69 1.02 4112 10925 Zone 9 7557 9181 Dining 203 8 28.52 1.35 7557 9181 Zone 10 13902 20989 Living 202 8 22.87 1.21 13902 20989 Zone 11 7571 12055 Bed 313 12 20.03 1.30 5427 6874 Bath 311 12 19.85 1.05 2144 5181 Zone 12 3909 4645 Hall 308,Bridge 306 12 12 0.75 2449 3181 Laundry 307 12 32.44 0.89 1460 1464 Zone 13 7789 8801 M.Bed 303 8 23.32 1.45 7789 8801 Zone 14 7789 8801 M.Bed 303 8 23.32 1.45 7789 8801 Zone 15 4926 12242 M.Bath 302 8 16.84 1.13 3133 9718 M.Clst 305 8 16.01 36.65 1793 2524 Project Summary Total Flow: 12.2 GPM Total System Head: 2.8 ft Hoyt-Young.rad Copyright(c)Watts Radiant 2008 Page 3 of 4 404 OF RadiantWorks Professional Mechanical Summary Report 4 V+ Boiler Load: 121562 BTU/h i ilillor 13 t ri Total System Volume: 77 Gallons Total Heated Area: 5668 ft2WI m :75A AT 6°., Ig' Please verify all project information for accuracy. Oj l 1470) Signature: 01/16/15 Hoyt-Young.rad Copyright(c)Watts Radiant 2008 Page 4 of 4