Loading...
HomeMy WebLinkAboutB14-0153_S6_1421429100.pdf .4;ifie. 4.•4 AITINIIke4P To i'r'e 2x6 STUDS @ 16" O.C. W/ al:IS kr 5" 5" Y2" PLYWD. OR OSB ' / / SHEATHING 47* lb ® ® oci) 1Ysx11�/s OSB RIM 30'-25/s Va l " I ,,, ,,/ 4,,,0 1 T.O. PLYWD. 0 0 \ I�0 COL. PER PLAN Y2"0x10" A.B.'s @ 48" O.C. I 01/16/15 IN CONT. TREATED 2x6 I \ I-JOIST BLKG. PANELS @ 12" N I 1 4" NON-SLOPING 29'-EY2 ' I 24" IN FIRST JOIST // I I BASE It: 5/e"x10"x0'-10 W/ SLAB 0 SIM. T.O.W. e 1Ysx117/s OSB RIM SPACE W/ (5)-8d NAILS I 1 (4)-5/s"0x12" TITEN HD �� Ii. INTO EA. PANEL, TYP. 1 I ANCHORS ON 1" MIN. SHIM & BASE It: 5/s"x10"x0'-10 L 117/8" I-JOISTS PER PLAN N 2 -0 COL. PER PLAN c rn r \ — NON-SHRINK GROUT 4 DWLS x o W/ (4)_Y2»� x 10> I I K ��\� cp, 1 in # I 28'-0 i I A.B.'s ON 1" MIN. SHIM 1 �`/'%�;\�\/\��/\ cn °' a, @ 24" O.C. N > T.O. PLYWD. / 1� & NON-SHRINK GROUT Y2" EXP. MAT'L, TYP. ii rn4's @ 12" EA. WAY II # - z (4)-#5's VERT. I Z -0 ° STONE VENEER •'' : I I Li '• ': ''o°� o • #5's VERT. @ 16" O.C. Z c = Q /\ • . °° • I"' \ PER ARCH. /\/\/\ _ ! 11�/" I—JOISTS PER PLAN \/\/\�\/i \�/\/\/ / /, � '� ` �— • \/iii \ s \/\/\/\\ �/ / / /. r r, • too J \�\\/\j/ ° /.i�r. 1/0 �o o N \oma! \r,\•4,,a \�i/\�//\�\ j\%j\%j%j\`' `,,1 i , ,/ N • i o\�/\�/�,/ /� i a c L 4x 4xY4 W/ (1)—5/8"0 x 4" EXP. _1 • Z c �o SEE SCHED. FOR REINF. N I I ANCH. EA. SIDE EQ. EQ. (2)-#5's CONT. @ BOT. / / / r.,� 0 - N I I ° � � �� „ SCHED. WIDTH 4" 4" 2 L ` 0 (c) x0 1'-0" °� z 12 CONC. PIER / / 2 CC U 2 ° 1 II (4)-#5 DWLS x I to N 5 SCALE: 3/4" = 1'-0" ° 11 TYPICAL THICKENED SLAB @ EXT. PATIO SCALE: 3/4" = 1'-0" 4 II I 6 S6 S6 0 — _I L — #5's CONT. HORIZ. @ 16" O.C. I 2x6 STUDS @ 16" O.C. W/ Y2" 2x6 STUDS @ 16" O.C. W/ Y2" I-JOIST BLKG. PANELS @s_ i PLYWD. OR OSB SHEATHING PLYWD. OR OSB SHEATHING 24" IN FIRST JOIST " J 1Ysx117/s OSB RIM SPACE W/ (5)-8d NAILS 1 #6 DWLS x r SEE SCHED. FOR REINF. 1Ysx11 7/s OSB RIM @ 12 O.C. CONC. SLAB \ , INTO EA. PANEL, TYP. 1 EQ. EQ. 1'-2 PER PLAN 5 M / ' 2x DECKING PER ARCH. ->cl 28'-0 ob 29'-85/8 � 29'-8% T.O. PLYWD. (2)-#5's CONT. HORIZ. • T.O. SLAB ° _ ' " T.O. PLYWD. /I SEE SCHED. 1I: "IX TOP & BOT. 4 4Y2" EXP. MAT'L, TYP. 0 i N' t 8 SCALE: 3/4" = 1'-0" OJ)TYP. , I N #5's TRANSVERSE © 5" CONC. SLAB PER PLAN L —�, 26'-97/8 * 16" 0.C. 21'-0 (N) TRTD. PLYWD. \!� Ipl° 28'-6Y2 DECK JOISTS PER PLAN lI.° T.O.W. N _1 �, • '// ° T.O. SLAB • @ CONC. SLAB T.O.W. ° 11 /8" I-JOISTS PER PLAN 20'-7 \ U ° .. y J 11�/s" I-JOISTS PER PLAN / i\\i T.O.F. • ;! ,' 40'�� 2x6 STUDS @ 16" O.C. W/ \\\ _ ;. ti; ° a • o \i, / CRAWLSPACE rararara,o (24 Y2„ PLYWD. OR OSB LEDGER PER PLAN \4x\j\\/j •' `=' I -:":'-‘-1-,,,,�_ ; ,//,/,�, Y2 0x10 A.B.'s @ 48 O.C. I° ,> » • .° (6)-#5 s CONT. LONGIT. 0 IN CONT. TREATED 2x6 h' SHEATHING i 4 4 Y2'�Ox10" A.B.'s @ 48" O.C. IN c CONT. TREATED 2x6 �' v a ° ��� vCD I _ Y2"0x10" A.B.'s © 48" O.C. nv PERIMETER DRAIN PER F IN CONT. TREATED 2x6 R ' #5's CONT. HORIZ. @ 16" O.C. SOILS ENGINEER 1'-9" / 8" 1'-0" r,� U / 10 SCALE: 3/4" = 1'-0" Y2" EXP. MAT'L, TYP. „ db 30'-2 #5 DWLS x E #5's VERT. @ 16" O.C. 0 T.O.W. .\r'- Ire ^ CONC. SLAB PER PLAN @ 24" O.C. SCALE: 3/4" = 1'-0" v. I� VARIES " 0 STONE VENEER \/\ \ \/ fF� G� T.O. SLAB 6 ,,,<' :6 L) PER ARCH. \,x\�/� ° as/ �° ›/\\/,/ TOP &5'sBpCONT. HORIZ. T. 2x6 STUDS @ 16" O.C. i/%i%.% $ /.\/\ / (1)-#5 CONT. HORIZ. @MID-HT. T.O.F. " 0.4'411t v� CONT. L PER SCHEDULE O Y2" EXP. MAT'L, TYP. SEE SHEET S2 Vb a r % A = 30'-25/s I PERIMETER DRAIN 4" 8" 4" 11 VARIES T.O. PLYWD. 5 DWLS x PER SOILS ENGINEER AL `j= Id © 48" O.C. w T.O. SLAB ° ° 0 30'-03/s 6" 1,-4„ �� ® TYP. \ bs8•� p . +; T.O.W. g`v'�4 ., i t (2)-#5's CONT. HORIZ. 4 SCALE: 3/4" = 1'-0" 2x6 STUDS @ 16" O.C. W/ Y2" a) \\/\\�\\/\\/° TOP & BOT. . 25'-0 S6 PLYWD. OR OSB SHEATHING I-JOIST BLKG. PANELS @ �!\�%\ • T.O.F. o�• '� I-JOIST BLKG. PANELS @ 24" IN FIRST JOIST D <` 4 ° 4 11�/s" I-JOISTS PER PLAN ao ;',O 24" IN FIRST JOIST SPACE W/ (5)-8d NAILS b a 2x6 STUDS @ 16" O.C. W/ Y2 SPACE W/ (5)-8d NAILS 1Ysx11 /s OSB RIM INTO EA. PANEL, TYP. I ) N PLYWD. OR OSB SHEATHING INTO EA. PANEL, TYP. a Y2"0x10" A.B.'s @ 48" O.C. PERIMETER DRAIN 2x DECKING PER ARCH. �C_ 30'-25js IN CONT. TREATED 2x6 h' 4" 8" 4" 28'-0 �� T.O. PLYWD. 4 PER SOILS ENGINEER 1Ysx11 /s OSB RIM y 11- 1 ZII II>� °° A 6<I ' ' �sf` T.O. PLYWD. ‘11 , i 1'-4" I ® TYP. ; I;I Y2"0x10" A.B.'s @ 48" O.C. I' I ® 29'—OY2 4 4IN CONT. TREATED 2x6 * #5's VERT. @ 16" O.C. 7 3 " = i. / T.O.W. SCALE: /4 1'-O" 26'-9/s I DECK JOISTS PER PLAN I • S6 T.O.W. �I r . L 1174" I-JOISTS PER PLAN 117//" I-JOISTS PER PLAN LEDGER PER PLAN e ///'\�,° Y2"0x10" A.B.'s © 48" O.C. . \/�\\ A a IN CONT. TREATED 2x6 It designed byJMO #4 DWLS x o / 2 -0 CONC. SLAB PER PLAN • /° ° • w!/ / /\\/ drawn by CLR 5 5 @ 24" O.C. N /v A vr�� TDH ��� checked by . _,L 29'-6 J issued T.O. SLAB ° ° .. rte. '4 00 ° ° ° a .• #5's• VERT. © 16" O.C. N� PRICING 2/4/14 28 -10 < �/ .j4; •o'.4 4 ° #5's VERT. @ 16" 0.0. 4" 4" REVISED 2/24/14 5's CONT. HORIZ. @ 16" O.C. !�%m% ow% ���� (1)-#4 CONT. HORIZ. # /`/` REVISED 4/15/14 #5 DWLS x o PERMIT 4/21 /14 #6 DWLS x r ° A (1)—#5 CONT. HORIZ. @ MID-HT. 4" `4 CRAWLSPACE @ 16" 0.C. #5's CONT. HORIZ. @ 16" O.C. @ 12" O.C. 8" REVISED 5/14/14 4" 6'� a REVISED 6/13/14 2 -4 2 5 s CONT. HORIZ. #5's CONT. HORIZ. @ 16" O.C. TOP & BOT. • ' REVISED 6/24/14 (2)-#5's CONT. HORIZ. �• , 4,x,4 i #5 DWLS x _ \ Y2„ EXP. MAT'L, TYP. @ 48" 0.C. � TOP (Sc BOT. Y2" EXP. MAT'L, TYP. J REVISED 7/21 /14 6 5 DWLS x r •° #5's TRANSVERSE @ 5" CONC. SLAB PER PLAN#5s TRANVERSE @ 5 CONC. SLAB PER PLAN (2)-#5's CONT. @ 24 O.C. \ 16 O.C. 21 _0 REVISED 7/25/14 16 o.c. 21'-0 ,/ NEVISED 7/31 /14 ° $ 25'-0 HORIZ. TOP 8c BOT. 6 \�\\\\\ 20'-7 c� ° ° T.O.T.o. SLAB T.O. SLAB \ ' % - �okba� REVISED 9/9/14 20'-7 `� e T.O.F. ;-q•f wtti; o \\/,/ / (2)-#5's CONT. T.O.F. o,z. ,. a •• •.clo•.z � ,.e4�o A:04; ° 4 •,��� § :,: a°• ,�, HORIZ. TOP & BOT. o ,0 /"=./�t T.O.F. s °' ,: •• oO 20'-0 \ I a'...:.� A i/D i! (5)-#5's CONT. LONGIT. o '0'` ° ° - , a ' './. ../ .°%46' - A ° • T.O.F. o -P , ° e ' \�/ \ sheet a° A ��� (8)-#5's CONT. PERIMETER DRAIN 00 +0 6 a ° �� 4" 8" 4" HORIZ. PER SOILS ENGINEER ° _ / / PERIMETER DRAIN 1'-6" 8" 6" ce PERIMETER DRAIN PER PER SOILS ENGINEER i M0 SOILS ENGINEER 2'-0" 10" 2'-O" "' 0 1'-4» PERIMETER DRAIN PER 4" 8" 4" / / / / SOILS ENGINEER / / / / 2'-8" � ° 4'-10" 1'-4" �� �� / 9 SCALE: 3/4" = 1'-0" 6 SCALE: 3/4" = 1'-0" 3 / SCALE: 3/4" = 1'-0" 1 SCALE: 3/4" = 1'-0" S6 S6 S6 S6 J03 #1401 - 09