HomeMy WebLinkAboutE16-0159 load calcs General Lighting 1070X3 3210 Small appliance and laundry 3X1500 4500 Appliances with new microwave 3000 Range 8500 Dryer 5000 Total 24210 First 8kva 100% 8000 Remainder at 40% 6484 Electric Heat 6000 Total Load 20484/208 = 98.48 amps Existing Service 125 amps Load Calc For 1509 Simba Run Per 220.83 NEC Existing Dwelling Unit Avalanche Electric TOV License 188E for 1502 Simba Run