Loading...
HomeMy WebLinkAboutB14-0326_Nugget B Certificate_1409667960.pdf REScheck Software Version 4.5.0 Compliance Certificate Project Nugget Lane Duplex - Side B Energy Code: 2012 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 3,874 ft2 Glazing Area 21% Climate Zone: 6 (9248 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 4288 Nugget Lane Bryan Desmond Vail,CO 81658 Desmond Homebuilders P.O. Box 3518 Eagle,CO 81631 970-376-7162 bryan@desmondhomebuilders.com Compliance:Passes using UA trade-off Compliance: 0.9%Better Than Code Maximum UA: 555 Your UA: 550 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies • Gross Area CavityGlazing Assembly or Cont, or Door UA Perimeter R-Value R-Value U-Factor FL Slab: Slab-On-Grade:Heated 118 10.0 0.684 81 Insulation depth:4.0' Crawl Floor: Slab-On-Grade:Unheated 67 10.0 0.684 46 Insulation depth:4.0' Floor Above Garage:All-Wood joist/Truss:Over Unconditioned Space 650 38.0 0.0 0.026 17 Crawl Wall: Solid Concrete or Masonry 333 10.0 10.0 0.042 14 Wall height: 5.0' Depth below grade: 5.0' Insulation depth: 5.0' Basement Wall: Solid Concrete or Masonry 277 15.0 10.0 0.033 9 Wall height: 8.5' Depth below grade: 8.5' Insulation depth: 8.5' Basement Wall To Crawl: Solid Concrete or Masonry 89 15.0 0.0 0.062 6 Wall height: 3.5' Depth below grade: 3.5' Insulation depth: 3.5' Basement Wall Unfinished: Solid Concrete or Masonry 365 0.0 10.0 0.053 19 Wall height: 8.5' Depth below grade: 8.5' Insulation depth: 8.5' Garage Wall:Wood Frame, 16"o.c. 174 23.0 0.0 0.055 8 Project Title: Nugget Lane Duplex-Side B Report date: 08/06/14 Data filename: P:\Team Folders\WD My Book\AE\AE Inc\Jobs\AE Projects\10479C Nugget Page 1 of 2 Residence\Nugget Side B.rck Gross Area Glazing Assembly or cavity cont. or Door UA Perimeter R-Value R-Value U-Factor Door BO1:Solid 23 0.330 8 SLN Wall: Wood Frame, 16" o.c. 593 23.0 0.0 0.055 27 Window B25:Wood Frame:Double Pane with Low-E 34 0.300 10 Window B24:Vinyl Frame:Double Pane with Low-E 30 0.300 9 Window B23:Wood Frame:Double Pane with Low-E 13 0.300 4 Door Glass B07:Wood Frame:Double Pane with Low-E 24 0.400 10 SLE Wall:Wood Frame, 16"o.c. 266 23.0 0.0 0.055 12 Window B22:Wood Frame:Double Pane with Low-E 25 0.300 8 Window B21:Wood Frame:Double Pane with Low-E 25 0.300 8 SLW Wall:Wood Frame, 16" o.c. 56 23.0 0.0 0.055 3 TLN Wall:Wood Frame, 16" o.c. 920 23.0 0.0 0.055 37 Window B31:Wood Frame:Double Pane with Low-E • 24 0.300 7 Window B32:Wood Frame:Double Pane with Low-E 24 0.300 7 Window B33:Wood Frame:Double Pane with Low-E 72 0.300 22 Window B34:Wood Frame:Double Pane with Low-E 33 0.300 10 Window B36:Wood Frame:Double Pane with Low-E 20 0.300 6 Window B37: Wood Frame:Double Pane with Low-E 15 0.300 5 Window B38: Wood Frame:Double Pane with Low-E 40 0.300 12 Window B39: Wood Frame:Double Pane with Low-E 15 0.300 5 TLE Wall:Wood Frame, 16" o.c. 389 23.0 0.0 0.055 15 Window B26:Wood Frame:Double Pane with Low-E 24 0.300 7 Window B27: Wood Frame:Double Pane with Low-E 24 0.300 7 Window B28:Wood Frame:Double Pane with Low-E 24 0.300 7 Window B29:Wood Frame:Double Pane with Low-E 24 0.300 7 Window B30:Wood Frame:Double Pane with Low-E 24 0.300 7 TLW Wall: Wood Frame, 16"o.c. 436 23.0 0.0 0.055 19 Window B35: Wood Frame:Double Pane with Low-E 40 0.300 12 Window B40: Wood Frame:Double Pane with Low-E 19 0.300 6 Window B41:Wood Frame:Double Pane with Low-E 23 0.300 7 TLS Wall:Wood Frame, 16"o.c. 40 23.0 0.0 0.055 2 Flat Ceiling: Flat Ceiling or Scissor Truss 738 49.0 0.0 0.026 19 Vault Ceiling: Cathedral Ceiling 1,149 49.0 0.0 0.022 25 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.5.0 and to comply with the mandatory requiremen listed in the REScheck Inspection Checklist. n G‘vytc“-) _ .;_r-tzs- cx... , s/Lcrik4 Nam - itle Signat re 'm Date Project Title: Nugget Lane.Duplex-Side B Report date: 08/06/14 Data filename: P:\Team Folders\WD My Book\AE\AE Inc\Jobs\AE Projects\10479C Nugget Page 2 of 2 Residence\Nugget Side B.rck