HomeMy WebLinkAboutB14-0429_SOILS REPORT_1413999480.pdfSOIL AND FOUNDATION INVESTIGATION
FOR
PROPOSED RESIDENCE
LOT 1, BLOCK 1, VAIL VALLEY 1st FILING
1183 CABIN CIRCLE
TOWN OF VAIL
EAGLE COUNTY, COLORADO
PROJECT NO. 14-2968
OCTOBER 1, 2014
PREPARED FOR:
MR. SCOTT S. TURNIPSEED AIA
P.O. BOX 3388
EAGLE, COLORADO 81631
P.O. Box 2837, Edwards, CO 81632 Tel (970) 926-9088, www.lkpengineering.com
TABLE OF CONTENTS
EXECUTIVE SUMMARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SCOPE OF STUDY.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SITE DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PROPOSED CONSTRUCTION.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FIELD INVESTIGATION.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SUBSURFACE SOIL AND GROUNDWATER CONDITION.. . . . . . . . . . . . . . . . . . . . . . . . . 3
FOUNDATION RECOMMENDATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SLAB CONSTRUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
RETAINING WALLS.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
UNDERDRAIN SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SITE GRADING AND DRAINAGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LAWN IRRIGATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
LIMITATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
FIGURES
LOCATION SKETCH . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . .DRAWING NO. 1
SUBSURFACE EXPLORATION LOGS. . . . . . . . . . . . . . . . . . . . . . . . . . FIGURE NO’S 1-2
SWELL/CONSOLIDATION TEST RESULTS. . . . . . . . . . . . . . . . . . . . . . FIGURE NO’S 3-5
PERIMETER DRAIN . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . FIGURE NO. 6
P.O. Box 2837, Edwards, CO 81632 Tel (970) 926-9088, www.lkpengineering.com
2
EXECUTIVE SUMMARY
The proposed residence should be supported with
conventional type spread footings, designed for an
allowable soil bearing pressure of 1000 psf. They should
construct the footings on the undisturbed, silty sand.
SCOPE OF STUDY
This report presents the results of a subsurface Soil and Foundation Investigation for a
proposed residence to be constructed on Lot 1, Block 1, Vail Valley, 1st Filing, 1183 Cabin
Circle, Town of Vail, Eagle County, Colorado. The purpose of the subsurface soil and
foundation investigation was to determine the engineering characteristics of the foundation soil
and to provide recommendations for the foundation design, grading, and drainage. Geologic
Hazard studies are outside of our scope of services.
SITE DESCRIPTION
Lot 1 is a 0.72-acres lot, at 1183 Cabin Circle, Town of Vail, Eagle County, Colorado.
The topography is moderate for about the south 120 feet and then steep to the north, toward the
Vail Golf Course. Drainage is to the north, northwest, and east. Vegetation on the lot consisted
of landscaped grass, wild grass, pine and aspen trees. The lot has an existing two-story residence
LKP Engineering, Inc.
3
with a walkout basement that will be torn down. To the southeast and west of the lot are existing
residences.
PROPOSED CONSTRUCTION
The proposed residence will consist of two to three stories, wood frame construction, on
a concrete foundation, with a basement, stepping into the lot. Loads are anticipated to be light,
typical of residential construction.
If the finalized plans differ significantly from the above understanding, they should notify
us to reevaluate the recommendations of this report.
FIELD INVESTIGATION
The field investigation conducted on September 24, 2014, consisted of drilling, logging
and sampling two test bores. The test bore locations are shown on Drawing No. 1. Drilling of the
test borings was done with a 4-inch diameter, a continuous flight power auger on a truck
mounted, drill rig. Soil samples for laboratory soil analysis and observation were taken at
selected intervals with a California and Split Spoon Samplers, advanced with a 140-pound
hammer, falling 30 inches. We show the soil profiles of the test borings on the Subsurface
Exploration Logs, Figure No’s one and two. Soil samples for laboratory soil analysis and
observation were taken at selected intervals.
SUBSURFACE SOIL AND GROUNDWATER CONDITION
The soil profiles encountered in the test borings were somewhat uniform. Test Boring
No. 1 had about one foot of topsoil over light brown sandy gravel to gravelly sand with scattered
LKP Engineering, Inc.
4
cobbles and boulders to about 5 feet, underlain by reddish brown silty sand to the maximum
depth explored of 20 feet. Test Boring No. 2 had about one foot of topsoil over light to reddish
brown, gravelly sand with scattered cobbles to the maximum depth explored of 20 feet. Ground
water was not encountered.
Geologic hazard studies are outside of our scope of services.
FOUNDATION RECOMMENDATIONS
The proposed residence should be supported with conventional type spread footings,
designed for a maximum allowable soil bearing pressure of 1000 psf. The footings, for the entire
foundation, should be placed on the undisturbed, silty sand to gravelly sand with scattered
cobbles. Ground water was not encountered in either boring.
We recommend minimum width of 16 inches for the continuous footings and 2 feet for
the isolated footing pads. Continuous foundation walls should be reinforced top and bottom to
span an unsupported length of at least 10 feet.
A minimum of 48 inches of backfill cover is recommended for frost protection of the
footing subsoils. The undersigned engineer should observe the foundation excavation to verify
that the soil conditions are uniform throughout the foundation excavation or to provide
additional recommendations as necessary.
The foundation excavation should be free from excavation spoils, frost, organics and
standing water. The on-site soil free from topsoil, organics, and rock fragments smaller than six
inches, is suitable backfill material. Imported fill material, approved by the undersigned
engineer, might be necessary for the foundation backfill. Voids left in the excavation, due to rock
removal, should be filled with lean concrete. Footings should be constructed on a level surface.
LKP Engineering, Inc.
5
SLAB CONSTRUCTION
The natural on-site soils, exclusive of topsoil, organics, are suitable to support lightly
loaded slab-on-grade construction. The subgrade for the slab-on-grade construction should be
proof compacted to detect and remove soft spots. They should backfill overexcavated soft spots
and other underslab fill with the on-site soil, free from topsoil and organics, or other suitable
material, compacted to a minimum of 95 percent of the maximum standard Proctor density
(ASTM D-698). Suitable material should be free from topsoil, organics and rock fragments
greater than 3 inches.
The concrete slab should be constructed over a 4-inch layer of clean gravel consisting of -
3/4 inch gravel with at least 50% retained on the No. 4 sieve and less than 3 percent passing the
No. 200 sieve.
They should reinforce the concrete slab-on-grade and score control joints according to the
American Concrete Institute requirements and per the recommendations of the designer to reduce
damage due to shrinkage. The concrete slab should be separated from the foundation walls and
columns with expansion joints to allow for independent movement without causing damage.
RETAINING WALLS
They should design foundation walls retaining earth and retaining structures that are
laterally supported to resist an equivalent fluid density of 60 pcf for an “at-rest” condition.
Laterally unrestrained structures retaining the on-site earth should be designed to resist an
equivalent fluid density of 40 pcf for the “active” case. Passive earth pressure of 350 psf can be
used for the lateral pressure against the sides of the footings. Resistance to sliding at the bottom
of the footings can be calculated based on a coefficient of friction of 0.5. Undisturbed soil or a
structural fill compacted to 100 percent of the maximum dry density and within 2 percent of the
optimum moisture content will be used to resist lateral loads at the sides of the footings.
LKP Engineering, Inc.
6
The above design recommendations assume drained backfill conditions and a horizontal
backfill surface. Surcharge loading due to adjacent structures, weight of temporary stored
construction materials and equipment, inclined backfill and hydrostatic pressure due to
undrained backfill should be incorporated in the design. They should try to prevent the buildup
of hydrostatic pressure behind the retaining wall.
UNDERDRAIN SYSTEM
To reduce the risk of surface water infiltrating the foundation subsoil (and the
development of a perched water condition) installation of a foundation perimeter drain is highly
recommended. The foundation perimeter drain should consist of a 4-inch diameter perforated
pipe sloped to a suitable gravity outlet, or to a sump pump location. The drain should slope at 1/4
inch per foot if flexible or at 1/8 of an inch if rigid pipe is used. The bottom of the trench
adjacent to the footing should be lined with a polyethylene moisture barrier glued to the
foundation wall. The drain pipe should be placed over the moisture barrier and covered with a
minimum of 6 inches of -3/4 inch free-draining granular material. Geotextile (Mirafi 140N or
equivalent) should be used to cover the free-draining gravel to prevent siltation and clogging of
the drain. The backfill above the drain should be granular material to within 2 feet of the ground
surface to prevent a buildup of hydrostatic pressure. The top one foot of the backfill material
should consist of a relatively impervious fill. The backfill should slope away from the building.
SITE GRADING AND DRAINAGE
The site surrounding the building structure should slope away from the building in all
directions. A minimum of 12 inches in the first 10 feet is recommended in unpaved areas, and
three inches in the first 10 feet in paved areas. The top of the granular foundation backfill
LKP Engineering, Inc.
7
should be covered with a minimum of 1 foot of relatively impervious fill to reduce the potential
of surface water infiltrating the foundation subsoils.
Surface water naturally draining toward the proposed building site or permanent cuts,
should be diverted around and away from it by means of drainage swales or other approved
methods. The roof drains and downspouts should extend and discharge beyond the limits of the
backfill. Exterior backfill should be compacted at or near the optimum moisture content to at
least 95% of the maximum standard Proctor density under pavement, sidewalk and patio areas
and to at least 90% of the maximum standard Proctor density under landscaped areas.
Mechanical methods of compaction should be used. Do not puddle the foundation excavation.
Permanent, unretained cut and fill slopes should be graded at two horizontal to one
vertical or flatter with slope heights not exceeding 10 feet. Slopes exceeding 10 feet should have
benching incorporated. To protect the newly created slopes, erosion control methods should be
used. If water seepage is encountered during the slope construction, additional studies will be
required to evaluate the slope stability.
LAWN IRRIGATION
It is not recommended to introduce excess water to the foundation soils by installing
sprinkler systems next to the building. The installation of the sprinkler heads should insure that
the spray from the heads will not fall within 10 feet of foundation walls, porches or patio slabs.
Lawn irrigation must be controlled.
LIMITATION
This report has been prepared according to locally accepted Professional Geotechnical
Engineering standards for similar methods of testing and soil conditions at this time. There is no
LKP Engineering, Inc.
8
other warranty either expressed or implied.
The findings and recommendations of this report are based on field exploration,
laboratory testing of samples obtained at the specific locations shown on the Location Sketch,
Drawing No.1 and on assumptions stated in the report. Soil conditions at other locations may
vary, which may not become evident until the foundation excavation is completed. If soil or
water conditions seem different from those described in this report we should be contacted
immediately to reevaluate the recommendations of this report.
This report has been prepared for the exclusive use of Scott S. Turnipseed, AIA, for the
specific application to the proposed residence on Lot 1, Block 1, Vail Valley, 1st Filing, 1183
Cabin Circle, Town of Vail, Eagle County, Colorado.
Sincerely,
LKP ENGINEERING, INC.
________________________
Luiza Petrovska, PE
President
\\SERVER\Shared\_WP X4-LKP\_2014\14-2968sltgrsnd-bor.RPT.wpd
LKP Engineering, Inc.