Loading...
HomeMy WebLinkAboutB15-0020_ELoadEast_1423770600.pdf* A Service Charge of 1.5% per month will apply if not paid within 30 days of invoice, but not to exceed the highest amount lawfully allowed by law, will be made on all past due accounts. ** In the event Danici Electric, Inc. commences a Mechanics Lien and/or employs attorneys to collect payment of any amounts due, owner and/or contractor agree to pay reasonable filing and attorney’s fees. Danici Electric, Inc. PO Box 7246 ~ Breckenridge, CO 80424 Phone (970) 390-1173 ~ Fax (970) 547-9221 sparky63@danicielectric.com February 10, 2015 Attn: Dave Dantas D.W. Dantas Construction RE: Duplex at Snowberry—East Unit The Following are Load Calculations for 2755 Snowberry Dr., Lot 10, West Vail, CO 81657 (3,349 sf): General Lighting 11,000VA Small Appliance 3,000VA Laundry 1,500VA TOTAL 15,500VA 3,000VA at 100% 3,000VA 12,500VA at 35% 4,375VA NET LOAD 7,375VA Range 8,000VA Dryer Load 5,000VA Hot Tub 8,000VA Dishwasher 1,500VA Steamer 8,000VA Jetted Tub 1,800VA Heat Tape 2,000VA NET CALCULATED LOAD 41,675VA 41,675VA / 240V = 174A 174A TOTAL LOAD CALC 200A Service is Required Sincerely, David Novak Danici Electric, Inc.