February 10, 2015
Attn: Dave Dantas
D.W. Dantas Construction
RE: Duplex at Snowberry—East Unit
The Following are Load Calculations for 2755 Snowberry Dr., Lot 10, West Vail, CO 81657 (3,349 sf):
General Lighting 11,000VA
Small Appliance 3,000VA
Laundry 1,500VA
TOTAL 15,500VA
3,000VA at 100% 3,000VA
12,500VA at 35% 4,375VA
NET LOAD 7,375VA
Range 8,000VA
Dryer Load 5,000VA
Hot Tub 8,000VA
Dishwasher 1,500VA
Steamer 8,000VA
Jetted Tub 1,800VA
Heat Tape 2,000VA
NET CALCULATED LOAD 41,675VA
41,675VA / 240V = 174A
174A TOTAL LOAD CALC
200A Service is Required
Sincerely,
David Novak
Danici Electric, Inc.