Loading...
HomeMy WebLinkAboutB15-0021_A5-1_1429894500.pdfR-15 (MIN) BLOWN-IN INSULATION TO FILL 2X STUD FURRING WALL CAVITY. GYPSUM WALL BOARD HELD UP FROM SLAB 3/8" TREATED WOOD BOTTOM PLATE SEALANT UNDER PLATE FOR CAPILLARY BREAK. (R-10) UNDER-SLAB INSULATION HEATED CONCRETE SLAB (IN-FLOOR RADIANT HEATING SYSTEM) GRANULAR FILL - INCLUDE SOIL-GAS VENTILATION SYSTEM REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION/FOOTING DESIGN AND REINFORCEMENT (R-7) 3/4" RIGID INSULATION FOR THERMAL BREAK SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT COARSE GRANULAR FILL FILTER FABRIC DAMPROOFING OR W.P. MEMBRANE FOR CAPILLARY BREAK FREE-DRAINING BACKFILL (R-10) 2-3/8" DRAIN & DRY" DRAINAGE BOARD OVER WATERPROOFING (FROM FOOTING TO 8" BELOW FINISHED GRADE) 5/8" TYPE "X" GYPSUM WALL BOARD SLOPED 4" SOLID DRAIN FROM GUTTER & DOWNSPOUT UNDER- DRAIN SYSTEM. ALTERNATE SYSTEM: COMPOSITE DRAINAGE BOARD WITH FILTER FABRIC EXTEND FROM 8" BELOW GRADE TO FOOTING OVER 2" RIGID INLSULATION (TO A DEPTH OF 4'- 0" BELOW GRADE) OVER WATERPROOFING. INTERIOR SPACE BASE TRIM 1/2" AIRSPACE ADDITIONAL 4" PERFORATED DRAIN PIPE AT 10'-0" VERTICAL SPACING AT ALL UPHILL FOUNDATION WALLS IN EXCESS OF 15' IN HT 7 1/4" 2x8 AND 1x10 WOOD FASCIA (MILL FINISH) ON 8:12 PITCH ROOF FORMS (TYP) SEMI-TRANS STAIN COLOR #1 'D' SHAPED EAVE FLASHING WITH 1" OVER HANG 50-YEAR ASPHALT SHINGLE ON WATERPROOF MEMBRANE ON PLYWOOD SHEATHING ON PRE-ENGINEERED ROOF TRUSSES WITH R-60+ (18") BLOW-IN INSULATION ALONG BOTTOM CHORD OF TRUSS. CONTINUOUS SOFFIT VENT WITH BUG SCREEN 1x6 T&G WOOD SOFFIT (MILL FINISH) SEMI-TRANS STAIN COLOR #1 WOOD SIDING WITH SHIP-LAPPED JOINTS. (ROUGH SAWN SURFACE) ON THERMAL AND AIR INFILTRATION BARRIER ON SHEATHING ON 2x6 WOOD STUDS. PROVIDE R-23 BIBS INSULATION IN ALL EXTERIOR WALLS. . SCAB TO ROOF TRUSSES TO PROVIDE EAVE DIMENSION PROVIDE ATTIC SPACE VENTILATION AIR BAFFLE ABOVE WALL TO HOLD INSULATION FROM BOTTOM OF SHEATHING SEE BUILDING SECTIONS 1'-2" OR GREATER SEE ROOF PLAN B1.0 Lower Floor 'W' 8025' - 6" A2.5 Main Level 'E' 8041' - 0" A1.5 Lower Level 'E' 8029' - 0" A3.5 Upper Level 'E' 8053' - 0" A3.9 Garage Lvl 'E' 8055' - 6" GA FILE NO. WP 3810 BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT 24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4" HEADS, 16" O.C. FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT ANGLES TO STUDS OVER BASE LAYER AND TOP AND BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG, 0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4" HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE TAPED. SECOND WALL DUPLICATED OF FIRST WALL AND SEPARATED BY 1 1/4" SPACE. WALLS ARE INDEPENDANTLY LOADED. WALLS TO RECIEVE 5 1/2" BLOWN-IN INSULATION. (LOAD BEARING) EXTERIOR 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SOFFIT AND COVERED WITH 1x6 WOOD T&G SOFFIT MATERIAL 18" OF BLOWN-IN BATT AT THE BTM CHORD OF TRUSSES (R-64.8) VENTED TRUSS ATTIC SPACE VENTS ARE LOCATED AT ALL SOFFITS AND RIDGES WOOD FASCIA (MILL FINISH) SEMI-TRANS STAIN RAKE LADDER FRAMING STRUCTURE THICKNESS TO BE 7 1/4" GARAGE E-311 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SHEATHING FOR A DISTANCE OF 4'-0" FROM PARTY WALL WATERPROOF MEMBRANE FROM ROOF TO RUN UP WALL 24" MIN. STEP FLASHING AND COUNTER FLASHING. SIDING TO BE KEPT OFF ROOF SURFACE BY 4" GA FILE NO. 5752 2 HOUR FIRE RATED ASSEMBLY MUD E-308 HIS E-211 BEDROOM 3 E-106 GARAGE W-210 12' - 0" 12' - 0" 3" 2' - 3" 1 RC6 1 A3.2 1/2" 7 1/4" 3" HEEL HT 1' - 0 1/8" 8047' - 1 3/4" 7 1/4" 2'-6" OVERHANG 8046' - 3 1/2" PROVIDE ATTIC SPACE VENTILATION AIR BAFFLE ABOVE WALL TO HOLD INSULATION FROM BOTTOM OF SHEATHING 2x10 WOOD FASCIA (MILL FINISH) ON 4:12 PITCH ROOF FORMS (TYP) SEMI-TRANS STAIN 'D' SHAPED EAVE FLASHING WITH 1" OVER HANG 50-YEAR ASPHALT SHINGLE ON WATERPROOF MEMBRANE ON PLYWOOD SHEATHING ON PRE- ENGINEERED ROOF TRUSSES WITH R-60+ (18") BLOW-IN INSULATION ALONG BOTTOM CHORD OF TRUSS. CONTINUOUS SOFFIT VENT WITH BUG SCREEN 6x8 TIMBER KNEE BRACES AT ALL SHED DORMERS. PRE-ENGINEERED ROOF TRUSSES 1x6 T&G WOOD SOFFIT (MILL FINISH) SEMI-TRANS STAIN 6x6 APPLIED PURLINS (MILL FINISH) SEMI-TRANS STAIN COLOR #1 SISTER ON 2x8 TO TRUSS EAVE MEMBER TO ACHIEVE EAVE THICKNESS 9 1/2" 5 1/2" 2" 5 1/2" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date Consultant Address Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail REVISIONS2/9/2015 8:41:01 PM A5.1 Details/Schedules 1455 Snowberry Lot 10 PERMIT SET 02.09.15 Mountain C.I. Holdings Lot 10, Block 9, Vail Intermountain 2755 Snowberry Drive, West Vail, CO 81657 1" = 1'-0" 1 TYPICAL FOUNDATION DETAIL No. Description Date 1" = 1'-0" 2 TYPICAL EAVE 3/4" = 1'-0" 3 PARTYWALL DETAIL 1" = 1'-0" 4 MASTER BATH EAVE WEST UNIT Door Schedule Door Number Door Size Description Level E101 3_Panel_Sliding_Door_2276 SLIIDING GLASS PATIO DR A1.5 Lower Level 'E' E102P 34" x 84" A1.5 Lower Level 'E' E103 30" x 84" A1.5 Lower Level 'E' E104 30" x 84" A1.5 Lower Level 'E' E105 30" x 84" A1.5 Lower Level 'E' E106 34" x 84" E107A 30" x 84" A1.5 Lower Level 'E' E107B 30" x 84" A1.5 Lower Level 'E' E108 30" x 84" A1.5 Lower Level 'E' E200 96" x96" SLIIDING GLASS PATIO DR A2.5 Main Level 'E' E201 34" x 84" B2.0 Main Floor 'W' E202 34" x 84" B2.0 Main Floor 'W' E206 30" x 84" A2.5 Main Level 'E' E207 30" x 84" A2.5 Main Level 'E' E209 34" x 84" A2.5 Main Level 'E' E211 30" x 84" A2.5 Main Level 'E' E212 30" x 84" A2.5 Main Level 'E' E213 30" x 84" A2.5 Main Level 'E' E214 30" x 84" E300 42" x 96" entry door 2 B3.0 Upper Level 'W' E301 48" x 84" B3.0 Upper Level 'W' E302 34" x 84" A3.5 Upper Level 'E' E303 60" x 84" A3.5 Upper Level 'E' E304 34" x 84" A3.5 Upper Level 'E' E305 48" x 84" A3.5 Upper Level 'E' E306A 30" x 84" A3.5 Upper Level 'E' E306B 30" x 84" A3.5 Upper Level 'E' E310 36" x 84" A3.9 Garage Lvl 'E' E311 8-0 X 18-0 A3.9 Garage Lvl 'E' W101 3_Panel_Sliding_Door_2276 SLIIDING GLASS PATIO DR B1.0 Lower Floor 'W' W102 34" x 84" B1.0 Lower Floor 'W' W103 34" x 84" B1.0 Lower Floor 'W' W104 30" x 84" B1.0 Lower Floor 'W' W105 30" x 84" B1.0 Lower Floor 'W' W106 30" x 84" B1.0 Lower Floor 'W' W107 34" x 84" B1.0 Lower Floor 'W' W108 34" x 84" B1.0 Lower Floor 'W' W109 30" x 84" B1.0 Lower Floor 'W' W110 30" x 84" B1.0 Lower Floor 'W' W111 34" x 84" B1.0 Lower Floor 'W' W112 54" x 84" B1.0 Lower Floor 'W' W113A 30" x 84" B1.0 Lower Floor 'W' W113B 30" x 84" B1.0 Lower Floor 'W' W114A 36" x 96" GLASS PATIO DR B1.0 Lower Floor 'W' W114B 30" x 84" B1.0 Lower Floor 'W' W200 72" x 96" B2.0 Main Floor 'W' W201 34" x 96" B2.0 Main Floor 'W' W202 48" x 84" B2.0 Main Floor 'W' W207 30" x 84" B2.0 Main Floor 'W' W208 4884-Sliding BARN DOOR HARDWARE B2.0 Main Floor 'W' W209 32" x 84" B2.0 Main Floor 'W' W210A 36" x 96" GLASS PATIO DR A2.5 Main Level 'E' W210B 8-0 X 18-0 A2.5 Main Level 'E' W211A 3_Panel_Sliding_Door_2276 SLIIDING GLASS PATIO DR B2.0 Main Floor 'W' W211B 34" x 84" B2.0 Main Floor 'W' W212 30" x 84" B2.0 Main Floor 'W' W213 30" x 84" B2.0 Main Floor 'W' W214 30" x 84" B2.0 Main Floor 'W' W215 30" x 84" B2.0 Main Floor 'W' W300 34" x 84" B3.0 Upper Level 'W' W301 60" x 84" B3.0 Upper Level 'W' W303 30" x 84" B3.0 Upper Level 'W' Grand total: 62 Window Schedule - EAST UNIT Mark Unit Dimension Lights High Lights Wide Width Height e1 3' - 0" 5' - 6" 1 1 e2 4' - 6" 5' - 6" e3 3' - 0" 5' - 6" 1 1 e4 4' - 0" 1' - 9" 1 2 e5 4' - 0" 1' - 9" 1 2 e6 4' - 0" 1' - 9" 1 2 e7 3' - 0" 5' - 6" 1 1 e8 4' - 6" 5' - 6" e9 3' - 0" 5' - 6" 1 1 e10 4' - 6" 5' - 6" e11 3' - 0" 5' - 6" 1 1 e12 2' - 6" 1' - 9" 1 2 e13 2' - 6" 5' - 0" 1 1 e14 5' - 0" 6' - 9" e15 2' - 6" 1' - 9" 1 2 e16 2' - 6" 5' - 0" 1 1 e17 4' - 0" 5' - 0" e18 3' - 0" 4' - 6" 1 1 e19 4' - 6" 4' - 6" e20 3' - 0" 6' - 0" e21 6' - 0" 6' - 0" e22 3' - 0" 6' - 0" e23 4' - 0" 6' - 0" e24 4' - 0" 6' - 6" e25 4' - 0" 1' - 9" 1 2 e26 4' - 0" 6' - 6" e27 4' - 0" 1' - 9" 1 2 e28 4' - 0" 6' - 6" e29 4' - 0" 2' - 0" 1 2 e30 4' - 0" 6' - 6" e31 4' - 0" 2' - 0" 1 2 e32 4' - 0" 6' - 6" e33 4' - 0" 2' - 0" 1 2 e34 3' - 0" 3' - 0" 2 2 e35 3' - 0" 3' - 0" 2 2 e36 3' - 0" 4' - 0" 2 2 e37 3' - 0" 3' - 0" 1 1 e38 3' - 0" 4' - 0" 2 2 e39 3' - 0" 3' - 0" 1 1 e40 3' - 0" 4' - 0" 2 2 e41 3' - 0" 3' - 0" 1 1 e42 3' - 0" 4' - 0" 2 2 e43 3' - 0" 3' - 0" 1 1 e44 3' - 0" 4' - 0" 2 2 e45 3' - 0" 3' - 0" 1 1 e46 2' - 0" 3' - 0" 1 1 e47 3' - 0" 4' - 6" 1 1 e48 3' - 0" 4' - 6" 1 1 e49 2' - 0" 3' - 0" 1 1 e50 3' - 0" 4' - 6" 1 1 e51 3' - 0" 4' - 6" 1 1 e52 3' - 0" 3' - 0" 1 1 e53 3' - 6" 3' - 0" 1 1 e54 3' - 0" 3' - 0" 1 1 e55 3' - 0" 5' - 6" e56 3' - 0" 2' - 0" e57 3' - 0" 5' - 6" e58 3' - 0" 2' - 0" e59 3' - 0" 4' - 0" 2 2 e60 3' - 0" 4' - 0" 2 2 e61 3' - 0" 4' - 0" 2 2 e62 3' - 0" 3' - 6" 2 2 e63 3' - 0" 3' - 6" 2 2 Grand total: 63 Window Schedule - WEST UNIT Mark Unit Dimension Lights High Lights Wide Width Height w1 4' - 6" 5' - 6" w2 3' - 0" 5' - 6" 1 1 w3 3' - 0" 5' - 6" 1 1 w4 4' - 6" 5' - 6" w5 3' - 0" 5' - 0" 1 1 w6 3' - 0" 5' - 0" 1 1 w7 4' - 0" 1' - 9" 1 2 w8 4' - 0" 1' - 9" 1 2 w9 4' - 0" 1' - 9" 1 2 w10 3' - 0" 5' - 6" 1 1 w11 4' - 0" 5' - 6" w12 3' - 0" 5' - 6" 1 1 w13 3' - 0" 5' - 0" 1 1 w14 3' - 0" 4' - 6" 1 1 w15 2' - 0" 2' - 0" 2 2 w16 2' - 0" 2' - 0" 2 2 w17 2' - 0" 2' - 0" 2 2 w18 4' - 6" 5' - 6" w19 2' - 6" 5' - 6" 1 1 w20 7' - 0" 7' - 7" w21 3' - 0" 2' - 6" 1 1 w22 4' - 0" 1' - 9" 1 2 w23 4' - 0" 1' - 9" 1 2 w24 4' - 0" 1' - 9" 1 2 w25 4' - 0" 2' - 0" 1 2 w26 4' - 0" 5' - 10" 1 1 w27 4' - 0" 2' - 0" 1 2 w28 4' - 0" 2' - 0" 1 2 w29 4' - 0" 5' - 10" 1 1 w30 4' - 0" 2' - 0" 1 2 w31 6' - 0" 7' - 6" w32 3' - 0" 2' - 0" 1 1 w33 3' - 0" 2' - 0" 1 1 w34 4' - 0" 2' - 0" 1 2 w35 4' - 0" 5' - 10" 1 1 w36 4' - 0" 2' - 0" 1 2 w37 4' - 0" 2' - 0" 1 2 w38 4' - 0" 5' - 10" 1 1 w39 4' - 0" 2' - 0" 1 2 w40 3' - 0" 4' - 6" 1 1 w41 5' - 0" 4' - 6" w42 2' - 0" 2' - 0" 1 1 w44 3' - 0" 3' - 6" 0 0 w46 3' - 0" 3' - 6" 0 0 w47 3' - 0" 3' - 6" 0 0 w48 3' - 0" 3' - 6" 2 2 w49 3' - 0" 3' - 6" 0 0 w50 3' - 0" 3' - 6" 2 2 w51 3' - 0" 3' - 6" 2 2 w52 3' - 0" 3' - 6" 0 0 w53 3' - 0" 3' - 6" 0 0 w54 3' - 0" 3' - 6" 2 2 w55 3' - 0" 3' - 6" 0 0 w56 3' - 0" 3' - 6" 2 2 w57 1' - 4" 7' - 0" w58 3' - 0" 3' - 0" 1 1 w59 3' - 0" 4' - 6" 1 1 w60 3' - 0" 4' - 6" 1 1 Grand total: 58 1" = 1'-0" 5 TYPICALWINDOW TRIM WITHIN WOOD SIDING RESCHECK NOTES: TOTAL WINDOW AREA = SEE SHT A0.1 = 1,689.75 SF ALL WINDOWS USE PELLA (OR EQUAL) CATALOG VALUES: U-FACTOR = .32, SHGC = .26. THE WINDOW SPECIFIER MUST MEET OR EXCEED THESE VALUES, AND THESE VALUES MUST BE LOCATED ON THE CONSTRUCTION STICKER OF THE WINDOW. RESCHECK NOTES: EXTERIOR DOORS SOLID (W201, E300) AREA = 40 SF EXTERIOR DOORS FULL GLAZING (W101, W114A, W200, W211A) WEST AREA = 360 SF EXTERIOR DOORS FULL GLAZING (E101, E200) EAST AREA = 160 SF SOLID DOORS USE DEFAULT DOOR U-FACTOR FOR WOOD DOORS: U FACTOR = .5 GLAZED DOORS USE PELLA (OR EQUAL) CATALOG VALUES: U FACTOR .32 AND SHGC .23. 04/24/15