HomeMy WebLinkAboutB15-0021_stamped truss designs_1428592380.PDFRe:
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI 1.
The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision
based on the parameters provided by
Ong, Choo Soon
DW Dantas/Snowberry/#03047-15
Pages or sheets covered by this seal: R44203170 thru R44203218
My license renewal date for the state of Colorado is
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
October 31, 2015.
Alpine Truss-Montrose, CO.
03047-15
7777 Greenback Lane
Suite 109
Citrus Heights, CA, 95610
Telephone 916/676-1900
Fax 916/676-1909
MiTek USA, Inc.
April 8,2015
Job
03047-15
Truss
A1G
Truss Type
SCISSORS
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203170
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:09 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-OZgTj_ezZtP0IY8tglP6WKfkDzbK4qvTMQSv8nzSpDu
Scale = 1:43.9
1
2
3
4
5
8
7
6
5x10 M18SHS
6x6
5x10 M18SHS
6x8
4x6 4x6
4x8 MT18HS 4x8 MT18HS
8-3-0
8-3-0
16-6-0
8-3-0
4-3-4
4-3-4
8-3-0
3-11-12
12-2-12
3-11-12
16-6-0
4-3-4
1-5-16-11-11-5-12-11-18.00 12
4.50 12
Plate Offsets (X,Y)-- [3:0-3-4,0-3-0], [6:0-2-12,0-2-0], [7:0-4-0,0-3-4], [8:0-2-12,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.60
0.70
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.14
-0.21
0.21
0.01
(loc)
7
7-8
6
7
l/defl
>999
>946
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 83 lb FT = 0%
GRIP
169/123
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
4-7,2-7: 2x4 WW Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-8, 4-6
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)8=1945/0-5-8 (min. 0-2-12), 6=1945/0-5-8 (min. 0-2-12)
Max Horz 8=111(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-787/0, 2-3=-2982/0, 3-4=-2982/0, 4-5=-787/0, 1-8=-780/0, 5-6=-780/0
BOT CHORD 7-8=0/2641, 6-7=0/2641
WEBS 3-7=0/2007, 2-8=-2839/0, 4-6=-2839/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
B1
Truss Type
ROOF SPECIAL
Qty
3
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203171
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:25:15 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-o66rjc8DYbJWG9qvYvumDGEpZXkbcuvnOpcpOOzSkfI
Scale = 1:69.9
A
B
C
D
E
F
G
H
I
J X
M
K
L
W
V
U
T
S
R Q P
O N
Y
Z
10x10
8x8
3x8 M18SHS
8x10
5x5
4x6 5x6
12x18 M18SHS 8x16
5x8
3x8
4x6
3x4
3x4
10x10
8x12
6x8
4x6
3x6
9x10 M18SHS
4x10
4-3-8
4-3-8
8-3-0
3-11-8
12-2-0
3-11-0
16-0-8
3-10-8
18-5-8
2-5-0
20-10-8
2-5-0
24-8-8
3-10-0
28-6-8
3-10-0
30-7-8
2-1-0
33-0-0
2-4-8
-3-6-8
3-6-8
4-3-8
4-3-8
8-3-0
3-11-8
8-3-8
0-0-8
12-2-0
3-10-8
16-0-8
3-10-8
18-5-8
2-5-0
20-10-8
2-5-0
24-8-8
3-10-0
28-6-8
3-10-0
30-7-8
2-1-0
33-0-0
2-4-8
35-6-0
2-6-0
2-1-127-8-19-3-51-0-81-7-44-6-51-7-41-0-08.00 12
4.00 12
4.50 12
3.00 12
Plate Offsets (X,Y)-- [B:0-3-8,0-3-12], [D:0-7-11,0-4-0], [F:0-2-0,0-3-8], [G:0-2-14,0-1-12], [H:0-3-12,0-4-0], [M:0-3-10,0-3-3], [M:0-0-13,0-2-3], [O:0-8-8,0-6-0], [Q:0-5-0,0-4-0],
[S:0-5-4,0-7-4], [U:0-4-12,0-5-0], [V:0-2-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.85
0.75
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.54
-0.70
0.45
0.05
(loc)
N-O
N-O
K
O
l/defl
>725
>559
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 289 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
H-L: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
F-R: 2x4 SPF 1650F 1.5E, H-P: 1.5X5.5 Microllam LVL 2.0E TG
M-O,K-M: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
C-V,C-U,E-U,E-T,F-T,I-O,I-N: 2x4 WW Stud
OTHERS 1.5X7.25 Microllam LVL 2.0E TG
LBR SCAB J-L 1.5x7.25 MLLVL MicrollamTG both sides
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: V-W,R-S,K-M.
WEBS 1 Row at midpt G-Q, I-O
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)W=3179/0-5-8 (min. 0-4-10), K=2794/0-5-8 (min. 0-2-7)
Max Horz W=-104(LC 8)
Max Grav W=3241(LC 15), K=2879(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-Y=0/416, B-C=-3567/0, C-D=-4377/0, D-E=-3905/0, E-F=-4920/0, F-Z=-5268/0,
G-Z=-5333/0, G-H=-5477/0, H-I=-5904/0, I-J=-7598/0, J-X=-7642/0, M-X=-7698/0,
B-W=-3150/0
BOT CHORD V-W=-308/103, U-V=0/2915, T-U=0/4870, S-T=0/5269, P-Q=0/1447, N-O=0/7282,
M-N=0/7282, K-M=-1407/0
WEBS C-V=-1204/0, C-U=0/1074, E-U=-1196/43, E-T=-28/293, F-T=-586/33, Q-S=0/4867,
G-S=0/1858, G-Q=-4274/0, O-Q=0/2839, G-O=0/2608, I-O=-2040/0, I-N=0/393,
B-V=0/2884, D-U=0/3027
NOTES-
1) Attached 7-6-7 scab J to L, both face(s) 1.5X7.25 Microllam LVL 2.0E TG with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except
: starting at 0-0-0 from end at joint J, nail 3 row(s) at 4" o.c. for 2-0-0.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Bearing at joint(s) W, K considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.Continued on page 2
TRUSS WORK WITHOUT BC FILER
DESIGNS IN THIS JOB CHECKED FOR 1.0 TIMES OF THE SNOW LOAD ON OVERHANG PER SECTION 7.4.5 ASCE 7-10
THIS IS TO BE APPROVED BY LOCAL BUILDING DEPARTMENT.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
B1
Truss Type
ROOF SPECIAL
Qty
3
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203171
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:25:15 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-o66rjc8DYbJWG9qvYvumDGEpZXkbcuvnOpcpOOzSkfI
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
B1G
Truss Type
ROOF SPECIAL
Qty
1
Ply
4
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203172
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:26:07 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-H6FVdOmrJZs8V9pvbqpzKENjDVVVoRYRMvCZDNzSkeU
Scale = 1:68.3
A
B
C
D
E
F
G
H
I
L
J
K
V
U
T
S
R
Q P O
N M
W
X
8x8
6x8
3x8 M18SHS
8x8
5x5
4x4 4x6
12x20 8x16
5x8
3x6
5x6
3x4
3x4
8x10
5x10
5x8
4x6
3x6
8x8
4-3-8
4-3-8
8-3-0
3-11-8
12-2-0
3-11-0
16-0-8
3-10-8
18-5-8
2-5-0
20-10-8
2-5-0
24-8-8
3-10-0
28-6-8
3-10-0
30-7-8
2-1-0
33-0-0
2-4-8
-3-6-8
3-6-8
4-3-8
4-3-8
8-3-0
3-11-8
8-3-8
0-0-8
12-2-0
3-10-8
16-0-8
3-10-8
18-5-8
2-5-0
20-10-8
2-5-0
24-8-8
3-10-0
28-6-8
3-10-0
30-7-8
2-1-0
33-0-0
2-4-8
35-6-0
2-6-0
2-1-127-8-19-3-51-0-81-7-44-6-51-7-41-0-08.00 12
4.00 12
4.50 12
3.00 12
Plate Offsets (X,Y)-- [B:0-3-8,0-3-12], [D:0-4-11,0-2-12], [F:0-2-4,0-3-8], [G:0-2-10,0-1-12], [H:0-3-8,0-3-0], [L:1-3-3,0-5-5], [L:0-4-10,0-3-3], [P:0-4-0,0-1-8], [R:0-6-4,0-5-4],
[T:0-2-12,0-4-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
4-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.73
0.70
0.80
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.42
-0.54
0.35
0.04
(loc)
M-N
M-N
J
N
l/defl
>942
>726
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 986 lb FT = 0%
GRIP
118/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
H-K: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
F-Q: 2x4 SPF 1650F 1.5E, H-O: 1.5X5.5 Microllam LVL 2.0E TG
L-N,J-L: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
C-U,C-T,E-T,E-S,F-S,I-N,I-M: 2x4 WW Stud
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: U-V,Q-R,J-L.
REACTIONS.(lb/size)V=9537/0-5-8 (min. 0-3-7), J=8381/0-5-8 (min. 0-1-13)
Max Horz V=-311(LC 8)
Max Grav V=9723(LC 15), J=8638(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-W=0/465, B-W=0/1249, B-C=-10701/0, C-D=-13131/0, D-E=-11714/0, E-F=-14759/0,
F-X=-15803/0, G-X=-15997/0, G-H=-16427/0, H-I=-17681/0, I-L=-23286/0, B-V=-9450/0
BOT CHORD U-V=-925/308, T-U=0/8744, S-T=0/14609, R-S=0/15809, F-R=-344/250, P-Q=0/712,
O-P=0/4419, H-N=-789/73, M-N=0/21948, L-M=0/21948, J-L=-4221/0
WEBS C-U=-3613/0, C-T=0/3223, E-T=-3589/129, E-S=-83/879, F-S=-1760/100, P-R=0/14599,
G-R=0/5578, G-P=-12785/0, N-P=0/8429, G-N=0/7803, I-N=-6243/0, I-M=0/1618,
B-U=0/8651, D-T=0/9081
NOTES-
1) 4-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 1.5x7.25 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0
oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc, 1.5x7.25 - 2 rows staggered at
0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
Attach TC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.Continued on page 2
Alternate to 1/2" dia Bolts & Washers specified in note 1:USP W6, SIMPSON SDS25600, SDW22638 OR TRUSSLOK TSLZ006,
1/4" X 6" WOOD SCREWS SPACED @ 24" O.C., 2 ROWS (ONE ROW - 2X4)
DRIVEN FROM LOADED SIDE OF 4-PLY GIRDER TRUSS CAN
REPLACE THE 1/2" BOLTS @ 48" O.C. IN CHORD MEMBERS AS SHOWN IN THE NOTE SECTION.
5x8
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
B1G
Truss Type
ROOF SPECIAL
Qty
1
Ply
4
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203172
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:26:07 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-H6FVdOmrJZs8V9pvbqpzKENjDVVVoRYRMvCZDNzSkeU
NOTES-
10) Bearing at joint(s) V, J considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
B2
Truss Type
ROOF SPECIAL
Qty
4
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203173
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:14 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-lXUMmhi5OQ1JOJ1qTI?HDOMZv_HXl?4CWiAgp_zSpDp
Scale = 1:72.8
1
2
3
4
5
6
7
8
9
10
11
19
18
17
16
15
14 13 12
20
21
10x12 M18SHS
8x8
4x8 MT18HS
10x12 M18SHS
6x6
6x8
8x12
6x12 MT18HS
4x6
5x8
4x4
3x4
12x14 M18SHS
8x12
4x6
2x4
9x10 M18SHS
4-3-8
4-3-8
8-3-0
3-11-8
13-1-8
4-10-8
17-11-8
4-10-0
22-10-8
4-11-0
27-9-8
4-11-0
33-0-0
5-2-8
-3-6-8
3-6-8
4-3-8
4-3-8
8-3-0
3-11-8
8-3-8
0-0-8
13-1-8
4-10-0
17-11-8
4-10-0
22-10-8
4-11-0
27-9-8
4-11-0
33-0-0
5-2-8
35-6-0
2-6-0
2-1-127-8-19-3-51-0-81-7-44-6-50-10-100-0-08.00 12
4.00 12
4.50 12
Plate Offsets (X,Y)-- [2:0-4-8,0-4-0], [4:0-3-1,Edge], [6:0-1-12,0-3-8], [7:0-2-12,0-4-12], [10:0-0-13,0-4-0], [13:0-5-4,0-4-0], [14:0-3-4,Edge], [15:0-8-12,0-7-0], [17:0-6-0,0-3-12],
[18:0-3-0,0-2-8], [19:0-0-0,0-0-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.67
0.83
0.80
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.49
-0.63
0.34
0.04
(loc)
15-16
15-16
10
15-16
l/defl
>804
>618
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 217 lb FT = 0%
GRIP
118/123
113/123
169/123
LUMBER-
TOP CHORD 2x8 SPF 1950F 1.7E *Except*
4-7: 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E *Except*
17-19: 2x4 SPF 1650F 1.5E, 6-14: 1.5X5.5 Microllam LVL 2.0E TG
WEBS 2x4 WW Stud *Except*
3-17,5-17,2-18,4-17: 2x4 SPF 1650F 1.5E, 13-15: 2x4 SPF 2100F 1.8E
2-19: 2x6 SPF 1650F 1.5E
SLIDER Right 2x4 WW Stud 2-7-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 18-19.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)19=4797/0-5-8 (req. 0-6-15), 10=4501/0-5-8 (req. 0-5-14)
Max Horz 19=-163(LC 8)
Max Grav 19=4884(LC 15), 10=4635(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-20=0/646, 2-3=-5160/0, 3-4=-6480/0, 4-5=-5900/0, 5-21=-7421/0, 6-21=-7641/0,
6-7=-7574/0, 7-8=-7513/0, 8-9=-7446/0, 9-10=-7687/0, 2-19=-4759/0
BOT CHORD 18-19=-428/177, 17-18=0/4132, 16-17=0/7494, 15-16=0/7627, 6-15=-1070/2,
13-14=0/1476, 12-13=0/6755, 10-12=0/6755
WEBS 3-18=-1756/0, 3-17=0/1804, 5-17=-1850/81, 13-15=0/5663, 7-13=-1318/24, 8-13=0/336,
2-18=0/4017, 4-17=0/4263
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) WARNING: Required bearing size at joint(s) 19, 10 greater than input bearing size.
9) Bearing at joint(s) 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
B3
Truss Type
Roof Special
Qty
2
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203174
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:15 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-Dj2kz1jk9j9A0Tc11?WWmbvlFObRURpMkMvELRzSpDo
Scale = 1:66.3
1
2
3
4
5
6
7
8
9
18 17 16 15 14
13
12 11 10
19
20
12x12
8x8
6x12 MT18HS
6x8
6x6
8x16
4x6
4x6 4x8
5x8
6x6
12x18 M18SHS
7x14
4x8
3x8
3x8
2x4
9x10 M18SHS
3x8
4-3-8
4-3-8
8-3-8
4-0-0
13-1-8
4-10-0
17-11-8
4-10-0
22-10-8
4-11-0
27-9-8
4-11-0
33-0-0
5-2-8
-3-6-8
3-6-8
4-3-8
4-3-8
8-3-8
4-0-0
13-1-8
4-10-0
17-11-8
4-10-0
22-10-8
4-11-0
27-9-8
4-11-0
33-0-0
5-2-8
2-1-127-8-19-3-51-0-81-7-48.00 12
4.00 12
Plate Offsets (X,Y)-- [2:0-4-8,0-3-12], [4:0-10-1,0-5-4], [6:0-2-12,0-3-8], [7:0-4-0,0-5-4], [8:0-1-0,0-1-12], [9:Edge,0-3-4], [11:0-6-4,0-4-0], [13:1-2-0,0-6-0], [14:0-2-12,0-3-0],
[16:0-1-12,0-1-8], [17:0-1-12,0-1-8], [18:0-3-12,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.63
0.85
0.83
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.53
-0.69
0.21
0.05
(loc)
13-14
13-14
9
13
l/defl
>737
>572
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 233 lb FT = 0%
GRIP
118/123
113/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
1-4: 2x8 SPF 1950F 1.7E
BOT CHORD 2x6 SPF 2100F 1.8E *Except*
13-15: 1.5X5.5 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
3-17,3-16,8-11,8-10: 2x4 WW Stud, 11-13,2-18: 2x6 SPF 1650F 1.5E
SLIDER Right 2x8 SPF 1950F 1.7E 5-4-7
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-7 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 17-18.
WEBS 1 Row at midpt 5-16, 6-14
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=3881/0-5-8 (min. 0-5-2), 18=4851/0-5-8 (min. 0-1-12)
Max Horz 18=-156(LC 8)
Max Grav 9=4014(LC 16), 18=4851(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-19=0/303, 2-19=0/596, 2-3=-3800/0, 3-4=-4008/0, 4-5=-3635/0, 5-20=-6103/0,
6-20=-6307/0, 6-7=-9247/0, 7-8=-7814/0, 8-9=-8570/0, 2-18=-4768/0
BOT CHORD 17-18=-491/159, 16-17=0/2766, 15-16=0/5790, 14-15=0/5790, 13-14=0/8753,
6-13=0/2114, 11-12=0/757, 10-11=0/7677, 9-10=0/7677
WEBS 3-17=-1186/7, 3-16=-64/973, 4-16=0/2204, 5-16=-3804/0, 5-14=0/2275, 6-14=-3740/0,
11-13=0/6981, 7-13=0/1451, 7-11=-2215/0, 8-11=-509/22, 2-17=0/3123
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 18 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C1
Truss Type
ROOF SPECIAL
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203175
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:17 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-959UOjk_hLQtFnmP8QY_r0_5DBJzyKIfCgOKQJzSpDm
Scale = 1:83.0
1
2
3
4
5
6 7
8
9
10
11
12
13
25
24
23
22
21
20 19 18 17
16
15 14
26 27
28
8x8 8x8
10x10
6x8
5x6 5x8
6x8
5x6
4x4
4x4
4x4
8x8
12x18 M18SHS
10x10
4x4
4x4
4x4
4x4
4x4
4x4
2x4
6x8
4x8
3-11-10
3-11-10
7-7-12
3-8-2
11-3-14
3-8-2
15-0-0
3-8-2
17-9-12
2-9-12
22-8-5
4-10-9
27-6-14
4-10-9
32-5-7
4-10-9
37-3-15
4-10-9
42-6-0
5-2-1
-3-0-0
3-0-0
3-11-10
3-11-10
7-7-12
3-8-2
11-3-14
3-8-2
15-0-0
3-8-2
17-9-12
2-9-12
22-8-5
4-10-9
27-6-14
4-10-9
32-5-7
4-10-9
37-3-15
4-10-9
42-6-0
5-2-1
1-2-127-2-09-3-41-0-82-1-45-8-145-8-144.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-4-8], [7:0-3-0,0-2-4], [10:0-4-0,0-4-8], [13:0-5-3,0-1-0], [19:0-3-0,0-2-8], [21:0-7-4,0-4-8], [25:0-4-12,0-7-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.60
0.71
0.89
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-1.00
-1.30
0.76
0.08
(loc)
20
20
13
20
l/defl
>506
>389
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 548 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
21-25,6-20: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
19-21,2-25: 2x6 SPF 1650F 1.5E, 7-21,7-19,2-24: 2x4 SPF 2100F 1.8E
SLIDER Right 2x4 WW Stud 2-8-2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 24-25.
WEBS 1 Row at midpt 7-19
REACTIONS.(lb/size)25=3885/0-5-8 (min. 0-2-6), 13=3363/0-5-8 (min. 0-2-11)
Max Horz 25=-58(LC 11)
Max Grav 25=3885(LC 1), 13=3462(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8902/0, 3-26=-13711/0, 4-26=-13709/0, 4-5=-15589/0, 5-6=-15199/0,
6-7=-14089/0, 7-8=-4260/0, 8-9=-5425/0, 9-27=-6437/0, 10-27=-6571/0, 10-11=-7321/0,
11-12=-7103/0, 12-13=-7281/0, 2-25=-3757/0
BOT CHORD 24-25=-477/924, 23-24=0/8664, 22-23=0/13368, 21-22=0/15120, 20-21=0/251,
6-21=-33/660, 19-20=0/378, 19-28=0/5008, 18-28=0/5008, 17-18=0/6106, 16-17=0/6911,
15-16=0/6911, 14-15=0/6519, 13-14=0/6519
WEBS 3-24=-2113/0, 3-23=0/4602, 4-23=-1450/0, 4-22=0/2014, 5-22=-485/18, 5-21=-1230/440,
19-21=0/8651, 7-21=0/14777, 7-19=-6541/0, 8-19=-2365/0, 8-18=0/1296, 9-18=-1662/4,
9-17=0/713, 10-17=-1041/5, 11-15=0/458, 2-24=0/7296
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
10) Bearing at joint(s) 25 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C1
Truss Type
ROOF SPECIAL
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203175
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:17 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-959UOjk_hLQtFnmP8QY_r0_5DBJzyKIfCgOKQJzSpDm
NOTES-
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
C1G
Truss Type
GABLE
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203176
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:18 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-dIjsb3lcSeYktxKci84DNEXEvbb_hmaoQK8uymzSpDl
Scale = 1:64.9
3
4
5
6
7
8
1
2
16 15 14 13
12
11 10 9
8x8
8x10
5x10 M18SHS 9x10 M18SHS
8x8
4x6
10x18
4x6
5x8 6x8
5x6
12x18 M18SHS
12x14 M18SHS
5x8
4x8
2x4
9x10 M18SHS
2x4
2x4
2x4
2x4
2x4
3x6
2x4
3x6
2x4
3x6
2x4
2x4
5-3-10
5-3-10
10-3-12
5-0-2
15-1-10
4-9-14
19-11-8
4-9-14
24-10-8
4-11-0
29-9-8
4-11-0
35-0-0
5-2-8
5-3-10
5-3-10
10-3-12
5-0-2
15-1-10
4-9-14
19-11-8
4-9-14
24-10-8
4-11-0
29-9-8
4-11-0
35-0-0
5-2-8
3-7-28-11-71-0-81-7-44.00 12
Plate Offsets (X,Y)-- [4:0-2-4,0-2-4], [6:0-5-0,0-4-8], [7:0-1-4,0-2-4], [8:Edge,0-3-8], [10:0-6-12,Edge], [12:0-11-12,0-6-0], [13:0-4-4,0-4-12], [15:0-2-12,0-2-4], [18:0-1-15,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.73
0.98
0.96
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.68
-0.89
0.33
0.07
(loc)
12
12-13
8
12
l/defl
>611
>469
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 226 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
1-3: 2x8 SPF 1950F 1.7E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
5-11: 2x4 SPF 1650F 1.5E, 8-11: 2x4 SPF 2100F 1.8E
12-13: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
10-12: 2x4 SPF 2100F 1.8E, 1-16: 2x6 SPF 1650F 1.5E
17-18,18-19: 2x4 WW Stud
OTHERS 2x4 WW Stud
SLIDER Right 2x6 SPF 1650F 1.5E 5-5-1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 4-14, 5-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=4173/0-5-8 (req. 0-6-9), 8=4173/0-5-8 (min. 0-5-5)
Max Horz 16=-95(LC 11)
Max Grav 16=4173(LC 1), 8=4182(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-5096/0, 4-5=-6935/0, 5-6=-10442/0, 6-7=-8076/0, 7-8=-8739/0, 1-16=-4060/0,
1-2=-4211/0, 2-3=-5166/0
BOT CHORD 14-15=0/3823, 13-14=0/6420, 12-13=0/9770, 5-12=0/2683, 10-11=0/303, 9-10=0/7779,
8-9=0/7779
WEBS 2-15=-2186/21, 2-14=0/1612, 3-14=0/2054, 4-14=-3510/0, 4-13=0/2299, 5-13=-4358/0,
10-12=0/7897, 6-12=0/2343, 6-10=-2840/0, 7-10=-257/71, 1-15=0/4222
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) All plates are MT20 plates unless otherwise indicated.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) WARNING: Required bearing size at joint(s) 16 greater than input bearing size.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C2
Truss Type
SCISSORS
Qty
4
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203177
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:19 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-5UHFpPmEDygbV4voGrbSwR3TS?zxQFsxf_tRUCzSpDk
Scale = 1:67.0
1
2
3
4
5
6 7
8
9
10
11
21
20
19
18
17 16
15
14
13
12
22
23
7x10
8x10
8x8
12x18 M18SHS
6x12 MT18HS
12x18 M18SHS
4x4
4x6
3x8
8x8
10x10
4x4
4x6
10x12 M18SHS
4x8
6x8
12x14 M18SHS 6x6
7x10
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
29-8-13
3-11-11
34-0-0
4-3-3
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
29-8-13
3-11-11
34-0-0
4-3-3
1-2-127-2-07-5-42-0-80-3-44-3-44.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-8,0-4-12], [6:0-3-12,0-4-0], [7:0-5-0,0-3-8], [9:0-4-0,0-5-0], [13:0-3-0,0-3-0], [14:0-5-8,0-5-0], [16:0-5-0,0-5-12], [17:0-8-12,0-7-0], [21:0-4-4,0-7-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.49
0.87
0.83
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.96
-1.25
0.76
0.09
(loc)
17-18
17-18
12
17-18
l/defl
>419
>321
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 227 lb FT = 0%
GRIP
118/123
113/123
113/123
LUMBER-
TOP CHORD 1.5X5.5 Microllam LVL 2.0E TG
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG *Except*
17-19,14-17: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
2-21: 1.5X5.5 Microllam LVL 2.0E TG, 2-20: 2x4 SPF 2100F 1.8E
11-12: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-9-4 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 20-21.
REACTIONS.(lb/size)21=3191/0-5-8 (min. 0-2-12), 12=2660/0-5-8 (min. 0-2-6)
Max Horz 21=33(LC 12)
Max Grav 21=3200(LC 15), 12=2785(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-7314/0, 3-22=-10901/0, 4-22=-10793/0, 4-5=-11533/0, 5-6=-9774/0, 6-7=-8035/0,
7-8=-8261/0, 8-9=-8100/0, 9-10=-7676/0, 10-23=-5015/0, 11-23=-5183/0, 2-21=-3146/0,
11-12=-2737/0
BOT CHORD 20-21=-465/902, 19-20=0/7081, 18-19=0/10534, 17-18=0/11139, 16-17=0/9137,
15-16=0/7879, 14-15=0/7386, 13-14=0/4966, 12-13=-2/431
WEBS 3-20=-1559/4, 3-19=0/3444, 4-19=-918/11, 4-18=0/1079, 5-18=-11/297, 5-17=-2342/7,
6-17=0/3734, 6-16=-3464/0, 7-16=0/3957, 8-16=-556/936, 8-15=-669/14, 9-15=0/913,
9-14=-1062/0, 10-14=0/2522, 10-13=-1967/0, 2-20=0/5829, 11-13=0/4419
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 21, 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C2GD
Truss Type
SCISSORS
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203178
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:26:48 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-a?E?EQGZf91JwSRnUx2aUtaqF0VFv?STnneE9VzSkdr
Scale = 1:65.9
A
B
C
D
E
F G
H
I
J
K
U
T
S
R
Q P
O
N
M
L
V W
8x8
8x8
8x8
12x18 M18SHS
6x8 10x12 M18SHS
4x4
4x6
3x4
8x8
10x10
3x4
8x8
7x12 M18SHS
4x8
5x10
10x10 5x5
8x8
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
29-8-13
3-11-11
34-0-0
4-3-3
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
29-8-13
3-11-11
34-0-0
4-3-3
1-2-127-2-07-5-42-0-80-3-44-3-44.00 12
3.00 12
Plate Offsets (X,Y)-- [C:0-3-12,0-4-12], [I:0-3-12,0-4-8], [N:0-4-12,0-4-8], [O:0-4-0,0-5-4], [P:0-5-0,0-5-12], [S:0-5-0,0-5-4], [T:0-4-0,0-2-12], [U:0-4-12,0-7-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.33
0.69
0.68
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.76
-0.99
0.61
0.07
(loc)
Q-R
Q-R
L
Q-R
l/defl
>529
>406
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 455 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 1.5X5.5 Microllam LVL 2.0E TG
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG *Except*
Q-S,N-Q: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
B-U: 1.5X5.5 Microllam LVL 2.0E TG, B-T: 2x4 SPF 2100F 1.8E
K-L: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-1-2 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: T-U.
REACTIONS.(lb/size)U=4085/0-5-8 (min. 0-1-12), L=4266/0-5-8 (min. 0-1-14)
Max Horz U=33(LC 12)
Max Grav U=4094(LC 15), L=4391(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-10237/0, C-V=-15787/0, D-V=-15680/0, D-E=-17644/0, E-F=-16149/0, F-G=-13718/0,
G-H=-14094/0, H-I=-15482/0, I-J=-13519/0, J-W=-8276/0, K-W=-8443/0, B-U=-4077/0,
K-L=-4324/0
BOT CHORD T-U=-379/1421, S-T=0/9954, R-S=0/15268, Q-R=0/17068, P-Q=0/15128, O-P=0/15158,
N-O=0/13047, M-N=0/8140, L-M=0/642
WEBS C-T=-2166/0, C-S=0/5302, D-S=-1449/4, D-R=0/2302, E-Q=-2112/10, F-Q=0/5512,
F-P=-4547/0, G-P=0/6935, H-P=-2111/46, H-O=0/1008, I-O=0/2485, I-N=-2125/0,
J-N=0/5067, J-M=-3280/0, B-T=0/8050, K-M=0/7306
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-9-0 oc, 1.5x7.25 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member H-O 2x4 - 2 rows staggered at 0-3-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Bearing at joint(s) U, L considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C2GD
Truss Type
SCISSORS
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203178
Run: 7.600 s Oct 3 2014 Print: 7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:26:48 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-a?E?EQGZf91JwSRnUx2aUtaqF0VFv?STnneE9VzSkdr
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2500 lb down at 21-8-4 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: A-B=-147, B-G=-147, G-K=-147, Q-U=-13, L-Q=-13
Concentrated Loads (lb)
Vert: O=-2500(F)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
C3
Truss Type
SCISSORS
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203179
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:22 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-W3zNRRo7Vt2AMYeNxz89Y4humC1ade3OLy655XzSpDh
Scale = 1:46.6
1
2
3
4
5
6 7
8
15
14
13
12
11 10 9
16
8x8
5x5
7x12 M18SHS
7x12 M18SHS
4x4
7x10
3x4
4x4
3x8
5x6
6x10
6x8
10x12 M18SHS
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-6-9
3-8-13
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-6-9
3-8-13
1-2-127-2-03-1-72-9-101-2-64.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-4-8], [6:0-2-0,0-1-12], [7:0-3-8,0-2-8], [8:0-4-0,0-3-8], [11:0-5-4,0-4-0], [13:0-5-12,0-4-8], [14:0-5-0,0-2-8], [15:0-5-0,0-7-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.87
0.69
0.67
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.46
-0.60
0.26
0.05
(loc)
12-13
12-13
9
13
l/defl
>553
>422
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 126 lb FT = 0%
GRIP
197/144
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-15: 1.5X5.5 Microllam LVL 2.0E TG, 2-14: 2x4 SPF 2100F 1.8E
8-9: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-4 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 14-15.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=2474/0-3-8 (min. 0-3-0), 15=3314/0-5-8 (min. 0-4-0)
Max Horz 15=117(LC 7)
Max Uplift15=-25(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6100/0, 3-4=-8093/0, 4-5=-7107/0, 5-16=-4163/0, 6-16=-4011/0, 6-7=-2624/0,
7-8=-2744/0, 2-15=-3123/44, 8-9=-2465/0
BOT CHORD 14-15=-899/332, 13-14=0/5845, 12-13=0/7791, 11-12=0/6793, 10-11=0/3853
WEBS 3-14=-1353/39, 3-13=0/1941, 4-13=-466/43, 4-12=-950/15, 5-12=0/615, 5-11=-2920/3,
6-11=0/2834, 6-10=-3249/0, 7-10=0/1226, 8-10=0/2706, 2-14=0/5205
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 9, 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 25 lb uplift at joint 15.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C4
Truss Type
SCISSORS
Qty
8
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203180
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:23 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-_FXlfmplGBA1ziDZVhfO4HE3WcIEM4lXacrfdzzSpDg
Scale = 1:48.5
1
2
3
4
5
6 7
8
9
16
15
14
13
12 11 10
17
8x8
5x5
7x12 M18SHS
9x10 M18SHS
3x6
6x12 MT18HS
3x4
3x4
3x8
5x6
6x10
8x8
10x12 M18SHS
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
22-0-0
4-2-4
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
22-0-0
4-2-4
24-6-0
2-6-0
1-2-127-2-03-0-82-8-121-3-44.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-4-8], [6:0-2-0,0-1-8], [12:0-4-4,0-4-8], [14:0-5-8,0-4-8], [15:0-5-4,0-3-8], [16:0-5-0,0-7-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.87
0.98
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.51
-0.66
0.30
0.05
(loc)
13-14
13-14
10
14
l/defl
>507
>391
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 133 lb FT = 0%
GRIP
197/144
113/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
7-9: 2x6 SPF 2100F 1.8E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
12-14: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-16: 1.5X5.5 Microllam LVL 2.0E TG, 2-15: 2x4 SPF 2100F 1.8E
8-10: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)10=3168/0-5-8 (min. 0-4-12), 16=3329/0-5-8 (min. 0-5-1)
Max Horz 16=85(LC 7)
Max Uplift16=-27(LC 6)
Max Grav 10=3168(LC 1), 16=3399(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6400/0, 3-4=-8569/0, 4-17=-7675/0, 5-17=-7454/0, 5-6=-4559/0, 6-7=-2850/0,
7-8=-2869/0, 8-9=0/270, 2-16=-3223/43, 8-10=-3135/14
BOT CHORD 15-16=-907/323, 14-15=0/6134, 13-14=0/8253, 12-13=0/7347, 11-12=0/4200
WEBS 3-15=-1395/38, 3-14=0/2115, 4-14=-509/43, 4-13=-945/16, 5-13=0/607, 5-12=-3076/2,
6-12=0/3043, 6-11=-3592/0, 7-11=0/1493, 8-11=0/2896, 2-15=0/5497
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 10, 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 16.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C5
Truss Type
SCISSORS
Qty
2
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203181
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:25 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-weeW3Sr?ooQlD?Nyc6isAiJNTQ_YqyZq1vKliszSpDe
Scale = 1:59.3
1
2
3
4
5
6 7
8
9
10
19
18
17
16
15 14
13
12 11
20
8x8
8x8
8x8
12x18 M18SHS
7x12 M18SHS
12x18 M18SHS
3x4
4x6
3x8
10x10
10x10
5x6
4x10
8x12
8x8
10x12 M18SHS
4x8 MT18HS
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
28-11-10
3-2-8
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
28-11-10
3-2-8
1-2-127-2-02-5-80-11-143-0-34.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-3-4,0-5-4], [9:0-4-0,0-4-8], [11:0-0-0,0-0-13], [12:0-4-4,0-4-8], [14:0-5-0,0-5-12], [15:0-8-9,0-7-7], [19:0-6-0,0-7-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.96
0.99
0.88
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.92
-1.20
0.69
0.09
(loc)
15-16
15-16
11
16
l/defl
>371
>284
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 183 lb FT = 0%
GRIP
118/123
113/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 2100F 1.8E
BOT CHORD 2x6 SPF 2100F 1.8E *Except*
15-17,12-15: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
2-19: 1.5X7.25 Microllam LVL 2.0E TG, 2-18: 2x4 SPF 2100F 1.8E
10-11: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 18-19
2-2-0 oc bracing: 17-18.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)19=4199/0-5-8 (min. 0-5-2), 11=3368/0-3-8 (req. 0-4-3)
Max Horz 19=64(LC 10)
Max Uplift19=-10(LC 6)
Max Grav 19=4202(LC 15), 11=3459(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8786/0, 3-4=-12941/0, 4-20=-13098/0, 5-20=-12995/0, 5-6=-10366/0, 6-7=-8223/0,
7-8=-8484/0, 8-9=-7080/0, 9-10=-4361/0, 2-19=-4047/18, 10-11=-3372/0
BOT CHORD 18-19=-870/811, 17-18=0/8491, 16-17=0/12492, 15-16=0/12633, 14-15=0/9632,
13-14=0/6846, 12-13=0/4066, 11-12=-10/259
WEBS 3-18=-1978/22, 3-17=0/3993, 4-17=-1016/29, 4-16=-2/762, 5-16=0/436, 5-15=-3273/7,
6-15=0/4328, 6-14=-4379/0, 7-14=0/3966, 8-14=0/2013, 8-13=-1738/0, 9-13=0/2781,
9-12=-2494/0, 10-12=0/4088, 2-18=0/7238
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) WARNING: Required bearing size at joint(s) 11 greater than input bearing size.
9) Bearing at joint(s) 19, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint 19.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C5G
Truss Type
SCISSORS
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203182
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:26 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-OqCuHordZ6Ycq9y8ApD5iwsZJpL3ZRXzGZ4JEIzSpDd
Scale = 1:58.2
1
2
3
4
5
6 7
8
9
10
19
18
17
16
15 14
13
12 11
20
8x8
8x8
8x8
12x18 M18SHS
6x12 MT18HS
12x18 M18SHS
3x4
4x6
3x8
8x8
10x10
4x6
4x8
8x10
8x8
10x12 M18SHS
5x8
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
28-11-10
3-2-8
-3-0-0
3-0-0
4-4-0
4-4-0
8-4-8
4-0-8
12-5-0
4-0-8
16-5-8
4-0-8
17-9-12
1-4-4
21-9-7
3-11-11
25-9-2
3-11-11
28-11-10
3-2-8
1-2-127-2-02-5-80-11-143-0-34.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-3-12,0-4-8], [6:0-3-0,0-4-4], [9:0-4-0,0-4-8], [12:0-2-12,0-4-8], [14:0-5-0,0-5-12], [15:0-8-8,0-6-12], [18:0-5-12,0-3-0], [19:0-6-0,0-7-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
3-6-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.96
0.91
0.77
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.81
-1.05
0.60
0.08
(loc)
15-16
15-16
11
16
l/defl
>424
>324
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 367 lb FT = 0%
GRIP
118/123
113/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 2100F 1.8E
BOT CHORD 2x6 SPF 2100F 1.8E *Except*
15-17,12-15: 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
2-19: 1.5X7.25 Microllam LVL 2.0E TG, 2-18: 2x4 SPF 2100F 1.8E
10-11: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (2-4-4 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 18-19.
REACTIONS.(lb/size)19=7348/0-5-8 (min. 0-4-8), 11=5895/0-3-8 (req. 0-3-11)
Max Horz 19=113(LC 10)
Max Uplift19=-18(LC 6)
Max Grav 19=7354(LC 15), 11=6054(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=0/411, 2-3=-15376/0, 3-4=-22646/0, 4-20=-22921/0, 5-20=-22742/0, 5-6=-18141/0,
6-7=-14390/0, 7-8=-14847/0, 8-9=-12389/0, 9-10=-7632/0, 2-19=-7082/32,
10-11=-5901/0
BOT CHORD 18-19=-1522/1419, 17-18=0/14859, 16-17=0/21861, 15-16=0/22108, 14-15=0/16856,
13-14=0/11981, 12-13=0/7115, 11-12=-18/453
WEBS 3-18=-3461/39, 3-17=0/6988, 4-17=-1778/50, 4-16=-4/1334, 5-16=0/764, 5-15=-5728/12,
6-15=0/7574, 6-14=-7664/0, 7-14=0/6941, 8-14=0/3522, 8-13=-3042/0, 9-13=0/4866,
9-12=-4364/0, 10-12=0/7153, 2-18=0/12667
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 1.5x7.25 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 1.5x7.25 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-7-0 oc, Except member 17-3 2x4 - 1 row at 0-9-0 oc, member 4-17 2x4 - 1 row at 0-9-0 oc,
member 16-4 2x4 - 1 row at 0-9-0 oc, member 5-16 2x4 - 1 row at 0-9-0 oc, member 15-5 2x4 - 1 row at 0-9-0 oc, member 15-6 2x4 - 1
row at 0-9-0 oc, member 14-7 2x4 - 1 row at 0-9-0 oc, member 14-8 2x4 - 1 row at 0-9-0 oc, member 8-13 2x4 - 1 row at 0-9-0 oc,
member 13-9 2x4 - 1 row at 0-9-0 oc, member 9-12 2x4 - 1 row at 0-9-0 oc, member 12-10 2x4 - 1 row at 0-9-0 oc, member 18-2 2x4 - 1
row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
C5G
Truss Type
SCISSORS
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203182
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:26 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-OqCuHordZ6Ycq9y8ApD5iwsZJpL3ZRXzGZ4JEIzSpDd
NOTES-
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any
other members.
10) WARNING: Required bearing size at joint(s) 11 greater than input bearing size.
11) Bearing at joint(s) 19, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift at joint 19.
13) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
D1
Truss Type
COMMON
Qty
4
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203183
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:27 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-s1mGU8sFKPgTSJXKkXkKF7Pn7DoIIqg7VDpsnkzSpDc
Scale = 1:40.1
1
2
3
4
5
6
10 9 8
7
11
5x8
4x6
3x4 3x8
4x4 4x4
4x6
4x8 MT18HS 4x8 MT18HS
8-8-4
8-8-4
17-4-8
8-8-4
-2-0-0
2-0-0
4-5-14
4-5-14
8-8-4
4-2-6
12-10-10
4-2-6
17-4-8
4-5-14
3-8-66-7-23-8-64.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.76
0.46
0.96
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.09
-0.22
0.04
0.01
(loc)
7-9
9-10
7
9-10
l/defl
>999
>918
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 94 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
3-10,5-7: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)10=2570/0-5-8 (min. 0-4-0), 7=2018/0-5-8 (min. 0-3-6)
Max Horz 10=69(LC 9)
Max Uplift10=-8(LC 6)
Max Grav 10=2570(LC 1), 7=2149(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-1668/0, 4-5=-1675/0, 2-10=-1065/61, 6-7=-528/10
BOT CHORD 9-10=-4/1307, 8-9=-9/1417, 7-8=-9/1417
WEBS 5-9=-262/420, 3-9=-132/490, 3-10=-1940/0, 5-7=-2049/19
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 10.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
D1G
Truss Type
COMMON
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203184
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:29 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-oPu1vquWs1wAidgjrymoKYU7h1T1ms7QyXIzrdzSpDa
Scale = 1:40.1
1
2
3
4
5
6
10 9 8
7
11
5x8
4x6
3x4 3x8
4x4 4x4
4x6
4x8 MT18HS 4x8 MT18HS
8-8-4
8-8-4
17-4-8
8-8-4
-2-0-0
2-0-0
4-5-14
4-5-14
8-8-4
4-2-6
12-10-10
4-2-6
17-4-8
4-5-14
3-8-66-7-23-8-64.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
4-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.76
0.51
0.46
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.09
-0.22
0.04
0.01
(loc)
7-9
9-10
7
9-10
l/defl
>999
>918
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 188 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
3-10,5-7: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)10=5139/0-5-8 (min. 0-4-0), 7=4037/0-5-8 (min. 0-3-6)
Max Horz 10=137(LC 9)
Max Uplift10=-15(LC 6)
Max Grav 10=5139(LC 1), 7=4298(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=0/309, 2-11=-417/46, 3-11=-160/269, 3-4=-3335/0, 4-5=-3349/0, 5-6=-457/293,
2-10=-2129/123, 6-7=-1056/20
BOT CHORD 9-10=-7/2614, 8-9=-17/2834, 7-8=-17/2834
WEBS 4-9=-74/324, 5-9=-524/840, 3-9=-263/980, 3-10=-3880/0, 5-7=-4098/38
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint 10.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E1
Truss Type
MONOPITCH
Qty
10
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203185
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:30 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-HcSP7Av8dK21JnFvPfH1tm0H6RiRVC8ZBB2WN3zSpDZ
Scale = 1:35.7
1 2
3
4
5
6
7
8
15
14
13
12
11
10
9
16
10x10 4x4
4x8
3x10
4x8
3x6
12x18 M18SHS
8x12
5x5
5x5
5x5
6x6
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
12-2-10
2-11-12
15-2-6
2-11-12
18-5-10
3-3-4
-0-11-10
0-11-10
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
12-2-10
2-11-12
15-2-6
2-11-12
18-5-10
3-3-4
1-3-05-10-72-2-53.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-3-4,0-1-8], [5:0-8-4,0-5-8], [6:0-6-0,0-4-8], [7:0-1-4,0-2-0], [8:0-2-8,0-3-8], [10:0-2-4,0-2-0], [11:0-2-0,0-1-8], [13:0-3-0,0-2-0], [14:0-2-0,0-2-4], [15:0-4-12
,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.71
0.94
0.92
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.60
-0.74
0.41
0.05
(loc)
12-13
12-13
9
12
l/defl
>361
>294
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 111 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG *Except*
9-12: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-15: 1.5X5.5 Microllam LVL 2.0E TG
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)15=1638/0-5-8 (min. 0-1-10), 9=1441/0-5-8 (min. 0-2-4)
Max Horz 15=89(LC 9)
Max Grav 15=1904(LC 15), 9=1878(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-1853/9, 2-3=-4591/0, 3-16=-7818/0, 4-16=-7770/0, 4-5=-7961/0, 5-6=-7870/0,
6-7=-3514/0, 7-8=-1367/10, 8-9=-1814/0
BOT CHORD 14-15=-56/895, 13-14=0/4486, 12-13=0/7729, 11-12=0/3345, 10-11=0/1316
WEBS 2-14=0/3431, 3-14=-1208/12, 3-13=0/3190, 4-13=-741/14, 6-12=0/4913, 6-11=-2196/8,
7-11=0/3011, 7-10=-2228/2, 8-10=0/2199
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 15, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E1DG
Truss Type
GABLE
Qty
10
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203186
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:31 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-lo?nKVvmOeBuxwq6zMpGPzZZfqAbEoPiQrn4wVzSpDY
Scale = 1:35.6
1 2
3
4
5
6
7
8
9
16
15
14
13
12
11
1010x10
5x5
2x4
3x8
3x8
3x8
3x6
3x6
6x8
4x10
3x8
4x6
10x12
7x10
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
9-4-9
0-1-12
12-2-10
2-10-0
15-2-6
2-11-12
18-5-10
3-3-4
-0-11-10
0-11-10
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
12-2-10
2-11-12
15-2-6
2-11-12
18-5-10
3-3-4
1-3-04-1-115-2-152-2-53.00 12
3.00 12
Plate Offsets (X,Y)-- [7:0-9-12,0-6-12], [9:0-2-0,0-3-8], [13:0-4-12,0-5-4], [16:0-4-12,0-3-0], [18:0-1-14,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.28
0.44
0.34
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.27
-0.34
0.19
0.02
(loc)
13-14
13-14
10
13
l/defl
>795
>644
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 234 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG *Except*
10-13: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-16,6-12: 1.5X5.5 Microllam LVL 2.0E TG, 17-18,18-19: 2x4 WW Stud
OTHERS 2x4 WW Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)16=1638/0-5-8 (min. 0-1-8), 10=1441/0-5-8 (min. 0-1-8)
Max Horz 16=89(LC 7)
Max Grav 16=2109(LC 15), 10=1629(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-16=-2053/9, 9-10=-1603/0, 7-12=-2173/11, 2-3=-4758/0, 3-4=-7742/0, 4-5=-7838/0,
5-6=-2880/0, 7-8=-4126/0, 8-9=-1525/5
BOT CHORD 15-16=-57/938, 14-15=0/4630, 13-14=0/7662, 12-13=0/4141, 11-12=0/1439
WEBS 2-15=0/3524, 3-15=-1252/12, 3-14=0/2968, 4-14=-748/14, 5-13=0/1137, 8-12=0/3193,
8-11=-2029/8, 9-11=0/2268, 5-7=-4661/0, 7-13=0/3649
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
5) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
11) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
12) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E1DG
Truss Type
GABLE
Qty
10
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203186
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:31 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-lo?nKVvmOeBuxwq6zMpGPzZZfqAbEoPiQrn4wVzSpDY
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
E1G
Truss Type
MONOPITCH
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203187
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:32 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-D_Z9YrwO9yJlZ4PIW4KVyB6h6ERvzA2sfVXdSyzSpDX
Scale = 1:35.1
1 2
3
4
5
6
7
8
15
14
13
12
11
10
9
16
10x10 3x4
4x8
4x8
4x8
3x6
12x20
8x8
5x5
4x6
5x5
6x6
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
12-2-10
2-11-12
15-2-6
2-11-12
18-5-10
3-3-4
-0-11-10
0-11-10
3-3-4
3-3-4
6-3-1
2-11-12
9-2-13
2-11-12
12-2-10
2-11-12
15-2-6
2-11-12
18-5-10
3-3-4
1-3-05-10-72-2-53.00 12
3.00 12
Plate Offsets (X,Y)-- [5:0-10-0,0-5-11], [6:0-2-12,0-4-8], [7:0-1-12,0-2-0], [8:0-2-12,0-3-8], [11:0-2-0,0-2-4], [15:0-4-12,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.49
0.75
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.45
-0.56
0.31
0.04
(loc)
12-13
12-13
9
12
l/defl
>477
>390
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 222 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG *Except*
9-12: 2x6 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-15: 1.5X5.5 Microllam LVL 2.0E TG
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)15=2457/0-5-8 (min. 0-1-8), 9=2162/0-5-8 (min. 0-2-2)
Max Horz 15=133(LC 9)
Max Grav 15=2856(LC 15), 9=2818(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-2781/13, 2-3=-6889/0, 3-16=-11715/0, 4-16=-11645/0, 4-5=-12048/0,
5-6=-11909/0, 6-7=-5267/0, 7-8=-2054/16, 8-9=-2725/0
BOT CHORD 14-15=-84/1342, 13-14=0/6729, 12-13=0/11593, 11-12=0/5023, 10-11=0/1975
WEBS 2-14=0/5148, 3-14=-1802/17, 3-13=0/4773, 4-13=-1160/20, 4-12=-1/257, 5-12=-257/64,
6-12=0/7489, 6-11=-3331/11, 7-11=0/4507, 7-10=-3336/3, 8-10=0/3305
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-7-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 3-14 2x4 - 1 row at 0-7-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 15, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E2
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203188
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:33 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-hA7XlBx0wFRcAE_U4nrkUOesmem7ie1?t9GA_OzSpDW
Scale = 1:33.9
1
2
3
4
5
6
7
8
15
14
13
12
11
10
9
16
10x10
5x5
3x4
3x8
4x8
4x8
3x6
12x12
5x10
3x8
4x6
6x6
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
-0-11-10
0-11-10
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
1-3-04-2-152-7-102-2-63.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-2-8,0-3-4], [8:0-2-8,0-3-8], [12:0-6-0,0-5-11], [14:0-2-0,0-1-8], [15:0-4-12,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-4-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.50
0.82
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.42
-0.54
0.31
0.04
(loc)
12-13
12-13
9
12-13
l/defl
>519
>399
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 99 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-15: 1.5X5.5 Microllam LVL 2.0E TG, 5-11: 2x4 SPF 2100F 1.8E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)15=1634/0-5-8 (min. 0-2-0), 9=1437/0-5-8 (min. 0-1-12)
Max Horz 15=31(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-1592/4, 2-3=-3750/0, 3-16=-6154/0, 4-16=-6101/0, 4-5=-6295/0, 5-6=-2861/0,
6-7=-2908/0, 7-8=-1765/0, 8-9=-1380/0
BOT CHORD 14-15=-3/717, 13-14=0/3656, 12-13=0/6084, 11-12=0/6164, 10-11=0/1729
WEBS 2-14=0/2807, 3-14=-984/7, 3-13=0/2387, 4-13=-549/11, 4-12=-49/331, 5-12=0/2597,
5-11=-3870/0, 6-11=0/664, 7-11=0/1328, 7-10=-1204/1, 8-10=0/1727
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Bearing at joint(s) 15, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E3
Truss Type
ROOF SPECIAL
Qty
2
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203189
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:34 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-9NhwyXyehZZToOZgeVMz1cB?923UR4q96p0kWqzSpDV
Scale = 1:36.7
1 2
3
4
5
6
7
8
9
16
15
14
13
12
11
10
10x10
5x5
6x6
4x4
3x10
3x8
3x8
3x6
12x14 M18SHS
5x12
3x8
4x6
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
-0-11-10
0-11-10
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
20-5-1
2-0-0
1-3-04-2-152-7-102-2-63.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-2-4,0-1-8], [6:0-2-8,0-3-8], [8:0-2-8,0-3-8], [13:0-7-0,0-5-11], [14:0-2-4,0-1-8], [15:0-3-0,0-1-8], [16:0-4-12,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-6-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.58
0.94
0.62
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.48
-0.62
0.35
0.04
(loc)
13-14
13-14
10
13-14
l/defl
>455
>352
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 103 lb FT = 0%
GRIP
118/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-16: 1.5X5.5 Microllam LVL 2.0E TG, 5-12: 2x4 SPF 2100F 1.8E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-11 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS.(lb/size)16=1816/0-5-8 (min. 0-2-5), 10=2002/0-5-8 (min. 0-2-7)
Max Horz 16=28(LC 9)
Max Grav 16=1899(LC 15), 10=2002(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-16=-1848/4, 2-3=-4412/0, 3-4=-7147/0, 4-5=-7040/0, 5-6=-3101/0, 6-7=-3136/0,
7-8=-1840/0, 8-10=-1939/10
BOT CHORD 15-16=0/840, 14-15=0/4304, 13-14=0/7061, 12-13=0/6885, 11-12=0/1771
WEBS 2-15=0/3308, 3-15=-1160/7, 3-14=0/2706, 4-14=-637/12, 4-13=-121/315, 5-13=0/2986,
5-12=-4521/0, 6-12=0/707, 7-12=0/1580, 7-11=-1261/0, 8-11=0/1840
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
E3GD
Truss Type
ROOF SPECIAL
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203190
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:35 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-dZFIAtyHRthKQY8tCCtCapkEiSUbAaIILTlH3HzSpDU
Scale = 1:36.7
1 2
3
4
5
6
7
8
9
16
15
14
13
12
11
10
10x10
5x6
6x6
2x4
5x6
3x8
3x8
3x6
12x12
4x10
4x4
3x6
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
-0-11-10
0-11-10
3-3-6
3-3-6
6-3-3
2-11-14
9-3-1
2-11-14
11-11-13
2-8-12
15-0-11
3-0-14
18-5-1
3-4-6
20-5-1
2-0-0
1-3-04-2-152-7-102-2-63.00 12
3.00 12
Plate Offsets (X,Y)-- [8:0-2-8,0-3-8], [13:0-6-0,0-5-0], [16:0-4-12,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.34
0.62
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.32
-0.41
0.24
0.03
(loc)
13-14
13-14
10
13
l/defl
>683
>528
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 205 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-16: 1.5X5.5 Microllam LVL 2.0E TG, 5-12: 2x4 SPF 2100F 1.8E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-8-9 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 10-11.
REACTIONS.(lb/size)16=2421/0-5-8 (min. 0-1-9), 10=2670/0-5-8 (min. 0-1-10)
Max Horz 16=37(LC 9)
Max Grav 16=2532(LC 15), 10=2670(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-16=-2464/6, 2-3=-5882/0, 3-4=-9529/0, 4-5=-9387/0, 5-6=-4135/0, 6-7=-4181/0,
7-8=-2453/0, 8-10=-2586/13
BOT CHORD 15-16=0/1120, 14-15=0/5738, 13-14=0/9414, 12-13=0/9180, 11-12=0/2361
WEBS 2-15=0/4411, 3-15=-1547/10, 3-14=0/3609, 4-14=-850/16, 4-13=-162/420, 5-13=0/3981,
5-12=-6028/0, 6-12=0/942, 7-12=0/2107, 7-11=-1681/0, 8-11=0/2453
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 1.5x5.5 - 2 rows staggered at 0-7-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 3-15 2x4 - 1 row at 0-7-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
NOT DESIGNED FOR ANY ADDITIONAL LOADS
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
F1
Truss Type
COMMON
Qty
9
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203191
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:36 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-5lpgNDzvCApB1ij3lwOR61GLdrkQvzgSZ7VrbjzSpDT
Scale = 1:44.3
1
2
3
4
5
6
7
8
14 13 12 11 10 9
15
16
5x12
5x8
4x8 MT18HS
5x8
4x4
4x4
3x4
2x4
4x4
4x4
3x4
2x4
5x12
4-7-3
4-7-3
8-6-11
3-11-9
12-6-4
3-11-9
16-5-13
3-11-9
20-5-5
3-11-9
25-0-8
4-7-3
4-7-3
4-7-3
8-6-11
3-11-9
12-6-4
3-11-9
16-5-13
3-11-9
20-5-5
3-11-9
25-0-8
4-7-3
26-9-14
1-9-6
0-6-124-8-130-6-124.00 12
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.59
0.97
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.35
-0.45
0.15
0.03
(loc)
12
12-13
7
13
l/defl
>853
>652
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 125 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-12,5-12,3-12: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=2931/0-5-8 (min. 0-4-13), 7=3428/0-5-8 (min. 0-5-6)
Max Horz 1=-42(LC 11)
Max Grav 1=3051(LC 15), 7=3436(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=-7179/0, 2-15=-6991/0, 2-3=-5920/0, 3-4=-4643/0, 4-5=-4644/0, 5-6=-5866/0,
6-16=-6452/0, 7-16=-6687/0
BOT CHORD 1-14=0/6552, 13-14=0/6552, 12-13=0/5525, 11-12=0/5477, 10-11=0/5477, 9-10=0/6080,
7-9=0/6080
WEBS 4-12=0/1911, 5-12=-2020/3, 5-10=0/501, 6-10=-922/63, 3-12=-2140/4, 3-13=0/597,
2-13=-1207/12
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
F1G
Truss Type
COMMON
Qty
2
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203192
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:37 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-ZyN2bZ_XzUx2frHFJdvgfEpTbF6beS4bonEO79zSpDS
Scale = 1:44.4
1
2
3
4
5
6
7
8
14 13 12 11 10 9
15
16
5x12
6x8
5x10 M18SHS
5x8
4x6
4x4
3x4
2x4
4x6
4x4
3x4
2x4
5x12
4-7-3
4-7-3
8-6-11
3-11-9
12-6-4
3-11-9
16-5-13
3-11-9
20-5-5
3-11-9
25-0-8
4-7-3
4-7-3
4-7-3
8-6-11
3-11-9
12-6-4
3-11-9
16-5-13
3-11-9
20-5-5
3-11-9
25-0-8
4-7-3
26-9-14
1-9-6
0-6-124-8-130-6-124.00 12
Plate Offsets (X,Y)-- [1:0-0-5,0-0-11], [7:0-0-5,0-0-11]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
4-6-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.83
0.85
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.36
-0.47
0.14
0.03
(loc)
12
12-13
7
13
l/defl
>823
>629
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 251 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 WW Stud *Except*
4-12,5-12,3-12: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (3-2-9 max.)
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=6594/0-5-8 (min. 0-4-6), 7=7712/0-5-8 (min. 0-4-15)
Max Horz 1=-94(LC 13)
Max Grav 1=6866(LC 15), 7=7732(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=-16147/0, 2-15=-15724/0, 2-3=-13319/0, 3-4=-10447/0, 4-5=-10448/0,
5-6=-13198/0, 6-16=-14510/0, 7-16=-15039/0, 7-8=0/253
BOT CHORD 1-14=0/14738, 13-14=0/14738, 12-13=0/12425, 11-12=0/12318, 10-11=0/12318,
9-10=0/13679, 7-9=0/13679
WEBS 4-12=0/4302, 5-12=-4536/8, 5-10=0/1139, 6-10=-2080/138, 6-9=-253/298,
3-12=-4807/10, 3-13=0/1351, 2-13=-2718/27, 2-14=-64/315
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
THIS DRAWING ASSUMES NO RESPONSIBILITY FOR THE DESIGN OF THE LATERAL BRACING
SHOWN. DUE TO THE WIDE SPACING OF THE TRUSSES, SPECIAL CONSIDERATIONS MUST BE
GIVEN IN THIS AREA. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER/ARCHITECT
TO SPECIFY PROPER BRACING SIZE AND ATTACHMENT.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
G1
Truss Type
MONOPITCH
Qty
3
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203193
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:38 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-28xQov?9ko3vH?sStLRvBSMjlfWQNtFk1R_xfbzSpDR
Scale = 1:26.1
1
2
3
4
5
6
9 8 7
10
3x4
3x8 6x6
4x8
3x4
2x4 3x4
4x4
4-2-0
4-2-0
8-0-9
3-10-8
12-2-9
4-2-0
-1-6-0
1-6-0
4-2-0
4-2-0
8-0-9
3-10-8
12-2-9
4-2-0
0-10-04-4-123.50 12
Plate Offsets (X,Y)-- [2:0-3-8,0-2-7]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.48
0.62
0.65
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.13
0.05
0.01
(loc)
8-9
8-9
7
9
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 58 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
5-7: 2x4 SPF 1650F 1.5E
SLIDER Left 2x4 WW Stud 2-1-6
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-15 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)7=1426/Mechanical, 2=1815/0-5-8 (min. 0-3-5)
Max Horz 2=97(LC 7)
Max Uplift2=-9(LC 6)
Max Grav 7=1833(LC 15), 2=2127(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-10=-3303/0, 3-10=-3093/0, 3-4=-2951/0, 4-5=-2096/0, 6-7=-463/16
BOT CHORD 2-9=0/2833, 8-9=0/2833, 7-8=0/1934
WEBS 4-8=-979/5, 5-8=0/476, 5-7=-2320/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide metal plate or equivalent at bearing(s) 7 to support reaction shown.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 lb uplift at joint 2.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
G2
Truss Type
MONOPITCH
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203194
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:38 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-28xQov?9ko3vH?sStLRvBSMhUfcWNs2k1R_xfbzSpDR
Scale = 1:27.3
1
2
3
4
7
6 5
8
3x6
3x6
4x4
4x4
3x8
9x10 M18SHS
4-7-14
4-7-14
9-3-13
4-7-15
-3-9-15
3-9-15
4-7-14
4-7-14
9-3-13
4-7-15
1-8-24-4-123.50 12
Plate Offsets (X,Y)-- [6:0-3-8,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.63
0.23
0.73
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.03
-0.03
-0.01
-0.00
(loc)
6
5-6
5
5-6
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 60 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x8 SPF 1950F 1.7E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
2-7: 2x6 SPF 1650F 1.5E, 2-6: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=862/Mechanical, 7=2195/0-5-9 (min. 0-4-1)
Max Horz 7=106(LC 7)
Max Uplift5=-32(LC 14), 7=-78(LC 6)
Max Grav 5=1156(LC 15), 7=2588(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-8=0/279, 2-3=-1173/214, 4-5=-614/19, 2-7=-2532/104
BOT CHORD 6-7=-694/54, 5-6=-264/884
WEBS 3-6=-307/132, 3-5=-984/312, 2-6=0/1348
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
9) Provide metal plate or equivalent at bearing(s) 5 to support reaction shown.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 5 and 78 lb uplift at joint
7.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
G3
Truss Type
MONOPITCH
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203195
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:39 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-WKUp0F0nV5Bmu9ReR2y8kfuoP3_I6M2uG5jVC2zSpDQ
Scale = 1:27.6
1
2
3
8
4
7
6 5
9
3x6
3x6
4x4
8x8
3x4
9x10 M18SHS
4-3-9
4-3-9
8-7-1
4-3-8
-5-1-8
5-1-8
4-3-9
4-3-9
8-7-1
4-3-8
1-10-114-4-123.50 12
Plate Offsets (X,Y)-- [2:0-2-5,0-4-8], [3:0-4-0,0-5-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.87
0.13
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
0.02
-0.54
-0.00
0.00
(loc)
6
1-2
5
6
l/defl
>999
>120
n/a
>999
L/d
360
80
n/a
240
PLATES
MT20
M18SHS
Weight: 93 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x8 SPF 1950F 1.7E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud
OTHERS 2x8 SPF 1950F 1.7E
LBR SCAB 1-4 2x8 SPF 1950F 1.7E one side
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=615/Mechanical, 7=2554/0-5-9 (min. 0-4-12)
Max Horz 7=110(LC 9)
Max Uplift5=-214(LC 14), 7=-116(LC 6)
Max Grav 5=881(LC 15), 7=3009(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-9=0/372, 2-3=-701/398, 4-5=-667/18, 2-7=-2975/135
BOT CHORD 5-6=-604/278
WEBS 3-6=-1/323, 3-5=-332/719, 2-6=-641/295
NOTES-
1) Attached 14-5-9 scab 1 to 4, front face(s) 2x8 SPF 1950F 1.7E with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at
4-6-15 from end at joint 1, nail 2 row(s) at 2" o.c. for 2-0-0; starting at 8-10-13 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0;
starting at 12-2-10 from end at joint 1, nail 2 row(s) at 4" o.c. for 2-0-0.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 214 lb uplift at joint 5 and 116 lb uplift at
joint 7.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
H1
Truss Type
Roof Special
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203196
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:40 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-_X2BDa0PGPJdWJ0q_lTNGtR70T84rj?1UlT2kUzSpDP
Scale = 1:31.6
1
2
3
4
5
6
7
12 11
10
9 8
13 146x8
6x6
6x8
4x4
6x12 MT18HS
6x12 MT18HS
4x4
7x10
3x6
2x4
3x6
2x4
2-10-12
2-10-12
9-2-0
6-3-4
15-5-4
6-3-4
18-4-0
2-10-12
2-10-12
2-10-12
6-0-6
3-1-10
9-2-0
3-1-10
12-3-10
3-1-10
15-5-4
3-1-10
18-4-0
2-10-12
1-2-124-3-71-2-121-6-134.00 12
3.00 12
Plate Offsets (X,Y)-- [1:0-4-0,0-3-8], [7:0-4-0,0-3-8], [9:0-5-4,0-2-8], [11:0-5-4,0-2-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.24
0.86
0.96
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.22
-0.30
0.18
0.02
(loc)
10
10-11
8
10
l/defl
>957
>716
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 83 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-10,1-11,7-9: 2x4 SPF 1650F 1.5E, 1-12,7-8: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-14 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)12=2145/0-5-8 (min. 0-3-6), 8=2145/0-5-8 (min. 0-3-6)
Max Horz 12=-8(LC 13)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=-3002/0, 2-13=-2844/0, 2-3=-3045/0, 3-4=-4522/0, 4-5=-4522/0, 5-6=-3045/0,
6-14=-2844/0, 7-14=-3002/0, 1-12=-2105/0, 7-8=-2105/0
BOT CHORD 11-12=-12/353, 10-11=0/4161, 9-10=0/4161, 8-9=-7/353
WEBS 4-10=0/1928, 5-10=-309/708, 5-9=-1682/0, 6-9=-802/36, 3-10=-309/708, 3-11=-1682/0,
2-11=-802/36, 1-11=0/2573, 7-9=0/2573
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
H1G
Truss Type
ROOF SPECIAL
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203197
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:41 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-SjcZQw111jRT8Tb1YT_cp4_H6sSzaFFBjPCcGwzSpDO
Scale = 1:31.6
1
2
3
4
5
6
7
12 11
10
9 8
13 146x8
6x6
6x8
4x4
6x12 MT18HS
6x12 MT18HS
4x4
7x10
3x6
2x4
3x6
2x4
2-10-12
2-10-12
9-2-0
6-3-4
15-5-4
6-3-4
18-4-0
2-10-12
2-10-12
2-10-12
6-0-6
3-1-10
9-2-0
3-1-10
12-3-10
3-1-10
15-5-4
3-1-10
18-4-0
2-10-12
1-2-124-3-71-2-121-6-134.00 12
3.00 12
Plate Offsets (X,Y)-- [1:0-4-0,0-3-8], [7:0-4-0,0-3-8], [9:0-5-4,0-2-8], [11:0-5-4,0-2-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
4-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.28
0.95
0.64
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.22
-0.30
0.18
0.02
(loc)
10
10-11
8
10
l/defl
>957
>716
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 166 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-10,1-11,7-9: 2x4 SPF 1650F 1.5E, 1-12,7-8: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)12=4290/0-5-8 (min. 0-3-6), 8=4290/0-5-8 (min. 0-3-6)
Max Horz 12=15(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=-6005/0, 2-13=-5689/0, 2-3=-6090/0, 3-4=-9044/0, 4-5=-9044/0, 5-6=-6090/0,
6-14=-5689/0, 7-14=-6005/0, 1-12=-4209/0, 7-8=-4209/0
BOT CHORD 11-12=-23/707, 10-11=0/8321, 9-10=0/8321, 8-9=-14/707
WEBS 4-10=0/3857, 5-10=-619/1416, 5-9=-3364/0, 6-9=-1605/72, 3-10=-619/1416,
3-11=-3364/0, 2-11=-1605/71, 1-11=0/5146, 7-9=0/5146
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
H2
Truss Type
Roof Special
Qty
5
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203198
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:42 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-wvAxeG2go0ZKldAD6AVrMIWTdGpvJjUKy3y9oNzSpDN
Scale = 1:30.8
1
2
3
4
5
6
7
12
11
10
9 8
13 146x8
5x6
3x4
6x12 MT18HS 6x12 MT18HS 3x4
2x4
4x4
8x8
3x6
2x4
6x8
2-10-12
2-10-12
9-2-0
6-3-4
15-5-4
6-3-4
17-10-8
2-5-4
2-10-12
2-10-12
6-0-6
3-1-10
9-2-0
3-1-10
12-3-10
3-1-10
15-5-4
3-1-10
17-10-8
2-5-4
1-2-124-3-71-4-91-6-134.00 12
3.00 12
Plate Offsets (X,Y)-- [1:0-4-0,0-3-8], [7:0-4-0,0-3-8], [9:0-5-12,0-2-8], [10:0-4-0,0-3-10], [11:0-5-4,0-2-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.23
0.84
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.19
-0.27
0.16
0.02
(loc)
10
10-11
8
10
l/defl
>999
>777
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 83 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-11,3-10,5-10,6-9: 2x4 WW Stud, 1-12,7-8: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-1-9 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)12=2090/0-5-8 (min. 0-3-4), 8=2090/Mechanical
Max Horz 12=9(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=-2888/0, 2-13=-2730/0, 2-3=-2911/0, 3-4=-4300/0, 4-5=-4299/0, 5-6=-2518/0,
6-14=-2334/0, 7-14=-2463/0, 1-12=-2047/0, 7-8=-2057/0
BOT CHORD 11-12=-12/358, 10-11=0/4033, 9-10=0/3858
WEBS 2-11=-736/37, 3-11=-1672/0, 3-10=-374/613, 4-10=0/1837, 5-10=-223/745, 5-9=-1945/0,
6-9=-745/34, 1-11=0/2436, 7-9=0/2300
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
I1
Truss Type
MONO SCISSOR
Qty
9
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203199
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:43 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-O6kJrc3IZKhBNmlPgu04uV3XZgFL29lUAjhiLpzSpDM
Scale = 1:34.0
1
2
3
4
5
6
11
10
9
8
7
12
8x8
10x12
4x8
3x8
4x4
2x4
5x10
6x10
5x10 M18SHS
3-6-6
3-6-6
6-9-4
3-2-14
10-0-2
3-2-14
13-6-8
3-6-6
-3-6-0
3-6-0
3-6-6
3-6-6
6-9-4
3-2-14
10-0-2
3-2-14
13-6-8
3-6-6
1-3-85-2-141-11-23-3-122-0-83-2-63.50 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-4-8], [6:0-5-0,0-3-8], [7:0-5-0,0-2-1], [8:0-1-15,0-2-4], [10:0-2-0,0-2-4], [11:0-5-4,0-3-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.67
0.50
0.64
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.18
-0.22
0.02
0.01
(loc)
9
9
7
9
l/defl
>881
>719
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 87 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 1.5X5.5 Microllam LVL 2.0E TG
BOT CHORD 1.5X5.5 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
6-7: 2x6 SPF 1650F 1.5E, 2-11: 1.5X5.5 Microllam LVL 2.0E TG
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-3-10 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.(lb/size)11=2507/0-3-8 (min. 0-2-8), 7=1453/0-3-8 (min. 0-1-8)
Max Horz 11=96(LC 7)
Max Uplift11=-50(LC 6)
Max Grav 11=2916(LC 15), 7=1953(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-12=-3668/470, 3-12=-3450/487, 3-4=-5277/0, 4-5=-3589/0, 5-6=-3530/0,
6-7=-1513/12, 2-11=-2640/62
BOT CHORD 10-11=-1198/123, 9-10=-523/3518, 8-9=0/5138, 7-8=0/787
WEBS 3-10=-1139/30, 3-9=-12/1591, 4-9=-388/57, 4-8=-1662/98, 5-8=-757/38, 6-8=0/3194,
2-10=0/3408
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 11, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 50 lb uplift at joint 11.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
J1
Truss Type
SCISSORS
Qty
6
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203200
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:44 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-sIIi3y3wKep2?wKbDbXJRjce74cNne0dPNRGtFzSpDL
Scale = 1:54.3
1
2
3
4
5
6
11
10
9
8
7
8x8
6x6
9x10 M18SHS
3x8 M18SHS 3x8 M18SHS
6x8
3x6
4x6 4x6
9x10 M18SHS
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
-3-0-0
3-0-0
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
1-7-48-7-41-7-42-6-28.00 12
3.00 12
Plate Offsets (X,Y)-- [2:0-3-4,Edge], [3:0-4-0,0-4-8], [4:0-3-12,0-3-0], [6:0-3-4,Edge], [7:0-4-0,0-0-12], [8:0-2-4,0-1-12], [9:0-4-0,0-3-8], [10:0-2-4,0-1-12], [11:0-4-0,0-0-12]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.94
0.39
0.51
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.12
-0.16
0.11
0.01
(loc)
9
8-9
7
9
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 128 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-9,2-10,6-8: 2x4 SPF 1650F 1.5E, 2-11,6-7: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 10-11.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)11=3264/0-5-8 (min. 0-4-14), 7=2405/0-5-8 (min. 0-3-10)
Max Horz 11=159(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=0/410, 2-3=-3438/0, 3-4=-3003/0, 4-5=-3012/0, 5-6=-3635/0, 2-11=-3120/0,
6-7=-2439/0
BOT CHORD 10-11=-705/176, 9-10=0/2648, 8-9=0/2849, 7-8=-11/610
WEBS 4-9=0/1805, 5-9=-522/68, 5-8=-529/49, 3-9=-311/107, 3-10=-657/38, 2-10=0/2716,
6-8=0/2151
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Bearing at joint(s) 11, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
J1G
Truss Type
SCISSORS
Qty
1
Ply
2
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203201
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:45 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-KUs4GI4Y5xxvc4vonJ3Yzw8qPUy?W5Mme1ApPhzSpDK
Scale = 1:54.3
1
2
3
4
5
6
11
10
9
8
7
8x8
6x6
9x10 M18SHS
3x8 M18SHS 5x8
6x8
3x6
3x10 4x6
9x10 M18SHS
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
-3-0-0
3-0-0
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
1-7-48-7-41-7-42-6-28.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-4-8], [4:0-3-12,0-3-0], [6:Edge,0-3-8], [9:0-4-0,0-3-8], [10:0-2-4,0-1-12], [11:0-4-0,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
4-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.84
0.43
0.50
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.12
-0.16
0.11
0.01
(loc)
8-9
8-9
7
9
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 257 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
1-3: 2x6 SPF 2100F 1.8E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-9,2-10,6-8: 2x4 SPF 1650F 1.5E, 2-11,6-7: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 10-11.
REACTIONS.(lb/size)11=6527/0-5-8 (min. 0-4-14), 7=4809/0-5-8 (min. 0-3-10)
Max Horz 11=317(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=0/819, 2-3=-6884/0, 3-4=-6003/0, 4-5=-6024/0, 5-6=-7269/0, 2-11=-6258/0,
6-7=-4879/0
BOT CHORD 10-11=-1345/352, 9-10=0/5293, 8-9=0/5697, 7-8=-21/1220
WEBS 4-9=0/3605, 5-9=-1043/136, 5-8=-1057/98, 3-9=-620/216, 3-10=-1292/79, 2-10=0/5367,
6-8=0/4302
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 11, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
THIS DRAWING ASSUMES NO RESPONSIBILITY FOR THE DESIGN OF THE LATERAL BRACING
SHOWN. DUE TO THE WIDE SPACING OF THE TRUSSES, SPECIAL CONSIDERATIONS MUST BE
GIVEN IN THIS AREA. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER/ARCHITECT
TO SPECIFY PROPER BRACING SIZE AND ATTACHMENT.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
J1GD
Truss Type
SCISSORS
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203202
7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:57:26 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-mbIq_uWToubXQvy19x1b_Uiu1wrIYJH?QltUgzzSkB7
Scale = 1:52.4
A
B
C
D
E
F
K
J
I
H
G
8x8
6x6
9x10 M18SHS
4x8 MT18HS 4x8 MT18HS
10x12
3x6
5x8 5x8
9x10 M18SHS
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
-3-0-0
3-0-0
5-4-12
5-4-12
10-6-0
5-1-4
15-7-4
5-1-4
21-0-0
5-4-12
1-7-48-7-41-7-42-6-28.00 12
3.00 12
Plate Offsets (X,Y)-- [B:0-4-4,0-3-8], [C:0-4-0,0-4-8], [F:Edge,0-3-8], [G:0-0-0,0-0-13], [K:0-0-0,0-0-13]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.48
0.56
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.16
-0.20
0.14
0.01
(loc)
H-I
H-I
G
I
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 403 lb FT = 0%
GRIP
169/123
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
D-I: 2x8 SPF 1950F 1.7E, B-K,F-G: 2x6 SPF 1650F 1.5E
B-J,F-H: 2x4 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: J-K.
REACTIONS.(lb/size)K=7860/0-5-8 (min. 0-3-15), G=8593/0-5-8 (min. 0-4-5)
Max Horz K=159(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=0/410, B-C=-11575/0, C-D=-13080/0, D-E=-13681/0, E-F=-13859/0, B-K=-7753/0,
F-G=-8749/0
BOT CHORD J-K=-192/471, I-J=0/9564, H-I=0/11195, G-H=0/1745
WEBS D-I=0/12204, E-I=-193/1255, E-H=-2482/0, C-I=0/1712, C-J=-2327/0, B-J=0/8783,
F-H=0/9102
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x8 - 4 rows staggered at 0-4-0 oc, 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Bearing at joint(s) K, G considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
11) Load case(s) 1, 2, 12, 14, 15, 16, 17 has/have been modified. Building designer must review loads to verify that they are correct for
the intended use of this truss.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 7600 lb down at 10-6-0 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) StandardContinued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
J1GD
Truss Type
SCISSORS
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203202
7.600 s Sep 19 2014 MiTek Industries, Inc. Wed Apr 08 13:57:27 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-EosDCEX5ZBjO23XDjfYqWhF3mKAXHmX9fPc2CPzSkB6
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: A-B=-220, B-D=-220, D-F=-530, I-K=-20, G-I=-20
Concentrated Loads (lb)
Vert: I=-7600(F)
2) Dead + 0.75 Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: A-B=-170, B-D=-170, D-F=-415, I-K=-20, G-I=-20
Concentrated Loads (lb)
Vert: I=-5950(F)
12) Dead + Snow on Overhangs: Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: A-B=-220, B-D=-20, D-F=-72, I-K=-20, G-I=-20
Concentrated Loads (lb)
Vert: I=-7600(F)
14) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.33, Plate Increase=1.33
Uniform Loads (plf)
Vert: A-B=-174, B-D=-177, D-F=-428, I-K=-20, G-I=-20
Horz: A-B=4, B-D=7, D-F=5, B-K=13, F-G=3
Concentrated Loads (lb)
Vert: I=-5950(F)
15) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.33, Plate Increase=1.33
Uniform Loads (plf)
Vert: A-B=-162, B-D=-165, D-F=-432, I-K=-20, G-I=-20
Horz: A-B=-8, B-D=-5, D-F=-7, B-K=-3, F-G=-13
Concentrated Loads (lb)
Vert: I=-5950(F)
16) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.33, Plate Increase=1.33
Uniform Loads (plf)
Vert: A-B=-157, B-D=-161, D-F=-426, I-K=-20, G-I=-20
Horz: A-B=-13, B-D=-9, D-F=3, B-K=11, F-G=2
Concentrated Loads (lb)
Vert: I=-5950(F)
17) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.33, Plate Increase=1.33
Uniform Loads (plf)
Vert: A-B=-163, B-D=-167, D-F=-410, I-K=-20, G-I=-20
Horz: A-B=-7, B-D=-3, D-F=9, B-K=-2, F-G=-11
Concentrated Loads (lb)
Vert: I=-5950(F)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
K1
Truss Type
Roof Special
Qty
4
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203203
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:46 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-phPSUe5AsF3mEET_L0anW8h5ZtHRFR3wthwNx8zSpDJ
Scale = 1:60.4
1
2
3
4
5
9
8
7
6
9x10 M18SHS
6x8
3x4
4x4
5x10
3x6
3x8
2x4
3x8
5-6-8
5-6-8
10-9-8
5-3-0
16-4-0
5-6-8
5-6-8
5-6-8
10-9-8
5-3-0
12-6-3
1-8-11
16-4-0
3-9-13
1-4-79-8-99-9-150-1-64-7-02-8-68.00 12
3.00 12
Plate Offsets (X,Y)-- [1:Edge,0-3-8], [7:0-3-12,0-2-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.43
0.48
0.92
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.08
-0.12
-0.05
0.01
(loc)
7-8
7-8
9
8
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 95 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-7,1-8,4-6: 2x4 SPF 1650F 1.5E, 1-9: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-6
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=1915/0-5-8 (min. 0-2-14), 6=1915/Mechanical
Max Horz 6=177(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2937/0, 2-3=-1854/0, 3-4=-1567/41, 1-9=-1973/0, 5-6=-351/39
BOT CHORD 8-9=-10/526, 7-8=0/2255, 6-7=0/854
WEBS 2-8=-259/125, 2-7=-998/61, 3-7=-671/68, 4-7=-8/1708, 1-8=0/1677, 4-6=-1721/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
8) Provide metal plate or equivalent at bearing(s) 6 to support reaction shown.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
L1
Truss Type
ROOF SPECIAL
Qty
3
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203204
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:47 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-Htzqh_6odZCdsO2Avk503LEDIHUx_vH35KfwUazSpDI
Scale = 1:45.6
1
2
3
4
5
6
7
8
13
12
11
10 9
14
15
16 17
8x10
5x10
3x6
4x6
7x12 M18SHS
6x10
3x8
5x8
2x4
2x4
7x10
4x8 MT18HS
3-4-10
3-4-10
6-5-12
3-1-2
12-6-0
6-0-4
18-6-0
6-0-0
-1-6-0
1-6-0
3-4-10
3-4-10
6-5-12
3-1-2
11-5-11
4-11-15
12-6-0
1-0-5
14-8-3
2-2-3
18-6-0
3-9-13
1-2-04-11-147-1-94-7-01-6-14.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [2:0-4-10,0-3-8], [5:0-6-12,0-4-8], [10:0-4-8,0-1-8], [12:0-3-0,0-2-8], [13:0-0-8,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.62
0.97
0.86
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.36
-0.49
0.23
0.04
(loc)
10-11
10-11
9
11
l/defl
>602
>447
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 108 lb FT = 0%
GRIP
169/123
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
3-12,4-11,6-10: 2x4 WW Stud, 2-13: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 7-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)13=2591/0-5-8 (min. 0-3-14), 9=2155/Mechanical
Max Horz 13=150(LC 7)
Max Grav 13=2600(LC 27), 9=2155(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-14=-4779/0, 3-14=-4585/0, 3-4=-6369/0, 4-5=-6395/0, 5-15=-2191/0, 6-15=-2135/0,
6-7=-1904/20, 7-8=-359/322, 2-13=-2607/4, 8-9=-584/37
BOT CHORD 12-13=-175/447, 11-12=0/4491, 10-11=0/2307, 10-16=0/981, 16-17=0/981, 9-17=0/981
WEBS 3-12=-1141/10, 3-11=0/1655, 4-11=-965/57, 5-11=0/4595, 5-10=-2668/34,
6-10=-127/363, 7-10=0/2177, 2-12=0/3909, 7-9=-1963/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
L2
Truss Type
ROOF SPECIAL
Qty
3
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203205
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:49 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-DF5a6f738ASL5hCZ087U8mJZx5DQSn8MZe81YTzSpDG
Scale: 1/4"=1’
1
2
3
4
5
6
7
8
9
10
17
16
15
14 13
12 11
18
19
20
8x12
5x8
10x12
12x14 M18SHS
7x10 2x4
6x10
5x6
4x10
2x4
3x6
3x8
4x6
3x12
3-4-10
3-4-10
6-5-12
3-1-2
12-6-0
6-0-4
14-9-8
2-3-8
21-0-0
6-2-8
-1-6-0
1-6-0
3-4-10
3-4-10
6-5-12
3-1-2
11-5-11
4-11-15
12-6-0
1-0-5
14-8-3
2-2-3
17-8-5
3-0-2
21-0-0
3-3-11
22-7-0
1-7-0
1-2-04-11-147-1-91-2-01-9-04.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [5:0-8-8,0-4-0], [12:0-3-4,0-2-8], [14:0-3-12,0-2-8], [15:0-7-0,0-3-10], [16:0-3-0,0-2-0], [17:0-5-0,0-8-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.61
0.78
0.96
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.42
-0.57
0.21
0.04
(loc)
14-15
14-15
11
15
l/defl
>586
>436
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 123 lb FT = 0%
GRIP
169/123
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
1-5: 2x6 SPF 2100F 1.8E
BOT CHORD 2x4 SPF 1650F 1.5E *Except*
15-17: 2x4 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
3-16,4-15,6-14,6-12,8-12: 2x4 WW Stud, 2-17,9-11: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)17=2859/0-5-8 (min. 0-3-10), 11=2894/0-5-8 (min. 0-4-11)
Max Horz 17=111(LC 9)
Max Grav 17=3010(LC 27), 11=2972(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5580/0, 3-4=-7720/0, 4-19=-7745/0, 5-19=-7559/0, 5-6=-2974/0, 6-7=-2597/0,
7-8=-2624/0, 8-9=-655/166, 9-20=0/335, 2-17=-3038/0, 9-11=-1407/0
BOT CHORD 16-17=-148/616, 15-16=0/5258, 14-15=0/3116, 7-12=0/2097, 11-12=0/1980
WEBS 3-16=-1328/6, 3-15=0/2178, 4-15=-997/61, 5-15=0/5155, 5-14=-3070/18, 6-14=-87/730,
12-14=0/2979, 6-12=-444/255, 8-12=-225/417, 2-16=0/4492, 8-11=-2356/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
L2GD
Truss Type
ROOF SPECIAL GIRDER
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203206
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:51 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-9eDLXL9Jgni3K?My8ZAyDBO_2uvawlsf0yd7dLzSpDE
Scale: 1/4"=1’
1
2
3
4
5
6
7
8
9
10
18
17
16
15
14 13 12 11
19
20
6x6
5x6
8x8 6x6
4x4
4x8
8x8
5x6
4x6
3x6
4x8
4x6
10x12
8x8
5x6
3-4-10
3-4-10
6-5-12
3-1-2
9-5-14
3-0-2
12-6-0
3-0-2
14-8-3
2-2-3
18-8-4
4-0-1
21-0-0
2-3-12
-1-6-0
1-6-0
3-4-10
3-4-10
6-5-12
3-1-2
11-5-11
4-11-15
12-6-0
1-0-5
14-8-3
2-2-3
18-8-4
4-0-1
21-0-0
2-3-12
22-7-0
1-7-0
1-2-04-11-147-1-92-11-01-10-51-6-14.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [8:0-1-8,0-2-0], [9:0-4-0,0-3-12], [12:0-4-12,Edge], [14:0-3-0,0-3-4], [16:0-4-0,0-5-8], [18:0-4-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.32
0.80
0.76
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.25
-0.32
0.15
0.02
(loc)
15-16
15-16
11
16
l/defl
>999
>780
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 443 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
3-16,4-16,7-13,2-17,9-12: 2x4 SPF 1650F 1.5E
8-12: 1.5X7.25 Microllam LVL 2.0E TG, 2-18,9-11: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 17-18,11-12.
REACTIONS.(lb/size)18=4023/0-5-8 (min. 0-2-1), 11=13316/0-5-8 (min. 0-1-12)
Max Horz 18=140(LC 33)
Max Grav 18=4166(LC 27), 11=13424(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-9163/0, 3-4=-13127/0, 4-20=-7934/0, 5-20=-7745/0, 5-6=-6132/0, 6-7=-5124/0,
7-8=-5206/0, 8-9=-7973/0, 9-10=0/336, 2-18=-4190/0, 9-11=-12642/0
BOT CHORD 17-18=-34/1612, 16-17=0/8659, 15-16=0/12685, 14-15=0/6292, 13-14=0/5022,
12-13=0/6262, 11-12=-11/508
WEBS 3-17=-1834/0, 3-16=0/3975, 4-16=0/4205, 4-15=-6223/0, 5-15=0/2944, 5-14=-4372/0,
6-14=0/2232, 6-13=-2167/0, 7-13=0/4632, 8-13=-3200/294, 8-12=-657/4065,
2-17=0/6819, 9-12=0/9186
NOTES-
1) Special connection required to distribute web loads equally between all plies.
2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 1.5x7.25 - 4 rows staggered at 0-4-0 oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
5) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
10) Bearing at joint(s) 18, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
11) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
ICC APPROVED FACE MOUNT HANGER (BY OTHERS) REQUIRED AT CONCENTRATED
LOADS SHOWN IN NOTES BELOW. ALL NAILS HOLES MUST BE FILLED AS
PER HANGER MANUFACTURERS INSTALLATION PROCEDURE WITH A
MINIMUM OF 10d (.148" X 3") NAILS OR AS REQUIRED BY THE HANGERMANUFACTURER. FAILURE TO COMPLY MAY REQUIRE ADDITIONAL
CONSIDERATIONS TO DISTRIBUTE LOADS BETWEEN THE PLIES.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
L2GD
Truss Type
ROOF SPECIAL GIRDER
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203206
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:51 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-9eDLXL9Jgni3K?My8ZAyDBO_2uvawlsf0yd7dLzSpDE
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11630 lb down at 18-8-4 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-2=-220, 2-5=-220, 5-7=-220, 7-9=-220, 9-10=-220, 16-18=-20, 14-16=-20, 11-14=-20
Concentrated Loads (lb)
Vert: 12=-11630(B)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
L3
Truss Type
ROOF SPECIAL
Qty
2
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203207
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:52 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-dqnjkhAxR5qwy9x8hHhBmPx6VIF9fBGoFcNh9nzSpDD
Scale = 1:47.2
1
2
3
4
5
6
7
8
9
15 14 13 12
11 10
16
17
18
5x8
5x8
2x4
6x8
3x4
5x6
3x4
5x10
4x6
6x6
4x10
4x6
3x12
5-10-10
5-10-10
11-5-11
5-7-2
14-9-8
3-3-12
21-0-0
6-2-8
-1-6-0
1-6-0
4-0-4
4-0-4
7-9-0
3-8-12
11-5-11
3-8-12
14-8-3
3-2-7
17-8-5
3-0-2
21-0-0
3-3-11
22-7-0
1-7-0
1-2-04-11-147-1-91-2-01-9-04.00 12
8.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-2-12], [5:0-6-8,0-3-0], [11:0-2-0,0-3-4], [13:0-1-12,0-2-8], [15:Edge,0-2-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.46
0.78
0.75
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.17
-0.24
0.09
0.02
(loc)
13-14
13-14
10
13-14
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 119 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-13,11-13,3-15,7-10: 2x4 SPF 1650F 1.5E
2-15,8-10: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-2-13 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 12-13.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)15=2859/0-5-8 (min. 0-4-12), 10=2894/0-5-8 (min. 0-4-11)
Max Horz 15=111(LC 9)
Max Grav 15=3010(LC 27), 10=2972(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-765/138, 3-4=-3811/0, 4-17=-3047/0, 5-17=-2896/0, 5-6=-2700/0, 6-7=-2622/0,
7-8=-663/164, 8-18=0/335, 2-15=-1300/35, 8-10=-1405/0
BOT CHORD 14-15=0/3421, 13-14=0/3558, 6-11=0/1939, 10-11=0/1978
WEBS 4-13=-1398/25, 5-13=-757/8, 11-13=0/3091, 5-11=-907/31, 7-11=-233/432,
3-15=-3347/0, 7-10=-2345/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
L4
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203208
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:52 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-dqnjkhAxR5qwy9x8hHhBmPx71IHyf8joFcNh9nzSpDD
Scale = 1:39.8
1
2
3
4
5
6
10
9 8 7
11
3x4
3x4
4x6
4x4
4x8
6x10
4x8
6x6
4x10
5-10-10
5-10-10
11-5-11
5-7-2
14-9-8
3-3-12
16-2-0
1-4-8
-1-6-0
1-6-0
4-0-4
4-0-4
7-9-0
3-8-12
11-5-11
3-8-12
14-8-3
3-2-7
16-2-0
1-5-13
1-2-04-11-147-0-17-1-90-3-84.00 12
8.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-2-12], [5:0-7-12,0-3-0], [8:0-3-8,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.43
0.66
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.15
0.06
0.01
(loc)
8-9
8-9
7
9
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 83 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
3-9,4-9,5-8: 2x4 WW Stud, 2-10: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-9-3 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)7=1705/0-5-8 (min. 0-3-4), 10=2151/0-5-8 (min. 0-4-3)
Max Horz 10=169(LC 9)
Max Uplift10=-14(LC 6)
Max Grav 7=2060(LC 15), 10=2670(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-715/149, 3-11=-683/169, 3-4=-2949/0, 4-5=-1436/21, 6-7=-276/19,
2-10=-1220/42
BOT CHORD 9-10=-17/2891, 8-9=0/2449, 7-8=0/1230
WEBS 3-9=-354/88, 4-9=0/396, 4-8=-1662/21, 5-8=0/1180, 5-7=-2148/0, 3-10=-2778/8
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 10.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M1
Truss Type
ROOF SPECIAL
Qty
4
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203209
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:54 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-aDuT9NBBzi4dBT5Wpijgrq0Mf6ya75_5iwsoEgzSpDB
Scale = 1:47.2
1
2
3
4
5
6
7
8
9
16
15
14
13 12 11
10
17
18 19
6x10
6x8
8x10
7x12 M18SHS
5x10 M18SHS
5x6
3x10
5x6
3x4
5x6
4x6
9x10 M18SHS
4x10
2-8-3
2-8-3
5-0-13
2-4-11
7-5-8
2-4-11
11-5-15
4-0-7
14-8-5
3-2-6
18-6-8
3-10-3
-1-6-0
1-6-0
2-8-3
2-8-3
5-0-13
2-4-11
7-5-8
2-4-11
11-5-15
4-0-7
14-8-5
3-2-6
18-6-8
3-10-3
22-7-2
4-0-10
1-2-05-0-07-1-97-2-150-1-62-9-121-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-7-12,0-3-4], [8:0-3-8,0-4-4], [10:Edge,0-3-8], [13:0-6-0,0-3-12], [15:0-3-0,0-1-8], [16:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.87
0.65
0.73
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.29
-0.37
0.15
0.03
(loc)
13
13
10
13
l/defl
>754
>588
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 128 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
7-9: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-16: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-1-3 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=2481/0-5-8 (min. 0-3-6), 10=3236/0-5-8 (min. 0-4-4)
Max Horz 16=129(LC 9)
Max Grav 16=2786(LC 27), 10=3324(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4287/0, 3-4=-6370/0, 4-5=-6756/0, 5-18=-3764/0, 6-18=-3649/0, 6-7=-1855/165,
7-8=-1706/17, 8-19=0/779, 2-16=-2637/3, 8-10=-3320/0
BOT CHORD 15-16=-240/637, 14-15=0/4017, 13-14=0/6160, 12-13=0/6221, 11-12=0/3554
WEBS 3-15=-1372/13, 3-14=0/2217, 4-14=-765/9, 4-13=-17/372, 5-13=0/1359, 5-12=-3236/0,
6-12=0/1294, 6-11=-3019/0, 7-11=0/1297, 2-15=0/3211, 8-11=0/1543
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M2
Truss Type
ROOF SPECIAL
Qty
2
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203210
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:55 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-2PSsMjCpk0CUpcgjNPEvN1ZYKWF6sZKFxabLm6zSpDA
Scale: 1/4"=1’
1
2
3
4
5
6
7
8
9
10
11
20
19
18
17
16
15
14 13
12
21
22 23
6x8
8x10
9x10 M18SHS
4x4
6x6
3x8 M18SHS
5x6
4x10
5x6
3x4
2x4
4x8
5x6
7x10
7x10
9x10 M18SHS
6x8
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
11-5-15
4-8-11
13-6-8
2-0-9
14-8-5
1-1-13
18-6-8
3-10-3
-1-6-0
1-6-0
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
9-1-9
2-4-5
11-5-15
2-4-5
13-6-8
2-0-9
14-8-5
1-1-13
18-6-8
3-10-3
22-7-2
4-0-10
1-2-05-0-07-1-97-2-152-9-121-9-01-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-2-8,0-1-12], [7:0-4-12,0-2-12], [8:0-1-4,0-3-8], [9:0-4-10,Edge], [10:0-3-8,0-4-8], [12:0-3-8,0-0-0], [14:0-7-12,0-5-12], [20:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.81
0.89
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.29
-0.37
0.16
0.03
(loc)
16-17
16-17
12
17
l/defl
>756
>588
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 141 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
9-11: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
8-15,12-14: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-20: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-4 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)20=2481/0-5-8 (min. 0-4-3), 12=3236/0-5-8 (min. 0-5-3)
Max Horz 20=130(LC 9)
Max Grav 20=2786(LC 27), 12=3324(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4001/0, 3-4=-6137/0, 4-5=-6604/0, 5-6=-6503/0, 6-22=-2527/0, 7-22=-2406/0,
7-8=-2490/105, 8-9=-1484/82, 9-10=-1713/17, 10-23=0/779, 2-20=-2640/2,
10-12=-3317/0
BOT CHORD 19-20=-244/518, 18-19=0/3732, 17-18=0/5950, 16-17=0/3770, 8-14=0/2409,
13-14=-104/1870
WEBS 3-19=-1380/10, 3-18=0/2302, 4-18=-910/1, 4-17=0/403, 5-17=-257/47, 6-17=0/3547,
6-16=-2431/1, 7-16=-726/182, 14-16=0/2835, 7-14=-666/48, 8-13=-2085/0, 9-13=0/1139,
2-19=0/3072, 10-13=-58/1594
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M3
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203211
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:56 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-Wc0Ea3DSVKKLRmEvw6l8wF5l6va9b0POAELuIZzSpD9
Scale = 1:48.8
1
2
3
4
5
6
7
8
9
10
11
12
21
20
19
18
17
16
15 14
13
22
23 24
6x8
8x10
7x12 M18SHS
4x4
6x6
5x6
4x10
5x6
3x4
2x4
4x8
5x6
7x10
7x10
5x8
8x8
5x10 M18SHS
5x10 M18SHS
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
11-5-15
4-8-11
13-6-8
2-0-9
14-8-5
1-1-13
18-7-14
3-11-9
18-7-15
0-0-1
-1-6-0
1-6-0
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
9-2-7
2-5-3
11-5-15
2-3-7
13-6-8
2-0-9
14-8-5
1-1-13
16-6-6
1-10-1
18-7-15
2-1-9
22-7-2
3-11-3
1-2-05-0-07-1-97-2-152-8-131-9-01-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-2-8,0-1-12], [7:0-4-12,0-2-12], [8:0-1-4,0-3-8], [10:0-3-5,0-5-2], [11:0-5-0,0-1-12], [15:0-7-12,0-5-12], [18:0-5-12,0-4-0], [21:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.68
0.90
0.67
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.29
-0.37
0.17
0.03
(loc)
17-18
17-18
13
18
l/defl
>754
>586
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 145 lb FT = 0%
GRIP
118/123
113/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
9-12: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
8-16,13-15: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-21: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)21=2502/0-5-8 (min. 0-4-3), 13=3217/0-5-9 (min. 0-5-3)
Max Horz 21=129(LC 9)
Max Grav 21=2799(LC 27), 13=3305(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4028/0, 3-4=-6194/0, 4-5=-6672/0, 5-6=-6571/0, 6-23=-2569/0, 7-23=-2447/0,
7-8=-2550/68, 8-9=-1501/102, 9-10=-1511/137, 10-11=-791/69, 11-24=0/757,
2-21=-2653/1, 11-13=-3034/90
BOT CHORD 20-21=-240/523, 19-20=0/3758, 18-19=0/6005, 17-18=0/3770, 8-15=0/2434,
14-15=-67/1927, 13-14=-377/680
WEBS 3-20=-1389/10, 3-19=0/2327, 4-19=-917/1, 4-18=0/413, 5-18=-268/47, 6-17=-2417/1,
7-17=-739/164, 15-17=0/2887, 7-15=-643/49, 8-14=-1984/0, 9-14=-152/681,
10-14=0/1410, 2-20=0/3092, 10-13=-1502/549, 6-18=0/3603
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M4
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203212
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:58 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-S_8_?kEi1xa3g4OI2Xoc?gB8jjGt3wghdYq?NRzSpD7
Scale = 1:48.8
1
2
3
4
5
6
7
8
9
10
11
12
21
20
19
18
17
16
15 14
13
22
23
24
6x8
8x10
7x12 M18SHS
3x6
8x8
4x8
5x6
4x8
3x4
2x4
4x8
5x6
6x10
8x12
6x8
6x6
4x6
4x8 MT18HS
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
11-5-15
4-8-11
13-6-8
2-0-9
14-8-5
1-1-13
19-4-11
4-8-6
-1-6-0
1-6-0
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
9-1-9
2-4-5
11-5-15
2-4-5
13-6-8
2-0-9
14-8-5
1-1-13
16-10-12
2-2-7
19-4-11
2-5-15
22-7-2
3-2-7
1-2-05-0-07-1-97-2-152-3-01-9-01-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-2-4,0-1-12], [7:0-4-12,0-3-0], [8:0-4-0,0-4-4], [10:0-3-0,0-3-12], [11:0-3-0,0-1-12], [15:0-9-0,0-5-4], [17:0-3-7,0-2-8], [18:0-5-8,0-4-0], [20:0-2-0,0-2-4],
[21:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.48
0.95
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.32
-0.41
0.18
0.03
(loc)
17-18
17-18
13
18
l/defl
>723
>560
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 145 lb FT = 0%
GRIP
118/123
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
9-12: 1.5X7.25 Microllam LVL 2.0E TG
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
8-16,13-15: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-21: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-10-1 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)21=2625/0-5-8 (min. 0-4-5), 13=3108/0-5-9 (min. 0-5-0)
Max Horz 21=123(LC 9)
Max Grav 21=2872(LC 27), 13=3192(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4183/0, 3-4=-6526/0, 4-5=-7090/0, 5-6=-6986/0, 6-23=-2829/0, 7-23=-2705/0,
7-8=-2911/0, 8-9=-1780/5, 9-10=-1852/7, 10-11=-554/45, 11-24=0/621, 2-21=-2724/0,
11-13=-2305/58
BOT CHORD 20-21=-221/550, 19-20=0/3907, 18-19=0/6329, 17-18=0/4119, 8-15=0/2607,
14-15=0/2221, 13-14=-210/958
WEBS 3-20=-1442/8, 3-19=0/2471, 4-19=-978/0, 4-18=0/496, 6-18=0/3679, 6-17=-2510/0,
7-17=-957/50, 15-17=0/3186, 7-15=-566/51, 8-14=-2027/6, 9-14=-50/940, 10-14=0/1150,
2-20=0/3208, 10-13=-1698/178
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M5
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203213
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:13:59 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-wBiMC4FKoFiwIEzUcFJrYtjIt7bNoMdqsCZZvuzSpD6
Scale = 1:48.8
1
2
3
4
5
6
7
8
9
10
11
12
21
20
19
18
17
16
15 14
13
22
23
24
6x8
8x10
9x10 M18SHS
4x6
8x8
4x8
5x10
4x8
3x4
2x4
4x8
6x6
8x8
8x12
6x8
4x6
4x6
4x8 MT18HS
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
11-5-15
4-8-11
13-6-8
2-0-9
14-8-5
1-1-13
20-1-6
5-5-1
-1-6-0
1-6-0
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
9-1-9
2-4-5
11-5-15
2-4-5
13-6-8
2-0-9
14-8-5
1-1-13
17-3-2
2-6-13
20-1-6
2-10-4
22-7-2
2-5-12
1-2-05-0-07-1-97-2-151-9-21-9-01-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [6:0-2-4,0-1-12], [7:0-5-0,0-3-0], [8:0-4-0,0-4-4], [9:0-3-12,0-3-0], [11:0-3-0,0-1-12], [15:0-8-12,0-5-8], [17:0-2-7,0-2-8], [18:0-5-0,0-5-0], [21:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.52
1.00
0.71
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.34
-0.44
0.20
0.03
(loc)
17-18
17-18
13
18
l/defl
>693
>534
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 141 lb FT = 0%
GRIP
197/144
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
9-12: 2x8 SPF 1950F 1.7E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
8-16,13-15: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-21: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)21=2740/0-5-8 (min. 0-4-6), 13=3008/0-5-9 (min. 0-4-14)
Max Horz 21=116(LC 9)
Max Grav 21=2941(LC 27), 13=3090(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4327/0, 3-4=-6833/0, 4-5=-7474/0, 5-6=-7365/0, 6-23=-3067/0, 7-23=-2941/0,
7-8=-3243/0, 8-9=-2045/0, 9-10=-2242/0, 10-11=-459/15, 11-24=0/487, 2-21=-2791/0,
11-13=-1784/28
BOT CHORD 20-21=-206/576, 19-20=0/4045, 18-19=0/6628, 17-18=0/4394, 8-15=0/2761,
14-15=0/2492, 13-14=-35/1325
WEBS 3-20=-1491/7, 3-19=0/2604, 4-19=-1031/0, 4-18=0/569, 6-18=0/3784, 6-17=-2571/0,
7-17=-1140/0, 15-17=0/3461, 7-15=-491/54, 8-14=-2091/11, 9-14=0/1230, 10-14=0/888,
2-20=0/3316, 10-13=-2046/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M6
Truss Type
ROOF SPECIAL
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203214
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:01 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-sZp7dmHaKsyeXY7tjgLJdIpevwJWGGw7JW2fzmzSpD4
Scale = 1:50.7
1
2
3
4
5
6
7
8
9
10
11
12
21
20
19
18
17
16
15 14
13
22
23
24
6x12 MT18HS
8x10
9x10 M18SHS
4x6
8x8
4x6
4x8
3x8
3x4
2x4
4x8
6x6
8x10
8x12
6x8
4x8
3x12
6x6
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
11-5-15
4-8-11
13-6-8
2-0-9
14-8-5
1-1-13
20-4-7
5-8-2
20-10-2
0-5-11
-1-6-0
1-6-0
2-5-7
2-5-7
4-7-5
2-1-15
6-9-4
2-1-15
9-1-9
2-4-5
11-5-15
2-4-5
13-6-8
2-0-9
14-8-5
1-1-13
17-7-7
2-11-3
20-10-2
3-2-11
22-7-2
1-9-0
1-2-05-0-07-1-97-2-151-3-51-9-01-10-64.00 12
8.00 12
3.00 12
Plate Offsets (X,Y)-- [3:0-2-4,0-1-12], [6:0-2-0,0-1-12], [7:0-5-0,0-3-0], [8:0-3-12,0-4-4], [11:0-3-0,0-2-12], [15:0-8-8,0-5-12], [18:0-4-12,0-5-8], [19:0-2-0,0-1-8], [20:0-2-12,0-2-0],
[21:0-5-0,0-6-4]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.55
0.83
0.72
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.36
-0.46
0.21
0.04
(loc)
17-18
17-18
13
18
l/defl
>689
>530
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
MT18HS
Weight: 142 lb FT = 0%
GRIP
197/144
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
7-9: 2x6 SPF 2100F 1.8E, 9-12: 2x8 SPF 1950F 1.7E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
18-21: 2x6 SPF 2100F 1.8E, 8-16: 2x4 SPF 1650F 1.5E
13-15: 2x4 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
2-21,11-13: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 20-21,15-16.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)21=2835/0-5-8 (min. 0-3-10), 13=2926/0-5-9 (min. 0-3-13)
Max Horz 21=111(LC 9)
Max Grav 21=2998(LC 27), 13=3004(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4432/0, 3-4=-7077/0, 4-5=-7780/0, 5-6=-7660/0, 6-23=-3268/0, 7-23=-3138/0,
7-8=-3514/0, 8-9=-2254/0, 9-10=-2595/0, 10-11=-929/75, 11-24=0/371, 2-21=-2828/0,
11-13=-1732/0
BOT CHORD 20-21=-195/640, 19-20=0/4159, 18-19=0/6869, 17-18=0/4621, 8-15=0/2867,
14-15=0/2701, 13-14=0/1843
WEBS 3-20=-1538/5, 3-19=0/2715, 4-19=-1086/0, 4-18=0/623, 6-18=0/3851, 6-17=-2618/0,
7-17=-1278/0, 15-17=0/3681, 7-15=-445/153, 8-14=-2061/14, 9-14=0/1378,
10-14=-43/660, 10-13=-1968/0, 2-20=0/3358
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
M7
Truss Type
JACK-CLOSED
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203215
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:01 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-sZp7dmHaKsyeXY7tjgLJdIpfIwT3GGB7JW2fzmzSpD4
Scale = 1:29.0
1
2
3
4
5
7
6
8
5x5
5x6
4x8
4x6
4x4
3x6
5-8-0
5-8-0
10-11-13
5-3-13
-1-6-0
1-6-0
5-8-0
5-8-0
10-11-13
5-3-13
1-2-04-9-154.00 12
Plate Offsets (X,Y)-- [2:0-4-15,0-2-2], [5:Edge,0-3-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.46
0.15
0.77
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.03
-0.04
0.01
0.00
(loc)
7
7
6
7
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
Weight: 70 lb FT = 0%
GRIP
118/123
LUMBER-
TOP CHORD 2x6 SPF 2100F 1.8E
BOT CHORD 1.5X7.25 Microllam LVL 2.0E TG
WEBS 2x4 SPF 1650F 1.5E *Except*
4-7: 2x4 WW Stud
SLIDER Left 2x4 WW Stud 2-11-4
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)6=1276/0-3-8 (min. 0-1-8), 2=1672/0-5-8 (min. 0-1-12)
Max Horz 2=104(LC 7)
Max Uplift2=-10(LC 6)
Max Grav 6=1645(LC 15), 2=1948(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-8=-2397/0, 3-8=-2186/0, 3-4=-1853/0, 4-5=-342/131, 5-6=-644/18
BOT CHORD 2-7=0/1903, 6-7=0/1903
WEBS 4-6=-2031/7
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint 2.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
N1GD
Truss Type
ROOF SPECIAL GIRDER
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203216
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:02 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-LmNVq6HC5A4V9hi3HNsYAWLqGKhQ?lUHYAoDWCzSpD3
Scale = 1:49.4
1 2
3
4
5
6
7
8
9
15 14 13 12
11 1016
17
18
6x6
6x12 MT18HS
10x10
5x5
10x12
8x12
5x8
4x10
2x4 3x4
4x4
6x10
8x8
5x12
5x12
2x4
4-1-0
4-1-0
7-10-9
3-9-8
11-8-1
3-9-8
14-11-15
3-3-14
16-9-5
1-9-6
21-3-9
4-6-4
21-3-10
0-0-1
-1-6-4
1-6-4
4-1-0
4-1-0
7-10-9
3-9-8
11-8-1
3-9-8
14-10-14
3-2-13
16-9-5
1-10-7
21-3-10
4-6-5
22-11-1
1-7-7
1-2-05-0-07-1-81-2-11-9-03.94 12
7.88 12
Plate Offsets (X,Y)-- [3:0-1-12,0-2-4], [5:0-3-0,0-4-0], [6:0-4-8,0-3-0], [7:0-1-12,0-4-4], [8:Edge,0-6-15], [11:0-3-0,0-5-4], [13:0-1-8,0-2-8]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
3-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.44
0.66
0.63
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.18
-0.23
0.09
0.02
(loc)
14
13-14
8
14
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
MT18HS
Weight: 152 lb FT = 0%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x6 SPF 2100F 1.8E *Except*
5-6: 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E *Except*
2-12: 2x6 SPF 2100F 1.8E
WEBS 2x4 SPF 1650F 1.5E *Except*
11-13: 2x4 SPF 2100F 1.8E
SLIDER Left 2x6 SPF 1650F 1.5E 4-2-10, Right 2x6 SPF 1650F 1.5E 5-4-0
BRACING-
TOP CHORD 2-0-0 oc purlins (3-6-9 max.)
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)2=4356/0-5-8 (req. 0-5-13), 8=4414/0-5-7 (req. 0-7-1)
Max Horz 2=148(LC 7)
Max Grav 2=4567(LC 27), 8=4509(LC 29)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-7091/0, 3-4=-6351/0, 4-17=-5025/0, 5-17=-4805/0, 5-6=-4440/0, 6-7=-4109/0,
7-8=-5145/0
BOT CHORD 2-15=0/6050, 14-15=0/6050, 13-14=0/5915, 12-13=0/435, 6-11=0/3296, 10-11=0/3567,
8-10=0/3567
WEBS 3-14=-540/104, 4-14=0/402, 4-13=-2299/16, 5-13=-1063/20, 11-13=0/4739,
5-11=-1627/39, 7-11=-901/283, 7-10=0/288
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) WARNING: Required bearing size at joint(s) 2, 8 greater than input bearing size.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
O1GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203217
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:04 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-H8VFFoJTcnLDO?sROou0FxR488NMTgrZ?UHJa5zSpD1
Scale = 1:44.7
1
2
3
4
5
6
11 10 9 8 712131415
6x6
7x10
5x10 M18SHS 5x10 M18SHS
3x6
8x8 8x8
3x6
8x8
8x8
4-0-0
4-0-0
7-11-0
3-11-0
12-0-0
4-1-0
15-4-8
3-4-8
-2-10-0
2-10-0
4-0-0
4-0-0
7-11-0
3-11-0
12-0-0
4-1-0
15-4-8
3-4-8
1-10-47-1-92-1-158.00 12
Plate Offsets (X,Y)-- [2:0-5-0,Edge], [7:Edge,0-5-8], [8:0-3-8,0-4-12], [9:0-4-0,0-4-12], [10:0-3-8,0-4-12], [11:0-0-0,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
5-0-0
1.00
1.00
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.80
0.69
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.08
-0.10
0.02
0.00
(loc)
8-9
8-9
7
10
l/defl
>999
>999
n/a
>999
L/d
360
180
n/a
240
PLATES
MT20
M18SHS
Weight: 312 lb FT = 0%
GRIP
169/123
197/144
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
4-9,2-10,6-8: 2x4 SPF 1650F 1.5E, 2-11,6-7: 2x6 SPF 1650F 1.5E
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 10-11.
REACTIONS.(lb/size)11=12800/0-5-8 (req. 0-6-11), 7=11680/Mechanical
Max Horz 11=345(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=0/973, 2-3=-10255/0, 3-4=-8480/0, 4-5=-8532/0, 5-6=-9857/0, 2-11=-11582/0,
6-7=-10031/0
BOT CHORD 11-12=-1221/433, 10-12=-1221/433, 10-13=0/7816, 9-13=0/7816, 9-14=0/7700,
8-14=0/7700, 8-15=0/1069, 7-15=0/1069
WEBS 3-10=-832/434, 3-9=-1438/200, 4-9=0/6272, 5-9=-1229/52, 5-8=-930/258, 2-10=0/8281,
6-8=0/7648
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 100.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) WARNING: Required bearing size at joint(s) 11 greater than input bearing size.
10) Refer to girder(s) for truss to truss connections.
11) Provide metal plate or equivalent at bearing(s) 7 to support reaction shown.
12) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1865 lb down at 2-0-12, 1865 lb
down at 4-0-12, 1865 lb down at 6-0-12, 1865 lb down at 8-0-12, 2105 lb down at 10-0-12, and 2105 lb down at 12-0-12, and 2105
lb down at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) StandardContinued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
Job
03047-15
Truss
O1GD
Truss Type
COMMON GIRDER
Qty
1
Ply
3
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203217
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:04 2015 Page 2 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-H8VFFoJTcnLDO?sROou0FxR488NMTgrZ?UHJa5zSpD1
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-2=-550, 2-4=-550, 4-6=-550, 7-11=-50
Concentrated Loads (lb)
Vert: 10=-1865(F) 9=-1865(F) 8=-2105(F) 12=-1865(F) 13=-1865(F) 14=-2105(F) 15=-2105(F)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
Job
03047-15
Truss
V1G
Truss Type
GABLE
Qty
1
Ply
1
DW Dantas/Snowberry/#03047-15
Job Reference (optional)
R44203218
7.620 s Mar 27 2015 MiTek Industries, Inc. Wed Apr 08 08:14:05 2015 Page 1 Alpine Truss, Montrose, CO - 81401
ID:x7ib?IZndOJQ8rR3jNe0IjzbMga-lK3eT8K5N5T309QeyVQFn8zQvYtQCCvjE80t6XzSpD0
Scale = 1:32.6
1
2
3
4
5
6
7
8
9
17 16 15 14 13 12 11 10
18 19
3x4
5x6
3x4
3x4 2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
19-9-14
19-9-14
9-10-15
9-10-15
19-9-14
9-10-15
0-0-43-5-110-0-45.00 12
LOADING (psf)
TCLL
(Roof Snow=100.0)
TCDL
BCLL
BCDL
100.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
(Matrix)
0.10
0.06
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
9
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 59 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
OTHERS 2x4 WW Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 19-9-14.
(lb) - Max Horz 1=24(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 16, 17, 11, 10
Max Grav All reactions 250 lb or less at joint(s) except 1=283(LC 14), 9=283(LC 15), 14=340(LC 1), 15=485(LC
14), 16=407(LC 14), 17=727(LC 14), 13=485(LC 15), 11=407(LC 15), 10=727(LC 15)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 5-14=-311/0, 4-15=-448/16, 3-16=-392/20, 2-17=-652/27, 6-13=-448/14, 7-11=-392/21,
8-10=-652/27
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=100.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 17, 11, 10.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 7777 Greenback Lane
Suite 109
Citrus Heights, CA 95610
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE.
April 8,2015
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 02/16/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBS