Loading...
HomeMy WebLinkAboutB15-0053_B15-0053 Special Inspection Steel Report_1454345940.pdf. KRM CONSULTANTS, INC. P.O. Box 4572 • Vall, Colorado 81658 • 97()..949-9391 Date· 401 Beaver Dam Circle ·· Addition Mark Newman 11/09/15 '-PresentaiSite·' Dennis & Paul (ShaefferHyde) FIELD REPORT "Job Numoer> .·. 1407-136 .: ·.: . Amve .·. . , . · 9:oo am Depart< . : 10:15 am Status of· •. · •· Comoletlon. · 803 Framing ~l'!'~IJll Eleme~:o __ b~f!tr.vi!d ·: .:. _ .. .. · :· sheet -· --A-~~·-···-··~--~-····--·---·------1------'-----'"---'-------...._---~--.,,-,--·-· -··---'..,..,...,, .. ~-~--· ._ •. _...,..........._._-'-'-,_, ___ .;.....;....···--!. I 53-B, S4-B, 55-B I I I 1. Framing Plans 2. Low Roof and Brace not present at time of visit 3. Storage in garage has 2x8 ledger attached with (3}-8D nails at 16" o.c. into each stud. This is acceotable. S3-B, S4-B, S5-B 4. 5. .. oeflclencies ·observed:-· ., :_ . -~ ..... ; ... :· 1. Simpson Twist Strap at 6x12 on sheet S3-B not present 2. Double 2x10 interior header required at closet door Bedroom 3 3. 4. 5. ACtion R«iulred ··. . 1. Simpson Twist Strap was installed while on site 2. Double 2x10 interior header at closet door Bedroom 3 was installed while on site 3. 4. 5. Do deficiencies require follow-up structural observation? I 53-B I I Photo Ref· Detail I I ! Yes D No fZI Other than any deficiencies noted, are the structural elements observed in general conformance with KRM Consultants, Inc. approved plans and specifications? ·ves l:il:I No 0 SIGNED: COPY TO: / A£. ff~.7~~ Mark T. Newman / HEPWORTH-PAWLAK GEOTECHNICAL ·-·----·-·---·-··-------------- 5020 County Road 154 Glenwood Springs, CO 81601 Phone: 970-945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com REINFORCEMENT STEEL INSPECTION REPORT Client: Jim and Carol Schmidt 3901 South Gilpin Street Job No.: 113 405A Day: Monday Cherry Hills Village, Colorado 80113 Date: 9/28/185 Page: 1 of 1 Project: Proposed Residence, Lot 2, Block 4, Vail Valley Third Filing, 401 Beaver Dam Circle, Vail, Colorado Area of Inspection: Anchor bolts for garage roof piers Reference Documents Structural drawings Used: Inspection Notes: Holes were minimum of 6" deep, clean and free of debris prior to installation of Powers AC100 + Gold & Bolts Inspection Status: D Preliminary [gl Final 181 Concrete reinforcement as noted above was judged to be in reasonable conformance with the referenced construction documents. D Exceptions Noted: Verbal Communication: Distribution: Paul with Shaeffer Hyde was informed of our inspection Shaeffer Hyde Construction -Paul Sisneros (paul@asconco.com) Justin Orgill Steven L. Pawlak, P.E. Field Technician Reviewed By /ksw •. West Slope Testing & Inspection LLC Report#! 3177 Glendam Dr. Grand Junction, CO 81504 Phone:97()..434-6988 Cell: 970-260-2844 Page 1 of l Inspection Report Date: 9-9-15 Client: HP Geotech (Job #HP 113 405A) Project: Unit B 401 Beaver Dam Circle Address: 401 Beaver Dam Circle Unit B Vail, CO Building Permit No: BlS-0053 General Contractor: Shaeffer Hyde Construction Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding at wood floor joist hangers to top of steel beam upper level framing. Also inspected high strength A325 bolting at steel beam connection upper level framing. Note no special inspection was performed at the shop welded angle clips. To the best of my knowledge this completes the special inspections of the structural steel onsite welding & high strength A325 bolting on the project, as outlined above. + Douglas E Young CWI 96070131 OC1 EXP. 711/2017