HomeMy WebLinkAboutB15-0106_A-5.2_1438291200.pdfback to back 3"X6"X1/4" X 0-6" steel angles with
(2) 1/2" X 5" MB's. ea. side
3/8" X 2 1/2" steel bar verticals
at max. of 4' oc.
sandwich between angles and weld
1/4" X 1 1/2" horiz. bars, weld
to vertical stl. bars
2X6 clear cedar cap
1/4" X 2 1/2" X 0-4"cap plate
w/ 4 #10 X 1 1/2" screws
2X6 synthetic deck
on dbl. 2X10
rim
1X12 cedar fascia
A-5.2
sheet no.
date:
project:
revisions:
1404
piper / architecture, ltd.
box 5560 avon, colorado 81620
970-949-7074 dpiper@vail.net
BARNEY
RESIDENCE
5074 MAIN
GORE
DRIVE, UNIT AVAIL, COLORADO 4.6.15 permit
1.2.15 prelim
1.26.15 DRB
2.4.15 DRB rev.
Deck Section above Lower Level Bedrooms
1 1/2" = 1'-0"
2X decking on
tapered sleepers
EPDM waterproof membrane w/
protection board on 3/4" t&g plywood
2X12's w/ taper rip
re: struct. dwgs. for
spacing
3/4"
1'-0"
3/4"typical
2X6 treated studs @ 16" oc.
w/ 5/8" exterior plywd.
2 coat stucco on building
paper both sides
20 ga. metal cap, painted
1 1/2"
new asphalt drive
at removed cribbing planter
typical railing beyond
stucco wall to east
07/30/15