HomeMy WebLinkAboutB15-0106_A-7.1_1438291200.pdfD
5'-4"
6'-0" 3'-0"
5'-4"
A
E
3'-0 1/4"
2'-4"
2'-6"
4'-0"
5'-0"
7'-11 3/8" 10'-2"
1'-6"
4'-0" 3'-0" 3'-0"
2'-4"
4'-0"6'-0" 3'-0"
2'-6"
1'-6"
4'-0"
3'-6" 3'-0"
7'-0"
3'-0"
1'-6"
1'-6"
4'-0"
B
C
G F
M L
I
H
J
J K
NOTES:
WINDOWS SHALL BE METAL CLAD WHITE FINISH.
INTERIOR WOOD SHALL BE CLEAR PINE OR FIR.
PROVIDE SCREENS FOR ALL OPERATING SASHES. COLOR TO BE
SELECTED LATER.
GLAZING SHALL BE CLEAR, LOW E, DOUBLE PANE INSULATING.
VERIFY CODE REQUIREMENTS FOR ANY TEMPERING OF GLAZING.
"DS" INDICATES DIRECT SET
REFER TO BUILDING ELEVATIONS, SOME LETTERED WINDOWS
OCCUR MULTIPLE TIMES.
WINDOW UNITS MUST MEET A PERFORMANCE U FACTOR OF
.32 OR LESS.
DS
DS DS
DS
DS
DSDS
DS
DS DS
DS
EGRESS
WINDOWS
1/2" = 1'0"
4.6.15 permit
A-7.1
sheet no.
date:
project:
revisions:
1404
piper / architecture, ltd.
box 5560 avon, colorado 81620
970-949-7074 dpiper@vail.net
BARNEY
RESIDENCE
5074 MAIN
GORE
DRIVE, UNIT AVAIL, COLORADO 12.12.14 prelim
1.5.15 prelim
2'-6" 2'-6"
DS DS
N
3'-0"
4'-0"4'-0"
4'-0"
FINISH NOTES
1. R & S AND OR DOT-DASH LINE INDICATES ROD AND SHELF.
SHELF TO BE WHITE MILAMINE HIGH DENSITY PARTICLE BD. WITH 5/4 X 3/4 OAK NOSING.
ROD TO BE 1 3/8” WOOD DOWEL WITH SUPPORT BRACKETS AT 4’-0” OC. MAX.
2. TUB/SHOWERS AND SHOWERS TO BE 1/2 ” CEMENT BOARD WALL SUBSTRATE.
3. UNDERLAYMENT TO FLOOR TILE AT PLYWOOD SUB-FLOOR SHALL BE SCHLUTER UNDERLAYMENT .
4. MECHANICAL ROOM AND GARAGE TO RECEIVE 5/8” FIRE RATED GYPSUM BOARD WITH FULL TAPE AND FINISH.
FIRE TAPE CHIMNEY CHASE .
5. WALLS AND CEILINGS SHALL BE 5/8” GYPSUM BOARD (UNLESS NOTED OTHERWISE) WITH SQUARE CORNERS.
FINISH TO BE SKIP TROWEL WITH WIPE OVER. PROVIDE SAMPLE FOR OWNER'S REVIEW.
6. BASE TRIM SHALL BE 5 1/4" x 3/4" PAINT GRADE PINE W/ CHAMFER TOP.
8. DOOR TRIM TO BE SQUARE CORNER BEAD GYPSUM BOARD.
9. WINDOW TRIM TO BE SQUARE CORNER BEAD GYPSUM BOARD WITH 5/4" PAINT GRADE PINE. EXTEND 1 1/4"
BEYOND WALL FACE.
10. SHOWER DOORS (UPPER AND MAIN LEVEL) TO BE 3/8" TEMPERED FRAMELESS STYLE. LOWER TUB/SHOWER
CURTAIN ROD.
11. INTERIOR DOORS ARE TO BE FLUSH SOLID CORE 1 3/4" X 6'8" H. X NOTED WIDTH OAK,
STAINED AND SEALED. DOOR CASING TO BE PINE, PAINTED. VERIFY HINGE FINISH.
1.26.15 DRB
1X prefinished trim to soffit
tempered, insulated
glass sidelite
1X prefinished trim to
inside corner
1X prefinished trim to
outside corner
3-0 X 8-0 X 1 3/4" wood
solid core prehung door
ext. threshold and
weatherseal
verify hardware,
predrill
Entry Door and Sidelite
scale = none
6'-0"
2'-0" 4'-0" O P O
9'-0"
3'-0" 3'-0" 3'-0"
07/30/15