HomeMy WebLinkAboutB15-0106_Helical Pier signed_1434456960.pdf I,..I Hepworth-Paw Zak Geotechnical, Inc. �h 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 HEPWORTH-PAWLAK GEOTECHNICAL FIN: 970-945-845 } email: hpgeo,3hpgeotech.enu June 12, 2015 Michael Barney 5074 Main Gore Drive, Unit A Vail, Colorado 81657 tandmbamev a,comcast.net Job No. 115 168A Subject: Observation of Excavation and Helical Pier Installation, Proposed Additions to Unit A Residence, Lot 5, Filing 1, Vail Meadows, 5074 Main Gore Drive, Vail, Colorado Dear Mr. Barney: As requested by Wayne Haskins, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the excavations at the subject site on June 4 and 8, 2015 to evaluate the soils exposed for foundation support. We subsequently observed helical pier installation designed to support the western portion of the garage addition on June 11, 2015. The findings of our observations and recommendations are presented in this report. The services were supplemental to our proposal for geotechnical engineering services to you, dated April 2, 2015. The proposed construction is similar to that discussed in our previous report. The additions will be attached to the north (bedrooms), to the west (garage) and to the south (new entryway) sides of the existing building. The additions have been designed to be supported on spread footings using an allowable soil bearing pressure of 2,500 psf based on recommendations provided in our previous report. At the time of our June 4 site visit, the foundation excavation for the new entryway and bedrooms was underway. The excavations had been cut at several levels from about 3 to 51/2 feet below the adjacent ground surface. There were minor cuts in the proposed floor slab areas. The excavation subgrades were about 1 foot below the existing residence spread footing bearing elevation. The soils exposed in the bottom of the excavations consisted of medium dense, silty sandy gravel with cobbles. Groundwater was being encountered in the excavations typically flowing out from under the existing building footings. At this time we recommended the excavations be dewatered by shallow trenches leading to sumps (placed outside of footing areas) where the water could be collected and pumped. Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 Michael Barney June 12, 2015 Page 2 On June 8, we observed the west side (garage area) addition excavation to have been cut at several levels from about 3 to 4% feet below the adjacent ground surface The soils exposed in the bottom of the excavation consisted primarily of medium dense, silty sandy gravel with cobbles. Along the west wall line adjacent the creek there was about 4 to 5 feet of old fill and topsoil overlying the natural coarse granular soils. No free water was encountered in this excavation. At this time we recommended the fill and topsoil be removed to bear the footings entirely on the natural coarse granular soils or a relatively deep foundation system such as helical piers be used to penetrate the fill and topsoil and support the foundation wall. On June 11, we observed the installation of 4 helical piers at the site for the garage addition on the west side of the residence. The piers were located on the west wall line and numbered from Pier #1 (at the northwest corner) south to Pier #4 (at the southwest corner). The piers were designed for allowable (working) capacities of 10 to 15 kips. Our observation of the helical pier installation is provided on the attached Report of Helical Pier Observation. The piers were installed in into the granular natural soils at depths from about 7 to 11 feet (11 to 16 feet depth) where refusal to torque or penetration was encountered. The excavation subgrade soils to the east of the west wall line where the piers were installed consisted of the natural coarse granular soils. The piers should have adequate capacity to support the 10 to 15 kip design working loads. The natural coarse granular soil conditions exposed in the excavations are consistent with those previously encountered on the site and suitable for support of spread footings designed for the recommended allowable bearing pressure of 2,500 psf. There could be some differential settlement for the addition areas with respect to the existing structure, and between the spread footings and helical pier supported foundation areas which should be considered in the design. Prior to the footing construction all loose disturbed soils should be removed in the footing areas to expose the undisturbed natural granular soils and the subgrade compacted as feasible. The water seepage into the excavations should continue to be collected and diverted away from the footing areas and any softened soils and mud removed before concrete placement. A shallow depth (6 to 12 inches) of screened rock can be placed in the bottoms of the excavations to aid in the dewatering. Other recommendations presented in our previous report which are applicable should also be observed. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and the previous limited subsurface exploration at the site. Variations in the subsurface conditions below the excavation could increase the risk of foundation movement. We should be advised of any Job No. 115 168A CSC Ugtech Michael Barney June 12, 2015 Page 3 variations encountered in the excavation conditions for possible changes to recommendations contained in this letter. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH — PA G 9611101WICAL, INC. • �i 2 fa / G2e David A. Young, P. E. �.ptV...2j6 GG'' 1.5 DAY/ksw ��p;�� ,`��� qw/o/ilI u0lN,��� attachment 6-11-15 Report of Helical Pier Observation cc: Piper Architects — Duane Piper (dpiperAvail.net) Wayne Haskins Construction — Wayne Haskins (wavne wavnehaskinsconstruction.corn) KRM Consultants — Tim Hennum (tdhRkrmconsultants.com) Job No. 115 168A Gertech I-I P 5020 County Road 154 Glenwood Springs, CO 81501 Phone: 970-945-7988 Fax: 970-945-8454 HEPWORTH-PAWLAK GEOTECHNICAL hpgeo(RhPueotech.com Report of Helical Pier Observation Client: Michael Barney Job No.: 115 168A Date: June 11, 2015 5074 Main Gore Drive, Unit A Sheet No.: 1 of 1 Vail, Colorado 81657 Project: Observation of Excavation and Helical Pier Installation, Proposed Additions to Unit A Residence, Lot 5, Filing 1, Vail Meadows, 5074 Main Gore Drive, Vail, Colorado General Contractor: Wayne Haskins Construction Helical Pier Contractor: Great Divide Pier Manufacturer: Heli-Pile Rig Type: 5K Hand Held Helix Total Design Pier Design Pier Ultimate Measured Pier Pier Shaft Diameter Depth Load Load Load Refusal Number of it Location Type p Capacity Capacity Criteria Torque Shear Pins (m') MO (IdPs) (APs) (APs) (ft-lbs) 1 Northwest 11/2" sq 8" single 11' 10 10 20 P N/A 4 Corner 2 2"a from 11/2" sq 8" single 15' 15 15 30 P N/A 6 North 3 3r° from 11/2" sq. 8" single 14'h' 15 15 30 P North N/A 6 4 Southwest 11/2„ sq 8" single 16' 10 10 20 T N/A 4 corner Preliminary Observations and / or Testing Results Verbally Reported To: Notes: P = Refusal to penetration of pier. T = Refusal by torque limit. All helices lh-inch in thickness. Torque measurements are based on shear pins provided by Great Divide Construction. Design Loads were provided by KAM Consultants Pier Design Load Capacity is based on the measured torque and a safety factor of 2.0. H-P Geotech was requested to observe pier installation. H-P Geotech did not provide pier or helix sizing. Four shear pins = 20 kips (5 kips per pin) Copies: Piper Architects—Duane Piper(doiperAvail.net) Wayne Haskins Construction— Wayne Haskins (wavne a,wavnehaskinsconstruction.com) KRM Consultants— Tim Hennum (tdh@knnconsultants.com) Joe Benedict David A. Young, P.E. Field Observer Reviewed By /ksw