HomeMy WebLinkAboutB15-0132_E-200 LIGHTING PLAN_1431364740.pdfS
S
S
S
S
S
S
N
N
N
N
N
N
N
N N
R
N
N
N
N
N
N
N
S3
N 3 3
N
N
1
1
N
7
1
7
3 7
2
1
7
2
3
6
3
S
S
LC
LC
N
N
R
R R
LC
R
3
CONNECT TO LIGHTING
CONTROL THIS AREA
NOTES:
CIRCUITRY SHOWN IS FOR CONTROL INTENT ONLY. ENSURE
CIRCUIT CONTINUITY TO ALL LIGHTING THAT IS EXISTING TO
REMAIN AND MAY BE AFFECTED BY DEMOLITION / REMODEL.
3
4
8
8
N
R 9
N N
N
N
N
9
GENERAL NOTES - LIGHTING
DETAIL NOTES - LIGHTING LEGEND - LIGHTING
DECORATIVE PENDANT
1 CONNECT NEW LUMINAIRES TO EXISTING LIGHTING CONTROL
PANEL. COORDINATE FIXTURE SPECIFICATION WITH OWNER AND
IF LUMINAIRES ARE TO BE PROVIDED BY OWNER OR ELECTRICAL
CONTRACTOR.
REMOVE EXISTING SWITCH. ENSURE CIRCUIT CONTINUITY TO
LUMINAIRES THAT MAY BE AFFECTED BY DEMOLITION WORK.
CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS THIS
AREA.
EXISTING PENDANT TO BE RELOCATED AS SHOWN.
NOT USED.
PROVIDE NEW CLOSET LIGHT AND DOOR-JAMB SWITCH TO
MATCH EXISTING.
CONNECT TO EXISTING 120V. LIGHTING CIRCUIT THIS AREA.
EXISTING LUMINAIRE TO BE RELOCATED TO NEW LOCATION AS
SHOWN. RE-CIRCUIT AS SHOWN.
EXISTING LUMINAIRE AT THIS LOCATION TO BE RELOCATED AS
SHOWN. PROVIDE NEW LUMINAIRE AT THIS LOCATION.
RE-CIRCUIT AS SHOWN.
2
3
1. COORDINATE ALL LOCATIONS OF LUMINAIRES AND WALLBOX
CONTROLS WITH INTERIOR DESIGNER AND OWNER PRIOR TO
ROUGH-IN.
2. COORDINATE ALL CONTROLS WITH OWNER, INTERIOR DESIGNER,
AND CONTROLS REPRESENTATIVE.
3. VERIFY ALL VOLTAGES AND WATTAGES OF NEW LUMINAIRES PRIOR
TO ROUGH-IN. ENSURE ADDED LUMINAIRES TO EXISTING 120V
BRANCH LIGHTING CIRCUIT DO NOT EXCEED BREAKER CAPACITY
PER NEC.
4. COORDINATE ALL LUMINAIRE SPECIFICATIONS AND DIMMING
REQUIREMENTS WITH LUTRON REPRESENTATIVE PRIOR TO
PURCHASING TO ENSURE LUMINAIRES ARE COMPATIBLE WITH
EXISTING SYSTEM.
5. VERIFY MOUNTING HEIGHTS AND LOCATIONS OF NEW LUMINAIRES
WITH ARCHITECT / INTERIOR DESIGNER PRIOR TOR ROUGH-IN.
6. ALL LUMINAIRES ARE EXISTING TO REMAIN UNLESS OTHERWISE
SHOWN.
7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE
SPECIFICATIONS. COORDINATE WITH INTERIOR DESIGNER FOR
DECORATIVE FIXTURE SPECIFICATIONS.
NOTES:
ALL LIGHTING IS EXISTING TO REMAIN U.O.N.
N = NEW FIXTURE R = RELOCATED
ACCENT/ART LIGHT
CLOSET LIGHT
4
5
6
7
8
9
LIGHTING PLAN
2 of 2
E-200 SCALE: 1/4" = 1'-0"
1
LIGHTING PLAN
ISSUE DATE
UNIT 8203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
c3s
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
c3s
UNIT 8203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Dr. Robert A. Behar
Unit 8203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
f. 212-748-7950
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Worth Interiors
30 BENCHMARK ROAD, SUITE 103
AVON, CO 81920
t. 970-949-9794
eddy@worthinteriors.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
15-27
1
FOR PERMIT
04/17/2015
04/27/15
05/11/15