HomeMy WebLinkAboutB15-0180_A0.04_1435603140.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not
limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any
discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance
with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over
architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location
dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to
installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
WALL SYSTEMS:
RATED ASSEMBLIES (@ MAIN & UPPER LEVELS):
F1-W WOOD PLANK ON EXISTING CONCRETE DECK
Wood plank installed per manufacturer's specifications, over 1 1/2" thick light concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
F1-C TILE ON EXISTING CONCRETE DECK
Tile and pad, installed per manufacturer's specifications, over 1 1/2" thick light weigth concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
C1 GYPSUM BOARD CEILING CONSTRUCTION
(1Hr-Rated) UL DESIGN NO. L521 & UL P533
5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses.
(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.
NOTE: All light fixtures to recieve a Fire Rated Lighting Enclosure, ASTM E-119, UL263
NOTE: Existing steel beams to be protected with a 2-Hr min. fire protection rating.
CEILING SYSTEMS:
FLOOR SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
* Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected.
Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not
evaluated by ICC, 2009 International Building Code requirements and industry recognized trade
standards.
** Interior Walls Studs:
4 - 2x4 Wood Studs
6 - 2x6 Wood Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
Note: All interior walls to Venitian Plaster finish.
NON-RATED ASSEMBLIES (INTERIOR):
W1-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x wood or metal studs at non-bearing walls demising
bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W5- GYPSUM BOARD OVER FURRING
(Non-Rated)
(1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation.
(Re. Structural for size and spacing).
5/8" GYPSUM
WALL BOARD
0'-5 1/2"
W1-6
2X6 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
0'-3 1/2"
W1-4
2X4 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
W1-6e
2X6 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
5/8" EXTERIOR SHEATHING
TYVEK BUILDING WRAP
BOARD AND BATTEN SIDING
TO MATCH EXISTING
INTERIOR
EXTERIOR
NONCOMBUSTIBLE
PENETRATING ITEM
FIRE RATED PENETRATIONS
NONCOMBUSTIBLE
SLEEVE
FIRE RATED WALL
ASSEMBLY
FIRE RATED WALL
NONCOMBUSTIBLE
PENETRATING ITEM
NONCOMBUSTIBLE
SLEEVE
FIRE RATED
CONCRETE OR
MASONRY WALL
FIRE RATED CONCRETE WALL, FLOOR OR CEILING
NONCOMBUSTIBLE
PENETRATING ITEM
NONCOMBUSTIBLE
SLEEVE
FIRE RATED
FLOOR ASSEMBLY
ASSEMBLY
FIRE RATED FLOOR ASSEMBLY
SECTION 714.1.1
UL 2158A
SECTION 714.1.1
UL 2158A
SECTION 714.1.1
UL 2158A
PLAN VIEW
PLAN VIEW
PLAN VIEW
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
141 WEST MEADOW DRIVE
VAIL, CO 81657
A0.04
ASSEMBLIES
SKAAL HUS - UNIT #5
Project Number - 1515
06.01.15
PERMIT SET
1 1/2" = 1'-0"
1
W1-6 - WALL ASSEMBLY
1 1/2" = 1'-0"
2
W1-4 - WALL ASSMBLY
1 1/2" = 1'-0"
3
W1-6e - WALL ASSEMBLY
06/29/15