B15-0190_A130A.1A_1435865520.pdf
5 6 7 H J K J.2 EXISTING PHARMACY EXISTING FAMILY CONSULT EXISTING FIRE PANEL EXISTING OFFICE EXISTING MRI EXISTING MECH EXISTING CONTROL 2'-0" CONCIERGE GIFT SHOP VESTIBULE GIFT SHOP STORAGE LINE OF PROPOSED SCAFFOLDING DIMENSIONS PER 2015 IBC SECTION 3306 WALL CONSTRUCTION TO BE STEEL SCAFFOLD STRUCTURE W/ 3 5/8" METAL STUD FRAMING AND 5/16" CEMENT FIBER SIDING ON INTERIOR AND EXTERIOR FACES. NEW LOCATION OF RELOCATED SLIDING DOOR W/ AUTO OPERATOR RELOCATED WINDOWS 8'-6" 9'-4 3/8" EXISTING CONCRETE SLAB VERIFY DOOR DIMENSIONS 14'-0" MIN.CLEAR SLOPED CONCRETE TOPPING SLAB PROJECT PROTECTION COVERED WALKWAY AND BARRIERS TO BE DESIGNED, ENGINEERED AND PROVIDED BY GENERAL CONTRACTOR; AND SUBMITTED AS A DEFERED SUBMITTAL . RELOCATED SLIDING GLASS DOOR WITH AUTO OPERATOR MULLION MATE EXTEND NEW WALLS TO UNDERSIDE OF DECK, PROVIDE 3/8" METAL STUDS WITH 5/8" GYPSUM WALLBOARD FULL HEIGHT BOTH SIDES TO STRUCTURE ABOVE, PAINT ALL NEW PARTITIONS EXTEND NEW WALLS TO UNDERSIDE OF DECK, PROVIDE 3/8" METAL STUDS WITH 5/8" GYPSUM WALLBOARD FULL HEIGHT BOTH SIDES TO STRUCTURE ABOVE, PAINT ALL NEW PARTITIONS 3/0 7/0, FULL-LITE WOOD DOOR, FINISH TO MATCH EXISTING. KNOCK-DOWN METAL FRAME PAINTED TO MATCH EXISTING. MATCH EXISTING HARDWARE. COORDINATE LOCKING MECHANISM WITH OWNER. 2'-0" PROVIDE NEW AUTO OPERATOR EXISTING DOORS, MATCH EXISTING FINISH EXISTING FLOOR FINISH TO REMAIN NEW RESILIENT BASE ON NEW WALLS REMOVE AND REPLACE FINISHES AS REQUIRED TO MATCH EXISTING CONCIERGE DESK BY OWNER WHEELCHAIR PARKING AREA . EXPANSION JOINT BY GENERAL CONTRACTOR AT WALLS AND ROOF GIFT SHOP MECH (E) MRI (E) FAMILY CONSULT (E) CONTROL (E) OFFICE (E) FIRE PANEL (E) LOBBY/WAITING STORAGE (E) REMOVE SLIDING DOORS, PREP FOR REINSTALLATION EXISTING CASEWORK TO REMAIN EXISTING CASEWORK TO REMAIN REMOVE EXISTING WINDOWS, PREP FOR REINSTALLATION DEMO STOREFRONT, PREP OPENING TO RECEIVE RELOCATED EXISTING SLIDING DOOR SYSTEM. GREETER'S DESK (E) REMOVE EXISTING DOORS AND HARDWARE. EXISTING FRAME TO REMAIN. EXISTING PHARMACY EXISTING FAMILY CONSULT EXISTING FIRE PANEL EXISTING OFFICE EXG STORAGE EXISTING MECH EXISTING CONTROL EXISTING MRI EXG GIFT SHOP TRACK LIGHTS, REMOVE & SAVE FOR REINSTALLATION CROWN MOLDING, EXISTING TO REMAIN REMOVE CROWN MOLDING, SAVE FOR REINSTALLATION EXISTING PHARMACY EXISTING FAMILY CONSULT EXISTING FIRE PANEL EXISTING OFFICE EXG STORAGE EXISTING MECH EXISTING CONTROL EXISTING MRI GIFT SHOP EXISTING CEILING TO REMAIN PEDESTRIAN PROTECTION COVERED WALK WAY TO BE DESIGNED, ENGINEERED, AND PROVIDED BY GENERAL CONTRACTOR; AND SUBMITTED AS A DEFERED SUBMITTAL. EXPOSED STRUCTURE NEW LOCATION OF RELOCATED EXISTING TRACK LIGHTS RE-INSTALL EXISTING CROWN MOULDING REMOVE AND REPLACE PORTIONS OF EXISTING CEILING AS REQUIRED FOR INSTALLATION OF NEW PARTITIONS SUSPENDED LIGHT FIXTURES GENERAL DEMOLITION NOTES: LEGEND: DOOR TO BE REMOVED PARTITION TO BE REMOVED PARTITION AND BORROWED LIGHT WINDOWS TO BE REMOVED 1. DASHED LINES INDICATE ITEMS TO BE REMOVED. DEMOLITION OF WALLS INCLUDES ALL DOORS, WINDOWS AND OTHER ITEMS LOCATED WITHIN THE WALL TO BE REMOVED UNLESS NOTED OTHERWISE. RE: STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR EXISTING UTILITIES 2. FADED LINES INDICATE ITEMS TO REMAIN. 3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONSTRUCTION RELATED CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION. 4. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO DEPARTMENTS OR AREAS THAT ARE IN OPERATION AND SERVED BY SUCH SERVICES. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER. 5. ALL FURNISHINGS AND MOVABLE EQUIPMENT IN DEMOLITION/CONSTRUCTION AREA SHALL BE REMOVED/RELOCATED BY OWNER PRIOR TO START OF DEMOLITION. 6. PATCH CORRIDOR WALLS AND RAILINGS TO MATCH EXISTING ADJACENT CONSTRUCTION, PATCH ALL EXISTING WALLS, CEILINGS AND FLOOR TO REMAIN AFTER DEMOLITION IS COMPLETE. COORDINATE EXTENT OF SELECTIVE DEMOLITION WITH PROJECT SEQUENCING PLANS AND WITH OTHER TRADES. PATCH WALL BOXES AND OTHER WALL/CEILING OPENINGS WHEREVER FIXTURES/OUTLETS ARE BEING REMOVED AND WALLS ARE TO REMAIN. 7. 8. REVIEW DEMOLITION AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH AS-BUILT STRUCTURAL DRAWINGS WHERE POTENTIAL OF ENCOUNTERING LOADED/STRUCTURAL BEAMS/JOISTS/COLUMNS EXIST. 9. 10. CONTRACTOR TO COORDINATE I.C.R.A. (INFECTION CONTROL RISK ASSESSMENT) PLAN WITH OWNER PRIOR TO COMMENCEMENT OF EACH PHASE/SUB-PHASE. 11. DEMOLITION WORK SHALL NOT REDUCE INTEGRITY OF STRUCTURE TO REMAIN NOR OF FIRE- PROOFING/SEPARATION. MAINTAIN STRUCTURAL AND LIFE SAFETY INTEGRITY IN AREAS OF WORK AT ALL TIMES. 12. VERIFY ALL ELECTRICAL AND PLUMBING REQUIREMENTS PRIOR TO REMOVING ANY EQUIPMENT. 13. PROVIDE SIGNAGE FOR TEMPORARY CIRCULATION AND EGRESS PATHS DURING DEMOLITION. 14. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DRAWINGS FOR OTHER DEMOLITION WORK AND WORK TO REMAIN IN PLACE, REQUIRED FOR EACH CONSTRUCTION SEQUENCE. 15. NOTIFY OWNER AND ARCHITECT IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED. ASBESTOS ABATEMENT (OR REMOVAL) TO BE PROVIDED BY OWNER UNDER SEPARATE CONTRACT. COORDINATE WITH GENERAL CONTRACTOR FOR TIMING OF DEMOLITION IN RELATION TO ABATEMENT TO WORK AT EACH CONSTRUCTION SEQUENCE AREA. 16. 17. NOTE THAT SOME SYSTEMS WILL REQUIRE WORK BEYOND CONSTRUCTION SEQUENCE ZONES IN ORDER TO SUPPORT SPACES WITHIN EACH CONSTRUCTION SEQUENCE. COORDINATE THIS WORK WITH GENERAL CONTRACTOR AND OWNER PRIOR TO STARTING WORK OUTSIDE OF CONSTRUCTION SEQUENCE AREA. COORDINATE DEMOLITION/ CONSTRUCTION WORK HOURS, CONSTRUCTION SEQUENCE AND CONSTRUCTION ACCESS WITH OWNER TO MINIMIZE DISRUPTION OF NORMAL DAILY FUNCTION OF OWNER OCCUPIED AREAS. 18. REVIEW DEMOLITION DOCUMENTS WITH OWNER TO VERIFY ANY ITEMS TO BE SALVAGED AND TURNED OVER TO THE OWNER. NOISE DURING DEMOLITION TO BE KEPT TO A MINIMUM. COORDINATE WITH OWNER 72 HOURS PRIOR TO COMMENCEMENT OF PARTICULARLY NOISY WORK SUCH AS CORE-DRILLING. CONTRACTOR TO PROVIDE M.O.P. (METHOD OF PROCEDURE) PRIOR TO COMMENCEMENT OF WORK IN ANY PHASE/SUB-PHASE WHICH AFFECTS HOSPITAL OPERATION. M.O.P.'S TO BE APPROVED BY OWNER AT LEAST 72 HOURS PRIOR TO START OF WORK. DEMOLITION KEY NOTES: 1. REMOVE AND SAVE EXISTING HANDRAIL FOR REINSTALLATION 2. PARTITIONS/ITEMS TO REMAIN REMOVE EXISTING CEILING AS REQUIRED FOR WORK AND REPLACE TO MATCH EXISTING ADJACENT CEILING UPON COMPLETION OF WORK. CONTRACTOR TO COORDINATE EXISTING EQUIPMENT TO BE RELOCATED WITH OWNER. AREA OF LEVEL ONE CEILING DEMOLITION/DISTURBANCE FLOOR PLAN GENERAL NOTES: 1. ALL DIMENSIONS ARE GIVEN TO FINISHED FACE OF SURFACES, CENTERLINES OF DOUBLE DOORS, INTERIOR WINDOWS AND FIXTURES, OR HINGE SIDE OF SINGLE DOORS, U.N.O. 2. WHEN TWO DIFFERENT PARTITION TYPES APPEAR ADJACENT TO EACH OTHER, THEIR FINISHED WALL SURFACES MUST ALIGN UNLESS OTHERWISE NOTED. 3. PARTITION TYPE DESIGNATION SHALL BE CONTINUOUS UNTIL NOTEDOTHERWISE; CHANGES OCCUR AT WALL INTERSECTIONS AND/ORSTRUCTURAL ELEMENTS. 4. WHERE A RATED PARTITION IS INDICATED AND WHERE A RATING HAS BEEN GIVEN TO A FLOOR/DECK ALL PENETRATIONS MUST BE PROPERLY FIRE/SMOKE SEALED WITH A U.L. RATED FIRE STOPPING ASSEMBLY PER THE ASSIGNED RATING REQUIREMENTS. 5. MULLION MATE: WHERE WALL ABUT EXISTING GLASS, PROVIDE ADJUSTABLE PARTITION CLOSURE SYSTEM, MULLION MATE, COMPLETELY INFILL OPENING. SELECT FINISH TO BEST MATCH EXISTING STOREFRONT FRAME, DO NOT PAINT. FIELD VERIFY OPENING SIZE. FOR OPENINGS THAT ARE 2-7/8" MINIMUM TO 3- 15/16" MAXIMUM, PROVIDE MULLION MATE 3. FOR OPENINGS 4" MINIMUM TO 4-15/16" MAXIMUM, PROVIDE MULLION MATE 4. FOR OPENINGS 5" MINIMUM TO 6-15/16" MAXIMUM, PROVIDE MULLION MATE 5. PRE-ASSEMBLED OR SPLICE MULTIPLE UNITS FOR LARGER OPENINGS AND HEIGHTS. 6. 7. MEET OR EXCEED THE PARTITION TYPE REQUIREMENTS INDICATED. PATCH EXISTING FIRE PROOFING AS REQUIRED TO CONFORM TO FIRE RATING REQUIREMENTS. VERIFY EXTENT OF PATCHING. REFLECTED CEILING PLAN LEGEND SUSPENDED CEILING GRID RECESSED DOWN LIGHT DIRECTIONAL RECESSED DOWN LIGHT SUSPENDED GYPSUM BOARD CEILING, UNLESS OTHERWISE NOTED CEILING HEIGHT ABOVE FINISHED FLOOR 2' X 4' GRID MOUNTED LIGHT FIXTURE 2' X 2' GRID MOUNTED LIGHT FIXTURE X'-X" 2x4 2x2 REFLECTED CEILING PLAN GENERAL NOTES CENTER LIGHT FIXTURES IN CEILING PANELS U.O.N CONTEXT EXISTING EXPOSED CONCRETE SPANDREL ASPHALT SHINGLE ROOF FIBER CEMENT PANELS INTERIOR AND EXTERIOR WALL FINISH SIGNAGE BY OTHERS EXISTING BUILDING COVERED WALKWAY BY GC EXPANSION JOINT BY GC RELOCATED EXISTING SLIDING GLASS DOOR SYSTEM 6X6 STEEL ANGLE LEVEL 2A(1978) 10' - 6" 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/1/2015 2:56:03 PM A130A.1A Checker Author PEDESTRIAN PROTECTION / ENTRY / GIFT SHOP JUNE 2, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING ENTRY / PEDESTRIAN PROTECTION 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 201, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/8" = 1'-0" 1 PEDESTRIAN PROTECTION / ENTRANCE PARTIAL FLOOR PLAN 1/8" = 1'-0" 2 DEMOLITION - PARTIAL FLOOR PLAN 1/8" = 1'-0" 3 EXISTING PARTIAL REFLECTED CEILING PLAN 1/8" = 1'-0" 4 PEDESTRIAN PROTECTION / ENTRANCE PARTIAL FLOOR PLAN - RCP REFLECTED CEILING PLAN DEMO NOTES REMOVE EXISTING LIGHT FIXTURES, DIFFUSERS, GRILLS THAT OVERLAP NEW WALLS, SAVE FOR REINSTALLATION. 1. 5 NORTH WEST VIEW 6 PEDESTRIAN PROTECTION / ENTRY SECTION - DOOR HEAD 11 11 11 11 11 11 11 11 11 ADDENDUM # 1 06.30.2015 07/02/15