Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0190_E101_1435865520.pdf
P P P P FACP FACP FACP FACP P P M M P P P P P P P P P FACP FACP FACP FACP P M M S15cd X1E X1E S1E E4 L2 L2 L2 M E4 EM EM RL RL POWER LEGEND (Not all symbols listed below are used on these drawings) SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, HALF SWITCHED DUPLEX RECEPTACLE, CEILING MOUNTED DUPLEX RECEPTACLE, FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED SPECIAL RECEPTACLE SPECIAL RECEPTACLE, FLOOR MOUNTED JUNCTION BOX, WALL OR CEILING MOUNTED JUNCTION BOX, FLOOR MOUNTED DISCONNECT SWITCH (NON-FUSED) DISCONNECT SWITCH (FUSED) VARIABLE SPEED DRIVE WITH DISCONNECT UTILITY METER ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER CABINET AS NOTED PLUG MOLD (MULTI-OUTLET ASSEMBLY) CONDUIT EXPOSED CONDUIT TURNING DOWN CONDUIT TURNING UP CONDUIT CAPPED MAIN SWITCHBOARD/DISTRIBUTION CENTER CURRENT TRANSFORMER GENERATOR ANNUNCIATOR PANEL CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR AS ALLOWED PER SPECIFICATIONS BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS, SUBSCRIPTS INDICATE PANEL & CIRCUITS DESCRIPTION SYMBOL DESCRIPTION SYMBOL CLG J J M WM A-1,3,5 T CT GANN MOTOR CONDUIT CONCEALED GROUND BAR TRANSFORMER THERMOSTAT SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING) TWO POLE SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH KEY OPERATED SWITCH MANUAL SWITCH, HORSEPOWER RATE DIMMER SWITCH LOW VOLTAGE SWITCH VARIABLE SPEED/SPEED CONTROLLER SWITCH EXPLOSION PROOF SWITCH THERMAL OVERLOAD SWITCH MOMENTARY CONTACT SWITCH COMBINATION SWITCH AND DUPLEX RECEPTACLE PHOTOCELL TIME CLOCK SWITCH WITH PILOT LIGHT LOCATOR (CONTINUOUSLY LIGHTED HANDLE) PUSH BUTTON OCCUPANCY SENSOR - WALL MOUNTED IR=INFRARED, US=ULTRASONIC, DT=DUAL TECHNOLOGY Sa S2 S3 S4 SK SM SD SPI SP SLV SVS SEP STO SMC S TC ABBREVIATIONS LEGEND AMPERES ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ANNUNCIATOR ABOVE RAISED FLOOR AIR SAMPLING SMOKE DETECTION AUTOMATIC TRANSFER SWITCH BELOW FINISHED GRADE MOTOR CIRCUIT PROTECTOR SEE MECHANICAL EQUIPMENT SCHEDULE MINIMUM MAIN LUGS ONLY MANUAL TRANSFER SWITCH NORMALLY CLOSED NIGHT LIGHT NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EMERGENCY MAIN DISTRIBUTION CENTER EXPLOSION PROOF EMERGENCY POWER OFF EMERGENCY VENTILATION ON/OFF ELECTRIC WATER COOLER FIRE ALARM GROUND GENERATOR CONTROL PANEL GROUND FAULT INTERRUPTING HAND OFF AUTOMATIC ISOLATED GROUND MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER TRANSFORMER WEATHER PROOF WITHOUT WITH VARIABLE FREQUENCY DRIVE VOLTS UNINTERRUPTIBLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF SUB-DISTRIBUTION CENTER STAND-BY PULL BOX ON SITE WORK FORCE OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH NOT IN CONTRACT DESCRIPTION SYMBOL DESCRIPTION SYMBOL REFERENCE SYMBOLS LEGEND (Not all symbols listed below are used on these drawings) KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE MECHANICAL EQUIPMENT REFERENCE EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO BE RELOCATED EXISTING TO REMAIN - REPLACE DEVICE DESCRIPTION DESCRIPTION SYMBOL A-1 1 LC1 UH E R RL ER FIRE ALARM SYSTEM LEGEND (Not all symbols listed below are used on these drawings) FIRE ALARM CONTROL PANEL FIRE ALARM SYSTEM ANNUNCIATOR PANEL (GRAPHIC/LED) MANUAL PULL STATION ADDRESSABLE INPUT MODULE ADDRESSABLE OUTPUT MODULE THERMAL DETECTOR F=FIXED TEMPERATURE, R=FIXED TEMPERATURE & RATE OF RISE (TEMP. RATING) SMOKE DETECTOR (P=PHOTOELECTRIC, SB=WITH SOUNDER BASE, BR=BEAM RECEIVER, BT=BEAM TRANSMITTER) AUDIOVISUAL DEVICE (H##cd=HORN/STROBE COMBINATION S=SPEAKER/STROBE COMBINATION, C=CHIME/STROBE COMBINATION) REMOTE ANNUNCIATOR PANEL FIRE ALARM DIRECTORY ANNUNCIATOR FLAME DETECTOR (UV=ULTRAVIOLET, IR=INFRARED) DUCT SMOKE DETECTOR S=SUPPLY, R=RETURN DUCT DETECTOR REMOTE INDICATOR ALARM AND TEST REMOTE INDICATOR LIGHT CARBON MONOXIDE ALARM/DETECTOR FLOW DETECTOR SWITCH TAMPER SWITCH MAGNETIC DOOR HOLD EMERGENCY TELEPHONE STATION (J=JACK, H=HANDSET) FIRE ALARM STROBE (cd= CANDELA RATING 15, 30, 75, 110) AUDIBLE DEVICE (H=HORN, S=SPEAKER, C=CHIME) DESCRIPTION DESCRIPTION FACP FAPS FSA FAA RACP FSC FAD P F UV RTS M AOM H15cd H 15cd J SYMBOL SYMBOL (Not all symbols listed below are used on these drawings) T PM CONTROLS LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) AIM P MDC MCC MCB MAX IG HOA GFI GCP G FA EWC EVO EPO EP EMDC EM (E) CCTV CB CATV C BFG ATS ASSD ARF ANN AFG AFF AC A XFMR WP W/O W/ VFD V UPS UON UG UF TYP TVSS TP SDC SB PB OSWF OFOI OFCI OC NTS NO NL NIC NC MTS MLO MIN MEC MCP WIREMOLD (SURFACE RACEWAY) SHADING INDICATES EMERGENCY SYSTEM TEXT INDICATES PANEL AND CIRCUIT DESIGNATION SWITCH WITH PILOT LIGHT (PILOT LIGHT IS 'ON' WHEN SWITCH IS 'ON') KEY NOTE REFERENCE SYMBOL PC K DIRECT DISTRIBUTION, WALL MOUNT LINEAR DECORATIVE LINEAR WALLMOUNT INDIRECT DISTRIBUTION, WALL MOUNT LINEAR LENSED TROFFER PATIENT OVERBED LIGHT SURFACE OR PENDANT MOUNTED LUMINAIRE DIRECT/INDIRECT TROFFER DIRECT/INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT DIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT DIRECT/INDIRECT DISTRIBUTION, WALL MOUNT LINEAR STRIP LINEAR WALLMOUNT ADJUSTABLE ACCENT DOWNLIGHT WALL WASH DOWNLIGHT DOWNLIGHT SURFACE OR PENDANT MOUNTED STRIP OR INDUSTRIAL LUMINAIRE SURFACE DOWNLIGHT DARKROOM SAFE LIGHT (TWO COMPARTMENT SHOWN) EXIT LIGHT, ARROWS AS INDICATED, FACES INDICATED BY SHADING PORCELAIN KEYLESS LAMPHOLDER, BRYANT #5228 W/ 100W A19 UNDERCABINET LIGHT EMERGENCY LIGHTING UNIT EXTERIOR STAKE MOUNTED RECESS MOUNTED WALL LUMINAIRE I.F. LAMP. 'PC' INDICATES PULLCHAIN SQUARE ADJUSTABLE ACCENT DOWNLIGHT DECORATIVE PENDANT PENDANT DECORATIVE POLE POLE SQUARE DOWNLIGHT DECORATIVE ADJUSTABLE ACCENT DOWNLIGHT DECORATIVE WALL WASH DOWNLIGHT DECORATIVE DOWNLIGHT SQUARE WALL WASH DOWNLIGHT A a SWITCHING, UPPER CASE SUBSCRIPT INDICATES LUMINAIRE TYPE (TYP) SHADING INDICATES EM SYSTEM, LOWER CASE SUBSCRIPT INDICATES LIGHTING LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) BOLLARD DECORATIVE SCONCE WALL PACK OR EXTERIOR NON-DECORATIVE WALL SIGNAGE DOCK LIGHT TRACK HEAD THEATRICAL PIPE OR TRACK LIGHTING SQUARE ADJUSTABLE ACCENT DOWNLIGHT SQUARE DOWNLIGHT SQUARE WALL WASH DOWNLIGHT M LPA-# TYPICAL CIRCUIT NUMBER TYPICAL LUMINAIRE TYPE 1 TG# FIRE FIGHTER SMOKE CONTROL PANEL RESCUE ASSISTANCE SYSTEM HEAD END UNIT FIRE ALARM (NAC) POWER SUPPLY GRAPHIC ZONE MAP GZM RESCUE ASSISTANCE TELEPHONE STATION) RA FSD CO PRESSURE SWITCH FIRE/SMOKE DAMPER LIGHTING CONTROL / EQUIPMENT REFERENCE TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR) X X N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/1/2015 3:43:10 PM E101 NCW CLP PEDESTRIAN ENTRY LIGHTING, POWER AND FIRE ALARM PLANS JUNE 2, 2015 FOR CONSTRUCTION VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 SCALE: 1/8" = 1'-0" PEDESTRIAN ENTRY SCALE: 1/8" = 1'-0" DEMOLITION PEDESTRIAN ENTRY KEYNOTES E4 RELOCATED POWER FOR AUTO DOOR EXTEND EXISTING CIRCUIT TO NEW LOCATION. L2 CONNECT NEW LIGHTING TO LOCAL EXISTING POWER CIRCUIT. GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND ORDERING MATERIALS OR EQUIPMENT. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. DEMOLITION NOTES: 1. 2. 3. 4. 5. 6. 7. UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO BE REMOVED. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR DAMAGED DURING RELOCATION. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS NOTED OTHERWISE. LIGHTING PLAN NOTES: 1. 2. 3. REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES. POWER PLAN NOTES: 1. 2. 3. 4. 5. 6. 7. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. ALL DEVICES FED FROM AN EMERGENCY CIRCUIT SHALL BE RED. WAITING AND PEDIATRIC AREAS TO BE PROVIDED WITH HOSPITAL GRADE TAMPER RESISTANT RECEPTACLES. NO RECEPTACLES SHALL BE MOUNTED BELOW +18" AFF. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES. FIRE ALARM PLAN NOTES: 1. 2. LOCATE SMOKE DETECTORS PER NFPA 72 AND MANUFACTURERS REQUIREMENTS. THE LOCATIONS OF SMOKE DETECTORS ON THE DRAWINGS ARE DIAGRAMMATIC ONLY. DETECTORS SHALL NOT BE PLACED WITHIN 3'-0" OF ANY CEILING MOUNTED HVAC SUPPLY AIR DEVICE. NEW FIRE ALARM DEVICES SHALL MATCH EXISTING, UNLESS NOTED OTHERWISE. PROVIDE RE-PROGRAMMING OF SYSTEM AS REQUIRED TO ACCOMMODATE NEW DEVICES. REVISE EXISTING ANNUNCIATOR(S) AND GRAPHIC ZONE MAP(S) TO REFLECT PROJECT FIRE ALARM AND ARCHITECTURAL MODIFICATIONS. UPDATE GRAPHIC ZONE MAPS IN BOTH THE FIRE COMMAND CENTER AND ON THIS FLOOR AS REQUIRED. SUBMIT TO ENGINEER AND BUILDING/FIRE DEPARTMENTS FOR REVIEW PRIOR TO INSTALLATION. Type Description Lamp Apparent Load Ballast Voltage Manufacturer Catalog Series Finish Mounting Depth Note S1E 4' FLUORESCENT CHAIN HUNG STRIP LGIHT (2) 32W T8 3500K 64 VA 277 V LITHONIA C SERIES CHAIN HUNG X1E EXIT SIGN 5 VA 277 V SURFACE PROVIDED BY OWNER L U M I N A I R E S C H E D U L E ADDENDUM 1 06.30.2015 07/02/15