HomeMy WebLinkAboutB15-0193_S005_1435611540.pdfx SOIL TYPES AND DESIGN PROPERTIES SHALL BE CONFIRMED BY THE SITE GEOTECHNICAL ENGINEER PRIOR TO WALL CONSTRUCTION. x THE WALLS ARE DESIGNED TO SUPORT THE FOLLOWING MAXIMUM SURCHARGE LOADINGS: BACKSLOPE - 3H: 1V MAX SOIL BEARING CAPACITY 1500 PSF EQUIVALENT FLUID PRESSURE (EFP) 50 x THE WALL DESIGN MAINTAINS A MINIMUM FACTOR OF SAFETY OF 1.5 ON ALL ELEMENTS OF THE STATIC WALL DESIGN UNLESS OTHERWISE NOTED. GLOBAL STABILITY, WHEN EVALUATED, MAINTAINS A MINIMUM FACTOR OF SAFETY OF 1.3 UNLESS OTHERWISE NOTED. x WALL CONSTRUCTION SHALL BE MONITORED BY A QUALIFIED ENGINEER TO VERIFY FIELD CONDITIONS. IF THIS WORK IS NOT PERFORMED BY THE ENGINEER, THE ENGINEER SHALL BE CONSULTED IN THOSE MATTERS PERTAINING TO SOIL CONDITIONS AND WALL PERFORMANCE. x THE FOUNDATION SOILS AT EACH WALL LOCATION SHALL BE INSPECTED BY THE ENGINEER AND ANY UNSUITABLE SOILS OR IMPROPERLY COMPACTED EMBANKMENT MATERIAL REMOVED AND REPLACED AS DIRECTED BY THE ENGINEER PRIOR TO WALL CONSTRUCTION TO PROVIDE ADEQUATE BEARING CAPACITY AND MINIMIZE SETTLEMENT. x ALL WALL EXCAVATION AND RETAINED SOILS SHALL BE INSPECTED FOR GROUNDWATER CONDITIONS AND ANY ADDITIONAL DRAINAGE PROVISIONS REQUIRED IN THE FIELD SHALL BE INCORPORATED INTO THE WALL CONSTRUCTION AS DIRECTED BY THE ENGINEER. x WALL BACKFILL MATERIAL SHALL BE TESTED AND APPROVED BY THE ENGINEER FOR USE IN THE REINFORCED SOIL ZONE MEETING THE MINIMUM REQUIREMENTS OF THE APPROVED DESIGN PLANS. ALL BACKFIL MATERIAL MUST BE APPROVED BY MARTIN/MARTIN, INC. A GRADATION AND APPLICABLE LAB TESTING RESULTS OF ANY MATERIAL CONSIDERED SUBMITTED FOR APPROVAL. x ALL SOIL BACKFILL SHALL BE TESTED BY THE ENGINEER FOR MOISTURE, DENSITY, AND COMPACTION PERIODICALLY (EVERY 2' VERTICALLY, 100'-200' C/C) AND SHALL MEET THE MINIMUM REQUIREMENTS OF THE APPROVED DESIGN PLANS OR PROJECT SPECIFICATIONS. x WALL CONSTRUCTION SHALL BE PERIODICALLY INSPECTED BY THE ENGINEER TO ENSURE THE GEOGRID REINFORCEMENT ELEVATIONS AND LENGTHS ARE INSTALLED IN ACCORDANCE WITH THE APPROVED DESIGN PLANS. x ALL WALL ELEVATIONS, GRADES, AND BACKSLOPE CONDITIONS SHALL BE VERIFIED BY THE ENGINEER IN THE FIELD FOR CONFORMANCE WITH THE APPROVED DESIGN PLANS. ANY REVISIONS TO THE STRUCTURE GEOMETRY OR DESIGN CRITERIA SHALL REQUIRE DESIGN MODIFICATION PRIOR TO PROCEEDING WITH CONSTUCTION. x THE SOIL PLACED BEHIND THE WALL IN THE BACKFILL ZONE SHOULD BE COMPACTED TO 95% OF ITS MAXIMUM STANDARD PROCTOR DRY DENSITY (ASTM D- 1557). BACKFILL MUST BE COMPACTED BY MECHANICAL MEANS. NO WATER FLOODING TECHNIQUES OF ANY TYPE SHOULD BE USED IN THE COMPACTION OF THE BACKFILL ON THIS SIDE. HIGHLY EXPANSIVE SOILS OR CLEAN SANDS ARE NOT TO BE USED AS FOUNDATION BACKFILL. THE SOILS SHOULD BE CONDITIONED TO ACHIEVE A MOISTURE CONTENT WITHIN ±2% OF THE SOIL'S OPTIMUM MOISTURE CONTENT. x RIDE-ON MECHAINCAL COMPACTION EQUIPMENT SHOULD BE OPERATED NO CLOSER THAN WITHIN 3' OF THE KEYSTONE UNIT BACK SURFACE. x DO NOT OVER COMPACT OR COMPACT SOILS NEXT TO THE BACK OF THE UNIT IN AN UNCONTROLELD MANNER. THIS MAY DRIVE DRAINAGE MATERIALS UNDER THE UNIT, FORCING THE UNITS OUT OF LEVEL. IF THIS CONTINUES, THE WALL MAY BEGIN TO LEAN FORWARD. x ALL SOIL TESTING SHOULD BE PERFORMED BY A QUALIFIED ENGINEER. SOIL TESTS SHOULD BE TAKEN NO CLOSER THAN TWO FEET FROM THE BACK SURFACE OF THE KEYSTONE UNIT. x THE SAME PLACEMENT RULES APPLY FOR EACH CONDITION. IN GENERAL, ALL SOILS SHOULD BE PLACED IN NO MORE THAN 8" THICK LIFTS, THE HEIGHT OF A SINGLE KEYSTONE UNIT. MORE SPECIFICALLY, THE PROPER THICKNESS OF MATERIAL PLACED IN A SINGLE LIFT IS DEPENDENT ON THE TYPE OF SOILS AND COMPACTION EQUIPMENT BEING USED. FOR EXAMPLE, CRUSHED STONE (USED FOR UNIT/DRAINAGE) MAY BE PLACED IN MAXIMUM LIFTS AND WILL COMPACT WITH MINIMAL EFFORT. MOST INORGANIC SITE SOILS, EASILY INFLUENCED BY MOISTURE LEVELS, MUST BE PLACED IN SHORTER LIFTS AND WILL REQUIRE GREATER COMPACTION EFFORT. x ALL PLACEMENT, INSTALLATION, AND CONSTRUCTION OF THE KEYSTONE UNITS, GEOGRID REINFORCEMENT, AND CONNECTION COMPONENTS SHOULD BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, REQUIREMENTS, AND SPECIFICATIONS. x THIS WORK CONSISTS OF DESIGNING, FURNISHING AND INSTALLING A CONCRETE BLOCK FACING MECHANICALLY STABILIZED EARTH (MSE) RETAINING WALL SYSTEM AT THE LOCATIONS AND TO THE LINES AND GRADES SHOWN ON THE PLANS. THE MSE WALL SYSTEM CONSTRUCTED ON THIS PROJECT SHALL BE AN ENGINEERED SYSTEM COMBINING A BLOCK AND GEOSYNTHETIC REINFORCEMENT (GEOGRID) FROM THE LIST OF ACCEPTABLE PRODUCTS. x MSE WALL SYSTEM: ENGINEERED MECHANICALLY STABILIZED EARTH WALL SYSTEM CONSISTING OF A CONCRETE MODULAR BLOCK UNIT, GEOSYNTHETIC SOIL REINFORCEMENT, BACKFILL AND SUBSURFACE DRAINAGE. x CONCRETE MODULAR BLOCK: CONCRETE MASONRY BLOCK MANUFACTURED SPECIFICALLY FOR USE IN A MSE WALL SYSTEM. x GEOSYNTHETIC SOIL REINFORCEMENT: GEOGRID PRODUCT OF HIGH-DENSITY POLYETHYLENE EXPANDED SHEET OR POLYESTER WOVEN FIBER MATERIALS, SPECIFICALLY FABRICATED FOR USE AS SOIL REINFORCEMENT. x MSE WALL BACKFILL: THE BACKFILL FOR THE MSE WALL SYSTEM SHALL BE A NON-CORROSIVE WELL-GRADED GRANULAR BACKFILL FREE OF DEBRIS, WASTE, FROZEN MATERIALS, VEGETATION AND OTHER DELETERIOUS MATTER. BACKFILL SHALL MEET ALL DESIGN REQUIREMENTS AND GRADATIONS SPECIFIED HEREIN. MATERIALS WILL BE EVALUATED AND APPROVED BY OWNER'S GEOTECHNICAL ENGINEER PRIOR TO THEIR USE. x CONCRETE MODULAR BLOCK: THE CONCRETE BLOCK SHALL CONFORM TO THE REQUIREMENTS IN THE CONTRACT PLANS AND THESE NOTES INCLUDING THE COLOR, TEXTURE, AND PATTERN. THE BLOCK SHALL BE TESTED IN ACCORDANCE WITH THE FOLLOWING REQUIREMENTS. THE CONTRACTOR SHALL PROVIDE CERTIFICATION THAT THE RESULTS OF THESE TESTS MEET THE REQUIREMENTS OF THE APPROPRIATE SPECIFICATION. O COMPONENTS: THE CEMENTITIOUS MATERIALS SHALL BE PORTLAND CEMENT, WHICH SHALL CONFORM TO THE REQUIREMENTS OF ASTM C 150. FLY ASH MAY BE USED BUT SHALL NOT EXCEED 20% BY WEIGHT OF THE TOTAL CEMENT CONTENT AND SHALL CONFORM TO THE REQUIREMENTS OF ASTM C 618. O AGGREGATES USED IN THE MANUFACTURE OF THE UNITS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C 33 FOR NORMAL WEIGHT CONCRETE AGGREGATE. O ALL BLOCK SHALL INCLUDE THE ADDITIVE "DRY BLOCK INHIBITOR" BY DRI AND DRI CONCRETE PRODUCERS, OR OWNER'S ENGINEER APPROVED EQUAL. THE EXACT AMOUNT OF ADDITIVE USED SHALL BE AS RECOMMENDED BY THE ADDITIVE MANUFACTURER. O BLOCK/REINFORCEMENT CONNECTION TEST: THE BLOCK TO BLOCK AND BLOCK TO REINFORCEMENT CONNECTION TEST SHALL CONFORM TO THE REQUIREMENTS OF NCMA. O METHODS SRWU- 1 AND SRWU-2. THE SERVICE STATE CONNECTION STRENGTH SHALL BE DETERMINED WITH THE .75" PERFORMANCE LIMIT. x REFERENCED STANDARDS: COMPLY WITH APPLICABLE REQUIREMENTS OF STATE AND LOCAL STANDARDS. IN THE EVENT OF CONFLICT BETWEEN REFERENCED STANDARDS AND CONTRACT DOCUMENTS, COMPLY WITH CONTRACT DOCUMENTS. x TESTING AND INSPECTION SERVICES: OWNER WILL EMPLOY A QUALIFIED INDEPENDENT GEOTECHNICAL ENGINEERING TESTING AGENCY TO CLASSIFY PROPOSED ON-SITE AND BORROW SOILS TO VERIFY THAT SOILS COMPLY WITH SPECIFIED REQUIREMENTS AND DESIGN PARAMETERS, AND TO PERFORM REQUIRED FIELD AND LABORATORY TESTING. x DESIGN METHOD: THE NEW RETAINIG SYSTEM OUTLINED IN THE FOLLOWING PLANS HAS BEEN DESIGNED IN CONFORMANCE WITH 2003 IBC REQUIREMENTS AND IS ALSO IN COMPLIANCE WITH THE NCMA'S "DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS, 1997, SECOND EDITION, SECOND PRINTING" AND CONFORM TO THE MINIMUM SAFETY FACTORS AS SPECIFIED IN THIS SPECIFICATION SECTION. DESIGN SUBMITTALS NOT MEETING THIS DESIGN CRITERIA OR TECHNICAL/ADMINISTRATIVE CRITERIA AS SPECIFIED WILL BE REJECTED IN THEIR ENTIRETY UNTIL COMPLETE COMPLIANCE IS ACHIEVED. OWNER RESERVES ALL RIGHTS IN DETERMINING COMPLIANCE FOR PLAN APPROVAL AND MAY REJECT ANY SUBMITTALS. x DESIGN HEIGHT: THE WALL DESIGN HEIGHT SHALL BE MEASURED VERTICALLY FROM THE TOP OF THE LEVELING PAD TO THE TOP OF WALL. x SOIL REINFORCEMENT LENGTH: THE SOIL REINFORCEMENT LENGTH SHALL BE MEASURED FROM THE FRONT FACE OF THE CONCRETE BLOCK FACE TO END OF REINFORCEMENT. MINIMUM REINFORCEMENT LENGTH (RL) SHALL EQUAL .7 X WALL HEIGHT (H) OR 5 FEET WHICH EVER IS GREATER. THE REINFORCEMENT LENGTH SHALL BE AS REQUIRED BY THE DESIGN. THE LENGTH OF SOIL REINFORCEMENT SHALL BE EQUAL FROM TOP TO BOTTOM AT ALL LAYERS OF WALL. x PULLOUT AND BLOCK CONNECTION STRENGTH: THE FACTOR OF SAFETY FOR PULLOUT RESISTANCE SHALL BE GREATER THAN OR EQUAL TO 1.5. REINFORCEMENT CONNECTIONS TO THE FACING BLOCK SHALL BE DESIGNED (AND TESTED PER SUBSECTION 2.1.D.2 OF THIS SPECIFICATION) TO CARRY 100% OF THE CORRESPONDING REQUIRED LTDS AT ALL REINFORCED LEVELS. x BACKFILL: THE BACKFILL FOR THE REINFORCED SOIL ZONE SHALL BE CONSIDERED NON-AGGRESSIVE FOR CORROSION AND DURABILITY. THE FRICTION ANGLE, PHI, SHALL BE A VALUE APPROPRIATE FOR THE FILL MATERIAL USED. x TIERED WALLS: O ALL TIERED (MULTI LEVEL) RETAINING WALL ARRANGEMENTS SHALL BE ANALYZED AS A COMBINED WALL SYSTEM IN ACCORDANCE WITH SECTION 2.5.4 OF NCMA'S DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS, SECOND EDITION. O THE SLOPE OF THE GROUND BETWEEN TIERED RETAINING WALLS SHALL NOT EXCEED A 4 (HORIZONTAL) TO 1 (VERTICAL). x THE DRAWINGS SHALL PROVIDE THE DETAILS NECESSARY TO DEMONSTRATE COMPLIANCE WITH THE REQUIREMENTS IN THE PLANS AND THESE NOTES, INCLUDING BUT NOT LIMITED TO: O THE WALL LAYOUT (SCALEABLE ELEVATION VIEW) IN CONFORMITY TO LINE AND GRADE SHOWN ON THE CONTRACT PLANS, INCLUDING THE LEVELING PAD ELEVATIONS, LEVELING PAD STEPS, TOTAL NUMBERS OF BLOCKS AND ASSOCIATED BLOCK ELEVATIONS INCLUDING THE TOP OF BLOCK ELEVATIONS. O DETAILS OF THE MSE WALL FACING BLOCKS AND ATTACHMENTS TO THE SOIL REINFORCEMENT. THE FACIAL BLOCKS SHALL BE CONNECTED TO EACH LAYER OF SOIL REINFORCEMENT, UNLESS SHOWN OTHERWISE ON THE PLANS. O THE SOIL REINFORCEMENT TYPES, SPACING, LENGTHS, ELEVATIONS, AND THE CORRESPONDING WALL DESIGN HEIGHT SEGMENTS SHALL BE SHOWN ON THE WALL LAYOUT. O THE REQUIRED REINFORCEMENT LTDS AND THE SUPPLIED LTDS (DETERMINED IR ACCORDANCE WITH DESIGN REQUIREMENTS OF THIS SPECIFICATION) WITH CORRESPONDING BRAND AND GRADE OF MATERIAL SHALL BE LISTED SIDE BY SIDE. THE LTDS OF THE SUPPLIED REINFORCEMENT GRADE MUST MEET OR EXCEED THE REQUIRED LTDS CORRESPONDING WITH THE REINFORCEMENT SPACING PROVIDED. THE CONTRACTOR SHALL PROVIDE MINIMUM AVERAGE ROLL VALUE (MARV) CERTIFICATION, WHICH STATES THE MARV OF THE SUPPLIED MATERIAL HAS BEEN DETERMINED IN ACCORDANCE WITH ASTM D-4595. O A TYPICAL SECTION OF THE WALL SHOWING ALL PERTINENT INFORMATION INCLUDING, BUT NOT LIMITED TO, SLOPE IN FRONT AND BEHIND THE WALL, SOIL COVER AT TOE, SOIL ZONES, DRAINAGE DETAILS ETC. O ALL CONSTRUCTION REQUIREMENTS SHALL BE INCLUDED ON THE CONSTRUCTION DRAWINGS. INCLUDING ANY NOTES, SPECIFICATIONS, OR ANY OTHER REQUIREMENTS THE WALL DESIGN ENGINEER DEEMS NECESSARY. DRAINAGE: 1. PROVIDE DRAINAGE AWAY FROM THE BUILDING IN ACCORDANCE WITH THE FOLLOWING: A. SLOPE THE GROUND SURFACE AWAY FROM THE BUILDING WITH A MINIMUM GRADIENT OF 5% FOR THE FIRST TEN FEET. B. PAVED AREAS SHOULD HAVE A MINIMUM SLOPE OF 2% AWAY FROM THE BUILDING. C. DOWNSPOUT EXTENSIONS SHOULD EXTEND ACROSS THE BACKFILL ZONE. D. NO IRRIGATION DEVICES SHOULD BE PLACED WITHIN 5 FEET OF THE FOUNDATION. E. DO NOT ALLOW WATER TO POND OR STAND NEXT TO FOUNDATIONS. F. NO SIGNIFICANT LANDSCAPING SHOULD BE INSTALLED WITHIN 5 FEET OF THE FOUNDATION. G. ALL LANDSCAPING EDGING SHOULD BE PERFORATED TO AVOID DAMMING OF WATER IN THE MULCHED AREAS. 2. VERIFY THAT THE PERIMETER FOUNDATION DRAIN SYSTEM AND BELOW-GRADE DOWNSPOUT DRAINS ARE INSTALLED AND FUNCTIONING PROPERLY. EARTHWORK DRAINAGE AND SEGMENTED WALL CONSTRUCTION 1. THE LAYOUT IS BASED ON FIELD MEASUREMENTS. THE LAYOUT IS APPROXIMATE AND IS INTENDED AS A REPRESENTATION ONLY. 2. THE REPAIR RECOMMENDATIONS CONTAINED IN THIS DOCUMENT ARE BASED ON INFORMATION OBTAINED FROM REVIEW AND EVALUATION OF PROBLEMS THAT WERE READILY VISIBLE AT THE TIME OF OUR SITE VISIT. NO CLADDING, SHEATHING, OR FINISH MATERIALS OF ANY KIND WERE REMOVED UNLESS SPECIFICALLY NOTED. AS A RESULT OF THESE LIMITATIONS, LATENT STRUCTURAL DAMAGES MAY EXIST WHICH WERE NOT DETECTED. ANY SUCH DAMAGES SHOULD BE BROUGHT TO OUR ATTENTION IF FOUND. 3. THE RECOMMENDATIONS CONTAINED HEREIN ARE BASED ON CURRENTLY EXISTING CONDITIONS AND HAVE BEEN PREPARED IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING PRACTICE. NO WARRANTY REGARDING THE FUTURE PERFORMANCE OF THE STRUCTURE INCLUDING THE REPAIRED AREAS ARE MADE, EXPRESSED OR IMPLIED. 4. IN ORDER TO MINIMIZE FUTURE FOUNDATION AND SLAB MOVEMENT, PROPER SURFACE DRAINAGE AND GRADING SHOULD ALSO BE MAINTAINED. THE GROUND SURFACE SHOULD BE SLOPED AWAY FROM THE BUILDING WITH A MINIMUM GRADIENT OF 5% (A MINIMUM OF 2% FOR PAVED SURFACES) FOR THE FIRST 10 FEET. THIS IS EQUIVALENT OF 6 INCHES OF FALL ACROSS THIS 5-FOOT ZONE. MAINTENANCE OF PROPER SITE DRAINAGE WILL REDUCE THE AMOUNT OF RUNOFF WATERS PERCOLATING INTO THE GROUND ADJACENT TO THE RESIDENCE. ROOF DRAINS SHOULD BE CARRIED ACROSS THE BACKFILL ZONES AND DISCHARGED AWAY FROM THE BUILDING. THE AREA ADJACENT TO THE FOUNDATION SHOULD BE REPAIRED TO SATISFY THE ABOVE-MENTIONED CONDITIONS. 5. PREPARATION OF THE SUBGRADE SOILS PRIOR TO PLACEMENT OF NEW CONCRETE CURB, GUTTER, RAMPS, SIDEWALKS AND OTHER FLATWORK SHOULD COMPLY WITH LOCAL CODE REQUIREMENTS. 6. COLLATERAL DAMAGE TO EXISTING LANDSCAPING AND/OR DRAINAGE SYSTEMS SHOULD BE REPAIRED BY THE CONTRACTOR. 7. THE INSTALLATION AND MAINTENANCE OF TEMPORARY EROSION CONTROL MEASURES IS THE RESPONSIBILITY OF THE CONTRACTOR. 8. COMPACT BACKFILL TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TO WITHIN 2% OF OPTIMUM MOISTURE CONTENT. THE OWNER IS ENCOURAGED TO PROVIDE GRADING THAT HAS POSITIVE DRAINAGE (1/4" PER FOOT MINIMUM) TO MUNICIPAL SEWER RECEPTACLE OR APPROVED DRAINAGE CONFIGURATION. ALL BACKFILL SHALL BE INHERENTLY NON-SWELLING RELATIVELY IMPERVIOUS SOILS, SUCH AS SILTY SAND OR "CRUSHER REJECT". THE MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. THE FILL SHALL BE COMPACTED TO 95% OF THE MAXIMUM STANDARD PROCTOR DENSITY AT A MOISTURE CONTENT SUFFICIENT TO MINIMIZE SWELL POTENTIAL. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION, PROTECTION, AND REPAIR OF ALL UTILITIES ENCOUNTERED DURING CONSTRUCTION, WHETHER SHOWN ON THESE PLANS OR NOT. CONTRACTOR SHALL CONTACT REPRESENTATIVES OF THE RESPECTIVE UTILITIES AND HAVE ALL UTILITIES FIELD LOCATED PRIOR TO CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S REPONSIBILITY TO VERIFY ALL LOCATIONS OF EXISTING STRUCTURES AND UTILITIES SHOWN ON THE DRAWINGS, TO ASCERTAIN WHETHER ANY STRUCTURES AND UTILITIES MAY EXIST, AND REPAIR AND/OR REPLACE ANY STRUCTURES AND/OR UTILITIES THAT ARE DAMAGED BY THE CONTRACTOR. 10. ALL STORM SEWER LINES SHALL BE CLASS III REINFORCED CONCRETE PIPE IN ACCORDANCE WITH ASTM C76-73 - MIN. 12" DIAMETER. 11. CONTRACTOR TO PROVIDE ALL TRENCH SHORING TO SATISFY CODE AND OSHA REGULATIONS. S0.05 NOTES SHEET 5082 E. HAMPDEN AVE. SUITE 145 DENVER, CO. 80222 (303)229-1234 TIMBER FALLS CONDOMINIUMS PARTIAL PROPERTY WALL RECONSTRUCTION 4500 MEADOW DRIVE (BLDG'S 1 & 2) VAIL , COLORADO 8 1657 SHEET NUMBER: SHEET TITLE: REVISIONS: JOB NUMBER: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: DEC26052015-01 R. DAVIS M. WINGERTER R. DAVIS JUNE 7, 2015 06/29/15