HomeMy WebLinkAboutB15-0207_Engineering letter_1434564360.pdf aec Architectural Engineering Consultants, Inc. Mechanical, Electrical, & Lighting Design Services An Office with LEEDTTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 fax: 970-748-8521 email: stan@aec-vail.com web: www.aec-vail.com Keith Forney Storm King Mechanical skmkeith@aol.com Reference: Northwoods Unit 311 Plumbing Riser Review Hi Keith, This letter is intended to demonstrate how the addition of plumbing fixtures to the remodel at Northwoods Unit 311 can comply with the capacity limitations set by the 2015 International Plumbing Code (IPC). This remodel will add a shower to the third level, and a bathroom group (lavatory, water closet, shower) to the fourth level. Additionally, the clothes washer located on the third level will be relocated to the fourth level. This riser analysis has been completed off of original construction drawings dated 12/24/76. The contractor shall provide a comprehensive site review prior to installation to confirm that existing risers and fixture layouts match these existing plans. The contractor shall also confirm that all waste piping slopes at ¼”/foot, and shall confirm existing supply water pressures are suitable to handle the additional water load. If any of these conditions differ, please contact engineer for further review. See attached markups on the existing riser diagram for additional information. This information should be treated as a general guideline only; it is the contractor’s responsibility to ensure that all work adhere to the standards of the 2015 IPC. New 4th Level Bathroom Group and New 3rd Level Shower to Riser P-4 Connect the new water lines for the 4th level bathroom group and the 3rd level shower to existing riser P-4. Per the analysis below (per Appendix E of the 2015 IPC), this will maintain flows very close to or below 5 fps. Riser Location Riser Size Cold Riser Size Hot Existing Proposed WSFU GPM FPS WSFU GPM FPS 4th Floor 1” 5.7 10 3.7 8.4 13 5 3rd Floor 1 ¼” 11.1 15.5 4 14.8 17.5 4.5 2nd Floor 1 ½” 16.8 18.3 3 20.5 20 3.5 1st Floor 1 ½” 19.5 19.4 3.5 23.2 23 4 4th Floor 1” 4.5 8.7 3.3 6 10.7 4 3rd Floor 1” 7.5 12.3 4.5 10 14.6 5.2 2nd Floor 1 ¼” 10.5 15 3.7 13 16.5 4.1 1st Floor 1 ¼” 12 16 4 14.5 17.5 4.5 Northwoords Unit 311 Riser Analysis Page 2 of 2 June 10, 2015 Connect the new waste lines for the 4th level bathroom group and the 3rd level shower to existing riser P-4. Prior to connection, the existing waste lines shall be reworked as follows. The waste stack which jogs in the 2nd level ceiling shall be continued vertically (i.e. no horizontal offset) to the 3rd level ceiling, and the stack vent shall takeoff from this location. All existing horizontal drainage from the 4th floor fixtures, including the new bathroom group, shall be routed to this new stack extension. Per the analysis below (per Chapter 7 of the 2015 IPC), the added loads are below the accepted maximums for the pipes they serve. Line Location Line Size Existing DFU Proposed DFU Maximum Allowable DFU 4th Floor - Horizontal 3” 12 18 20 3rd Floor – Vertical 3” 12 18 20 3rd Floor – Horizontal 3” 12 14 20 2nd Floor – Vertical 3” 24 34 48 1st Floor - Vertical 3” 36 46 48 Relocated 4th Level Clothes Washer to Riser P-5 Connect new water lines from the relocated clothes washer to existing riser P-4. Per the analysis below (per Appendix E of the 2015 IPC), this will maintain flows near to or below 5 fps. Riser Location Riser Size Cold Riser Size Hot Existing Proposed WSFU GPM FPS WSFU GPM FPS 4th Floor ¾” 2.7 6 4 3.7 7.5 5 3rd Floor 1” 5.4 10 3.8 6.4 11 4.2 2nd Floor 1 ¼” 8.1 12.8 3 9.1 13.7 3.2 1st Floor 1 ¼” 10.8 15.4 3.9 11.8 15.8 4 4th Floor ¾” 1.5 4 2.5 2.5 5.7 3.8 3rd Floor ¾” 3 6.5 4.4 4 8 5.2 2nd Floor 1” 4.5 8.7 3.2 5.5 10 3.8 1st Floor 1” 6 10.7 4 7 11.8 4.4 Connect the new waste lines for the relocated clothes washer to existing riser P-5. Connect at the 3” main in the horizontal. Tie the vent line to the existing 3” vent. Per the analysis below (per Chapter 7 of the 2015 IPC), the added loads are below the accepted maximums for the pipes they serve. Line Location Line Size Existing DFU Proposed DFU Maximum Allowable DFU 4th Floor - Horizontal 3” 6 8 20 3rd Floor – Vertical 3” 12 14 20 2nd Floor – Vertical 3” 18 20 48 1st Floor - Vertical 4” 24 26 48 Sincerely, Taylor Critchlow, PE