HomeMy WebLinkAboutB15-0207_P2.0_1438612800.pdfLIVING ROOM
(EXIST)
BATH
ROOM 3
(EXIST)
STAIRS
(EXIST)
TV
KITCHEN
(NEW)
DINING ROOM
(EXIST)
BENCH
(EXIST)
BEDROOM 3
(EXIST)
BEDROOM 2
(EXIST)
BEDROOM 1
(EXIST)
BATH
ROOM 2
(EXIST)
COMMON
HALLWAY
(EXISTING)
UP
EXIST
PUBLIC
STAIRWELL
FIRE PLACE
(EXIST)
E11
E10
P
N
M
K
H
19.8 20 21 22 20.4
E11
E10
OPEN TO BELOW
BENCH
(NEW)
COMMON
HALLWAY
(EXISTING)
ENTRY
DOOR (NEW
LOCATION)
DN
FIRE PLACE
BELOW
(EXIST)
HALLWAY
STAIR
(EXIST)
DRY
WASH
LINEN
BATHROOM 4
(NEW)
BEDROOM 4
(NEW)
FAMILY ROOM
(NEW)
BATHROOM 5
(RELOCATED)
BATHROOM 6
(RELOCATED)
BEDROOM 5
(NEW)
BEDROOM 6
(NEW)
EXIST
PUBLIC
STAIRWELL
P
N
M
K
H
19.8 20 21 22
20.4 GENERAL NOTES:
1. THESE DRAWINGS ARE BASED UPON EXISTING DRAWINGS DATED
12/24/78. IT IS THE PLUMBING CONTRACTOR'S RESPONSIBILITY TO
VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO COMMENCING WORK.
THIS INCLUDES A VERIFICATION OF THE NUMBER OF PLUMBING FIXTURES
(ON ALL LEVELS) CONNECTING TO EXISTING WASTE, WATER, AND VENT
STACKS. IF ANY FIELD CONDITIONS VARY FROM THE 12/24/76 DRAWING
SET, CONTACT ENGINEER.
2. REPLACEMENT FIXTURES SHALL UTILIZE THE SAME CONNECTION SIZES
AS SHOWN IN SHEET DETAIL NOTES FOR NEW FIXTURES.
3. REFERENCE SHEET P1.0 FOR ADDITIONAL INFORMATION, NOTES, AND
VERIFICATION REQUIREMENTS.
4. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND
STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE
STRUCTURAL ENGINEER.
5. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE
A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY.
6. INSTALL CLEANOUTS PER SECTION 708 OF THE IPC. COORDINATE ALL
FINAL LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION.
CONNECT 1
2" CW, 1
2" HW, 1 1
2" W & 1 1
2" V TO LV.
CONNECT 1
2" CW, 3" W & 2" V TO WC.
CONNECT 3
4" CW, 3
4" HW, 2" W & 1 1
2" V TO SH.
CONNECT 3
4" CW, 3
4" HW, 2" W & 1 1
2" V TO CWB.
IT IS CRITICAL THAT RISER P-4 WASTE LINE RUNS AS A CONTINUOUS
STACK FROM THE FIRST FLOOR ALL THE WAY UP TO THE THIRD FLOOR
CEILING AND THAT THE EXISTING 4TH LEVEL BATHROOM, 4TH LEVEL
LAUNDRY ROOM, AND NEW 4TH LEVEL BATHROOM CONNECT TO THIS
VERTICAL STACK IN THE 3RD LEVEL CEILING (SEE RISER DIAGRAM,
SHEET P1.0). COORDINATE IN THE FIELD AS REQUIRED OR CONTACT
ENGINEER FOR ASSISTANCE.
CONNECT 3
4" CW AND 3
4" HW TO EXISTING DOMESTIC WATER RISER P-4
(1" EACH). VERIFY LOCATION AND SIZES IN THE FIELD.
CONNECT 3
4" CW AND 3
4" HW TO EXISTING DOMESTIC WATER RISER P-4
(1" HOT, 1 1
4" COLD). VERIFY LOCATION AND SIZES IN THE FIELD.
SHEET DETAIL NOTES:
1
2
3
4
5
6
7
CWB 4
3"
REPLACE AND RELOCATE
FIXTURES WITHIN THE
EXISTING BATHROOMS
AND RECONNECT TO
EXISTING RISER P-5. NO
ADDITIONAL FIXTURES IN
THIS AREA.
LV 1
WC 2
SH 3
REPLACE
FIXTURES WITHIN
THE EXISTING
BATHROOM AND
RECONNECT TO
EXISTING RISER
LOCATIONS. NO
NEW FIXTURES
ADDED IN THIS
LOCATION.
REPLACE FIXTURES WITHIN
THE EXISTING BATHROOM
AND RECONNECT TO
EXISTING RISER LOCATIONS.
NO NEW FIXTURES ADDED IN
THIS LOCATION.
REPLACE KITCHEN SINK AND
RECONNECT TO EXISTING LOCATION.
NO NEW FIXTURES ADDED IN THIS
LOCATION.
REMOVE CLOTHES WASHER AND
CAP EXISTING PLUMBING LINES IN
THIS LOCATION.
REMOVE EXISTING LAV AND ROUTE
EXISTING 1
2" HW, CW, AND 1 1
2" V LINES
FROM THIS LOCATION TO NEW LAV.
REPLACE FIXTURES WITHIN THE
EXISTING BATHROOM AND
RECONNECT TO EXISTING RISER
LOCATIONS. NO NEW FIXTURES
ADDED IN THIS LOCATION.
LV 1
SH
3
APPROXIMATE LOCATION
OF EXISTING 3" VENT
RISER P-5. REROUTE
VENT AS REQUIRED FOR
NEW FLOORPLAN.
1 1
2" 2"
2"
2" 1 1
2"
2"
CONNECT 2" WASTE
FROM WASHER TO 3"
COMMON HORIZONTAL
WASTE LINE TO RISER
P-5. SEE RISER DIAGRAM,
SHEET P1.0.
APPROXIMATE LOCATION
OF 3" VENT RISER P-4.
APPROXIMATE LOCATION
OF EXISTING 3" WASTE
AND 3" VENT RISER P-4.
5
CONNECT NEW 3" WASTE LINE
INTO 3" WASTE STACK P-4.
CONNECT NEW 2" VENT
TO 3" VENT RISER OR TO
2" COMMON HORIZONTAL
VENT FROM THE
BATHROOM GROUP.
APPROXIMATE LOCATION
OF EXISTING 3" WASTE
AND 3" VENT RISER P-5.
6
7
CONNECT 2" WASTE
FROM SHOWER TO 3"
COMMON HORIZONTAL
WASTE LINE TO RISER
P-5. SEE RISER DIAGRAM,
SHEET P1.0.
3
4
"
3
4
"
TOC AEC
PLUMBING
FLOORPLANS
SCALE: 1/4" = 1'-0"
P2.0
2 2
of www.aec-vail.com
C40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620
Mechanical, Electrical & Lighting Design Services
Architectural
Engineering
Consultants
Telephone: 970-748-8520 Fax: 970-748-8521
EGDrawn By: Checked By:
DATE: ISSUE:
07/02/15 PERMIT
AEC PROJECT #: NORTHWOODS UNIT 311
PLUMBING RISER REVIEW
VAIL, COLORADO 81657
15057
An Office with LEEDâ„¢ Accredited Professionals
NORTH
THIRD LEVEL PLUMBING PLAN
SCALE: 1/4" = 1'0"
NORTH
FOURTH LEVEL PLUMBING PLAN
SCALE: 1/4" = 1'0"
08/03/15