Loading...
HomeMy WebLinkAboutB15-0207_P2.0_1438612800.pdfLIVING ROOM (EXIST) BATH ROOM 3 (EXIST) STAIRS (EXIST) TV KITCHEN (NEW) DINING ROOM (EXIST) BENCH (EXIST) BEDROOM 3 (EXIST) BEDROOM 2 (EXIST) BEDROOM 1 (EXIST) BATH ROOM 2 (EXIST) COMMON HALLWAY (EXISTING) UP EXIST PUBLIC STAIRWELL FIRE PLACE (EXIST) E11 E10 P N M K H 19.8 20 21 22 20.4 E11 E10 OPEN TO BELOW BENCH (NEW) COMMON HALLWAY (EXISTING) ENTRY DOOR (NEW LOCATION) DN FIRE PLACE BELOW (EXIST) HALLWAY STAIR (EXIST) DRY WASH LINEN BATHROOM 4 (NEW) BEDROOM 4 (NEW) FAMILY ROOM (NEW) BATHROOM 5 (RELOCATED) BATHROOM 6 (RELOCATED) BEDROOM 5 (NEW) BEDROOM 6 (NEW) EXIST PUBLIC STAIRWELL P N M K H 19.8 20 21 22 20.4 GENERAL NOTES: 1. THESE DRAWINGS ARE BASED UPON EXISTING DRAWINGS DATED 12/24/78. IT IS THE PLUMBING CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO COMMENCING WORK. THIS INCLUDES A VERIFICATION OF THE NUMBER OF PLUMBING FIXTURES (ON ALL LEVELS) CONNECTING TO EXISTING WASTE, WATER, AND VENT STACKS. IF ANY FIELD CONDITIONS VARY FROM THE 12/24/76 DRAWING SET, CONTACT ENGINEER. 2. REPLACEMENT FIXTURES SHALL UTILIZE THE SAME CONNECTION SIZES AS SHOWN IN SHEET DETAIL NOTES FOR NEW FIXTURES. 3. REFERENCE SHEET P1.0 FOR ADDITIONAL INFORMATION, NOTES, AND VERIFICATION REQUIREMENTS. 4. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 5. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 6. INSTALL CLEANOUTS PER SECTION 708 OF THE IPC. COORDINATE ALL FINAL LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION. CONNECT 1 2" CW, 1 2" HW, 1 1 2" W & 1 1 2" V TO LV. CONNECT 1 2" CW, 3" W & 2" V TO WC. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO SH. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO CWB. IT IS CRITICAL THAT RISER P-4 WASTE LINE RUNS AS A CONTINUOUS STACK FROM THE FIRST FLOOR ALL THE WAY UP TO THE THIRD FLOOR CEILING AND THAT THE EXISTING 4TH LEVEL BATHROOM, 4TH LEVEL LAUNDRY ROOM, AND NEW 4TH LEVEL BATHROOM CONNECT TO THIS VERTICAL STACK IN THE 3RD LEVEL CEILING (SEE RISER DIAGRAM, SHEET P1.0). COORDINATE IN THE FIELD AS REQUIRED OR CONTACT ENGINEER FOR ASSISTANCE. CONNECT 3 4" CW AND 3 4" HW TO EXISTING DOMESTIC WATER RISER P-4 (1" EACH). VERIFY LOCATION AND SIZES IN THE FIELD. CONNECT 3 4" CW AND 3 4" HW TO EXISTING DOMESTIC WATER RISER P-4 (1" HOT, 1 1 4" COLD). VERIFY LOCATION AND SIZES IN THE FIELD. SHEET DETAIL NOTES: 1 2 3 4 5 6 7 CWB 4 3" REPLACE AND RELOCATE FIXTURES WITHIN THE EXISTING BATHROOMS AND RECONNECT TO EXISTING RISER P-5. NO ADDITIONAL FIXTURES IN THIS AREA. LV 1 WC 2 SH 3 REPLACE FIXTURES WITHIN THE EXISTING BATHROOM AND RECONNECT TO EXISTING RISER LOCATIONS. NO NEW FIXTURES ADDED IN THIS LOCATION. REPLACE FIXTURES WITHIN THE EXISTING BATHROOM AND RECONNECT TO EXISTING RISER LOCATIONS. NO NEW FIXTURES ADDED IN THIS LOCATION. REPLACE KITCHEN SINK AND RECONNECT TO EXISTING LOCATION. NO NEW FIXTURES ADDED IN THIS LOCATION. REMOVE CLOTHES WASHER AND CAP EXISTING PLUMBING LINES IN THIS LOCATION. REMOVE EXISTING LAV AND ROUTE EXISTING 1 2" HW, CW, AND 1 1 2" V LINES FROM THIS LOCATION TO NEW LAV. REPLACE FIXTURES WITHIN THE EXISTING BATHROOM AND RECONNECT TO EXISTING RISER LOCATIONS. NO NEW FIXTURES ADDED IN THIS LOCATION. LV 1 SH 3 APPROXIMATE LOCATION OF EXISTING 3" VENT RISER P-5. REROUTE VENT AS REQUIRED FOR NEW FLOORPLAN. 1 1 2" 2" 2" 2" 1 1 2" 2" CONNECT 2" WASTE FROM WASHER TO 3" COMMON HORIZONTAL WASTE LINE TO RISER P-5. SEE RISER DIAGRAM, SHEET P1.0. APPROXIMATE LOCATION OF 3" VENT RISER P-4. APPROXIMATE LOCATION OF EXISTING 3" WASTE AND 3" VENT RISER P-4. 5 CONNECT NEW 3" WASTE LINE INTO 3" WASTE STACK P-4. CONNECT NEW 2" VENT TO 3" VENT RISER OR TO 2" COMMON HORIZONTAL VENT FROM THE BATHROOM GROUP. APPROXIMATE LOCATION OF EXISTING 3" WASTE AND 3" VENT RISER P-5. 6 7 CONNECT 2" WASTE FROM SHOWER TO 3" COMMON HORIZONTAL WASTE LINE TO RISER P-5. SEE RISER DIAGRAM, SHEET P1.0. 3 4 " 3 4 " TOC AEC PLUMBING FLOORPLANS SCALE: 1/4" = 1'-0" P2.0 2 2 of www.aec-vail.com C40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620 Mechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 Fax: 970-748-8521 EGDrawn By: Checked By: DATE: ISSUE: 07/02/15 PERMIT AEC PROJECT #: NORTHWOODS UNIT 311 PLUMBING RISER REVIEW VAIL, COLORADO 81657 15057 An Office with LEEDâ„¢ Accredited Professionals NORTH THIRD LEVEL PLUMBING PLAN SCALE: 1/4" = 1'0" NORTH FOURTH LEVEL PLUMBING PLAN SCALE: 1/4" = 1'0" 08/03/15