HomeMy WebLinkAboutB15-0208_A003_1479324480.pdfW W
CR
CR D
CD NORLAKE
NBCF44/24-4
24
48
G
G
D
R G G DCC
H
1/3
1/3
1/3
1/3
1/3
1/3
DC
1/3
1/3
1/3
1/3
1/3
1/3
J
DCWHW
D CW HW CW
DCWHWJ
J
HWCW
CW
FD
FD
FD
FS
FS
FSU
J J J
FS
CW
U
FS
FS
CW CW
C
C
D
24
36
D
HW CW
FSH
C HW CW FS
D CW
HW 18
30
HWCW
HW 14 72
24
36
24
48
24
48
1830 18
42
J
CHEM
D
H
C
B
S
FS
101
DINING SOUTH
114
SOUTH PATIO
115
NORTH PATIO
102
TOWER
103
TOWER DINING
105
BAR
106
STAIR A
104
DINING NORTH
107
NORTH SERVICE
108
DINING NORTH EAST
?
?
110
EXIT HALL
111
MEN
112
WOMEN
113
STAIR B
30 SF/15 =
2 OCCUPANTS
170 SF/15 =
11.3
OCCUPANTS
90 SF/15 =
6 OCCUPANTS
PLUS 14'-8" LF/2 BENCH =
7.4 OCCUPANTS
210 SF/15 =
14 OCCUPANTS
110 SF/15 =
7.3 OCCUPANTS
71 SF/200 =
1 OCCUPANTS
140 SF/15 =
9.3 OCCUPANTS
PLUS 18 LF/2 = 9 OCCUPANTS
122 SF/15 =
8.1 OCCUPANTS
PLUS 26 LF/2 = 13 OCCUPANTS
84 SF/15 =
5.6 OCCUPANTS
181 SF/15 =
12 OCCUPANTS
PLUS 10' LF/2 BENCH =
5 OCCUPANTS
EXISTING SECOND EXIT
49 OCCUPANTS
REQ'D STAIR 49X.3 = 14.7"
PROPOSED STAIR 44"
ACCESS 49X.2 = 9.5"
PROPOSED ACCESS = 34"
RESTAURANT DINING LEVEL
TOTAL AREA 1620 SF
TOTAL INTERIOR 98 OCCUPANTS
TOTAL PATIO 13 OCCUPANTS
BASEMENT KITCHEN LEVEL
TOTAL AREA 1140 SF/200 =
6 TOTAL OCCUPANTS
MAIN ENTRY/EXIT
49 OCCUPANTS
ACCESS 49X.2 = 9.5"
PROPOSED ACCESS = 34"
1' to PL
BRIDGE STREET 25' ROW
GORE CREEK DRIVE 40' ROW
EXISTING EXTERIOR WALL TO REMAIN
BASEMENT KITCHEN LEVEL
TOTAL AREA 1140 SF/200 =
6 TOTAL OCCUPANTS
STAIR A
3 OCCUPANTS
STAIR 3X.3 = .9"
PROPOSED STAIR = 36"
STAIR B
3 OCCUPANTS
STAIR 3X.3 = .9"
PROPOSED STAIR = 36"
PROJECT
NUMBER:
PROJECT DATE:
SHEET TITLE:
SHEET NUMBER:
A003
143100
COMMISSARY
August 22,
2016
CODE ANALYSIS
232 BRIDGE
STREET,
VAIL, CO 81657
1/8" = 1'-0"
1 CODE PLAN LEVEL 01
1/8" = 1'-0"
2 CODE PLAN LEVEL 0 BASEMENT
N
N
PROJECT LOCATION
263 E Gore Creek Drive, Vail CO 81657
Parcel Number 210108229003
LEGAL DESCRIPTION:
LOTS C D AND E BLOCK 5 VAIL VILLAGE FIRST FILING
TOWN OF VAIL, EAGLE COUNTY, COLORADO
APPLICABLE CODES
2012 International Building Code w/ Local Amendments
Chapter 5-7 Per stamped Fire Protection Engineer letter dated 06.09.2015 by BCER group
• 2012 International Mechanical Code w/ Local Amendments
• 2012 International Plumbing Code
• 2012 International Energy Conservation Code w/ Local Amendments
• 2012 International Fuel & Gas Code w/ Local Amendments
• 2011 National Electric Code
• Accessibility: State Law crs 9-5 & ICC / ANSI A117.1-2003
Ground snow load 145 pounds per SF
Wind speed 90 mph (3 second gust) and Exposure B
Minimum frost depth 48"
BUILDING DESCRIPTION
The Grosuch Clock Tower Building in Vail is an existing building with a clock tower. The building has a basement,
first and second floor retail spaces, levels three through five include small offices (about 270 SF per level) in
the clock tower. The 505 sf Proposed addition to Bridge street facade.
ACTUAL BUILDING AREAS
Basement Level: Occupancy M, A2 Net Area 7500 sf
Street Level: Occupancy M, A2 Net Area 7537 sf PLUS 505 sf addition
Upper Level: Occupancy M, B Net Area 7560 sf
Clock Tower level 3: Occupancy B Net Area 340 sf
Clock Tower level 4: Occupancy B Net Area 340 sf
Clock Tower level 5: Occupancy B Net Area 340 sf
East Loft/mezzanine Office Space: Occupancy B Net Area 420 sf
Total Net [per Area Building definition]: 24542 sf
BUILDING CLASSIFICATION per Section 302
Section 303.3 MERCANTILE with existing allowance for non separated uses 508.3
[per the building official based on existing building code provision]
A-2, B and S1
Proposed scope of work Assembly Group A-2 Food Service
Chapter 5-7 Per stamped Fire Protection Engineer letter dated 06.09.2015 by BCER group
Type VA - NON SEPERATED A2, M AND B
MEANS OF EGRESS
Refer to adjacent code plan
ZONING
CC1
No proposed exterior modifications. Current patio revocable permit lease to be resigned by tenant
Proposed Tenant Finish Building Area/Occupant load:
1620 SF NET FIRST FLOOR A-2
1140 SF NET BASEMENT FLOOR A-2
104 TOTAL OCCUPANTS PLUS 13 OUTSIDE PATIO
Plumbing fixture calculations [Table 2902.1]:
-Water Closets: 1 required per 75 Male and Female. 104 interior occupants 13 patio occupants.
1 provided per 59 Male and 59 Female.
-Lavatories: 1 required per 200 Male and Female. 1 per provided.
-No drinking fountain required where beverage service is provided.
-Service sink provided.
20 FT FSD
12.5 FT FSD
NON RATED SMOKE SEPARATION BETWEEN A AND M
EXISTING M
RETAIL
SHADED AREA IS PROPOSED ADDITION
REVISION DATE
5 DD PRICING 02.04.15
6 FOR
CONSTRUCTION
06.16.15
17 PR NO 2 09.02.16
11/16/16