HomeMy WebLinkAboutB15-0208_A005_1479324480.pdf5/8" PLYWOOD
3 5/8" METAL STUD
5/8" PLYWOOD
METAL STUD, 3 5/8" WALL CAVITY,
PLYWOOD SUBSTRATE
W1
5/8" PLYWOOD,
1 1/2" METAL STUD,
5/8" PLYWOOD
METAL STUD, 1 1/2" WALL CAVITY,
PLYWOOD SUBSTRATE
W2
5/8" CEMENT BOARD ON [E] STUD
EXISTING STUD WALL, NEW
CEMENT BOARD SUBSTRATE
W9
1/2" CEMENT BOARD
3 5/8" METAL STUD
5/8" DENS GLASS
METAL STUD, 3 5/8" WALL CAVITY,
CEMENT BOARD/DENS GLASS
SUBSTRATE
W5
5/8" PLYWOOD,
3 5/8" METAL STUD,
5/8" GYP BOARD
METAL STUD, 3 5/8" WALL CAVITY,
PLYWOOD/GYP BOARD
SUBSTRATE
W3
5/8" GYP BOARD,
3 5/8" METAL STUD,
5/8" GYP BOARD
METAL STUD, 3 5/8" WALL CAVITY,
GYP BOARD SUBSTRATE
W4
1/2" PLYWOOD
EXISTING STUD WALL
5/8" CEMENT BOARD
EXISTING STUD WALL CAVITY,
PLYWOOD/CEMENT BOARD
SUBSTRATE
W6
5/8" PLYWOOD,
EXISTING STUD WALL,
5/8" PLYWOOD
EXISTING STUD WALL CAVITY,
PLYWOOD SUBSTRATE
W8
5/8" GYP BOARD
EXISTING STUD WALL
5/8" GYP BOARD
EXISTING STUD WALL CAVITY, GYP
BOARD/GYP BOARD SUBSTRATE
W7
5/8" GYP BOARD,
3 5/8" METAL STUD
*PROVIDE GLASS MATT AT WET AREAS
METAL STUD, 3 5/8 STUD CAVITY,
GYP BOARD SUBSTRATE
W10
1/2" PLYWOOD ON 7/8" METAL HAT
CHANNEL
METAL STUD, 7/8" STUD CAVITY,
PLYWOOD SUBSTRATE
W11
5/8" GYP BOARD ON 7/8" METAL HAT
CHANNEL
METAL STUD, 7/8" STUD CAVITY,
GYP BOARD SUBSTRATE
W12
1/2" PLYWOOD ON [E] METAL STUD
[E] METAL STUD, NEW PLYWOOD
SUBSTRATE
W13
1" TYPE "X" GYP,
2 1/2" CT STUD,
5/8" TYPE "X" GYP
SHAFT WALL 1 HR RATED GA WP
6800, METAL STUD, 2 1/2" METAL
STUD CAVITY, GYP BOARD
SUBSTRATE
W14
5/8" GYP BOARD ON [E] METAL STUD
[E] METAL STUD, NEW GYP BOARD
SUBSTRATE
W15
1/2" MDF ON [E] METAL STUD
[E] METAL STUD, NEW MDF
SUBSTRATE
W16
?
EXISTING WALL
W17
CLIMATE ZONE 6
OPAQUE THERMAL ENVELOPE TABLE C402.2
ROOF INSULATION R-49 [7.8" OF CLOSED CELL SPRAY FOAM INSULATION]
WALL INSULATION R-13 [3 1/2" FIBERGLASS BATT] + R-7.5ci [1.2" POLYISO FOAM BOARD]
BELOW GRADE WALLS R-7.5ci [1.5" FOAMULAR 150 XPS RIGID FOAM INSULATION - OWENS
CORNING OR SIMILAR]
HEATED FLOOR SLABS R-15 [3" FOAMULAR 250 XPS RIGID FOAM INSULATION - OWENS
CORNING OR SIMILAR]
VERTICAL FENESTRATION TABLE C402.3
OPERABLE DOORS U .43
ENTRY DOOR U .77
FIXED FENESTRATION U .36
2012 IECC MINIMUM REQUIREMENTS:
TS-1; ALUM. SHLUTER
TRANSITION STRIP
[CENTER BELOW DOORS]
TYPICAL DOOR
TS-2; ALUM. SHLUTER
TRANSITION STRIP
[CENTER BELOW DOORS]
TYPICAL DOOR
ADA SLOPE UP
W/ LEVELING
CONCRETE
TS-3; ALUM. SHLUTER
TRANSITION STRIP
[CENTER BELOW DOORS]
TYPICAL DOOR
ADA SLOPE UP
W/ LEVELING
CONCRETE
TS-4; ALUM. SHLUTER
TRANSITION STRIP ADA
SLOPED
[CENTER BELOW DOORS]
TYPICAL DOOR
TILE
RESILIENT
FLOORING
WOOD
RESILIENT
FLOORING
WOOD
TILE
CONCRETE
TILE
TYPICAL FLOOR TRANSITIONS:
CEILING ASSEMBLIES:
C-1
-2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL
SUSPENSION SYSTEM
-5/8" TYPE X GYP BOARD
C-2 -2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION
SYSTEM
-5/8" TYPE X GYP BOARD
-SMOOTH VENETIAN PLASTER FINISH
C-3 -2X4 SUSPENDED VINYL COATED GYPSUM BOARD TILES
[USG 3270 CLIMA PLUS OR SIMILAR IN 15/16" T GRID]
C-4 -T & G 1X6 SMOOTH KNOTTY CEDAR WOOD ON 5/8"
PLYWOOD SUBSTRATE CLEAR/DULL SHEEN FINISH
C-5
-2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION
SYSTEM
-5/8" GYP BOARD
-SANFOOT CUSTOM WHITE OAK PLAIN SAWN KNOTTY WOOD
VENEER WALLCOVERING
-1X6 STAINED KNOTTY ALDER SOLID WOOD @ 18" O.C.
C-6
-2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION
SYSTEM
-5/8" GYP BOARD
-STRETCHED FABRIC PANEL [WHISPER WALL OR SIMILAR]
MAHARAM CRISP 901860-005 QUAHAUY [CUT OUTS FOR LIGHT
FIXTURES]
-1X6 STAINED KNOTTY ALDER SOLID WOOD @ 18" O.C.
FRAMING VARIES RE: ARCH DETAILS
C-0
EXISTING TYPE X RATED GYPSUM BOARD CEILING TO BE
REMOVED & REPLACED
F-1
-RANDOMN CUT 1" FLAGSTONE QUARTZITE
[SMOOTH INSTALLATION]
-THICK MUDSET ON NEW CONCRETE SLAB [RE
STRUCTURAL] WITH RADIANT HEATING [RE
MECH] ON 3.5" RIGID FOAM INSULATION
BOARD ON 4" MIN RIGID GRANULAR FILL
-ENGINEERED 6" WIDE RUSTIC WHITE OAK ,
FIELD FINISH STAINED & OILED, FLOORING BY
ARRIGONI ON EXISTING PLYWOOD SUBSTRATE
-RADIANT HEAT [RE MECH] BETWEEN WOOD
JOISTS, INSULATE BELOW W DOUBLE BUBBLE
RE:STRUCUTRAL
FLOOR ASSEMBLIES:
-WALK OFF COCOA MATT BY MATS INC. TOP OF
MATT BRISTLES TO BE FLUSH WITH ADJACENT
FINISH FLOOR F-1
-TIGHT TO SIDE WALLS TUCKING UNDER WOOD
WALL FINISHES AND ENTRY DOOR THRESHOLD
-THICKSET MORTAR BED - OR WOOD FLOOR ON
SLEEPERS
-STRUCTURAL SLAB ON GRADE RE:STRUCTURAL
-INSULATION RE:DETAILS
RE:STRUCUTRAL
-1/4" RESILIENT FLOORING COLD WELDED
PROTECTAL DARK GREY EXISTING SUBSTRATE (VARIES)
-THIN SET TILE
-ON LIQUID WATER PROOFING/CRACK
SUPPRESION [REDGUARD OR SIM] ON EXISTING
BASEMENT CONC SLAB
EXISTING
-CONCRETE PAVERS - RE-GRADE SITE TO BE 2%
UP TO MAIN ENTRY DOOR NEW CONCRETE
PAVERS PER TOWN OF VAIL STANDARDS
-CAPCO MINERAL D PIRITE 2"X2" - FUSION
GROUT JOINT 1/16"
-RADIANT HEAT [RE MECH] BETWEEN WOOD
JOISTS, INSULATE BELOW W DOUBLE BUBBLE
F-2
F-3
F-4
F-5
F-6
F-7
COLD ROOF ASSEMBLY:
- 20 OZ COPPER STANDING SEAM 12"
O.C. SEAMS
-[2] LAYERS ICE AND WATER SHIELD ON
3/4" PLYWOOD
-2X4 STAGGERED SPACERS FOR AIR
CIRCULATION
-5/8" PLYWOOD
-FRAMING [RE:STRUCT]
-R-49 SPRAY CLOSED CELL CELLULOSE
INSULATION
-5/8" PLYWOOD
-60 MIL VAPOR BARRIER
-2X4 SPACERS FOR MEP LINES
-5/8" PLYWOOD
-FINISHED CEILING RE: RCP
-PROVIDE COPPER SOFFIT VENTS
RE:STRUCTURAL
ROOF ASSEMBLIES:
R-1
X-1
-7/8" WHITE 3 COAT CEMENTITIOUS
STUCCO TO MATCH EXISTING
-METAL LATH
-1.2" CARLISLE R2+ POLYISO FOAM
BOARD R-7.5ci [OR SIM]
-MOISTURE BARRIER
-1/2" EXTERIOR PLYWOOD SHEATHING
-6" METAL FRAMING
-CONT R-19 UNFACED BATT INSULATION
-60 MIL VAPOR BARRIER
-5/8" GYPSUM BOARD
EXTERIOR WALL ASSEMBLIES:
EXTERIOR
INTERIOR
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
X-2
EXTERIOR
INTERIOR
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
X-3
EXTERIOR
INTERIOR
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
X-4
EXTERIOR
INTERIOR
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
X-5
- 1.5" XPS 150 FOAM INSULATION BOARD
-DRAINAGE BOARD
-SPRAY APPLIED WATERPROOFING
-CONCRETE FOUNDATION [RE:
STRUCTURAL]
EXTERIOR
INTERIOR
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
- 7/8" ROUGH SAWN STAINED CEDAR
SEALED
-3/4" PLYWOOD
-1.2" CARLISLE R2+ POLYISO FOAM BOARD
R-7.5ci [OR SIM]
-MOISTURE BARRIER
-5/8" DENSGLASS SHEATHING
-6" METAL FRAMING
-CONT R-19 UNFACED BATT INSULATION
-60 MIL VAPOR BARRIER
-5/8" GYPSUM BOARD
- 7/8" ROUGH SAWN STAINED CEDAR
SEALED
-3/4" PLYWOOD
-MOISTURE BARRIER
-5/8" DENSGLASS SHEATHING
-6" METAL FRAMING
-CONT R-19 UNFACED BATT INSULATION
-60 MIL VAPOR BARRIER
-5/8" GYPSUM BOARD
- FULL STONE VENEER GALLEGOS ASPEN
GRANITE TUMBLED HIGHLANDS
-MASONRY HANGERS AND WEEPS
-DRAINAGE BOARD
-1.2" CARLISLE R2+ POLYISO FOAM BOARD
R-7.5ci [OR SIM]
-MOISTURE BARRIER
-1/2" EXTERIOR PLYWOOD SHEATHING
-6" METAL FRAMING
-CONT R-19 UNFACED BATT INSULATION
-60 MIL VAPOR BARRIER
-5/8" GYPSUM BOARD
GC TO PROVIDE FULL SCALE MOCK UP 3'
WIDE MINIMUM FOR OWNER APPROVAL
PRIOR TO ORDERING MATERIALS - ONSITE
OR IN GORSUCH WAREHOUSE
X-6
- THIN STONE VENEER GALLEGOS ASPEN
GRANITE TUMBLED HIGHLANDS TO TOP OF
VAIL PAVERS
-SCRATCH COAT ON EXPANDED METAL
LATH
-DRAINAGE BOARD
-SPRAY APPLIED WATERPROOFING
-[E] CONCRETE WALL
-SPRAY APPLIED WATERPROOFING
-DRAINAGE BOARD
-SCRATCH COAT ON EXPANDED METAL
LATH
- THIN STONE VENEER GALLEGOS ASPEN
GRANITE TUMBLED HIGHLANDS TO TOP OF
NEW CONCRETE PATIO SLAB
GC TO PROVIDE FULL SCALE MOCK UP 3'
WIDE MINIMUM FOR OWNER APPROVAL
PRIOR TO ORDERING MATERIALS
EXTERIOR
NEW EXTERIOR PATIO
*RE:ARCH DETAILS FOR HEAD AND SILL DETAILS
SILL SEAL TYP. BASE OF WALL FRAMED
EXTERIOR WALLS
3/4" 1 1/8"
1 5/8"
2" 2"
W-2 WALL PANELING TYPICAL DETAIL:
OAK TRIM BY MILLWORKER
ARRIGONI INSET PANEL
*WALL BASE DETAIL GENERAL NOTES:
-STUD SIZE VARIES REFER TO WALL SCHEDULE FOR STUD SIZE.
-REFER TO INTERIOR ELEVATIONS FOR WALL FINISH.
-REFER TO PLAN FOR INSULATION LOCATIONS.
W1A
WALL TYPE: DEFINES STUD SIZE AND MATERIAL & SUBSTRATE THICKNESS AND MATERIAL
BASE DETAIL TYPE: DEFINES BASE CONDITION
1'-0" AFF
1'-0" AFF
A B C D E
*WALL BASE DETAIL GENERAL NOTES:
-STUD SIZE VARIES REFER TO WALL SCHEDULE FOR STUD SIZE.
-REFER TO INTERIOR ELEVATIONS FOR WALL FINISH.
-REFER TO PLAN FOR INSULATION LOCATIONS.
INTERIOR WALL ASSEMBLIES:
1. MIN BASE MATERIAL FOR ALL INTERIOR METAL FRAMING IS TO BE PER SSMA
REQUIREMENTS OR AS REQUIRED FOR INSTALLATION OR SPECIFIED BY STRUCTURAL
ENGINEER
2. PROVIDE FRT PLYWOOD BLOCKING ALLOWANCE FOR RESTROOMS AND KITCHEN
AREAS. CONTACT KITCHEN DESIGNER OR PLYWOOD BLOCKING REQUIRED FOR WALL
HUNG EQUIPMENT.
3. REFER TO ELEVATIONS AND SECTIONS FOR HEIGHTS OF WALL FINISHES AND WALL
SUBSTRATE SPECIFIC TO FINISH
4. ALL FRP WALLS TO HAVE; 1/2" CEMENT BOARD TO 12" AFF AT WET AREAS, UNO.
5. ALL CERAMIC WALL TILE WALLS TO HAVE; TILE BACKER BOARD, GLASS FACED OR
CEMENT BOARD.
6. ALL WOOD PANELED WALLS TO HAVE; 1/2" PLYWOOD SUBSTRATE.
7. ALL RESTROOM WALLS & CEILING TO HAVE UNFACED R-13 BATT INSULATION.
8. ALL DIMENSION ARE TO FINISH FACE OF WALL TYPE SUBSTRATE
WALL TYPE NOTES:
PROJECT
NUMBER:
PROJECT DATE:
SHEET TITLE:
SHEET NUMBER:
A005
143100
COMMISSARY
August 22,
2016
ASSEMBLIES & SCHEDULES
232 BRIDGE STREET, VAIL, CO 81657
REVISION DATE
6 FOR
CONSTRUCTION
06.16.15
17 PR NO 2 09.02.16
11/16/16