HomeMy WebLinkAboutB15-0208_A005_1479324480.pdf5/8" PLYWOOD 3 5/8" METAL STUD 5/8" PLYWOOD METAL STUD, 3 5/8" WALL CAVITY, PLYWOOD SUBSTRATE W1 5/8" PLYWOOD, 1 1/2" METAL STUD, 5/8" PLYWOOD METAL STUD, 1 1/2" WALL CAVITY, PLYWOOD SUBSTRATE W2 5/8" CEMENT BOARD ON [E] STUD EXISTING STUD WALL, NEW CEMENT BOARD SUBSTRATE W9 1/2" CEMENT BOARD 3 5/8" METAL STUD 5/8" DENS GLASS METAL STUD, 3 5/8" WALL CAVITY, CEMENT BOARD/DENS GLASS SUBSTRATE W5 5/8" PLYWOOD, 3 5/8" METAL STUD, 5/8" GYP BOARD METAL STUD, 3 5/8" WALL CAVITY, PLYWOOD/GYP BOARD SUBSTRATE W3 5/8" GYP BOARD, 3 5/8" METAL STUD, 5/8" GYP BOARD METAL STUD, 3 5/8" WALL CAVITY, GYP BOARD SUBSTRATE W4 1/2" PLYWOOD EXISTING STUD WALL 5/8" CEMENT BOARD EXISTING STUD WALL CAVITY, PLYWOOD/CEMENT BOARD SUBSTRATE W6 5/8" PLYWOOD, EXISTING STUD WALL, 5/8" PLYWOOD EXISTING STUD WALL CAVITY, PLYWOOD SUBSTRATE W8 5/8" GYP BOARD EXISTING STUD WALL 5/8" GYP BOARD EXISTING STUD WALL CAVITY, GYP BOARD/GYP BOARD SUBSTRATE W7 5/8" GYP BOARD, 3 5/8" METAL STUD *PROVIDE GLASS MATT AT WET AREAS METAL STUD, 3 5/8 STUD CAVITY, GYP BOARD SUBSTRATE W10 1/2" PLYWOOD ON 7/8" METAL HAT CHANNEL METAL STUD, 7/8" STUD CAVITY, PLYWOOD SUBSTRATE W11 5/8" GYP BOARD ON 7/8" METAL HAT CHANNEL METAL STUD, 7/8" STUD CAVITY, GYP BOARD SUBSTRATE W12 1/2" PLYWOOD ON [E] METAL STUD [E] METAL STUD, NEW PLYWOOD SUBSTRATE W13 1" TYPE "X" GYP, 2 1/2" CT STUD, 5/8" TYPE "X" GYP SHAFT WALL 1 HR RATED GA WP 6800, METAL STUD, 2 1/2" METAL STUD CAVITY, GYP BOARD SUBSTRATE W14 5/8" GYP BOARD ON [E] METAL STUD [E] METAL STUD, NEW GYP BOARD SUBSTRATE W15 1/2" MDF ON [E] METAL STUD [E] METAL STUD, NEW MDF SUBSTRATE W16 ? EXISTING WALL W17 CLIMATE ZONE 6 OPAQUE THERMAL ENVELOPE TABLE C402.2 ROOF INSULATION R-49 [7.8" OF CLOSED CELL SPRAY FOAM INSULATION] WALL INSULATION R-13 [3 1/2" FIBERGLASS BATT] + R-7.5ci [1.2" POLYISO FOAM BOARD] BELOW GRADE WALLS R-7.5ci [1.5" FOAMULAR 150 XPS RIGID FOAM INSULATION - OWENS CORNING OR SIMILAR] HEATED FLOOR SLABS R-15 [3" FOAMULAR 250 XPS RIGID FOAM INSULATION - OWENS CORNING OR SIMILAR] VERTICAL FENESTRATION TABLE C402.3 OPERABLE DOORS U .43 ENTRY DOOR U .77 FIXED FENESTRATION U .36 2012 IECC MINIMUM REQUIREMENTS: TS-1; ALUM. SHLUTER TRANSITION STRIP [CENTER BELOW DOORS] TYPICAL DOOR TS-2; ALUM. SHLUTER TRANSITION STRIP [CENTER BELOW DOORS] TYPICAL DOOR ADA SLOPE UP W/ LEVELING CONCRETE TS-3; ALUM. SHLUTER TRANSITION STRIP [CENTER BELOW DOORS] TYPICAL DOOR ADA SLOPE UP W/ LEVELING CONCRETE TS-4; ALUM. SHLUTER TRANSITION STRIP ADA SLOPED [CENTER BELOW DOORS] TYPICAL DOOR TILE RESILIENT FLOORING WOOD RESILIENT FLOORING WOOD TILE CONCRETE TILE TYPICAL FLOOR TRANSITIONS: CEILING ASSEMBLIES: C-1 -2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION SYSTEM -5/8" TYPE X GYP BOARD C-2 -2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION SYSTEM -5/8" TYPE X GYP BOARD -SMOOTH VENETIAN PLASTER FINISH C-3 -2X4 SUSPENDED VINYL COATED GYPSUM BOARD TILES [USG 3270 CLIMA PLUS OR SIMILAR IN 15/16" T GRID] C-4 -T & G 1X6 SMOOTH KNOTTY CEDAR WOOD ON 5/8" PLYWOOD SUBSTRATE CLEAR/DULL SHEEN FINISH C-5 -2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION SYSTEM -5/8" GYP BOARD -SANFOOT CUSTOM WHITE OAK PLAIN SAWN KNOTTY WOOD VENEER WALLCOVERING -1X6 STAINED KNOTTY ALDER SOLID WOOD @ 18" O.C. C-6 -2X4 USG RIGID X [OR SIM] 1 1/2" METAL DRYWALL SUSPENSION SYSTEM -5/8" GYP BOARD -STRETCHED FABRIC PANEL [WHISPER WALL OR SIMILAR] MAHARAM CRISP 901860-005 QUAHAUY [CUT OUTS FOR LIGHT FIXTURES] -1X6 STAINED KNOTTY ALDER SOLID WOOD @ 18" O.C. FRAMING VARIES RE: ARCH DETAILS C-0 EXISTING TYPE X RATED GYPSUM BOARD CEILING TO BE REMOVED & REPLACED F-1 -RANDOMN CUT 1" FLAGSTONE QUARTZITE [SMOOTH INSTALLATION] -THICK MUDSET ON NEW CONCRETE SLAB [RE STRUCTURAL] WITH RADIANT HEATING [RE MECH] ON 3.5" RIGID FOAM INSULATION BOARD ON 4" MIN RIGID GRANULAR FILL -ENGINEERED 6" WIDE RUSTIC WHITE OAK , FIELD FINISH STAINED & OILED, FLOORING BY ARRIGONI ON EXISTING PLYWOOD SUBSTRATE -RADIANT HEAT [RE MECH] BETWEEN WOOD JOISTS, INSULATE BELOW W DOUBLE BUBBLE RE:STRUCUTRAL FLOOR ASSEMBLIES: -WALK OFF COCOA MATT BY MATS INC. TOP OF MATT BRISTLES TO BE FLUSH WITH ADJACENT FINISH FLOOR F-1 -TIGHT TO SIDE WALLS TUCKING UNDER WOOD WALL FINISHES AND ENTRY DOOR THRESHOLD -THICKSET MORTAR BED - OR WOOD FLOOR ON SLEEPERS -STRUCTURAL SLAB ON GRADE RE:STRUCTURAL -INSULATION RE:DETAILS RE:STRUCUTRAL -1/4" RESILIENT FLOORING COLD WELDED PROTECTAL DARK GREY EXISTING SUBSTRATE (VARIES) -THIN SET TILE -ON LIQUID WATER PROOFING/CRACK SUPPRESION [REDGUARD OR SIM] ON EXISTING BASEMENT CONC SLAB EXISTING -CONCRETE PAVERS - RE-GRADE SITE TO BE 2% UP TO MAIN ENTRY DOOR NEW CONCRETE PAVERS PER TOWN OF VAIL STANDARDS -CAPCO MINERAL D PIRITE 2"X2" - FUSION GROUT JOINT 1/16" -RADIANT HEAT [RE MECH] BETWEEN WOOD JOISTS, INSULATE BELOW W DOUBLE BUBBLE F-2 F-3 F-4 F-5 F-6 F-7 COLD ROOF ASSEMBLY: - 20 OZ COPPER STANDING SEAM 12" O.C. SEAMS -[2] LAYERS ICE AND WATER SHIELD ON 3/4" PLYWOOD -2X4 STAGGERED SPACERS FOR AIR CIRCULATION -5/8" PLYWOOD -FRAMING [RE:STRUCT] -R-49 SPRAY CLOSED CELL CELLULOSE INSULATION -5/8" PLYWOOD -60 MIL VAPOR BARRIER -2X4 SPACERS FOR MEP LINES -5/8" PLYWOOD -FINISHED CEILING RE: RCP -PROVIDE COPPER SOFFIT VENTS RE:STRUCTURAL ROOF ASSEMBLIES: R-1 X-1 -7/8" WHITE 3 COAT CEMENTITIOUS STUCCO TO MATCH EXISTING -METAL LATH -1.2" CARLISLE R2+ POLYISO FOAM BOARD R-7.5ci [OR SIM] -MOISTURE BARRIER -1/2" EXTERIOR PLYWOOD SHEATHING -6" METAL FRAMING -CONT R-19 UNFACED BATT INSULATION -60 MIL VAPOR BARRIER -5/8" GYPSUM BOARD EXTERIOR WALL ASSEMBLIES: EXTERIOR INTERIOR *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS X-2 EXTERIOR INTERIOR *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS X-3 EXTERIOR INTERIOR *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS X-4 EXTERIOR INTERIOR *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS X-5 - 1.5" XPS 150 FOAM INSULATION BOARD -DRAINAGE BOARD -SPRAY APPLIED WATERPROOFING -CONCRETE FOUNDATION [RE: STRUCTURAL] EXTERIOR INTERIOR *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS - 7/8" ROUGH SAWN STAINED CEDAR SEALED -3/4" PLYWOOD -1.2" CARLISLE R2+ POLYISO FOAM BOARD R-7.5ci [OR SIM] -MOISTURE BARRIER -5/8" DENSGLASS SHEATHING -6" METAL FRAMING -CONT R-19 UNFACED BATT INSULATION -60 MIL VAPOR BARRIER -5/8" GYPSUM BOARD - 7/8" ROUGH SAWN STAINED CEDAR SEALED -3/4" PLYWOOD -MOISTURE BARRIER -5/8" DENSGLASS SHEATHING -6" METAL FRAMING -CONT R-19 UNFACED BATT INSULATION -60 MIL VAPOR BARRIER -5/8" GYPSUM BOARD - FULL STONE VENEER GALLEGOS ASPEN GRANITE TUMBLED HIGHLANDS -MASONRY HANGERS AND WEEPS -DRAINAGE BOARD -1.2" CARLISLE R2+ POLYISO FOAM BOARD R-7.5ci [OR SIM] -MOISTURE BARRIER -1/2" EXTERIOR PLYWOOD SHEATHING -6" METAL FRAMING -CONT R-19 UNFACED BATT INSULATION -60 MIL VAPOR BARRIER -5/8" GYPSUM BOARD GC TO PROVIDE FULL SCALE MOCK UP 3' WIDE MINIMUM FOR OWNER APPROVAL PRIOR TO ORDERING MATERIALS - ONSITE OR IN GORSUCH WAREHOUSE X-6 - THIN STONE VENEER GALLEGOS ASPEN GRANITE TUMBLED HIGHLANDS TO TOP OF VAIL PAVERS -SCRATCH COAT ON EXPANDED METAL LATH -DRAINAGE BOARD -SPRAY APPLIED WATERPROOFING -[E] CONCRETE WALL -SPRAY APPLIED WATERPROOFING -DRAINAGE BOARD -SCRATCH COAT ON EXPANDED METAL LATH - THIN STONE VENEER GALLEGOS ASPEN GRANITE TUMBLED HIGHLANDS TO TOP OF NEW CONCRETE PATIO SLAB GC TO PROVIDE FULL SCALE MOCK UP 3' WIDE MINIMUM FOR OWNER APPROVAL PRIOR TO ORDERING MATERIALS EXTERIOR NEW EXTERIOR PATIO *RE:ARCH DETAILS FOR HEAD AND SILL DETAILS SILL SEAL TYP. BASE OF WALL FRAMED EXTERIOR WALLS 3/4" 1 1/8" 1 5/8" 2" 2" W-2 WALL PANELING TYPICAL DETAIL: OAK TRIM BY MILLWORKER ARRIGONI INSET PANEL *WALL BASE DETAIL GENERAL NOTES: -STUD SIZE VARIES REFER TO WALL SCHEDULE FOR STUD SIZE. -REFER TO INTERIOR ELEVATIONS FOR WALL FINISH. -REFER TO PLAN FOR INSULATION LOCATIONS. W1A WALL TYPE: DEFINES STUD SIZE AND MATERIAL & SUBSTRATE THICKNESS AND MATERIAL BASE DETAIL TYPE: DEFINES BASE CONDITION 1'-0" AFF 1'-0" AFF A B C D E *WALL BASE DETAIL GENERAL NOTES: -STUD SIZE VARIES REFER TO WALL SCHEDULE FOR STUD SIZE. -REFER TO INTERIOR ELEVATIONS FOR WALL FINISH. -REFER TO PLAN FOR INSULATION LOCATIONS. INTERIOR WALL ASSEMBLIES: 1. MIN BASE MATERIAL FOR ALL INTERIOR METAL FRAMING IS TO BE PER SSMA REQUIREMENTS OR AS REQUIRED FOR INSTALLATION OR SPECIFIED BY STRUCTURAL ENGINEER 2. PROVIDE FRT PLYWOOD BLOCKING ALLOWANCE FOR RESTROOMS AND KITCHEN AREAS. CONTACT KITCHEN DESIGNER OR PLYWOOD BLOCKING REQUIRED FOR WALL HUNG EQUIPMENT. 3. REFER TO ELEVATIONS AND SECTIONS FOR HEIGHTS OF WALL FINISHES AND WALL SUBSTRATE SPECIFIC TO FINISH 4. ALL FRP WALLS TO HAVE; 1/2" CEMENT BOARD TO 12" AFF AT WET AREAS, UNO. 5. ALL CERAMIC WALL TILE WALLS TO HAVE; TILE BACKER BOARD, GLASS FACED OR CEMENT BOARD. 6. ALL WOOD PANELED WALLS TO HAVE; 1/2" PLYWOOD SUBSTRATE. 7. ALL RESTROOM WALLS & CEILING TO HAVE UNFACED R-13 BATT INSULATION. 8. ALL DIMENSION ARE TO FINISH FACE OF WALL TYPE SUBSTRATE WALL TYPE NOTES: PROJECT NUMBER: PROJECT DATE: SHEET TITLE: SHEET NUMBER: A005 143100 COMMISSARY August 22, 2016 ASSEMBLIES & SCHEDULES 232 BRIDGE STREET, VAIL, CO 81657 REVISION DATE 6 FOR CONSTRUCTION 06.16.15 17 PR NO 2 09.02.16 11/16/16