HomeMy WebLinkAboutB15-0208_A601_1479324480.pdfB2
RE:STRUCTURAL
12"
12"
F-1
PROVIDE ALUM SCHLUTER
TRANSITION BETWEEN FINISH
FLOOR MATERIALS
A1
F-1
CONCRETE SLAB
RE:STRUCTURAL
RIGID INSULATION
CONCRETE FOUNDATION WALL
RE:STRUCTURAL
STONE BENCH
W-9
X-6
X-5
SIM
3 1/2"
STONE CAP TO MATCH
PATIO CAP
2'-0"
1'-7"
3/4"
3/4"
4"
3/4"
SHIM
1/4"
3/4"
1 1/4"
7/8"
3"
W-8
RIGID INSULATION
VAPOR BARRIER
COPPER SILL FLASHING
BACKER ROD AND SEALANT
CAULK
4"
7" 3/4"
1 1/2"
1'-2 3/4"
SILL 1' - 2"
AFF
LINE OF 6"X4" HSS COLUMN BEYOND
BACKER ROD AND SEALANT
5 1/2"
A1
1'-0"
A601
15
A601
16 4 1/2" +/-
4 1/2" +/-
1/2" STEEL ROD
CURTAIN RAIL
W-3
LINE OF 6"X4" HSS
COLUMN BEYOND
B.O. TRIM 7' - 6"
T.O. TRIM 8' - 6"
AFF
AFF
B.O. STEEL 7' - 10"
AFF
3/4"
3/4"
3/4"
3/4"
4"
3/4"
SHIM
1/4"
3/4"
1 1/4"
7/8"
W-8
FLASHING
SEALANT AND
BACKER ROD
DRIP EDGE +
FLASHING
RIGID
INSULATION
VAPOR
BARRIER
A1
W-3
SILL SEAL TYP. BASE OF
WALL FRAMED EXTERIOR
WALLS
CONT SPRAY APPLIED
WATERPROOFING
J METAL WEEP
SCREED @
STUCCO BASE
6"
6"
STUCCO
RIGID
INSULATION
SEE PLAN DETAILS FOR DIMENSIONS
A1
R-1
STAINED CEDAR TO MATCH
FINISH AND COLOR OF EXISTING
BUILDING TRIM WORK
VARIES
C-4
W-3
VARIES
C-4
CONT DRIP EDGE
COPPER HEAD
FLASHING
W/BACKER ROD &
SEALANT
3"
FINISH FACE
OF 4"X6" HSS
COLUMN
BEYOND
END OF HEAVY
TIMBER BEAM
3/4"
FRAME DOWN FAR ENOUGH
TO COVER STRUCTURAL
BUCKETS
CLOSED CELL SPRAY FOAM
INSULATION
3/4"
3/4"
4"
3/4" SHIM
1/4"
3/4"
1 1/4"
7/8"
A1
RE:STRUCTURAL
3'-3"
1'-0"
2'-6"
8" 1 1/2"
CONCRETE FOUNDATION WALL
RE:STRUCTURAL
RIGID INSULATION
1.2
F-1
QUARZITE STONE CAP
NEW STONE WALL
4"
7/8"
1/8"
3/4"
4"
3/4"
3/4"
W-8 WOOD TRIM
SHIM
CAULK
W-4 WOOD TRIM
CLOSED CELL
SPRAY FOAM
INSULATION
VAPOR BARRIER
SILL SEAL
SILL 1' - 2"
AFF
1.2
R-1
1 3/4"
1 1/2"
4"
3/4"
3/4"
W-8 WOOD TRIM
SHIM
CAULK
W-4 WOOD TRIM
3/4"
3/4"
6 3/4"
CLOSED CELL
SPRAY FOAM
INSULATION
B
CASING BEAD (WEEP HOLES REQ'D)
NEW STUCCO TO MATCH EXISTING
[E] REMOVE EXISTING FOR NEW
WATERPROOFING AND FLASHING]
METAL COUNTER FLASHING
STUCCO STOPS ARE NOT CONSIDERED
COUNTER FLASHING
SHEET METAL FLASHING
HOOKED TO 'Z' CLOSURES AND FASTENED TO
WALL
STANDING SEAM METAL ROOF BREAD PANNED
AT TERMINATION AND DRAG LOAD FASTENED
W/ COMPATIBLE NON-CORROSIVE FASTENERS
ICE AND WATER SHIELD TO CONTINUE UP
[E] WALL BEHIND STUCCO FOR A MIN OF 12"
ABOVE THE ROOF
5.8
COPPER FLASHED SILL
SLOPED W/DRIP EDGE
3/4"
CAULK
BACKER ROD & SEALANT
W-8
VAPOR BARRIER
CLOSED CELL SPRAY
FOAM INSULATION
RIGID INSULATION
1 1/4"
7/8" 1 1/4"
3/4"
2" 2"
3/4"
3/4"
CAULK
W-3
BACKER ROD
AND SEALANT
FLASHING
W-8
RIGID INSULATION
VAPOR BARRIER
FLASHING
DRIP EDGE
VAPOR BARRIER
BACKEROD AND SEALANT
W-3
W-8
RIGID INSULATION
CAULK
3 2.9
NEW COPPER GUTTER
KN-16
R-1
VARIES
C-4
VARIES
C-4
2X12 FASCIA NAILER
STAINED CEDAR TO MATCH
FINISH AND COLOR OF EXISTING
BUILDING TRIM WORK
X-1
CONT DRIP EDGE FLASHING
1'-9 3/4"
3.8
3.5
STRUCTURAL BUCKETS
FRAME DOWN TO
COVER BUCKETS
LOWER WINDOWS
ACCORDINGLY AND
DECREASE SIZE
EXTENTS OF FRAMING
TO MATCH ROOF
SLOPE
TYPICAL CONDITION AT ALL TOWER WINDOWS
PROJECT
NUMBER:
PROJECT DATE:
SHEET TITLE:
SHEET NUMBER:
A601
143100
COMMISSARY
August 22,
2016
EXTERIOR DETAILS
232 BRIDGE STREET, VAIL, CO 81657
1 1/2" = 1'-0"
2
SLAB @ EXISTING BUILDING DETAIL
1 1/2" = 1'-0" 5
TOWER WINDOW SILL/BASE DETAIL
1 1/2" = 1'-0"
6
TOWER WINDOW SILL DETAIL
1 1/2" = 1'-0"
9
TOWER WALL BASE DETAIL
1 1/2" = 1'-0"
7
TOWER WINDOW HEAD DETAIL
1 1/2" = 1'-0"
1
FOOTER DETAIL OFFSET
1 1/2" = 1'-0" 12
NORTH WINDOW WOOD SILL DETAIL
1 1/2" = 1'-0" 3
NORTH SERVICE WINDOW EAVE DETAIL
GENERAL NOTE FOR ALL WINDOW AND DOOR INSTALLATIONS:
· PROVIDE BACKEROD & SEALANT AT ALL WINDOW CONNECTIONS TO DISSIMILAR MATERIALS
· PROVIDE SELF ADHERED FLASHING AT ALL WINDOW/DOOR OPENINGS
· PROVIDE COPPER THRU/DRIP FLASHING AT ALL WINDOW SILLS AND HEADS
· PROVIDE J METAL WEEP SCREED AT BASE OF ALL STUCCO WALLS
· PROVIDE WEEP AT BASE OF STONE WALLS
3" = 1'-0"
18
TYP ROOF TO E BLDG DETAIL
3" = 1'-0"
17
ENTRY WALL CAP DETAIL
3" = 1'-0"
15
DETAIL @ TOWER WINDOW SILL TYP
3" = 1'-0"
16
DETAIL@ TOWER WINDOW HEAD TYP
1 1/2" = 1'-0"
13
DETAIL AT TOWER ROOF FASCIA
REVISION DATE
6 FOR
CONSTRUCTION
06.16.15
7 PR NO 1 03.04.16
16 ASI-01 05.25.16
17 PR NO 2 09.02.16
1 1/2" = 1'-0"
4
EXTERIOR DETAIL @ TOWER WINDOW HEADS
11/16/16