Loading...
HomeMy WebLinkAboutB15-0208_A601_1479324480.pdfB2 RE:STRUCTURAL 12" 12" F-1 PROVIDE ALUM SCHLUTER TRANSITION BETWEEN FINISH FLOOR MATERIALS A1 F-1 CONCRETE SLAB RE:STRUCTURAL RIGID INSULATION CONCRETE FOUNDATION WALL RE:STRUCTURAL STONE BENCH W-9 X-6 X-5 SIM 3 1/2" STONE CAP TO MATCH PATIO CAP 2'-0" 1'-7" 3/4" 3/4" 4" 3/4" SHIM 1/4" 3/4" 1 1/4" 7/8" 3" W-8 RIGID INSULATION VAPOR BARRIER COPPER SILL FLASHING BACKER ROD AND SEALANT CAULK 4" 7" 3/4" 1 1/2" 1'-2 3/4" SILL 1' - 2" AFF LINE OF 6"X4" HSS COLUMN BEYOND BACKER ROD AND SEALANT 5 1/2" A1 1'-0" A601 15 A601 16 4 1/2" +/- 4 1/2" +/- 1/2" STEEL ROD CURTAIN RAIL W-3 LINE OF 6"X4" HSS COLUMN BEYOND B.O. TRIM 7' - 6" T.O. TRIM 8' - 6" AFF AFF B.O. STEEL 7' - 10" AFF 3/4" 3/4" 3/4" 3/4" 4" 3/4" SHIM 1/4" 3/4" 1 1/4" 7/8" W-8 FLASHING SEALANT AND BACKER ROD DRIP EDGE + FLASHING RIGID INSULATION VAPOR BARRIER A1 W-3 SILL SEAL TYP. BASE OF WALL FRAMED EXTERIOR WALLS CONT SPRAY APPLIED WATERPROOFING J METAL WEEP SCREED @ STUCCO BASE 6" 6" STUCCO RIGID INSULATION SEE PLAN DETAILS FOR DIMENSIONS A1 R-1 STAINED CEDAR TO MATCH FINISH AND COLOR OF EXISTING BUILDING TRIM WORK VARIES C-4 W-3 VARIES C-4 CONT DRIP EDGE COPPER HEAD FLASHING W/BACKER ROD & SEALANT 3" FINISH FACE OF 4"X6" HSS COLUMN BEYOND END OF HEAVY TIMBER BEAM 3/4" FRAME DOWN FAR ENOUGH TO COVER STRUCTURAL BUCKETS CLOSED CELL SPRAY FOAM INSULATION 3/4" 3/4" 4" 3/4" SHIM 1/4" 3/4" 1 1/4" 7/8" A1 RE:STRUCTURAL 3'-3" 1'-0" 2'-6" 8" 1 1/2" CONCRETE FOUNDATION WALL RE:STRUCTURAL RIGID INSULATION 1.2 F-1 QUARZITE STONE CAP NEW STONE WALL 4" 7/8" 1/8" 3/4" 4" 3/4" 3/4" W-8 WOOD TRIM SHIM CAULK W-4 WOOD TRIM CLOSED CELL SPRAY FOAM INSULATION VAPOR BARRIER SILL SEAL SILL 1' - 2" AFF 1.2 R-1 1 3/4" 1 1/2" 4" 3/4" 3/4" W-8 WOOD TRIM SHIM CAULK W-4 WOOD TRIM 3/4" 3/4" 6 3/4" CLOSED CELL SPRAY FOAM INSULATION B CASING BEAD (WEEP HOLES REQ'D) NEW STUCCO TO MATCH EXISTING [E] REMOVE EXISTING FOR NEW WATERPROOFING AND FLASHING] METAL COUNTER FLASHING STUCCO STOPS ARE NOT CONSIDERED COUNTER FLASHING SHEET METAL FLASHING HOOKED TO 'Z' CLOSURES AND FASTENED TO WALL STANDING SEAM METAL ROOF BREAD PANNED AT TERMINATION AND DRAG LOAD FASTENED W/ COMPATIBLE NON-CORROSIVE FASTENERS ICE AND WATER SHIELD TO CONTINUE UP [E] WALL BEHIND STUCCO FOR A MIN OF 12" ABOVE THE ROOF 5.8 COPPER FLASHED SILL SLOPED W/DRIP EDGE 3/4" CAULK BACKER ROD & SEALANT W-8 VAPOR BARRIER CLOSED CELL SPRAY FOAM INSULATION RIGID INSULATION 1 1/4" 7/8" 1 1/4" 3/4" 2" 2" 3/4" 3/4" CAULK W-3 BACKER ROD AND SEALANT FLASHING W-8 RIGID INSULATION VAPOR BARRIER FLASHING DRIP EDGE VAPOR BARRIER BACKEROD AND SEALANT W-3 W-8 RIGID INSULATION CAULK 3 2.9 NEW COPPER GUTTER KN-16 R-1 VARIES C-4 VARIES C-4 2X12 FASCIA NAILER STAINED CEDAR TO MATCH FINISH AND COLOR OF EXISTING BUILDING TRIM WORK X-1 CONT DRIP EDGE FLASHING 1'-9 3/4" 3.8 3.5 STRUCTURAL BUCKETS FRAME DOWN TO COVER BUCKETS LOWER WINDOWS ACCORDINGLY AND DECREASE SIZE EXTENTS OF FRAMING TO MATCH ROOF SLOPE TYPICAL CONDITION AT ALL TOWER WINDOWS PROJECT NUMBER: PROJECT DATE: SHEET TITLE: SHEET NUMBER: A601 143100 COMMISSARY August 22, 2016 EXTERIOR DETAILS 232 BRIDGE STREET, VAIL, CO 81657 1 1/2" = 1'-0" 2 SLAB @ EXISTING BUILDING DETAIL 1 1/2" = 1'-0" 5 TOWER WINDOW SILL/BASE DETAIL 1 1/2" = 1'-0" 6 TOWER WINDOW SILL DETAIL 1 1/2" = 1'-0" 9 TOWER WALL BASE DETAIL 1 1/2" = 1'-0" 7 TOWER WINDOW HEAD DETAIL 1 1/2" = 1'-0" 1 FOOTER DETAIL OFFSET 1 1/2" = 1'-0" 12 NORTH WINDOW WOOD SILL DETAIL 1 1/2" = 1'-0" 3 NORTH SERVICE WINDOW EAVE DETAIL GENERAL NOTE FOR ALL WINDOW AND DOOR INSTALLATIONS: · PROVIDE BACKEROD & SEALANT AT ALL WINDOW CONNECTIONS TO DISSIMILAR MATERIALS · PROVIDE SELF ADHERED FLASHING AT ALL WINDOW/DOOR OPENINGS · PROVIDE COPPER THRU/DRIP FLASHING AT ALL WINDOW SILLS AND HEADS · PROVIDE J METAL WEEP SCREED AT BASE OF ALL STUCCO WALLS · PROVIDE WEEP AT BASE OF STONE WALLS 3" = 1'-0" 18 TYP ROOF TO E BLDG DETAIL 3" = 1'-0" 17 ENTRY WALL CAP DETAIL 3" = 1'-0" 15 DETAIL @ TOWER WINDOW SILL TYP 3" = 1'-0" 16 DETAIL@ TOWER WINDOW HEAD TYP 1 1/2" = 1'-0" 13 DETAIL AT TOWER ROOF FASCIA REVISION DATE 6 FOR CONSTRUCTION 06.16.15 7 PR NO 1 03.04.16 16 ASI-01 05.25.16 17 PR NO 2 09.02.16 1 1/2" = 1'-0" 4 EXTERIOR DETAIL @ TOWER WINDOW HEADS 11/16/16