HomeMy WebLinkAboutB15-0208_A602_1479324480.pdfB B1
7' - 6"
AFF
C-4
8' - 3" AFF
C-5
8' - 3"
1X6 IPE WOOD DECKING @ 6" O.C.
EPDM ROOFING ON 5/8" PLYWOOD ON
1/4"/FT SLOPED 2XWOOD SLEEPERS ON
TAPERED RIGID INSULATION
[E] SLIDING DOORS. PROVIDE NEW
SILL FLASHING AND THRESHOLD
11 5/8"
5 3/4"
AFF
C-4
8' - 3"
R-1
3'-6"
1x6 IPE WOOD DECKING
INTERNAL BREAK METAL
GUTTER, SLOPE TO ROOF DRAIN,
PIPE TO STORM SEWER
EPDM ROOFING ON 5/8" PLYWOOD ON
1/4"/FT SLOPED 2XWOOD SLEEPERS
ON TAPERED RIGID INSULATION
2X6 FRAMED WALL W/5/8"
PLYWOOD & ICE AND WATER
SHIELD EA SIDE & OVER TOP
OF WALL [SIM ASSEMBLY 3
SIDES OF DECK]
M-1
CONT WALL CAP FLASHING
W/DRIP EDGE OVER ICE AND
WATER SHIELD
J METAL WEEP SCREED AT BASE OF
STUCCO
CONT FLASHING OVER ICE AND WATER
SHIELD WRAPPING BASE OF GUTTER
KN-2
M-1
ROUTE DRAIN LINE TO WALL AT GRID
LINE 1.5 BETWEEN A4 AND A5
B
LEDGER BOARD RE:STRUCTURAL
VIF
3 3/4"
3/4"
A601
18
VARIES
C-4
R-1
5.5
AFF
C-4
8' - 3"
R-1
EXISTING RETAIL INTERIOR
PROVIDE CONT FLASHING AT [E] BLDG
WALL
PROVIDE CONT ICE AND WATER
SHIELD UP TO [E] BLDG WINDOW
PT-4
3 5/8" METAL FRAMING AND GYP BD
PROJECT
NUMBER:
PROJECT DATE:
SHEET TITLE:
SHEET NUMBER:
A602
143100
COMMISSARY
August 22,
2016
EXTERIOR DETAILS
232 BRIDGE STREET, VAIL, CO 81657
1 1/2" = 1'-0"
1
DECK DETAIL @ EXISTING BUILDING
1 1/2" = 1'-0" 2
DECK WALL DETAIL
1 1/2" = 1'-0"
4
TYP ROOF DETAIL @ E BUILDING
1 1/2" = 1'-0" 5 DETAIL @ SOUTH DINING ROOF
GENERAL NOTE FOR ALL WINDOW AND DOOR INSTALLATIONS:
· PROVIDE BACKEROD & SEALANT AT ALL WINDOW CONNECTIONS TO DISSIMILAR MATERIALS
· PROVIDE SELF ADHERED FLASHING AT ALL WINDOW/DOOR OPENINGS
· PROVIDE COPPER THRU/DRIP FLASHING AT ALL WINDOW SILLS AND HEADS
· PROVIDE J METAL WEEP SCREED AT BASE OF ALL STUCCO WALLS
· PROVIDE WEEP AT BASE OF STONE WALLS
RAILING TO BE CUSTOM WROUGHT IRON SHAPE, GC TO PROVIDE
FULL SCALE MOCK UP 3' WIDE MINIMUM FOR OWNER APPROVAL
PRIOR TO ORDERING MATERIALS
REVISION DATE
6 FOR
CONSTRUCTION
06.16.15
7 PR NO 1 03.04.16
17 PR NO 2 09.02.16
11/16/16