Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B15-0208_A603_1479324480.pdf
B 5.8 A9 W-3 W-8 HM DOOR FRAME W/SINGLE RABBIT 7 3/8" 3/4" 4" 2" 7/8" 6" 1 1/2" 2" 2 1/2" 2 1/2" C14 5.8 A7 7 1/2" 8 3/8" 4 1/4" 3 1/4" HM DOOR FRAME W/SINGLE RABBIT W-3 3 1/2" 4 7/8" 5 1/2" W-8 2 1/8" 3/4" 4" 3/4" 3/4" C13 7 1/2" 5.5 A3 A5 3" DIA COPPER DOWNSPOUT STAINLESS STEEL GRATE LINEAR DRAIN 7 1/4" CLOSED CELL INSULATION C11 C12 7/8" 3/4" 1 1/2" 3/4" 3/4" 3/4" 4" 3/4" 3/4" 7" 2" 3/4" 3/4" 1'-5 7/8" 3 7/8" 1'-3 1/2" 4.7 A3 A2 1'-0" 1'-5 7/8" ? 7 1/4" 3 5/8" 3 5/8" 7/8" 3/4" 4" 3/4" 3/4" C10 C9 7/8" 3/4" 1 1/2" 3/4" 3 7/8" ? W-8 W-3 1'-3 1/2" 7/8" 5 1/2" 7/8" 7" 3/4" 3/4" A2 A1 4.1 7" ? W-8 7/8" 1 1/4" 1/2" 3" 3" ALIGN 3 5/8" MTL FRAMING BLOCKING C8 3/4" 3/4" 4" 3/4" 3/4" 3 1/2" 10 1/2" 7 3/4" 3" 5/8" 2" STUCCO 1.2" R-10 RIGID INSULATION CAULK 3/4" PLYWOOD 1/2" PLYWOOD 6" MTL FRAMING 1.2" R-10 RIGID INSULATION 7/8" CEDAR LINE OF HEAVY TIMBER ABOVE LINE OF HEAVY TIMBER ABOVE LINE OF HEAVY TIMBER ABOVE LINE OF HEAVY TIMBER ABOVE W-3 4" 3.8 A1 8" 11 1/4" 8" 2 5/8" 4 1/4" 4 1/2" CURTAIN AND ROD C17 RIGID INSULATION STUCCO 1/2" 3/4" 7/8" 1/2" 3/4" 1 1/4" 6" 3/4" 5/8" GYP BD ? ? VAPOR BARRIER CAULK 4 1/4" 3 3/4" W-8 W-3 BACKER ROD AND SEALANT ALIGN A1 3.5 8 1/2" 4 1/2" 2 3/4" 4 1/8" ? 3/8" 5 1/2" 1" 1/2" 3/4" 1 1/4" 1/2" 8" C16 3 A2 A1 2.9 8" 6 7/8" 7" 7 3/4" C15 C7 2.5 A3 A5 A2 A4 8" 7" 3 1/2" CLOSED CELL SPRAY INSULATION C5 C6 5 7/8" 7 1/4" 1.5 A5 A4 A6 3 1/2" 1'-1" 8" 5 7/8" 3" 1'-1" 2 1/2" 2 1/2" STAINLESS STEEL GRATE LINEAR DRAIN 3" DIA COPPER DOWNSPOUT W-3 C3 C4 7 1/4" 5 7/8" A6 HM DOOR FRAME W/SINGLE RABBIT 6" 3 1/2" 6" 5 7/8" 1.2 A6 7 1/4" 9 3/8" ? C2 5 7/8" B 1.2 A8 7 1/4" 7 3/8" 7 1/2" C1 PROJECT NUMBER: PROJECT DATE: SHEET TITLE: SHEET NUMBER: A603 143100 COMMISSARY August 22, 2016 EXTERIOR DETAILS 232 BRIDGE STREET, VAIL, CO 81657 3" = 1'-0" 1 PLAN DETAIL GRID 5.8 3" = 1'-0" 5 PLAN DETAIL GRID A7 3" = 1'-0" 11 PLAN DETAIL GRID 5.5 3" = 1'-0" 12 PLAN DETAIL GRID 4.7 3" = 1'-0" 8 PLAN DETAIL GRID 4.1 3" = 1'-0" 9 PLAN DETAIL GRID A1 3" = 1'-0" 10 PLAN DETAIL GRID 3.5 3" = 1'-0" 3 PLAN DETAIL GRID 2.9 3" = 1'-0" 2 PLAN DETAIL GRID 2.5 3" = 1'-0" 13 PLAN DETAIL GRID 1.5 3" = 1'-0" 6 PLAN DETAIL GRID A6 3" = 1'-0" 7 PLAN DETAIL GRID 1.2 3" = 1'-0" 4 PLAN DETAIL GRID A8 GENERAL NOTE FOR ALL WINDOW AND DOOR INSTALLATIONS: · PROVIDE BACKEROD & SEALANT AT ALL WINDOW CONNECTIONS TO DISSIMILAR MATERIALS · PROVIDE SELF ADHERED FLASHING AT ALL WINDOW/DOOR OPENINGS · PROVIDE COPPER THRU/DRIP FLASHING AT ALL WINDOW SILLS AND HEADS · PROVIDE J METAL WEEP SCREED AT BASE OF ALL STUCCO WALLS · PROVIDE WEEP AT BASE OF STONE WALLS REVISION DATE 6 FOR CONSTRUCTION 06.16.15 7 PR NO 1 03.04.16 16 ASI-01 05.25.16 17 PR NO 2 09.02.16 11/16/16