HomeMy WebLinkAboutB14-0277_CCK1 Electrical Load Calc_1407170280.pdf I Native Electric, Inc. PO Box 1807 Eagle, CO 81631 LOAD CALC Submitted to: David Cabin 2450 Chaminiox,Unit K-1, Vail, Colorado 650 square feet @ 3 watts per ft.= 1950 Small appliance X 2 =3000 Dishwasher = 1500 Boiler = 1500 Fridge = 1500 Dryer =5000 Washer = 1500 Range =7000 TOTAL =22,950 First 10 KVA @ 100% = 10,000 Remaining Load @ 40% = 5,180 Total Load @ 15.180 15180/240= 64 AMPS LOAD CALC =64 AMPS NOTE: We will be adding recess lighting with LED lights. Upgrade devices to tamper proof. And install smoke and carbon detectors as needed.