HomeMy WebLinkAboutB14-0426_B14-0426 cut sheets_1413901800.pdf 0 TriangleTube
PRESTIGE Solo
Condensing High Efficiency Gas Boiler
Stainless Steel Fire Tube •
Heat Exchanger
95% AFUE •
Low Pressure Drop •
Proven Performance •
2" to 4" Venting .
Multiple Termination Options •
Low NOx - 2012 SCAGIMD Certified • 111 •.i■
5 Models from 60 to 399 MBH • O
2 Year Control & Blower Warranty • I
Featuring TriMax Control with: t
os,„
• 60 Second Set-Up
r- . Slir
• • Integrated Cascade
• Two Reset Curves/Set
•
Points , pil° -' it
• Control of 4 Circulators
U
1111
M0 aV5 ;
�� TriariIETuGe A
prestige - Leader in Contractor FrieoI Features
TriMax Control
60 Second Set-Up
Choose from 6 standard applications to set up the boiler in 60 seconds or less.
• Finned Tube Baseboard • High Mass Radiant
• Cast Iron Baseboard • Low Mass Radiant
r-- • Radiators • Fancoil
•
! g■ ■ Integrated Cascad'
Joins up to 6 boilers: Master boiler automatically recognizes linked boilers:
Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation.
multiple Lone i ircuiator Control
Manages 2 separate reset curves for high and low temperature zones:
Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW
• zone without external zone control panel.
n —
Intelligent Troubleshooting
Describes lockouts in plain english and suggests solutions: Stores last 8
errors. Records sensor readings for 24 hours.
Next Generation Fire Tube Heat Exchanger
High Water Content - ° . ■
• Provides stable temperature control
• Low sensitivity to water flow 01111111.1.1.
• Reduces short cycling
• Adapts to large or small heating loads !
Ft�q
Unique ueometry in
• Designed for maximum reliability with low thermal stress
• Improved water flow for maximum heat transfer } I 41 I
• 439 Stainless Steel for corrosion resistance
I
• Polypropylene condensate pan and flue resists corrosion �.,,!
Reliable Low Maintenance Design
• Self cleaning design washes away combustion debris • ;•14 tF ry ,
• 10 year history of reliable performance
• High performance burner design
• Low pressure drop allows piping directly to the system
prestige - Leader in Contractor FrienI Features
Prestige Solo 110 Exploded View
Test Ports in both Flue and Air Connections
_ Jro7_
Integrated Circulator&DHW Supply on
Solo 110 Model
Simplifies piping and wiring
.
•
•
•
ti
•
.111
II a
Polypropylene Flue and Condensate Pan
Eliminates corrosion from condensate
Fold Down Control Panel
Permits quick access to boiler internals Simplified Wiring Connections
Wiring connections are well laid out
and clearly marked. Fused high voltage
connections makes trouble shooting easy
The Widest Range of Venting and Termination Options
Venting Terminations
- 2", 3", and 4" diameters depending on model - Traditional PVC/CPVC/PP/SS piping elbows
- PVC,CPVC, SS and Polypropylene materials - Flush-mount PVC for twin pipes
- Flexible Polypropylene for chimney chases - Flush-mount Stainless Steel for twin pipes
- Concentric (399 only) or twin pipe - Single hole Concentric Termination for twin pipes
- Extended vent lengths up to 100 feet - Horizontal Concentric Termination (399 only)
-Common Vent for multiple boilers (399 only) - Horizontal and Vertical Common Vent Terminations (399 only)
pies ige
Performance Specifications
Model Fuel Input AFUE DOE NET Water
Modulation Heating Capacity l=B=R Volume
MBH MBH MBH Gal.
Solo 60 Natural or Propane 16 to 60 95% 54 47 2.5
Solo 110 Natural Gas 30 to 110 95% 99 86 2.5
Solo 110 LP Propane Gas 25 to 97 95% 87 76 2.5
Solo 175 Natural or Propane 50 to 170 95% 154 134 4.6
Solo 250 Natural or Propane 65 to 245 95% 223 194 4.1
Solo 399 Natural or Propane 112 to 399 95.1 %* 379 330 7
Connections / Dimensions / Data "Thermal Efficiency
Model Supply/Return Gas Vent/Air Dimensions Weight
Connections Connection Diamete x W x H Lbs
Solo 60 1" 1/2" 3" 16"x 20"x 35 1/2" 95
Solo 110 1" 1/2" 3" 16"x 20"x 35 1/2" 106
Solo 175 1 1/4" 3/4" 3" 16"x 20"x 35 1/2" 131
Solo 250 1 1/4" 3/4" 3" 16"x 20"x 35 1/2" 142
Solo 399 1 1/2" 1" 4" 20 3/4"x 24 3/4"x 37 1/2" 200
TriMax Control Features Standard Features
1 Large Graphic Interface 1 Stainless Steel FireTube Heat Exchanger
1 60 Second Set-Up I EZ Access Terminal Strips with Individually
1 Customizable Reset Curves with 6 Presets Fused High VoltageTerminals
1 Standard Modbus Interface • Outdoor Reset Sensor
I 2 Space Heating Call Inputs rt Negative Pressure Regulated Gas Valve
0 Controls up to 4 Circulators 0 LP Conversion Kit
I 0-10 VDC Modulation Input (All Models except So1o110)
• Outdoor Reset Cat IV Venting
10 Lockout Screens with Error Description and NPT Piping Connections
Troubleshooting recommendations: rt Integrated Pressure Gauge
Cascade Control for up to 6 Boilers
-Auto-configure linked boilers 0 30 psi Pressure Relief Valve
- Simultaneous space heating & DHW capability i Automatic Air Vent
- Full parallel modulation
- Boiler rotation 1 Fold-down Control Panel for Easy Access
I DHW Priority 1 Condensate Trap
0 Warm Weather Shutdown I 10 Year Non-Prorated Heat Exchanger
I Low Water Cut Off Warranty
0 2 Year Control & Blower Warranty
Triangle Tube reserves the right to make product changes or improvements at any time without notice.
"T",o 1 Triangle Lane Blackwood, NJ 08012 An
ISOtd 9001 Tr i a n S I eTu b e Tel: (856)228 8881- Fax: (856)228 3584
N
E-mail: info@triangletube.com -http://www.triangletube.com Company
2011-48 Prestige Solo Lit.-Revised 1/17/13