Loading...
HomeMy WebLinkAboutB15-0011_Wall Street Electrical COMCheck Report_1425421500.pdf COMcheck Software Version 3.9.4 Interior Lighting and Power Compliance Certificate ...............OR�� 4.. •F 90.1 (2010) Standard i •� f // 01 35837 Section 1: Project Information 3\i. 2/23/15 : •• . • �/ Project Type:Addition ••''�`SS/OrIAL 'C.•••• Project Title Construction Site: Owner/Agent: Designer/Contractor: Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Retail Space(Retail:Sales Area) 262 1.68 440 Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:T1 262(a) 1.4 367(b) Building Lobby(Common Space Types:Lobby-General) 218 0.9 196 Supplemental Allowed Watts(c)= 353 Total Allowed Watts= 1356 (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less. (c) Supplemental watts must be associated with retail merchandise highlighting fixtures.Supplemental watts are not included calculation of lighting complaince percentage. Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail Space(Retail:Sales Area 262 sq.ft.) Track lighting 1:Ti:Track:Wattage based on 24 feet of track 0 0 720 720 LED 1:ED1:LED Downlight:Other: 1 7 13 91 Building Lobby(Common Space Types:Lobby-General 218 sq.ft.) Total Proposed Watts= 811 Interior Lighting PASSES:Design 19%better than code. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consis ent with the building plans,specifications and other calculations submitted with this permit application.The proposed lightint system has •-en designed to meet the 90.1 (2010)Standard requirements in COMcheck Version 3.9.4 and to comply with the mandatory iequir- ents' the/-• ire,ments Checklist. Jeff Mullikin „ 2/23/2015 Name-Title Sign - Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Project Title: Report date: 02/23/15 Data filename:J:\2777.00-Wall Street\Ltg Calcs\277700LC01 -Wild Bills.cck Page 1 of 3 Lighting Designer or Contractor Name Signature Date ,•' O REG *o • • 0 . v' 65837 2/23/15 .� ••••••°S/ONAC* ••,. ••••••... ...... Project Title: Report date: 02/23/15 Data filename:J:\2777.00-Wall Street\Ltg Calcs\277700LC01 -Wild Bills.cck Page 2 of 3 in° ExteriorCOMcheck SoftwareLighting Version 3.9.4 Compliance Certificate ............••• ••••.o•'.O RE c 'T�: . 90.1 (2010) Standard t$ •00„ ' - - 5837 ? - Section 1: Project Information = 2/23/15 z' •• Project Type:Addition sgti ,_•,.-;:\,„\s„-..? •'•• Project Title : '•..;SS/ONp�L • Exterior Lighting Zone: 2(Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts /Unit (B x C) Building Canopy(Entry canopy) 796 ft2 0.25 Yes 199 821 Entry Facade(Illuminated length of facade wall or 35 ft 2.5 No 88 0 surface) Deck Doors(Other door(not main entry)) 90 ft of door width 20 Yes 1800 0 Total Tradable Watts*= 1999 821 Total Allowed Watts= 2087 Total Allowed Supplemental Watts"= 600 *Wattage tradeoffs are only allowed between tradable areas/surfaces. "A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Building Canopy(Entry canopy 796 ft2):Tradable Wattage LED 1:ED1:LED Downlight:Other: 1 20 13 260 LED 2:ED2:LED Aimable Downlight:Other: 1 18 17 306 LED 3:EW1:Wall Sconce:Other: 1 15 17 255 Entry Facade(Illuminated length of facade wall or surface 35 ft):Non-tradable Wattage Deck Doors(Other door(not main entry)90 ft of door width):Tradable Wattage Total Tradable Proposed Watts= 821 Section 4: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The propose. lighting syste/ has been designed to meet the 90.1 (2010) Standard requirements in COMcheck Version 3.9.4 and to comply with th r mandatory r Quire, - s in the Requirements Checklist. i Jeff Mullikin .....A 2/23/2015 mm Name-Title I. e ' , Date Project Title: Report date: 02/23/15 Data filename:J:\2777.00-Wall Street\Ltg Calcs\277700LC01 -Wild Bills.cck Page 3 of 3