HomeMy WebLinkAboutB15-0011_Wall Street Electrical COMCheck Report_1425421500.pdf COMcheck Software Version 3.9.4
Interior Lighting and Power
Compliance Certificate ...............OR�� 4..
•F
90.1 (2010) Standard i •� f //
01 35837
Section 1: Project Information 3\i. 2/23/15 : ••
. • �/
Project Type:Addition ••''�`SS/OrIAL 'C.••••
Project Title
Construction Site: Owner/Agent: Designer/Contractor:
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
Retail Space(Retail:Sales Area) 262 1.68 440
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:T1 262(a) 1.4 367(b)
Building Lobby(Common Space Types:Lobby-General) 218 0.9 196
Supplemental Allowed Watts(c)= 353
Total Allowed Watts= 1356
(a)Area claimed must not exceed the illuminated area permitted for this allowance type.
(b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less.
(c) Supplemental watts must be associated with retail merchandise highlighting fixtures.Supplemental watts are not included
calculation of lighting complaince percentage.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Retail Space(Retail:Sales Area 262 sq.ft.)
Track lighting 1:Ti:Track:Wattage based on 24 feet of track 0 0 720 720
LED 1:ED1:LED Downlight:Other: 1 7 13 91
Building Lobby(Common Space Types:Lobby-General 218 sq.ft.)
Total Proposed Watts= 811
Interior Lighting PASSES:Design 19%better than code.
Section 4: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consis ent with the building plans,specifications and
other calculations submitted with this permit application.The proposed lightint system has •-en designed to meet the 90.1 (2010)Standard
requirements in COMcheck Version 3.9.4 and to comply with the mandatory iequir- ents' the/-• ire,ments Checklist.
Jeff Mullikin „ 2/23/2015
Name-Title Sign - Date
Section 5: Post Construction Compliance Statement
Record Drawings and Operating and Maintenance Manuals:
1. Construction documents with record drawings and operating and maintenance manuals provided to the owner.
Project Title: Report date: 02/23/15
Data filename:J:\2777.00-Wall Street\Ltg Calcs\277700LC01 -Wild Bills.cck Page 1 of 3
Lighting Designer or Contractor Name Signature Date
,•' O REG *o
•
• 0 .
v' 65837
2/23/15 .�
••••••°S/ONAC* ••,.
••••••... ......
Project Title: Report date: 02/23/15
Data filename:J:\2777.00-Wall Street\Ltg Calcs\277700LC01 -Wild Bills.cck Page 2 of 3
in° ExteriorCOMcheck SoftwareLighting Version 3.9.4
Compliance
Certificate ............•••
••••.o•'.O RE c 'T�: .
90.1 (2010) Standard t$ •00„ ' -
- 5837 ? -
Section 1: Project Information = 2/23/15 z' ••
Project Type:Addition sgti ,_•,.-;:\,„\s„-..?
•'••
Project Title : '•..;SS/ONp�L •
Exterior Lighting Zone: 2(Residential mixed use area)
Construction Site: Owner/Agent: Designer/Contractor:
Section 2: Exterior Lighting Area/Surface Power Calculation
A B C D E F
Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed
Watts Wattage Watts Watts
/Unit (B x C)
Building Canopy(Entry canopy) 796 ft2 0.25 Yes 199 821
Entry Facade(Illuminated length of facade wall or 35 ft 2.5 No 88 0
surface)
Deck Doors(Other door(not main entry)) 90 ft of door width 20 Yes 1800 0
Total Tradable Watts*= 1999 821
Total Allowed Watts= 2087
Total Allowed Supplemental Watts"= 600
*Wattage tradeoffs are only allowed between tradable areas/surfaces.
"A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Section 3: Exterior Lighting Fixture Schedule
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Building Canopy(Entry canopy 796 ft2):Tradable Wattage
LED 1:ED1:LED Downlight:Other: 1 20 13 260
LED 2:ED2:LED Aimable Downlight:Other: 1 18 17 306
LED 3:EW1:Wall Sconce:Other: 1 15 17 255
Entry Facade(Illuminated length of facade wall or surface 35 ft):Non-tradable Wattage
Deck Doors(Other door(not main entry)90 ft of door width):Tradable Wattage
Total Tradable Proposed Watts= 821
Section 4: Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,specifications
and other calculations submitted with this permit application.The propose. lighting syste/ has been designed to meet the 90.1 (2010)
Standard requirements in COMcheck Version 3.9.4 and to comply with th r mandatory r Quire, - s in the Requirements Checklist.
i
Jeff Mullikin .....A 2/23/2015
mm
Name-Title I. e ' , Date
Project Title: Report date: 02/23/15