Loading...
HomeMy WebLinkAboutB15-0026_A10.0_1438367880.pdfTELEPHONE/ DATA GFI WP 220 TV FAN 3 D DUPLEX OUTLET SWITCHED OUTLET (ONE SIDE ONLY) GROUND FAULT INTERRUPT OUTLET WATER PROOF GFI OUTLET 220 OUTLET FLOOR MOUNTED DUPLEX TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V 2 CAT V TELEPHONE RECESSED DOWN LIGHT WALL WASHER / DIRECTIONAL DOWN LIGHT SURFACE MOUNTED FIXTURE @ WALL WALL MOUNTED UP LIGHT FIXTURE WALL MOUNTED STEP LIGHT FIXTURE SURFACE MOUNTED FLORESCENT SURFACE MOUNTED ON CEILING LED LIGHTING SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD JUNCTION BOX EXHAUST FAN SWITCH 3-WAY SWITCH / 4-WAY SWITCH DIMMER SWITCH (MAY BE SHOWN AS 3-WAY) J MONOPOINT GENERAL NOTES: 1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES. 2. OUTLETS TO BE AT 14" AND SWITCHES 42" ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT THE ARCHITECT. 3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM 4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE 5.PROVIDE GFI OUTLET UNDER EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS. 6. COORDINATE SWITCHED OUTLETS LOCATIONS AT WALLS AND FLOORS WITH FURNITURE PLANS AND INTERIOR DOCUMENTS 7. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER VFES AND NFPA REQUIREMENTS. CARBON MONOXIDE DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM. 8. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY LOCATION & HEIGHT WITH INTERIOR DESIGNER 9. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH INTERIOR DESIGNER SPECS. 10. SEE MECHANICAL DRAWINGS FOR ALL EXHAUST FAN LOCATIONS 11. PROVIDE POWER AS REQUIRED PER MECHANICAL DRAWINGS AND SPEC. 12. PROVIDE POWER TO HOT TUB VAULT PER EXISTING SPA TO BE RE-USED 13. COORDINATE OUTLET W/ FURNITURE PLANS PER INTERIOR DESIGN DOCUMENTS 14. COORDINATE ALL KITCHEN OUTLET LOCATIONS W/ INTERIOR DESIGN DOCUMENTS 15. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ DOWNSPOUT LOCATIONS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 3/16/2015 9:11:30 AM A10.0 ELECTRICAL SCHEDULE AND NOTES AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET Lighting Fixture Schedule Type Mark Type Manufacturer Model Type Comments Count A Flat Ceiling Recessed Can 90 A2 Flat Ceiling Wall Washer Can 42 A3 Flat Ceiling Mositure Resistant Can 12 A4 Flat Ceiling LED Recessed Can 15 B Sloped Ceiling Adjustable/Wall Washer Recessed Can 88 B2 Sloped Ceiling Moisture Resistant Can 4 C Wall Sconce Uplight Belfer 6215 the Wedge 100 W quartz halogen, Painted to match steel 18 C1 In-floor Uplight- High Efficacy Dreamscape DL-130-INT-LED 3/4 18 D Master Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 6 D1 Guest Master Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 3 D2 Bathroom #2 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 D3 Bathroom #3 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 D4 Bathroom #4 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 3 D5 Bathroom #5 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 D6 Main Level Powder Room Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 D7 Lower Level Powder Room Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 D8 Exterior Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2 E Wall Mounted Sconce Hevi Lite HL-374-BZ, MOUNTED @ 6'-0" ABOVE FINISHED FLOOR Par-20 Bronze Powder Coat Finish (BZ) 2 F Surface Mounted Florescent Above Door- High Efficacy Mounted above door header with motion sensor 3 G Compact Florescent- High Efficacy Surface Mounted (2 lamps per fixture) or LED Recessed Can 9 H 1x4 Florescent- High Efficacy Garage/Mechanical/ Storage (2 32 W florescent lamps per fixture) 13 J J-Box Ceiling Fan Rated 7 L LED Rope Strip Lighting- High Efficacy LED Linear Lighting Strip , 18 LED lamps per 1' 4 L1 LED Rope Strip Lighting- High Efficacy Mounted above motorized window shade valence 1 M Monopoint Ceiling Mounted Hevi Lite HL-384-BZ Integral Low Voltage Transformer, 50W MR-15 Bi-Pin Haloge, Bronze 12 M1 Monopoint Column Mounted Hevi Lite HL-384-BZ Integral Low Voltage Transformer, 50W MR-15 Bi-Pin Haloge, Bronze 2 P2 Surface Mounted Pendant- Kitchen Island 3 P3 Surface Mounted Pendant- Main Level Ber 2 Q Step Light- High Efficacy Dreamscape DL-126-LED Ancient Bronze Finish 42 Grand total: 411 1/4" = 1'-0" ELECTRICAL LEGEND 1/4" = 1'-0" GENERAL NOTES - REFLECTED CEILING PLAN No. Revision Date Revision Description REVISED NOTE 07/31/15