HomeMy WebLinkAboutB15-0026_A10.0_1438367880.pdfTELEPHONE/
DATA
GFI
WP
220
TV
FAN
3
D
DUPLEX OUTLET
SWITCHED OUTLET (ONE SIDE ONLY)
GROUND FAULT INTERRUPT
OUTLET
WATER PROOF GFI OUTLET
220 OUTLET
FLOOR MOUNTED DUPLEX
TELEVISION / PROVIDE 2
RG-6 AND 2 CAT-V
2 CAT V TELEPHONE
RECESSED DOWN LIGHT
WALL WASHER /
DIRECTIONAL DOWN LIGHT
SURFACE MOUNTED FIXTURE @ WALL
WALL MOUNTED UP LIGHT FIXTURE
WALL MOUNTED STEP LIGHT FIXTURE
SURFACE MOUNTED FLORESCENT
SURFACE MOUNTED ON CEILING
LED LIGHTING
SURFACE MOUNTED FLORESCENT
MOUNTED ABOVE DOOR HEAD
JUNCTION BOX
EXHAUST FAN
SWITCH
3-WAY SWITCH / 4-WAY SWITCH
DIMMER SWITCH (MAY BE
SHOWN AS 3-WAY)
J
MONOPOINT
GENERAL NOTES:
1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT
SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
2. OUTLETS TO BE AT 14" AND SWITCHES 42" ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE,
CONSULT THE ARCHITECT.
3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM
4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS
POSSIBLE
5.PROVIDE GFI OUTLET UNDER EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
6. COORDINATE SWITCHED OUTLETS LOCATIONS AT WALLS AND FLOORS WITH FURNITURE PLANS AND INTERIOR DOCUMENTS
7. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER VFES AND NFPA REQUIREMENTS. CARBON MONOXIDE DETECTORS WILL BE
CONNECTED TO THE ALARM SYSTEM.
8. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY LOCATION & HEIGHT WITH INTERIOR DESIGNER
9. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH INTERIOR DESIGNER SPECS.
10. SEE MECHANICAL DRAWINGS FOR ALL EXHAUST FAN LOCATIONS
11. PROVIDE POWER AS REQUIRED PER MECHANICAL DRAWINGS AND SPEC.
12. PROVIDE POWER TO HOT TUB VAULT PER EXISTING SPA TO BE RE-USED
13. COORDINATE OUTLET W/ FURNITURE PLANS PER INTERIOR DESIGN DOCUMENTS
14. COORDINATE ALL KITCHEN OUTLET LOCATIONS W/ INTERIOR DESIGN DOCUMENTS
15. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ DOWNSPOUT LOCATIONS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
3/16/2015 9:11:30 AM
A10.0
ELECTRICAL
SCHEDULE
AND NOTES
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
Lighting Fixture Schedule
Type
Mark Type Manufacturer Model Type Comments Count
A Flat Ceiling Recessed Can 90
A2 Flat Ceiling Wall Washer Can 42
A3 Flat Ceiling Mositure Resistant Can 12
A4 Flat Ceiling LED Recessed Can 15
B Sloped Ceiling Adjustable/Wall Washer Recessed
Can
88
B2 Sloped Ceiling Moisture Resistant Can 4
C Wall Sconce Uplight Belfer 6215 the Wedge 100 W quartz halogen, Painted to match steel 18
C1 In-floor Uplight- High Efficacy Dreamscape DL-130-INT-LED 3/4 18
D Master Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 6
D1 Guest Master Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 3
D2 Bathroom #2 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
D3 Bathroom #3 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
D4 Bathroom #4 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 3
D5 Bathroom #5 Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
D6 Main Level Powder Room Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
D7 Lower Level Powder Room Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
D8 Exterior Bathroom Sconce Wall Mounted Sconce - center of box @ 5'-0" AFF 2
E Wall Mounted Sconce Hevi Lite HL-374-BZ, MOUNTED @ 6'-0"
ABOVE FINISHED FLOOR
Par-20 Bronze Powder Coat Finish (BZ) 2
F Surface Mounted Florescent Above Door- High
Efficacy
Mounted above door header with motion sensor 3
G Compact Florescent- High Efficacy Surface Mounted (2 lamps per fixture) or LED Recessed Can 9
H 1x4 Florescent- High Efficacy Garage/Mechanical/ Storage (2 32 W florescent lamps per fixture) 13
J J-Box Ceiling Fan Rated 7
L LED Rope Strip Lighting- High Efficacy LED Linear Lighting Strip , 18 LED lamps per 1' 4
L1 LED Rope Strip Lighting- High Efficacy Mounted above motorized window shade valence 1
M Monopoint Ceiling Mounted Hevi Lite HL-384-BZ Integral Low Voltage Transformer, 50W MR-15 Bi-Pin Haloge, Bronze 12
M1 Monopoint Column Mounted Hevi Lite HL-384-BZ Integral Low Voltage Transformer, 50W MR-15 Bi-Pin Haloge, Bronze 2
P2 Surface Mounted Pendant- Kitchen Island 3
P3 Surface Mounted Pendant- Main Level Ber 2
Q Step Light- High Efficacy Dreamscape DL-126-LED Ancient Bronze Finish 42
Grand total: 411
1/4" = 1'-0"
ELECTRICAL LEGEND
1/4" = 1'-0"
GENERAL NOTES - REFLECTED CEILING
PLAN
No. Revision Date
Revision
Description
REVISED NOTE
07/31/15