HomeMy WebLinkAboutB15-0026_A2.1_1438367880.pdf2280 SF
LOWER LEVEL
HABITABLE AREA
8' - 11 1/4" 12' - 6" 23' - 5 1/2"
12' - 6 1/2" 19' - 0" 8' - 8"
2' - 6"
20' - 0"
A
B C
D
E
F
19' - 0"
G
H
I
J
K
L
M
N
25' - 6 3/4"
19' - 6"
P
O
47' - 5 1/2"
11' - 2 7/8"
6' - 5"
12' - 2 7/8"
8' - 9 1/2"
36' - 0"
24' - 6"
1' - 0"
12' - 6 1/2" 2' - 6"
23' - 5 1/2"
12' - 6"
19' - 6"
20' - 0"
2267 SF
MAIN LEVEL
HABITABLE AREA
882 SF
GARAGE AREA
4' - 6"
46' - 9 1/2" 6' - 5" 8' - 9 1/2"
8' - 11 1/4" 25' - 6 3/4"
5' - 2 1/2" 8' - 1" 5' - 8 1/2"
11' - 2 7/8"
2472 SF
UPPER LEVEL
HABITABLE AREA
422 SF
DOUBLE HEIGHT AREA
93 SF
DOUBLE HEIGHT AREA
23' - 5 1/2"
12' - 6 1/2" 2' - 6"
28' - 0" 8' - 0"
2' - 6"
22' - 0" 36' - 0" 47' - 3" 14' - 9"
1' - 0"
19' - 6"
22' - 6 1/8"
12' - 6" 9' - 11 1/4"
25' - 6 3/4"
5' - 2 1/2" 8' - 1" 3' - 2 3/8"
3149 SF
SITE COVERAGE
8' - 11 1/4"
12' - 6"
23' - 5 1/2"
12' - 6 1/2" 2' - 6"
8' - 0"
1' - 0"
36' - 0" 24' - 6"
36' - 0" 62' - 0"
1' - 0"
19' - 6"
20' - 0"
51 SF
AREA OF ROOF
BEYOND 4'
20' - 0" 25' - 6 3/4" 19' - 0" 8' - 11 1/4" 12' - 6" 23' - 5 1/2" 2' - 6" 12' - 6 1/2" 8' - 8" 19' - 0"
47' - 5 1/2" 11' - 2 7/8" 6' - 5" 12' - 2 7/8" 8' - 9 1/2" 19' - 6"
A B C D E F
G H I J K L M N
LOWER LEVEL T.O. SLAB @
8294' - 7 3/4"
B.O. STRUCTURE @
8303' - 9"
9' - 1 1/4"
LOWER LEVEL T.O. SLAB @
8294' - 7 3/4"
B.O. STRUCTURE @
8303' - 9"
9' - 1 1/4" O P
TOTAL WALL AREA = 2,347 SF
COVERED WALL AREA = 1,460 SF
1,460 SF / 2,347 SF = .62 X 100= 62% OF THE LOWER LEVEL
EXTERIOR WALL IS COVERED. THEREFOR 38% OF THE LOWER
LEVEL AREA COUNTS TOWARDS GRFA.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/8" = 1'-0"
2/3/2015 3:32:05 PM
A2.1
AREA
CALCS
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/8" = 1'-0"
1
LOWER LEVEL AREA PLAN
1/8" = 1'-0"
2 MAIN LEVEL AREA PLAN
1/8" = 1'-0"
3
UPPER LEVEL AREA PLAN
1/8" = 1'-0"
4
SITE COVERAGE AREA PLAN
Fleeger Residence
2950 Booth Creek Drive, Vail Village Filing 11, Block 3, Lot 2
Zone District: Two-Family Primary/Secondary Residential ( PS )
Lot is .3679 acres, equal to 16,024 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,900 SF
.13 SF per 1 SF of site area > 10,000 SF of site area 1,024 x 0.13 equals 133 SF
_______________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,633 SF
Allowable site coverage is 20% of lot 3,205 SF
Square Footage Summary Habitable SF GRFA SF
Lower Level 2,280 SF 866 SF *1
Main Level 2,267 SF 2,267 SF
Upper Level 2,472 SF 2,472 SF
Double Height Area 515 SF
____________________________________________________________________
Total 7,019 SF 5,984 SF
Provided SF Allowed SF
Main Unit Garage 882 SF 900.0 SF
Site Coverage 3,200 SF 3,205 SF
GRFA 5,984 SF 6,633 SF
*1 38% OF THE LOWER LEVEL WALL IS ABOVE EXISTING OR FINISHED GRADE WHICHEVER WAS MORE RESTRICTIVE,
THEREFORE 38% OF THE LOWER LEVEL SF IS COUNTED AS GRFA (LOWER LEVEL HABITABLE 2,280 SF * .38 = 866 SF)
Site Coverage
Allowable site coverage is 20% of lot which equals 3,205 SF. 3,200 SF is provided.
1/8" = 1'-0"
5
LOWER LEVEL BELOW GRADE AREA
CALC
No. Revision Date
Revision
Description
07/31/15