Loading...
HomeMy WebLinkAboutB15-0026_A3.4_1438367880.pdfN 8 7 °3 0 '4 1 0 7 . 2 5 ' S55°36'40"W 82.50' 1 .0 ' 1 .0 ' 0 .8 ' 0 .8 ' 0 ' 1 .0 ' 1 .5 ' 1 .2 ' 0.4 ' 5 ' C S W V A4.1 A4.1 1 2 A4.2 1 A4.2 2 E 8298 E 8299 2" / 12" CURVED ROOF CURVED ROOF CURVED ROOF 1 A5.1 1 3 4 5 6 7 8 9 10 2 A B C D E F G H I J 8' - 0" 28' - 0" 8' - 0" 2' - 6" 12' - 6" 16' - 0" 3' - 0" 5' - 3" 14' - 9" 4' - 6" 1' - 0" 16' - 6" 1' - 6" 1' - 0"6" 11' - 3 1/2" 14' - 3 1/4" 8' - 11 1/4" 3' - 0" 4' - 1 3/8" 4' - 0" 1' - 4" 9 7/8" 2' - 0 1/8" 6 5/8" 2' - 0 1/8" 3 1/8" 3 1/8" 3 1/8" 11 15/16" 2 A5.2 11 7/8" 1' - 6 1/8" 4' - 0" 4' - 6" 4' - 0" DOWNSPOUT DOWNSPOUT TRANSFER GUTTER DOWNSPOUT 4' - 0" 4' - 0" 4' - 7" 2' - 1" DOWNSPOUT UNDER EAVE DOWNSPOUT *1 O U T L IN E O F E X IS T IN G ST R U C T U R E B E IN G R E M O VE D LIN E O F E X IS T IN G D E C K T O B E R E M O V E D O U T LIN E O F E X IS T IN G S TR U C T U R E B E IN G R EM O V E D T.O. STRUCTURE @ 8326' - 6 1/16" T.O. STRUCTURE @ 8333' - 1 5/16" T.O. CHIMNEY CAP @ 8340' - 9" T.O. STRUCTURE @ 8331' - 5 15/16" GAS METER LOCATION BELOW ELECTRIC METER LOCATION BELOW 4' - 0" T.O. STRUCTURE @ 8325' - 5 7/8" T.O. STRUCTURE @ 8324' - 8 7/8" 2 A5.1 1 A5.3 2 A5.3 4 A5.3 4 A5.2 5 A5.2 3 A5.3 1 A5.2 3 A5.2 2 A5.4 1 A5.4 BOILER FLUE LOCATIONS SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. 4' - 0" SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. SNOW FENCE TYP. 6 A6.4 4 A6.3 4 A6.3 4 A6.3 4 A6.3 5 A6.3 2 A6.4 5 A6.4 5 A6.3 6 A6.3 1 A6.4 1 A6.4 6 A6.3 8 A6.4 8 A6.4 10 A6.4 6 A6.3 6 A6.3 5 A6.3 6 A6.3 6 A6.3 3 A5.4 2" / 12" 1 A6.4 1' - 9 1/8" 8 5/8" 8 5/8" T.O. STRUCTURE @ 8332' - 0 1/2" 3 A5.1 LOWER LEVEL FINISHED FLOOR @ 8294' - 8 1/2" MAIN LEVEL FINISHED FLOOR @ 8305' - 2" UPPER LEVEL FINISHED FLOOR @ 8316' - 2 1/2" EXISTING GRADE @ 8299' - 2 3/4" FINISHED GRADE @ 8305' - 0" GENERAL NOTES: LOT SIZE IS .3679 ACRES, EQUAL TO 16,024 SF 1.) ALL ROOF HEIGHTS ARE TO THE TOP OF SHEATHING ON ROOF PLAN SITE PLAN. 2.) PROVIDE ENGINEERED SNOW GUARD FENCE SYSTEM PER ROOF SLOPE TYPE AND SNOW LOAD. SUBMIT FOR APPROVAL. PROVIDE DESIGN BUILD ENGINEERED SNOW FENCE AND SNOW GUARD SYSTEMS @ ALL ROOF AREAS. SEE SPEC FOR MORE INFORMATION. 3.) SEE ELEVATIONS FOR J-BOX LOCATIONS FOR HEAT TAPE FOR GUTTER AND FUTURE HEAT TAPE. PROVIDE HEAT TAPE FOR ALL DOWNSPOUTS, GUTTERS, UNDERGROUND HARDPIPE TO DAYLIGHT, AND FUTURE 3' HIGH SECTION OF HEAT TAPE AT ROOF EAVE ABOVE GUTTER. 4.) ROOF HEIGHT CALCULATIONS (ALSO SHOWN ON SITE PLAN): MEASURED TO TOP OF SHEATHING ON TOP OF STRUCTURAL ROOF TO FINISHED OR EXISTING GRADE DIRECTLY BELOW (WHICHEVER IS MORE RESTRICTIVE). DOES NOT INCLUDE 5" INSULATION PANEL OR APPROX. 1" OF ROOFING. *1- ROOF RIDGE HEIGHT @ SHEATHING = 8332' -0 1/2" EXISTING GRADE BELOW RIDGE = 8299' - 2 3/4" ROOF HEIGHT = 32' - 9 3/4" 5.) PROVIDE DESIGN BUILD ENGINEERED SNOW FENCE AND SNOW GUARD SYSTEMS @ ALL ROOF AREAS. SEE SPEC FOR MORE INFORMATION. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 2/3/2015 3:33:35 PM A3.4 ROOF PLAN AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET 1/4" = 1'-0" 1 ROOF PLAN 0' 2' 4' 8' 16' No. Revision Date Revision Description 07/31/15