HomeMy WebLinkAboutB15-0026_A3.4_1438367880.pdfN 8 7 °3 0 '4
1
0
7
.
2
5
'
S55°36'40"W 82.50'
1 .0 '
1 .0 '
0 .8 '
0 .8 '
0 '
1 .0 '
1 .5 '
1 .2 '
0.4 '
5 '
C S
W V
A4.1 A4.1
1 2
A4.2
1
A4.2
2
E 8298
E 8299
2" / 12"
CURVED ROOF
CURVED ROOF
CURVED ROOF
1
A5.1
1 3 4 5 6 7 8 9 10
2
A
B
C
D
E
F
G
H
I
J
8' - 0" 28' - 0" 8' - 0" 2' - 6" 12' - 6" 16' - 0" 3' - 0" 5' - 3" 14' - 9"
4' - 6" 1' - 0" 16' - 6" 1' - 6" 1' - 0"6" 11' - 3 1/2" 14' - 3 1/4" 8' - 11 1/4"
3' - 0"
4' - 1 3/8" 4' - 0"
1' - 4"
9 7/8"
2' - 0 1/8"
6 5/8"
2' - 0 1/8"
3 1/8"
3 1/8"
3 1/8"
11 15/16"
2
A5.2
11 7/8"
1' - 6 1/8"
4' - 0" 4' - 6"
4' - 0"
DOWNSPOUT
DOWNSPOUT
TRANSFER GUTTER
DOWNSPOUT
4' - 0"
4' - 0"
4' - 7"
2' - 1"
DOWNSPOUT UNDER EAVE
DOWNSPOUT
*1
O U T L IN E O F E X IS T IN G ST R U C T U R E B E IN G R E M O VE D
LIN E O F E X IS T IN G D E C K T O B E R E M O V E D
O U T LIN E O F E X IS T IN G
S TR U C T U R E B E IN G R EM O V E D
T.O. STRUCTURE @ 8326' - 6 1/16"
T.O. STRUCTURE @ 8333' - 1 5/16"
T.O. CHIMNEY CAP @ 8340' - 9"
T.O. STRUCTURE @ 8331' - 5 15/16"
GAS METER
LOCATION
BELOW
ELECTRIC METER
LOCATION BELOW
4' - 0"
T.O. STRUCTURE @ 8325' - 5 7/8"
T.O. STRUCTURE @ 8324' - 8 7/8"
2
A5.1
1
A5.3
2
A5.3
4
A5.3
4
A5.2
5
A5.2
3
A5.3
1
A5.2
3
A5.2
2
A5.4
1
A5.4
BOILER FLUE
LOCATIONS
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP.
4' - 0"
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP.
SNOW FENCE TYP. SNOW FENCE TYP.
6
A6.4
4
A6.3
4
A6.3
4
A6.3
4
A6.3
5
A6.3
2
A6.4
5
A6.4
5
A6.3
6
A6.3
1
A6.4
1
A6.4
6
A6.3
8
A6.4
8
A6.4
10
A6.4
6
A6.3
6
A6.3
5
A6.3
6
A6.3
6
A6.3
3
A5.4
2" / 12"
1
A6.4
1' - 9 1/8"
8 5/8" 8 5/8"
T.O. STRUCTURE @ 8332' - 0 1/2"
3
A5.1
LOWER LEVEL FINISHED FLOOR @ 8294' - 8 1/2"
MAIN LEVEL FINISHED FLOOR @ 8305' - 2"
UPPER LEVEL FINISHED FLOOR @ 8316' - 2 1/2"
EXISTING GRADE @ 8299' - 2 3/4"
FINISHED GRADE @ 8305' - 0"
GENERAL NOTES:
LOT SIZE IS .3679 ACRES, EQUAL TO 16,024 SF
1.) ALL ROOF HEIGHTS ARE TO THE TOP OF SHEATHING ON ROOF PLAN SITE PLAN.
2.) PROVIDE ENGINEERED SNOW GUARD FENCE SYSTEM PER ROOF SLOPE TYPE AND SNOW LOAD.
SUBMIT FOR APPROVAL. PROVIDE DESIGN BUILD ENGINEERED SNOW FENCE AND SNOW GUARD
SYSTEMS @ ALL ROOF AREAS. SEE SPEC FOR MORE INFORMATION.
3.) SEE ELEVATIONS FOR J-BOX LOCATIONS FOR HEAT TAPE FOR GUTTER AND FUTURE HEAT TAPE.
PROVIDE HEAT TAPE FOR ALL DOWNSPOUTS, GUTTERS, UNDERGROUND HARDPIPE TO DAYLIGHT, AND
FUTURE 3' HIGH SECTION OF HEAT TAPE AT ROOF EAVE ABOVE GUTTER.
4.) ROOF HEIGHT CALCULATIONS (ALSO SHOWN ON SITE PLAN):
MEASURED TO TOP OF SHEATHING ON TOP OF STRUCTURAL ROOF TO FINISHED OR EXISTING GRADE
DIRECTLY BELOW (WHICHEVER IS MORE RESTRICTIVE). DOES NOT INCLUDE 5" INSULATION PANEL OR
APPROX. 1" OF ROOFING.
*1- ROOF RIDGE HEIGHT @ SHEATHING = 8332' -0 1/2"
EXISTING GRADE BELOW RIDGE = 8299' - 2 3/4"
ROOF HEIGHT = 32' - 9 3/4"
5.) PROVIDE DESIGN BUILD ENGINEERED SNOW FENCE AND SNOW GUARD SYSTEMS @ ALL ROOF AREAS.
SEE SPEC FOR MORE INFORMATION.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/3/2015 3:33:35 PM
A3.4
ROOF PLAN
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/4" = 1'-0"
1
ROOF PLAN
0' 2' 4' 8' 16'
No. Revision Date
Revision
Description
07/31/15