Loading...
HomeMy WebLinkAboutB15-0026_A6.2_1438367880.pdfT.O. PLYWOOD RE: PLANS INTERIOR INTERIOR GARAGE GRID LINE 1' - 0" 2 1/4" 2' - 0" 2' - 0" RE: STRUCT. SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS SEE 3/A6.1 FOR TYP. GARAGE SLAB AND INT. WALL ASSEMBLY SLOPE 5/8" TYPE X GWB @ GARAGE T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE STRUCTURAL SLAB RE: STRUCT. 1' - 3" 1 1/2" 3" 2 1/4" 2' - 0" 2' - 0" RE: STRUCT. SLOPE PER PLANS 4" 3" 8" SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS 3/16" LIFT AND SLIDE DOOR W.P. MEMBRANE CONT. UNDER DOOR SILL TURNS UP 1" VERTICAL OVER METAL FLASHING @ BACK EDGE OF DOOR SILL CONTINUES 3' OUT OVER CONC. SLAB @ PATIO METAL FLASHING UP CONC. WALL, UNDER DOOR SILL AND TURNS UP 1" VERTICAL @ BACK EDGE OF DOOR SILL SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY SEE 1/A6.1 FOR TYP. PATIO ASSEMBLY 6 3/4" T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE 1' - 3" 1 1/2" 3 3/4" 2 1/4" 2' - 0" 2' - 0" RE: STRUCT. SLOPE PER PLANS 4" 3" 8" T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS STRUCT. SLAB RE: STRUCT. 1" STEP SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY METAL FLASHING UP CONC. WALL, UNDER DOOR SILL AND TURNS UP 1" VERTICAL @ BACK EDGE OF DOOR SILL SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY NOTE: GLIDING DOOR IS USED AT SIM. INTERIOR EXTERIOR TYP. 6" STONE VENEER WALL ASSEMBLY SEE 4/A6.1 GRID LINE WOOD SIDING WALL ASSEMBLY SEE 2/A6.5 3D DRAINAGE MEDIUM AND AIR INFILTRATION BARRIER LAPS OVER FLASHING ABOVE STONE FLASHING EXTENDS UP BEHIND AIR INFILTRATION BARRIER MIN. 4", AND EXTENDS OUT OVER STONE OUT MIN. 3" CUT STONE TOP SLOPED MIN 10% INTERIOR 2X6 FRAMING WITH R-20 BLOWN IN CELLULOSE INSULATION (1) LAYER 5/8" TYPE X GWB INTERIOR (1) LAYER 5/8" TYPE X GWB INSTALL PER UL 305 FOR 16" SPACING UL U314 FOR 24" SPACING APPROX. 5 1/2" INTERIOR EXTERIOR TYPICAL COPPER PANEL SIDING ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY NOTE: DO NOT LET COPPER TOUCH STONE VENEER TEMPORARY 1X4 TO BE REMOVED AFTER STONE VENEER INSTALLATION BEFORE COPPER PANEL SIDING INSTALLATION IN-FILL CORNER UP TO TEMPORARY 1X4 TO CREATE STRAIGHT EDGE FOR COPPER PANEL SIDING INSTALLATION MIN. 1/4" SEALANT JOINT BTW COPPER SIDING AND GROUT USE SANDED CAULK TO MATCH MORTAR INTERIOR EXTERIOR TYPICAL COPPER PANEL SIDING ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY TEMPORARY 1X4 TO BE REMOVED AFTER STONE VENEER INSTALLATION BEFORE COPPER PANEL SIDING INSTALLATION IN-FILL UP TO TEMPORARY 1X4 W/ GROUT TO CREATE STRAIGHT EDGE FOR COPPER PANEL SIDING INSTALLATION 1/4" SEALANT JOINT BTW COPPER SIDING AND GROUT *SIM NOTE INDICATES STONE TO WOOD SIDING TRANSITION Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 2/3/2015 3:36:28 PM A6.2 DETAILS AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ GARAGE AND LOWER LEVEL 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ LIFT AND SLIDE DOOR THRESHOLD 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ DOOR THRESHOLD @ FAMILY ROOM 1 1/2" = 1'-0" 4 STONE TO WOOD SIDING TRANSITION 1 1/2" = 1'-0" 5 WALL ASSEMBLY @ 1-HR FIRE RATED WALL 3" = 1'-0" 6 STONE VENEER AND COPPER SIDING CORNER TRANSITION 3" = 1'-0" 7 STONE VENEER AND COPPER SIDING TRANSITION No. Revision Date Revision Description 07/31/15