HomeMy WebLinkAboutB15-0026_A6.2_1438367880.pdfT.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
GARAGE
GRID
LINE
1' - 0"
2 1/4"
2' - 0" 2' - 0"
RE: STRUCT.
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SEE 3/A6.1 FOR TYP.
GARAGE SLAB AND INT.
WALL ASSEMBLY
SLOPE
5/8" TYPE X GWB @ GARAGE
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
STRUCTURAL SLAB
RE: STRUCT.
1' - 3"
1 1/2"
3"
2 1/4"
2' - 0" 2' - 0" RE: STRUCT.
SLOPE PER PLANS
4" 3" 8"
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
3/16"
LIFT AND SLIDE DOOR
W.P. MEMBRANE CONT. UNDER DOOR SILL
TURNS UP 1" VERTICAL OVER METAL
FLASHING @ BACK EDGE OF DOOR SILL
CONTINUES 3' OUT OVER CONC. SLAB @
PATIO
METAL FLASHING UP CONC. WALL, UNDER
DOOR SILL AND TURNS UP 1" VERTICAL @
BACK EDGE OF DOOR SILL
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SEE 1/A6.1 FOR TYP. PATIO
ASSEMBLY
6 3/4"
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
1' - 3" 1 1/2"
3 3/4"
2 1/4"
2' - 0" 2' - 0"
RE: STRUCT.
SLOPE PER PLANS
4" 3" 8"
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
STRUCT. SLAB RE: STRUCT. 1" STEP
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
METAL FLASHING UP CONC. WALL, UNDER
DOOR SILL AND TURNS UP 1" VERTICAL @
BACK EDGE OF DOOR SILL
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
NOTE: GLIDING DOOR IS USED AT SIM.
INTERIOR
EXTERIOR
TYP. 6" STONE VENEER WALL
ASSEMBLY SEE 4/A6.1
GRID
LINE
WOOD SIDING WALL ASSEMBLY SEE
2/A6.5
3D DRAINAGE MEDIUM AND AIR
INFILTRATION BARRIER LAPS OVER
FLASHING ABOVE STONE
FLASHING EXTENDS UP BEHIND AIR
INFILTRATION BARRIER MIN. 4", AND EXTENDS
OUT OVER STONE OUT MIN. 3"
CUT STONE TOP SLOPED MIN 10%
INTERIOR
2X6 FRAMING WITH R-20 BLOWN IN
CELLULOSE INSULATION
(1) LAYER 5/8" TYPE X GWB
INTERIOR
(1) LAYER 5/8" TYPE X GWB
INSTALL PER UL 305 FOR 16"
SPACING UL U314 FOR 24" SPACING
APPROX. 5 1/2"
INTERIOR
EXTERIOR
TYPICAL COPPER PANEL SIDING ASSEMBLY
TYPICAL STONE VENEER WALL ASSEMBLY
NOTE: DO NOT LET COPPER TOUCH STONE
VENEER
TEMPORARY 1X4 TO BE REMOVED AFTER STONE
VENEER INSTALLATION BEFORE COPPER PANEL
SIDING INSTALLATION
IN-FILL CORNER UP TO TEMPORARY 1X4 TO
CREATE STRAIGHT EDGE FOR COPPER PANEL
SIDING INSTALLATION
MIN. 1/4" SEALANT JOINT BTW COPPER SIDING AND GROUT
USE SANDED CAULK TO MATCH MORTAR
INTERIOR
EXTERIOR
TYPICAL COPPER PANEL SIDING ASSEMBLY
TYPICAL STONE VENEER WALL ASSEMBLY
TEMPORARY 1X4 TO BE REMOVED AFTER STONE
VENEER INSTALLATION BEFORE COPPER PANEL
SIDING INSTALLATION
IN-FILL UP TO TEMPORARY 1X4 W/ GROUT TO
CREATE STRAIGHT EDGE FOR COPPER PANEL
SIDING INSTALLATION
1/4" SEALANT JOINT BTW COPPER SIDING AND
GROUT
*SIM NOTE INDICATES STONE TO
WOOD SIDING TRANSITION
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
2/3/2015 3:36:28 PM
A6.2
DETAILS
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1 1/2" = 1'-0"
1
FOUNDATION DETAIL @ GARAGE AND
LOWER LEVEL
1 1/2" = 1'-0"
2
FOUNDATION DETAIL @ LIFT AND SLIDE
DOOR THRESHOLD
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ DOOR
THRESHOLD @ FAMILY ROOM
1 1/2" = 1'-0"
4
STONE TO WOOD SIDING TRANSITION
1 1/2" = 1'-0"
5
WALL ASSEMBLY @ 1-HR FIRE RATED
WALL
3" = 1'-0"
6
STONE VENEER AND COPPER SIDING
CORNER TRANSITION
3" = 1'-0"
7
STONE VENEER AND COPPER SIDING
TRANSITION
No. Revision Date
Revision
Description
07/31/15