HomeMy WebLinkAboutB15-0026_A6.3_1438367880.pdfT.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR EXTERIOR
GRID
LINE
1' - 1"
2' - 0" 2' - 0"
RE: STRUCT.
SEE 1/A6.1 FOR
TYPICAL W.P.
FOUNDATION
ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
9"
P.T. 2X PLATE
SEE 4/A6.1 FOR TYP. STONE
VENEER WALL ASSEMBLY
MIRA DRAIN DRAINAGE MEDIUM OVER
4" RIGID INSULATION MIN. R-20. MIRA
DRAIN IS CONT. @ HORIZONTAL JOGS
TO ALLOW WALL TO DRAIN TO
FOUNDATION PERIMETER DRAIN OVER
GRAVEL
RE: SPEC
BITHUTHANE ON TOP OF P.T. PLYWOOD
EXTENDS MIN. 18" ABOVE FINISHED GRADE
AND 12" BELOW LOWEST HORIZONTAL JOG
IN CONC. WALL
LINE OF FINISHED FLOOR BEYOND
3" 1 1/2" 6" MIN.
11 1/2" 1 1/2"
1' - 0 3/4"
ANGLE SUPPORT RE: STRUCT.
T.O. CONC @ 8304' - 3 3/4"
RE: PLANS
T.O. CONC. LEDGE @ 8303' - 3"
RE: PLANS
5"
1/2" 3 1/2"
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR EXTERIOR
GRID
LINE
1' - 3"
1 1/2"
2 1/4"
2' - 0" 2' - 0"
2' - 5"
7" 8"
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS 6" MIN.
6" MIN. SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SEE 4/A6.1 FOR TYP. STONE
VENEER WALL ASSEMBLY
SLOPE
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR EXTERIOR
GRID
LINE
1 1/2"
2 1/4"
2' - 0" 2' - 0"
4" 3" 8"
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SLOPE PER PLANS
SEE 1/A6.1 FOR TYP. PATIO
ASSEMBLY
TRIM BRD. BEYOND
WINDOW SET IN A BED OF
SEALANT
STONE VENEER BEYOND
TRIM @ WINDOW
WD. JAMB BEYOND
CUT NAILING FLANGE @
WINDOW SILL TO ALLOW
FLASHING UNDER SILL
3 1/8"
5/8" PLYWD. OVER FRAMING
P.T. 2X6 RIPPED TO FIT FOR
SUPPORT WINDOW
FLASHING TO MATCH ROOFING MATERIAL RE: SPEC
AEP SPAN STANDING SEAM ROOF
RE: SPEC
2X8 WOOD FASCIA W/ KERF CUTS
HIGH TEMP. VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP) FOR
FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
2X10 WOOD SUB-FASCIA W/ KERF CUTS
ALL STANDING SEAM ROOFS TO BE PROTECTED
THROUGHOUT WITH ENGINEERED SNOW FENCES
PER MANF. RECOMMENDATIONS PER ROOF PITCH
AND SNOW LOADS
2X6 WALL IN-FILL BTW GLULAM
RAFTERS
GLULAM RAFTERS
RE: STRUCT.
1X6 T&G SOFFIT W/ 1/8" X 1/8"
JOINT
GRID
LINE
RE: ROOF PLAN
CONT. BUG SCREEN STAPLED TO
SOFFIT WRAPPED OVER AIR VENT
MATERIAL TO CREATE MIN 1/2"
VENT AT TOP OF THE WALL.
6 1/2" STRUCTURALLY INSULATED
PANEL R-42+/- RE: SPEC
RE: STRUCT.
GLULAM RAFTER
T.O. WALL / GLULAM BEAM
RE: ELEVS AND SECTS
VARIES
2 5/8" INSULATION PANEL CONSISTING
OF: 2" RIGID FOAM GLUED TO 5/8"
PLYWOOD TOP SHEET R-10 +/-.
SCREW TO WALL W/ MIN. 4 SCREWS IN
PATTERN SIMILAR TO NAIL PATTERN
REQ'D. FOR STRUCT. SHEATHING RE:
SPEC.
3D DRAINAGE MEDIUM CONT. BEHIND
SIDING TO AIR VENT MATERIAL AT TOP
OF WOOD SIDING
SIDING INSTALLED OVER 3D DRAINAGE MEDIUM
RE: ELEVATIONS FOR LOCATION AND TYPE
7 1/4"
SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC
A6.3
7
CONT. BUG SCREEN STAPLED TO
SOFFIT WRAPPED OVER AIR VENT
MATERIAL TO CREATE MIN 1/2"
VENT AT TOP OF THE WALL.
COPPER GUTTER WITH ROUND DOWN
SPOUTS TO MATCH EXISTING
RE: ROOF PLANS FOR LOCATIONS
COPPER DRIP EDGE FLASHING RE: SPEC
SEE 4/A6.3 FOR TYP. GLULAM ROOF
ASSEMBLY
2X8 FURRED SPACE
2X6 WALL IN-FILL BTW CURVED GLULAM
RAFTERS
CURVED GLULAM RAFTERS
RE: STRUCT.
RE: ELEVATIONS FOR SIDING TYPE.
GRID
LINE
RE: ROOF PLAN
RE: STRUCT.
GLULAM RAFTER
T.O. WALL
RE: ELEVS AND SECTS
A6.3
7
GRID
LINE
2X8 FURRED SPACE BTW
GLULAM ROOF RAFTERS
TYP. ROOF ASSEMBLY AT GLULAM
ROOF STRUCTURE SEE 4/A6.3
1X6 T&G DECKING SOFFIT AND
CEILING
RE: ROOF PLAN
RE: ELEVATIONS FOR SIDING
TYP
GLULAM ROOF RAFTERS
SEE RCP FOR GLULAM
LOCATIONS RE: STRUCT.
6" TYP.
GLULAM SHOULDER BEAM
BEYOND RE: STRUCT.
A6.3
7
GRID
LINE
RAFTERS OR GLULAM
RE: STRUCT./SPEC.
CONT. BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO
CREATE MIN 1/2" VENT AT TOP OF THE
WALL.
1/2"
1/2"
2 5/8" INSULATION PANEL CONSISTING OF:
2" OF RIGID FOAM GLUED TO 5/8" PLYWOOD
TOP SHEET R -12.9+/- SCREW TO WALL W/
MIN. 5" LONG SCREWS IN PATTERN PER
DETAIL 5/A6.3 AND PER PANEL MANUF.
RECOMMENDATION RE: SPEC
SIDING
RE: ELEVATIONS FOR TYPE / NOTES
AND FINISHED SCHEDULE
3D DRAINAGE MEDIUM CONT. BEHIND
STONE TO AIR VENT MATERIAL AT TOP OF
WOOD SIDING. HOLD DOWN 1/2" FROM
B.O. SIDING
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
2/3/2015 3:36:31 PM
A6.3
DETAILS
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1 1/2" = 1'-0"
1 FOUNDATION DETAIL @ STAIR
1 1/2" = 1'-0"
2
FOUNDATION DETAIL @ STONE VENEER
@ GRADE
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ WINDOW @
PATIO
1 1/2" = 1'-0"
4
ROOF UPPER EAVE @ GLULAM ROOF
STRUCTURE
1 1/2" = 1'-0"
5
ROOF EAVE @ GLULAM ROOF
STRUCTURE
1 1/2" = 1'-0"
6
ROOF RAKE @ GLULAM ROOF
STRUCTURE
6" = 1'-0"
7 BUG SCREEN DETAIL @ ROOF EAVE
No. Revision Date
Revision
Description
07/31/15