HomeMy WebLinkAboutB15-0026_A6.3_1438367880.pdfT.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE 1' - 1" 2' - 0" 2' - 0" RE: STRUCT. SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY 9" P.T. 2X PLATE SEE 4/A6.1 FOR TYP. STONE VENEER WALL ASSEMBLY MIRA DRAIN DRAINAGE MEDIUM OVER 4" RIGID INSULATION MIN. R-20. MIRA DRAIN IS CONT. @ HORIZONTAL JOGS TO ALLOW WALL TO DRAIN TO FOUNDATION PERIMETER DRAIN OVER GRAVEL RE: SPEC BITHUTHANE ON TOP OF P.T. PLYWOOD EXTENDS MIN. 18" ABOVE FINISHED GRADE AND 12" BELOW LOWEST HORIZONTAL JOG IN CONC. WALL LINE OF FINISHED FLOOR BEYOND 3" 1 1/2" 6" MIN. 11 1/2" 1 1/2" 1' - 0 3/4" ANGLE SUPPORT RE: STRUCT. T.O. CONC @ 8304' - 3 3/4" RE: PLANS T.O. CONC. LEDGE @ 8303' - 3" RE: PLANS 5" 1/2" 3 1/2" T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE 1' - 3" 1 1/2" 2 1/4" 2' - 0" 2' - 0" 2' - 5" 7" 8" T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS 6" MIN. 6" MIN. SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY SEE 4/A6.1 FOR TYP. STONE VENEER WALL ASSEMBLY SLOPE T.O. PLYWOOD RE: PLANS INTERIOR INTERIOR EXTERIOR GRID LINE 1 1/2" 2 1/4" 2' - 0" 2' - 0" 4" 3" 8" T.O. CONC. RE: PLANS T.O. CONC. RE: PLANS SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY SEE 1/A6.1 FOR TYPICAL W.P. FOUNDATION ASSEMBLY SLOPE PER PLANS SEE 1/A6.1 FOR TYP. PATIO ASSEMBLY TRIM BRD. BEYOND WINDOW SET IN A BED OF SEALANT STONE VENEER BEYOND TRIM @ WINDOW WD. JAMB BEYOND CUT NAILING FLANGE @ WINDOW SILL TO ALLOW FLASHING UNDER SILL 3 1/8" 5/8" PLYWD. OVER FRAMING P.T. 2X6 RIPPED TO FIT FOR SUPPORT WINDOW FLASHING TO MATCH ROOFING MATERIAL RE: SPEC AEP SPAN STANDING SEAM ROOF RE: SPEC 2X8 WOOD FASCIA W/ KERF CUTS HIGH TEMP. VYCOR ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC 2X10 WOOD SUB-FASCIA W/ KERF CUTS ALL STANDING SEAM ROOFS TO BE PROTECTED THROUGHOUT WITH ENGINEERED SNOW FENCES PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS 2X6 WALL IN-FILL BTW GLULAM RAFTERS GLULAM RAFTERS RE: STRUCT. 1X6 T&G SOFFIT W/ 1/8" X 1/8" JOINT GRID LINE RE: ROOF PLAN CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 6 1/2" STRUCTURALLY INSULATED PANEL R-42+/- RE: SPEC RE: STRUCT. GLULAM RAFTER T.O. WALL / GLULAM BEAM RE: ELEVS AND SECTS VARIES 2 5/8" INSULATION PANEL CONSISTING OF: 2" RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R-10 +/-. SCREW TO WALL W/ MIN. 4 SCREWS IN PATTERN SIMILAR TO NAIL PATTERN REQ'D. FOR STRUCT. SHEATHING RE: SPEC. 3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO AIR VENT MATERIAL AT TOP OF WOOD SIDING SIDING INSTALLED OVER 3D DRAINAGE MEDIUM RE: ELEVATIONS FOR LOCATION AND TYPE 7 1/4" SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC A6.3 7 CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. COPPER GUTTER WITH ROUND DOWN SPOUTS TO MATCH EXISTING RE: ROOF PLANS FOR LOCATIONS COPPER DRIP EDGE FLASHING RE: SPEC SEE 4/A6.3 FOR TYP. GLULAM ROOF ASSEMBLY 2X8 FURRED SPACE 2X6 WALL IN-FILL BTW CURVED GLULAM RAFTERS CURVED GLULAM RAFTERS RE: STRUCT. RE: ELEVATIONS FOR SIDING TYPE. GRID LINE RE: ROOF PLAN RE: STRUCT. GLULAM RAFTER T.O. WALL RE: ELEVS AND SECTS A6.3 7 GRID LINE 2X8 FURRED SPACE BTW GLULAM ROOF RAFTERS TYP. ROOF ASSEMBLY AT GLULAM ROOF STRUCTURE SEE 4/A6.3 1X6 T&G DECKING SOFFIT AND CEILING RE: ROOF PLAN RE: ELEVATIONS FOR SIDING TYP GLULAM ROOF RAFTERS SEE RCP FOR GLULAM LOCATIONS RE: STRUCT. 6" TYP. GLULAM SHOULDER BEAM BEYOND RE: STRUCT. A6.3 7 GRID LINE RAFTERS OR GLULAM RE: STRUCT./SPEC. CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 1/2" 1/2" 2 5/8" INSULATION PANEL CONSISTING OF: 2" OF RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R -12.9+/- SCREW TO WALL W/ MIN. 5" LONG SCREWS IN PATTERN PER DETAIL 5/A6.3 AND PER PANEL MANUF. RECOMMENDATION RE: SPEC SIDING RE: ELEVATIONS FOR TYPE / NOTES AND FINISHED SCHEDULE 3D DRAINAGE MEDIUM CONT. BEHIND STONE TO AIR VENT MATERIAL AT TOP OF WOOD SIDING. HOLD DOWN 1/2" FROM B.O. SIDING Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 2/3/2015 3:36:31 PM A6.3 DETAILS AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET 1 1/2" = 1'-0" 1 FOUNDATION DETAIL @ STAIR 1 1/2" = 1'-0" 2 FOUNDATION DETAIL @ STONE VENEER @ GRADE 1 1/2" = 1'-0" 3 FOUNDATION DETAIL @ WINDOW @ PATIO 1 1/2" = 1'-0" 4 ROOF UPPER EAVE @ GLULAM ROOF STRUCTURE 1 1/2" = 1'-0" 5 ROOF EAVE @ GLULAM ROOF STRUCTURE 1 1/2" = 1'-0" 6 ROOF RAKE @ GLULAM ROOF STRUCTURE 6" = 1'-0" 7 BUG SCREEN DETAIL @ ROOF EAVE No. Revision Date Revision Description 07/31/15