HomeMy WebLinkAboutB15-0026_A6.4_1438367880.pdfGRID
LINE
3"
T.O. PLATE
RE: ELEVS AND SECTIONS
2X BLOCKING PER STRUCTURAL
DRAWINGS
RE: ROOF PLAN
CONT. BUG SCREEN STAPLED TO
SOFFIT WRAPPED OVER AIR VENT
MATERIAL TO CREATE MIN 1/2"
VENT AT TOP OF THE WALL.
COPPER GUTTER WITH ROUND DOWN SPOUTS
RE: ROOF PLANS FOR LOCATIONS
FLASHING TO MATCH ROOFING MATERIAL RE: SPEC
AEP SPAN STANDING SEAM ROOF
RE: SPEC
2X10 WOOD FASCIA W/ KERF CUTS
HIGH TEMP. VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP) FOR
FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
ALL STANDING SEAM ROOFS TO BE
PROTECTED THROUGHOUT WITH ENGINEERED
SNOW FENCES PER MANF.
RECOMMENDATIONS PER ROOF PITCH AND
SNOW LOADS RE: SPEC.
2X6 T&G DOUG-FIR DECKING W/ 1/8" X 1/8"
REVEAL JOINT
RE: ELEVATIONS FOR SIDING TYPE.
6 1/8" RIGID INSULATION PANEL WITH 5/8"
PLYWOOD SHEATHING GLUED TO 5 1/2"
CONTINUOUS RIGID INSULATION PANEL R-
25 MIN.
30# FELT UNDERLAYMENT NOT REQUIRED
BUT A DRY IN OPTION FOR CONTRACTOR.
PRODUCT MUST BE VAPOR PERMEABLE.
12
2
3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO
AIR VENT MATERIAL AT TOP
7 1/2"
4X8 WOOD TIMBERS RE: RCPS AND
STRUCT.
GRID
LINE
2X BLOCKING PER
STRUCTURAL DRAWINGS
FLASHING TO MATCH ROOFING MATERIAL RE: SPEC
AEP SPAN STANDING SEAM ROOF
RE: SPEC
HIGH TEMP. VYCOR ICE AND
WATER SHIELD - LAPS OVER
BALLOON FRAMED WALL
RE: SPEC
RE: ELEVATIONS FOR SIDING TYPE.
6 1/8" RIGID INSULATION PANEL
WITH 5/8" PLYWOOD SHEATHING
GLUED TO 5 1/2" CONTINUOUS
RIGID INSULATION PANEL R-25 MIN.
3D DRAINAGE MEDIUM CONT. BEHIND
SIDING TO AIR VENT MATERIAL AT TOP
12
2
SEPARATE COPPER PANELS FROM
C-CHANNEL W/ SEALANT AND ICE
AND WATER SHIELD TYPE STRIP
FLASHING
T.O. PLATE
RE: ELEVS AND SECTIONS
FLASHING CAP SLOPED TO DRAIN CLIPS
OVER TOP OF C-CHANNEL
LVL RIM RE:STRUCT.
6"
STEEL I-BEAM RE: STRUCT.
KNIFE PLATE, THROUGH
BOLT WITH COUNTER SINK
BEAM TO GLULAM
RE:STRUCT.
GLULAM JOIST RE:STRUCT.
SHIM RIPPED AT 1/8" PER 1'-0"
3/4" PLYWOOD SLOPED AT 1/8"
PER 1'-0"
W.P. MEMBRANE RE: SPEC.
DRAINAGE BOARD SLOPES AT
1/8" PER 1'-0"
4" STONE ASSEMBLY- APPROX 2"
OF STONE OVER 1/2" OF GROUT
OVER 1 1/2" CONC. SLAB WITH
RADIANT TUBING
3 1/2" L X 6 " W X 3/4" T STEEL PLATE
PAINTED TO MATCH WINDOW COLOR
LAG BOLTED THROUGH TO END OF
GLULAM
PAINTED TO MATCH WINDOW COLOR 1 1/2"
W X 4'-0" H X 1/2" T STANCHIONS EACH
STANCHION WELDED TO STEEL PLATE
BELOW
PAINTED TO MATCH WINDOW COLOR
3/8" X 3/8" SQUARE STEEL RODS
WELDED TO TOP AND BOTTOM
STRAP @ 4" O.C.
PAINTED TO MATCH WINDOW
COLOR 3 1/2" W X 1 1/2" H X 3/8" T
STEEL WELDED TO TOP
STANCHIONS WITH TOP GRINDED TO
30 DEGREE ANGLE
CONT. PAINTED TO MATCH WINDOW
COLOR 3" W X 1/2" THICK STEEL PLATE AT
30 DEGREES ANGLE CENTERED AND
WELDED TO PLATE BELOW
W.P. MEMBRANE ADHERES TO
COPPER FLASHING WHICH
EXTENDS OVER EDGE WITH A DRIP
EDGE AS SHOWN
1 1/2"
3 3/4"
3' - 9 7/16"
1 /2"
3 1/2"
30.0°
1' - 4 5/16" 1/2" 2' - 4 1/8" 1/2" 4 1/8"
3 15/16"
3/8"
PAINTED TO MATCH WINDOW COLOR 1
1/2" W X 1/2" T STEEL TOP STRAP
1 1/2"
PAINTED TO MATCH WINDOW COLOR 1
1/2" W X 1/2" T STEEL BOTTOM STRAP
CONT. 6" W X 1/4" THICK STEEL PLATE
PAINTED TO MATCH WINDOW COLOR
WELDED TO STANCHIONS
RE: PLANS
TUBE STEEL COLUMN RE: STRUCT.
SLOPED STONE CAP
CANTED SIDE OF STONE COLUMN
USE PRESSURE TREATED FRAMING AND PLYWOOD AT ALL EXT.
STONE COLUMNS
W.P. MEMBRANE RUNS UP HSS COLUMN TO T.O. STONE
CAP ABOVE W.P. MEMBRANE TURNS UP 4X4 STEEL
COLUMN SUPPORT 3 1/2". INSTALL SEALANT BETWEEN
STONE AND COLUMN.
PROVIDE COPPER GUTTER BETWEEN
RAILING AND EDGE OF DECK SEE
PLANS FOR DOWN SPOUT LOCATIONS
3 1/2"
6" 4"
STEEL I-BEAM RE: STRUCT.
GLULAM JOIST RE:STRUCT.
3 1/2" L X 6" W X 3/4" T STEEL PLATE PAINTED TO
MATCH WINDOW COLOR LAG BOLTED THROUGH
TO END OF GLULAM
PAINTED TO MATCH WINDOW COLOR 1 1/2" W X 4'-0" H X
1/2" T STANCHIONS EACH STANCHION WELDED TO
STEEL PLATE BELOW
PAINTED TO MATCH WINDOW COLOR 3/8" X 3/8"
SQUARE STEEL RODS WELDED TO TOP AND
BOTTOM STRAP @ 4" O.C.
PAINTED TO MATCH WINDOW COLOR 4 1/8" H X 1 1/2"
W X 3/8" T STEEL WELDED TO TOP STANCHIONS WITH
TOP GRINDED TO 30 DEGREE ANGLE
CONT. PAINTED TO MATCH WINDOW COLOR 3" W X
1/2" THICK STEEL PLATE AT 30 DEGREES ANGLE
CENTERED AND WELDED TO PLATE BELOW
W.P. MEMBRANE ADHERES TO COPPER
FLASHING WHICH EXTENDS OVER EDGE
WITH A DRIP EDGE AS SHOWN
PAINTED TO MATCH WINDOW COLOR 1 1/2" W X
1/2" T STEEL TOP STRAP
PAINTED TO MATCH WINDOW COLOR 1 1/2" W X
1/2" T STEEL BOTTOM STRAP
CONT. 6" W X 1/4" THICK STEEL PLATE PAINTED TO
MATCH WINDOW COLOR WELDED TO STANCHIONS 4 1/8"
1 1/2"
1/2"
3' - 8 15/16"
3 3/4"
1/2" 2' - 4 1/8"
1/2" 2 5/16" 6" 2" 3' - 1"
INFILL BETWEEN STANCHIONS WITH 3 1/2" IPE
BOARD W/ 3/8" REVEAL ALL SIDES MATCH TRIM
COLOR
1/2" X 1 1/2" STEEL BOTTOM PLATE
3/8"
GRID
LINE
2X BLOCKING PER
STRUCTURAL DRAWINGS
FLASHING TO MATCH ROOFING MATERIAL RE: SPEC
AEP SPAN STANDING SEAM ROOF
RE: SPEC
HIGH TEMP. VYCOR ICE AND
WATER SHIELD - LAPS OVER
BALLOON FRAMED WALL
RE: SPEC
TYP. STONE VENEER WALL
ASSEMBLY.
6 1/8" RIGID INSULATION PANEL
WITH 5/8" PLYWOOD SHEATHING
GLUED TO 5 1/2" CONTINUOUS
RIGID INSULATION PANEL R-25 MIN.
3D DRAINAGE MEDIUM CONT. BEHIND
SIDING TO AIR VENT MATERIAL AT TOP
12
2
T.O. PLATE
RE: ELEVS AND SECTIONS
FLASHING CAP SLOPED TO DRAIN CLIPS
OVER TOP OF SLOPED STONE CAP
LVL RIM RE:STRUCT.
2X8 WOOD FASCIA W/ KERF CUTS
2X10 WOOD SUB-FASCIA W/
KERF CUTS
2X6 WALL IN-FILL BTW GLULAM
RAFTERS
CHIMNEY CHASE
GRID
LINE
RE: ROOF PLAN
RE: STRUCT.
GLULAM RAFTER
T.O. WALL
RE: ELEVS AND SECTS
VARIES7 1/4"
ANGLE RE: STRUCT
NOTCH GLULAM TO ACCEPT
ANGLE AND LAG BOLTS
CRICKET RE: ROOF PLAN
T.O. WALL
RE: ELEVS AND SECTS
1' - 6"
GRID
LINE
GRID
LINE
SEE 4/A6.3 FOR TYP. GLULAM
ROOF ASSEMBLY
KNIFE PLATE RE: STRUCT.
STEEL BEAM RE: STRUCT.
10X10 WOOD STRUT RE: STUCT.
3' - 0"
MOUNT LIGHT TO STEEL PLATE
WELD ALL THREAD TO STEEL
I-BEAM TO ALLOW
ATTACHMENT OF STEEL
PLATE
7"
STEEL PLATE BOLTED TO ALL THREAD
1 1/2"
2X BLOCKING TO CREATE WIRE CHASE
STEEL BEAM RE: STRUCT.
A8.1
1
1' - 3 7/16"
14.000°
3' - 10 1/8"
4"
A8.1
11
METAL DRIP EDGE FLASHING TO MATCH ROOF
RE: SPEC
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DOUG-FIR DECKING W/ 1/8" X 1/8"
REVEAL JOINT RE: STRUCTURAL
HIGH TEMP. VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP) FOR
FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
ROOFS TO BE PROTECTED THROUGHOUT WITH
ENGINEERED SNOW PADS PER MANF.
RECOMMENDATIONS PER ROOF PITCH AND SNOW
LOADS RE: SPEC
STEEL I-BEAM RE: RCP AND
STRUCT. FOR SIZING
T.O. STEEL BEAM
RE: STRUCT.
KNIFE PLATE WITH SURFACE MOUNTED
THROUGH BOLTS RE: STRUCT.
GLULAM RAFTERS RE: STRUCT.
5/8" PLYWOOD SHEATHING
RE: STRUCT.
STEEL BRACKET WELDED
TO T.O BEAM
RE: STRUCT. FOR SIZING
AND LOCATION
SIM. CONDITION @ OPPOSITE
END OF ROOF
TUBE STEEL COLUMN RE: STRUCT.
SLOPED STONE CAP
USE PRESSURE TREATED FRAMING AND
PLYWOOD AT ALL EXT. STONE COLUMNS
W.P. MEMBRANE RUNS UP HSS COLUMN TO
T.O. STONE CAP ABOVE. W.P. MEMBRANE
TURNS UPSTEEL COLUMN 3 1/2". INSTALL
SEALANT BETWEEN STONE AND COLUMN.
C-CHANNEL BEYOND WELDED TO STEEL COLUMN
MOUNT MONOPOINT LIGHT TO STEEL COLUMN
1/2" T STEEL PLATE AT B.O. C-CHANNELS
1X FURRING STRIPS TO CREATE WIRING
CHASE FOR EXT. MONOPOINTS
TUBE STEEL COLUMN RE: STRUCT.
SLOPED STONE CAP
LINE OF PRESSURE TREATED FRAMING AND
PLYWOOD BELOW
C-CHANNEL WELDED TO
STEEL COLUMN
MOUNT MONOPOINT LIGHT TO STEEL COLUMN
1/2" T STEEL PLATE AT B.O. C-CHANNELS
LINE OF STONE VENEER BELOW
6"
METAL DRIP EDGE FLASHING TO MATCH ROOF
RE: SPEC
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DOUG-FIR DECKING W/ 1/8" X 1/8"
REVEAL JOINT RE: STRUCTURAL
HIGH TEMP. VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP) FOR
FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
STEEL I-BEAM RE: RCP AND
STRUCT. FOR SIZING
KNIFE PLATE WITH SURFACE MOUNTED
THROUGH BOLTS RE: STRUCT.
GLULAM RAFTERS
RE: STRUCT.
5/8" PLYWOOD SHEATHING
RE: STRUCT.
STEEL BRACKET WELDED
TO T.O BEAM
RE: STRUCT. FOR SIZING
AND LOCATION
TUBE STEEL COLUMN RE: STRUCT.
SLOPED STONE CAP
C-CHANNELS WELDED TO STEEL COLUMN
1/2" T STEEL PLATE AT B.O. C-CHANNELS
1X FURRING STRIPS TO CREATE WIRING
CHASE FOR EXT. MONOPOINTS
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
3D DRAINAGE MEDIUM LAPS
OVER BUILDING PAPER LAPS
OVER TOP OF FLASHING 1
1/2" MIN AND CONT. UP WALL
LAP WATERPROOF MEMBRANE
OVER NAILING FLANGE AND
CONTINUE UP UNDER FLASHING
AND UNDER BUILDING PAPER
CURVED MC 18x45.8 C-CHANNEL
STEEL HEADER PAINTED TO MATCH
WINDOW FINISH LAG BOLTED
THROUGH CENTER OF C-CHANNEL
TO WINDOW HEADER RE: STRUCT.
GRID
LINE
JAMB EXTENSION AT WINDOW HEAD
INTERIOR
EXTERIOR
METAL FLASHING WITH DRIP EDGE TO MATCH
WINDOW COLOR
HEADER RE: STRUCT.
2" RIGID FOAM PANEL GLUED
TO 5/8" PLYWOOD TOP
SHEET R-12.5 +/- RE: SPEC.
STONE SIDING RE: ELEVATION & SPEC
INSTALL P.T 1X BEHIND STEEL
C- CHANNEL HEADER
PROVIDE WEEPS OVER FLASHING @
B.O STONE OVER ROOFING RE:SPEC
RE: RCP & STRUCT
ENTRY ROOF RE: DETAIL 3/A6.7 FOR
DETAILED ASSEMBLY
(2) P.T PLATES UNDER STONE
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
2/3/2015 3:36:34 PM
A6.4
DETAILS
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1 1/2" = 1'-0"
1
ROOF EAVE @ SHED ROOF
1 1/2" = 1'-0"
2
ROOF EAVE @ SHED ROOF PARAPET @
COPPER PANEL
1 1/2" = 1'-0"
3 W.P. STONE DECK AND RAILING DETAIL
1 1/2" = 1'-0"
4
W.P. STONE DECK AND RAILING DETAIL
ELEVATION
1 1/2" = 1'-0"
5
ROOF EAVE @ SHED ROOF PARAPET @
STONE VENEER
1 1/2" = 1'-0"
6
ROOF UPPER EAVE @ GLULAM ROOF @
STRUCTURAL FASCIA
1 1/2" = 1'-0"
7
ROOF EAVE @ LOW ROOF @ LIVING
ROOM
1 1/2" = 1'-0"
8
ROOF EAVE @ ENTRY ROOF
1 1/2" = 1'-0"
9
COLUMN PLAN @ ENTRY ROOF
1 1/2" = 1'-0"
10 ROOF RAKE @ ENTRY
1 1/2" = 1'-0"
11
ROOF ENTRY HEADER
No. Revision Date
Revision
Description
07/31/15