Loading...
HomeMy WebLinkAboutB15-0026_A6.5_1438367880.pdfT.O. PLYWOOD RE: SECTIONS / PLANS INTERIOR FINISHED FLOOR RE: PLANS, SPEC & INTERIORS 3/4" PLYWOOD RE: STRUCT. WOOD I-JOISTS RE: STRUCT. STEEL BEAM RE: STRUCT. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND OVER P.T BLOCKING AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE DOOR RE: SCHED. GRID LINE INTERIOR RE:PLAN COPPER SIDING RE: ELEVATION & SPEC 5/8" GWB 1' - 2" T.O. PLATE RE: SECTIONS CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 1 1/2" GYP W/ RADIANT HEAT TUBING RE: SPEC 2 LAYERS OF P.T BLOCKING TYP. DECK ASSEMBLY SEE 3/A6.4 EXTERIOR 3 1/2" T.O. PLYWOOD RE: SECTIONS / PLANS INTERIOR FINISHED FLOOR RE: PLANS, SPEC & INTERIORS SEE 1/A6.5 FOR TYP. FLOOR/WALL ASSEMBLY RIM JOIST RE: STRUCT. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND OVER P.T BLOCKING AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE DOOR RE: SCHED. GRID LINE INTERIOR RE:PLAN 1' - 2" T.O. PLATE RE: SECTIONS 2 LAYERS OF P.T BLOCKING SEE 3/A6.4 FOR TYP. DECK ASSEMBLY EXTERIOR T.O. PLYWOOD RE: SECTIONS / PLANS SEE 1/A6.5 FOR TYP. FLOOR/WALL ASSEMBLY HEADER RE: STRUCT. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND OVER P.T BLOCKING AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE WINDOW RE: SCHED. GRID LINE INTERIOR 2 LAYERS OF P.T BLOCKING SEE 3/A6.4 FOR TYP. DECK ASSEMBLY EXTERIOR WINDOW SET IN A BED OF SEALANT TRIM @ WINDOW 3 1/2" 4" T.O. PLYWOOD RE: SECTIONS / PLANS GLU LAM JOIST RE: STRUCT. DROPPED GRID X CEILING RE: SPEC. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND OVER P.T BLOCKING AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE WINDOW RE: SCHED. GRID LINE GARAGE 2 LAYERS OF P.T BLOCKING SEE 3/A6.4 FOR TYP. DECK ASSEMBLY EXTERIOR WINDOW SET IN A BED OF SEALANT TRIM @ WINDOW GRID LINE PACK OUT FOR PANEL ATTACHMENT RE: STRUCT. C-CHANNEL HEADER BOLTED TO BEAM COPPER FLASHING GARAGE DOOR RE: DOOR SCHEDULE HEADER RE: STRUCT. 1X10 WOOD TRIM 1X4 WOOD TRIM GARAGE DOOR AND TRACK PER SPECIFICATIONS WEATHER STRIPPING 6 3/8" OVER FRAMING RE: STRUCT. 6 1/2" 1' - 0" 2' - 6" 4" T.O. PLYWOOD RE: SECTIONS / PLANS GLU LAM JOIST RE: STRUCT. DROPPED GRID X CEILING RE: SPEC. W.P. MEMBRANE CONT. MIN. 1'-6" UP WALLS AND OVER P.T BLOCKING AND CONT. UNDER DOOR SILL COPPER FLASHING CONT. UNDER DOOR SILL W/ 1" LEG CONT. OUT OVER STONE WINDOW RE: SCHED. GARAGE 2 LAYERS OF P.T BLOCKING SEE 3/A6.4 FOR TYP. DECK / RAILING ASSEMBLY EXTERIOR WINDOW SET IN A BED OF SEALANT TRIM @ WINDOW GRID LINE PACK OUT FOR PANEL ATTACHMENT RE: STRUCT. C-CHANNEL HEADER BOLTED TO BEAM FLASHING DOOR RE: WINDOW SCHEDULE HEADER RE: STRUCT. 6 3/8" OVER FRAMING RE: STRUCT. 1' - 6 1/2" APPLIED STEEL BEAM BEYOND ATTACHES TO GLU-LAM ABOVE RE: STRUCT. 3' - 4 1/16" 1" 4" STEEL BEAM RE: STRUCT. SLOPED STONE CAP CONC. WALL W.P. MEMBRANE RUNS UP HSS COLUMN TO T.O. STONE CAP ABOVE. W.P. MEMBRANE TURNS UPSTEEL COLUMN 3 1/2". INSTALL SEALANT BETWEEN STONE AND COLUMN. MOUNT MONOPOINT LIGHT TO WOOD BEAM STEEL PLATE RE: STRUCT. TUBE STEEL COLUMN RE: STRUCT. 4X8 WOOD BEAM @ 2'-0" O.C. RE: STRUCT. COPPER FLASHING CAP 4X4 WOOD BEAM @ 2'-0" O.C. RE: STRUCT. COPPER FLASHING CAP 3" METAL DRIP EDGE FLASHING TO MATCH ROOF RE: SPEC STANDING SEAM METAL ROOF RE: SPEC 2X6 T&G DOUG-FIR DECKING W/ 1/8" X 1/8" REVEAL JOINT RE: STRUCTURAL HIGH TEMP. VYCOR ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC ROOFS TO BE PROTECTED THROUGHOUT WITH ENGINEERED SNOW PADS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: SPEC STEEL I-BEAM RE: RCP AND STRUCT. FOR SIZING T.O. STEEL BEAM RE: STRUCT. KNIFE PLATE WITH SURFACE MOUNTED THROUGH BOLTS RE: STRUCT. GLULAM RAFTERS RE: STRUCT. 5/8" PLYWOOD SHEATHING RE: STRUCT. STEEL BRACKET WELDED TO T.O BEAM RE: STRUCT. FOR SIZING AND LOCATION 1X FURRING STRIPS TO CREATE WIRING CHASE FOR EXT. MONOPOINTS 6" METAL DRIP EDGE FLASHING TO MATCH ROOF RE: SPEC STANDING SEAM METAL ROOF RE: SPEC 2X6 T&G DOUG-FIR DECKING W/ 1/8" X 1/8" REVEAL JOINT RE: STRUCTURAL HIGH TEMP. VYCOR ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC STEEL I-BEAM RE: RCP AND STRUCT. FOR SIZING KNIFE PLATE WITH SURFACE MOUNTED THROUGH BOLTS RE: STRUCT. GLULAM RAFTERS RE: STRUCT. 5/8" PLYWOOD SHEATHING RE: STRUCT. STEEL BRACKET WELDED TO T.O BEAM RE: STRUCT. FOR SIZING AND LOCATION 1X FURRING STRIPS TO CREATE WIRING CHASE FOR EXT. MONOPOINTS GRID LINE TYP. ROOF ASSEMBLY AT GLULAM ROOF STRUCTURE SEE 4/A6.3 RE: ROOF PLAN EXTEND ICE AND WATER SHIELD UP AND OVER ROOF TRANSITION MIN. 50% OVERLAP FOR FIRST 4' METAL FLASHING WITH DRIP EDGE EXTENDS OVER ROOFING TYP. SHED ROOF ASSEMBLY SEE 1/A6.4 TRIM BOTTOM OF GLU-LAM TO FIT T.O. PLYWOOD RE: SECTIONS / PLANS FINISHED FLOOR RE: PLANS, SPEC & INTERIORS STEEL BEAM RE: STRUCT. PACK OUT STEEL BEAM FOR HANGER ATTACHMENT RE: STRUCT. Z-FRY REGLET W/ 3/8" REVEAL 3/4" GUARD RAIL STANCHION 4" MAX. GWB SMART MEMBRANE VAPOR BARRIER RE: SPEC WOOD TRIM RE: ELEVATIONS & SPEC 10X10 WOOD STRUT RE: STRUCT HOLD METAL 1/8"-1/4" OFF STEEL KNIFE PLATE. FILL GAP WITH SEALANT JOINT WRAP PORTION OF MTL KNIFE PLATE STRUT SUPPORT WITHIN SIDING IN ICE AND WATERSHIELD & TO PROVIDE WATER TIGHT SEAL TO INSULATION PANEL. HOLD ICE AND WATER SHIELD BACK FROM FACE OF SIDING AND PROVIDE SEALANT JOINT. STEEL COLUMN STRUCTURALLY PROVIDED. WELD KNIFE PLATE TO COLUMN. RE: STRUCT. EXPOSED THROUGH BOLT CONNECTION RE:STRUCTURAL FOR COUNT & LOCATION STEEL KNIFE PLATE @ STRUT ANGLE WELD KNIFE PLAT TO COLUMN @ WALL. RE: STRUCT. PLUNGE CUT STRUT TO ACCEPT KNIFE PLATE RE: STRUCT 4 5/16" GRID LINE EXTEND ICE AND WATER SHIELD UP WALL MIN 36" METAL FLASHING WITH DRIP EDGE EXTENDS OVER ROOFING TYP. SHED ROOF ASSEMBLY SEE 1/A6.4 METAL PANEL SIDING SEE 4/A6.3 FOR TYP. WALL ASSEMBLY Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1 1/2" = 1'-0" 2/3/2015 3:36:36 PM A6.5 DETAILS AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET 1 1/2" = 1'-0" 1 STONE DECK @ WALL@ MASTER BEDROOM / FAMILY ROOM 1 1/2" = 1'-0" 2 STONE DECK @ WALL@ OFFICE / BAR 1 1/2" = 1'-0" 3 STONE DECK @ WALL@ WINDOW / LIVING ROOM 1 1/2" = 1'-0" 4 STONE DECK @ WALL@ GUEST MASTER / GARAGE 1 1/2" = 1'-0" 5 STONE DECK @ WALL@ GUEST MASTER / GARAGE MAN DOOR 1 1/2" = 1'-0" 6 TRELLIS DETAIL 1 1/2" = 1'-0" 7 ROOF EAVE @ MUD ROOM ENTRY 1 1/2" = 1'-0" 8 ROOF RAKE @ MUD ROOM ENTRY 1 1/2" = 1'-0" 9 ROOF RAKE @ GLULAM ROOF TO SHED ROOF 1 1/2" = 1'-0" 10 WALKWAY FLOOR DETAIL 1 1/2" = 1'-0" 11 STRUT TO WOOD SIDING CONNECTION 1 1/2" = 1'-0" 12 SHED ROOF TO WALL CONNECTION No. Revision Date Revision Description 07/31/15