HomeMy WebLinkAboutB15-0026_A6.5_1438367880.pdfT.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
FINISHED FLOOR RE: PLANS,
SPEC & INTERIORS
3/4" PLYWOOD RE: STRUCT.
WOOD I-JOISTS RE: STRUCT.
STEEL BEAM RE: STRUCT.
W.P. MEMBRANE CONT. MIN. 1'-6" UP
WALLS AND OVER P.T BLOCKING AND
CONT. UNDER DOOR SILL
COPPER FLASHING CONT. UNDER DOOR
SILL W/ 1" LEG CONT. OUT OVER STONE
DOOR RE: SCHED.
GRID
LINE
INTERIOR
RE:PLAN
COPPER SIDING RE: ELEVATION & SPEC
5/8" GWB
1' - 2"
T.O. PLATE
RE: SECTIONS
CONT. BUG SCREEN STAPLED TO
SOFFIT WRAPPED OVER AIR VENT
MATERIAL TO CREATE MIN 1/2" VENT
AT TOP OF THE WALL.
1 1/2" GYP W/ RADIANT HEAT TUBING
RE: SPEC
2 LAYERS OF P.T BLOCKING
TYP. DECK ASSEMBLY SEE 3/A6.4
EXTERIOR
3 1/2"
T.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
FINISHED FLOOR RE: PLANS,
SPEC & INTERIORS
SEE 1/A6.5 FOR TYP. FLOOR/WALL ASSEMBLY
RIM JOIST RE: STRUCT.
W.P. MEMBRANE CONT. MIN. 1'-6" UP
WALLS AND OVER P.T BLOCKING AND
CONT. UNDER DOOR SILL
COPPER FLASHING CONT. UNDER DOOR
SILL W/ 1" LEG CONT. OUT OVER STONE
DOOR RE: SCHED.
GRID
LINE
INTERIOR RE:PLAN
1' - 2"
T.O. PLATE
RE: SECTIONS
2 LAYERS OF P.T BLOCKING
SEE 3/A6.4 FOR TYP. DECK ASSEMBLY
EXTERIOR
T.O. PLYWOOD
RE: SECTIONS / PLANS
SEE 1/A6.5 FOR TYP.
FLOOR/WALL ASSEMBLY
HEADER RE: STRUCT.
W.P. MEMBRANE CONT. MIN. 1'-6" UP
WALLS AND OVER P.T BLOCKING AND
CONT. UNDER DOOR SILL
COPPER FLASHING CONT. UNDER DOOR
SILL W/ 1" LEG CONT. OUT OVER STONE
WINDOW RE: SCHED.
GRID
LINE
INTERIOR
2 LAYERS OF P.T BLOCKING
SEE 3/A6.4 FOR TYP. DECK ASSEMBLY
EXTERIOR
WINDOW SET IN A BED
OF SEALANT
TRIM @ WINDOW
3 1/2"
4"
T.O. PLYWOOD
RE: SECTIONS / PLANS
GLU LAM JOIST RE:
STRUCT.
DROPPED GRID X CEILING
RE: SPEC.
W.P. MEMBRANE CONT. MIN. 1'-6" UP
WALLS AND OVER P.T BLOCKING AND
CONT. UNDER DOOR SILL
COPPER FLASHING CONT. UNDER DOOR
SILL W/ 1" LEG CONT. OUT OVER STONE
WINDOW RE: SCHED.
GRID
LINE
GARAGE
2 LAYERS OF P.T BLOCKING
SEE 3/A6.4 FOR TYP. DECK ASSEMBLY
EXTERIOR
WINDOW SET IN A BED
OF SEALANT
TRIM @ WINDOW
GRID
LINE
PACK OUT FOR PANEL ATTACHMENT
RE: STRUCT.
C-CHANNEL HEADER BOLTED TO BEAM
COPPER FLASHING
GARAGE DOOR RE: DOOR SCHEDULE
HEADER RE: STRUCT.
1X10 WOOD TRIM
1X4 WOOD TRIM
GARAGE DOOR AND TRACK PER SPECIFICATIONS
WEATHER STRIPPING
6 3/8"
OVER FRAMING RE: STRUCT. 6 1/2" 1' - 0" 2' - 6" 4"
T.O. PLYWOOD
RE: SECTIONS / PLANS
GLU LAM JOIST RE:
STRUCT.
DROPPED GRID X CEILING
RE: SPEC.
W.P. MEMBRANE CONT. MIN. 1'-6" UP
WALLS AND OVER P.T BLOCKING AND
CONT. UNDER DOOR SILL
COPPER FLASHING CONT. UNDER DOOR
SILL W/ 1" LEG CONT. OUT OVER STONE
WINDOW RE: SCHED.
GARAGE
2 LAYERS OF P.T BLOCKING
SEE 3/A6.4 FOR TYP. DECK / RAILING ASSEMBLY
EXTERIOR
WINDOW SET IN A BED
OF SEALANT
TRIM @ WINDOW
GRID
LINE
PACK OUT FOR PANEL ATTACHMENT
RE: STRUCT.
C-CHANNEL HEADER BOLTED TO BEAM
FLASHING
DOOR RE: WINDOW SCHEDULE
HEADER RE: STRUCT.
6 3/8"
OVER FRAMING RE: STRUCT.
1' - 6 1/2"
APPLIED STEEL BEAM BEYOND
ATTACHES TO GLU-LAM ABOVE RE:
STRUCT.
3' - 4 1/16"
1" 4"
STEEL BEAM RE: STRUCT.
SLOPED STONE CAP
CONC. WALL
W.P. MEMBRANE RUNS UP HSS COLUMN TO
T.O. STONE CAP ABOVE. W.P. MEMBRANE
TURNS UPSTEEL COLUMN 3 1/2". INSTALL
SEALANT BETWEEN STONE AND COLUMN.
MOUNT MONOPOINT LIGHT
TO WOOD BEAM
STEEL PLATE RE: STRUCT.
TUBE STEEL COLUMN RE: STRUCT.
4X8 WOOD BEAM @ 2'-0" O.C. RE: STRUCT.
COPPER FLASHING CAP
4X4 WOOD BEAM @ 2'-0" O.C. RE: STRUCT.
COPPER FLASHING CAP
3"
METAL DRIP EDGE FLASHING TO MATCH ROOF
RE: SPEC
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DOUG-FIR DECKING W/ 1/8" X
1/8" REVEAL JOINT RE: STRUCTURAL
HIGH TEMP. VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP) FOR
FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
ROOFS TO BE PROTECTED THROUGHOUT WITH
ENGINEERED SNOW PADS PER MANF.
RECOMMENDATIONS PER ROOF PITCH AND SNOW
LOADS RE: SPEC
STEEL I-BEAM RE: RCP AND
STRUCT. FOR SIZING
T.O. STEEL BEAM
RE: STRUCT.
KNIFE PLATE WITH SURFACE MOUNTED
THROUGH BOLTS RE: STRUCT.
GLULAM RAFTERS RE: STRUCT.
5/8" PLYWOOD SHEATHING
RE: STRUCT.
STEEL BRACKET WELDED
TO T.O BEAM
RE: STRUCT. FOR SIZING
AND LOCATION
1X FURRING STRIPS TO CREATE WIRING
CHASE FOR EXT. MONOPOINTS
6"
METAL DRIP EDGE
FLASHING TO MATCH ROOF
RE: SPEC
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DOUG-FIR
DECKING W/ 1/8" X 1/8"
REVEAL JOINT RE:
STRUCTURAL
HIGH TEMP. VYCOR ICE AND WATER
SHIELD - PROVIDE DOUBLE LAYER
(50% OVERLAP) FOR FIRST 4' OF ROOF
ABOVE EAVE
RE: SPEC
STEEL I-BEAM RE: RCP AND
STRUCT. FOR SIZING
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS RE:
STRUCT.
GLULAM RAFTERS
RE: STRUCT.
5/8" PLYWOOD SHEATHING
RE: STRUCT.
STEEL BRACKET WELDED
TO T.O BEAM
RE: STRUCT. FOR SIZING
AND LOCATION
1X FURRING STRIPS TO CREATE WIRING
CHASE FOR EXT. MONOPOINTS
GRID
LINE
TYP. ROOF ASSEMBLY AT
GLULAM ROOF STRUCTURE
SEE 4/A6.3
RE: ROOF PLAN
EXTEND ICE AND WATER
SHIELD UP AND OVER
ROOF TRANSITION MIN.
50% OVERLAP FOR FIRST
4'
METAL FLASHING WITH DRIP EDGE
EXTENDS OVER ROOFING
TYP. SHED ROOF
ASSEMBLY SEE 1/A6.4
TRIM BOTTOM OF GLU-LAM TO FIT
T.O. PLYWOOD
RE: SECTIONS / PLANS
FINISHED FLOOR RE: PLANS,
SPEC & INTERIORS
STEEL BEAM RE: STRUCT.
PACK OUT STEEL BEAM
FOR HANGER
ATTACHMENT RE:
STRUCT.
Z-FRY REGLET W/ 3/8" REVEAL
3/4"
GUARD RAIL STANCHION
4" MAX.
GWB
SMART MEMBRANE
VAPOR BARRIER RE:
SPEC
WOOD TRIM
RE: ELEVATIONS & SPEC
10X10 WOOD
STRUT
RE: STRUCT
HOLD METAL 1/8"-1/4"
OFF STEEL KNIFE
PLATE. FILL GAP WITH
SEALANT JOINT
WRAP PORTION OF MTL KNIFE PLATE STRUT SUPPORT
WITHIN SIDING IN ICE AND WATERSHIELD & TO
PROVIDE WATER TIGHT SEAL TO INSULATION PANEL.
HOLD ICE AND WATER SHIELD BACK FROM FACE OF
SIDING AND PROVIDE SEALANT JOINT.
STEEL COLUMN STRUCTURALLY
PROVIDED. WELD KNIFE PLATE
TO COLUMN.
RE: STRUCT.
EXPOSED THROUGH BOLT
CONNECTION
RE:STRUCTURAL FOR COUNT
& LOCATION
STEEL KNIFE PLATE @ STRUT ANGLE
WELD KNIFE PLAT TO COLUMN @
WALL.
RE: STRUCT.
PLUNGE CUT STRUT
TO ACCEPT KNIFE
PLATE
RE: STRUCT
4 5/16"
GRID
LINE
EXTEND ICE AND WATER
SHIELD UP WALL MIN 36"
METAL FLASHING WITH DRIP EDGE
EXTENDS OVER ROOFING
TYP. SHED ROOF
ASSEMBLY SEE 1/A6.4
METAL PANEL SIDING
SEE 4/A6.3 FOR TYP.
WALL ASSEMBLY
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
2/3/2015 3:36:36 PM
A6.5
DETAILS
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1 1/2" = 1'-0"
1
STONE DECK @ WALL@ MASTER
BEDROOM / FAMILY ROOM
1 1/2" = 1'-0"
2 STONE DECK @ WALL@ OFFICE / BAR
1 1/2" = 1'-0"
3
STONE DECK @ WALL@ WINDOW /
LIVING ROOM
1 1/2" = 1'-0"
4
STONE DECK @ WALL@ GUEST MASTER
/ GARAGE
1 1/2" = 1'-0"
5
STONE DECK @ WALL@ GUEST MASTER
/ GARAGE MAN DOOR
1 1/2" = 1'-0"
6 TRELLIS DETAIL
1 1/2" = 1'-0"
7
ROOF EAVE @ MUD ROOM ENTRY
1 1/2" = 1'-0"
8 ROOF RAKE @ MUD ROOM ENTRY
1 1/2" = 1'-0"
9
ROOF RAKE @ GLULAM ROOF TO SHED
ROOF
1 1/2" = 1'-0"
10 WALKWAY FLOOR DETAIL
1 1/2" = 1'-0"
11
STRUT TO WOOD SIDING CONNECTION
1 1/2" = 1'-0"
12 SHED ROOF TO WALL CONNECTION
No. Revision Date
Revision
Description
07/31/15