HomeMy WebLinkAboutB15-0026_A7.1_1438367880.pdfGENERAL NOTES: 1.) INSTALL GAS LOG SET AND BURNER PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 2.) INSTALL EXCEL MODEL RIS CHIMNEY PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 6 7 8 A B LIVING ROOM SLIDING DOOR Q Q C C B A7.1 2 A7.1 3 2 A5.3 1 A5.2 A8.0 4 1 A7.2 2 A7.2 2' - 6 1/2" 5 1/2" 2' - 7 3/4" 5 1/2" 2' - 4 1/4" 5 1/2" CANTED WALL CANTED WALL 9' - 3" 9' - 9" 3' - 11 1/4" OPENING 3' - 11 1/4" OPENING 48" LITEROCK FIRE ROCK FIREPLACE. PROVIDE FLU SENTINAL 48" LITEROCK FIRE ROCK FIREPLACE. PROVIDE FLU SENTINAL 1" FIREBRICK ICC RIS CHIMNEY ISTALLED PER MANUF. SPEC. 4' - 8" UNIT SIZE 2' - 4 1/2" UNIT SIZE APPROX. 1'-1" TALL BOULDER HEARTH OVER WOOD FRAMING AND STEEL BEAM RE: STRUCT APPROX. 1'-1" TALL BOULDER HEARTH OVER CONC. SLAB AND GRADE BEAM RE: STRUCT 6 7 8 1' - 0 1/4" 1 A7.2 1' - 1" 1' - 0" BOULDER HEARTH 10" TALL X 10" DEEP COLORADO BUFF CUT STONE MANTEL. PROVIDE KERF CUT ON BACK SIDE TO RECEIVE STEEL ANGLE PROVIDE STEEL ANGLE LAG-BOLTED @ EA. END INTO WOOD STRUCTURE. ICC RIS CHIMNEY INSTALLED PER MANUF. SPECIFICATION TYP. STONE VENEER ASSEMBLY PROVIDE WOOD BUILD UP @ ALL SIDE TO SUPPORT STONE VENEER 3" STONE SLAB CHIMNEY CAP *NO 2 5/8" RIGID INSULATION PANEL REQ'D ABOVE ROOF SIP PANEL GLULAM ROOF RAFTER RE: STRUCT FRAMING BEYOND RE: STRUCT. 12" 1" T.O. STONE @ 8336' - 9" T.O. CHIMNEY CAP @ 8340' - 9" 3' - 6" 3" 5 9/16" 7' - 1" 5 1/2" 5' - 9 1/16" 10" 3' - 3 5/8" 1' - 1" 4" 3' - 11 1/4" 4" SEE 1/A7.1 FOR FIRE BOX TYPE AND CLEARANCES MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8305' - 2" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8316' - 2 1/2" 6 7 8 1 A7.2 3' - 3 5/8" 10" 4" 3' - 11 1/4" 4" BOULDER HEARTH 10" TALL X 10" DEEP COLORADO BUFF CUT STONE MANTEL. PROVIDE KERF CUT ON BACK SIDE TO RECEIVE STEEL ANGLE PROVIDE STEEL ANGLE LAG-BOLTED @ EA. END INTO WOOD STRUCTURE. TYP. STONE VENEER ASSEMBLY PROVIDE WOOD BUILD UP @ ALL SIDE TO SUPPORT STONE VENEER *NO 2 5/8" RIGID INSULATION PANEL REQ'D ABOVE ROOF SIP PANEL FRAMING BEYOND RE: STRUCT. 3' - 2 7/16" 3 3/8" 3' - 3 5/8" 10" 4" 3' - 11 1/4" 4" 10" TALL X 10" DEEP COLORADO BUFF CUT STONE MANTEL. PROVIDE KERF CUT ON BACK SIDE TO RECEIVE STEEL ANGLE SEE 1/A7.1 FOR FIRE BOX MODEL AND CLEARANCES SEE 1/A7.1 FOR FIRE BOX MODEL AND CLEARANCES 6 7 8 A B A7.1 3 REUSE EXISTING TUB A8.0 4 1 A7.2 2 A7.2 3' - 11 1/2" CANTED WALL CANTED WALL CHIMNEYS FROM MAIN LEVEL FIREPLACES 5 1/2" 2' - 7 3/4" 5 1/2" 2' - 4 1/4" 5 1/2" 48" LITEROCK FIRE ROCK FIREPLACE. PROVIDE FLU SENTINAL Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 2/3/2015 3:37:09 PM A7.1 FIREPLACE SHEET AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET ADDENDUM 4 1-25-12 RESIZE NORTHEAST CHIMNEY WALL FOR NECESSARY BOILER FLU CLEARANCES 1/2" = 1'-0" 1 LIVING/OUTDOOR FIREPLACE MAIN LEVEL FLOOR PLAN 1/2" = 1'-0" 2 LIVING ROOM FIREPLACE ELEVTION 1/2" = 1'-0" 3 EXTERIOR FIREPLACES ELEVATION 4 LIVING ROOM FIREPLACE PERSPECTIVE 1/2" = 1'-0" 5 OUTDOOR FIREPLACE UPPER LEVEL FLOOR PLAN 6 MAIN LEVEL OUTDOOR FIREPLACE PERSPECTIVE No. Revision Date Revision Description 07/31/15