HomeMy WebLinkAboutB15-0026_A7.1_1438367880.pdfGENERAL NOTES:
1.) INSTALL GAS LOG SET AND BURNER PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A
COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY
PROPER INSTALLATION.
2.) INSTALL EXCEL MODEL RIS CHIMNEY PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A
COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY
PROPER INSTALLATION.
6 7 8
A
B
LIVING ROOM
SLIDING DOOR
Q
Q
C C
B
A7.1
2
A7.1
3
2
A5.3
1
A5.2
A8.0
4
1
A7.2
2
A7.2
2' - 6 1/2"
5 1/2" 2' - 7 3/4" 5 1/2" 2' - 4 1/4" 5 1/2"
CANTED WALL
CANTED WALL
9' - 3" 9' - 9"
3' - 11 1/4" OPENING
3' - 11 1/4" OPENING
48" LITEROCK FIRE ROCK
FIREPLACE. PROVIDE
FLU SENTINAL
48" LITEROCK FIRE ROCK
FIREPLACE. PROVIDE
FLU SENTINAL
1" FIREBRICK
ICC RIS CHIMNEY ISTALLED
PER MANUF. SPEC.
4' - 8" UNIT SIZE
2' - 4 1/2" UNIT SIZE
APPROX. 1'-1" TALL BOULDER
HEARTH OVER WOOD FRAMING AND
STEEL BEAM RE: STRUCT
APPROX. 1'-1" TALL BOULDER
HEARTH OVER CONC. SLAB AND
GRADE BEAM RE: STRUCT
6 7 8
1' - 0 1/4"
1
A7.2
1' - 1"
1' - 0"
BOULDER HEARTH
10" TALL X 10" DEEP COLORADO BUFF
CUT STONE MANTEL. PROVIDE KERF
CUT ON BACK SIDE TO RECEIVE STEEL
ANGLE
PROVIDE STEEL ANGLE LAG-BOLTED @
EA. END INTO WOOD STRUCTURE.
ICC RIS CHIMNEY
INSTALLED PER MANUF.
SPECIFICATION
TYP. STONE VENEER ASSEMBLY
PROVIDE WOOD BUILD UP @ ALL SIDE TO
SUPPORT STONE VENEER
3" STONE SLAB CHIMNEY CAP
*NO 2 5/8" RIGID INSULATION PANEL
REQ'D ABOVE ROOF SIP PANEL
GLULAM ROOF RAFTER RE: STRUCT
FRAMING BEYOND RE: STRUCT.
12"
1"
T.O. STONE @ 8336' - 9"
T.O. CHIMNEY CAP @ 8340' - 9"
3' - 6"
3" 5 9/16" 7' - 1" 5 1/2" 5' - 9 1/16"
10"
3' - 3 5/8" 1' - 1" 4"
3' - 11 1/4" 4"
SEE 1/A7.1 FOR FIRE BOX TYPE
AND CLEARANCES
MAIN LEVEL
FLOOR PLAN
FINISHED FLOOR
8305' - 2"
UPPER LEVEL
FLOOR PLAN
FINISHED FLOOR
8316' - 2 1/2"
6 7 8
1
A7.2 3' - 3 5/8" 10"
4" 3' - 11 1/4" 4"
BOULDER HEARTH
10" TALL X 10" DEEP COLORADO BUFF
CUT STONE MANTEL. PROVIDE KERF
CUT ON BACK SIDE TO RECEIVE STEEL
ANGLE
PROVIDE STEEL ANGLE LAG-BOLTED @
EA. END INTO WOOD STRUCTURE.
TYP. STONE VENEER ASSEMBLY
PROVIDE WOOD BUILD UP @ ALL SIDE TO
SUPPORT STONE VENEER
*NO 2 5/8" RIGID INSULATION PANEL
REQ'D ABOVE ROOF SIP PANEL
FRAMING BEYOND RE: STRUCT.
3' - 2 7/16" 3 3/8" 3' - 3 5/8" 10"
4" 3' - 11 1/4" 4"
10" TALL X 10" DEEP COLORADO BUFF
CUT STONE MANTEL. PROVIDE KERF
CUT ON BACK SIDE TO RECEIVE STEEL
ANGLE
SEE 1/A7.1 FOR FIRE BOX
MODEL AND CLEARANCES
SEE 1/A7.1 FOR FIRE BOX
MODEL AND CLEARANCES
6 7 8
A
B
A7.1
3
REUSE EXISTING TUB
A8.0
4
1
A7.2
2
A7.2
3' - 11 1/2"
CANTED WALL
CANTED WALL
CHIMNEYS FROM MAIN LEVEL FIREPLACES
5 1/2" 2' - 7 3/4" 5 1/2" 2' - 4 1/4" 5 1/2"
48" LITEROCK FIRE ROCK
FIREPLACE. PROVIDE
FLU SENTINAL
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
2/3/2015 3:37:09 PM
A7.1
FIREPLACE
SHEET
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
ADDENDUM 4 1-25-12
RESIZE NORTHEAST CHIMNEY WALL FOR
NECESSARY BOILER FLU CLEARANCES
1/2" = 1'-0"
1
LIVING/OUTDOOR FIREPLACE MAIN
LEVEL FLOOR PLAN
1/2" = 1'-0"
2 LIVING ROOM FIREPLACE ELEVTION
1/2" = 1'-0"
3 EXTERIOR FIREPLACES ELEVATION
4
LIVING ROOM FIREPLACE PERSPECTIVE
1/2" = 1'-0"
5
OUTDOOR FIREPLACE UPPER LEVEL
FLOOR PLAN
6
MAIN LEVEL OUTDOOR FIREPLACE
PERSPECTIVE
No. Revision Date
Revision
Description
07/31/15