Loading...
HomeMy WebLinkAboutB15-0026_A7.2_1438367880.pdfMAIN LEVEL FLOOR PLAN FINISHED FLOOR 8305' - 2" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8316' - 2 1/2" B 2 A7.2 8" 1' - 1" 10" TALL X 10" DEEP COLORADO BUFF CUT STONE MANTEL. PROVIDE KERF CUT ON BACK SIDE TO RECEIVE STEEL ANGLE MASON TO PROVIDE DESIGN BUILD ATTACHMENT SYSTEM W/ STEEL ANGLE LAG-BOLTED @ EA. END INTO WOOD STRUCTURE. ICC RIS CHIMNEY INSTALLED PER MANUF. SPECIFICATION WOOD HEADER RE: STRUCT FLAT FRAMED WOOD STRUCTURE 1" FIREBRICK TYP. STONE VENEER ASSEMBLY 48" LITEROCK FIRE ROCK FIREPLACE. PROVIDE FLU SENTINAL GRADE BEAM RE: STRUCT. T.O. CONC. @ 8305' - 1 1/4" T.O. CONC. LEDGE @ 8304' - 9 1/2" APPROX. 1'-1" TALL BOULDER HEARTH OVER WOOD FRAMING AND STEEL BEAM RE: STRUCT 8304' - 11 3/4" 4' - 7 1/4" 9' - 5" OPENING IN WALL TO ALLOW MAIN LEVEL EXTERIOR CHIMNEY TO CLEAR UPPER LEVEL FIREPLACE MAINTAIN CLEARANCES PER MANUF. SPECIFICATIONS 8 1/4" 2' - 9 1/2" T.O. PLY @ 8319' - 0" T.O. PLY @ 8318' - 7 1/4" 1/4" 1/4" 1/4" PROVIDE 2" MIN. CLEARANCE BTW FLU TO COMBUSTIBLES PROVIDE WOOD BUILD UP TO SUPPORT STONE VENEER. RE: STRUCT. FOR ATTACHMENT 3" STONE SLAB CHIMNEY CAP *NO 2 5/8" RIGID INSULATION PANEL REQ'D ABOVE ROOF SIP PANEL GLULAM ROOF RAFTER RE: STRUCT 3" 3' - 6" T.O. PLY @ 8336' - 9" T.O. CHIMNEY CAP @ 8340' - 9" 1' - 2" 8 1/4" TALL X 1' - 2" DEEP COLORADO BUFF CUT STONE HEARTH 10" TALL X 10" DEEP COLORADO BUFF CUT STONE MANTEL. PROVIDE KERF CUT ON BACK SIDE TO RECEIVE STEEL ANGLE 8318' - 5" 8320' - 2 1/2" MAIN LEVEL FLOOR PLAN FINISHED FLOOR 8305' - 2" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 8316' - 2 1/2" 7 8 1 A7.2 8" 2 1/2" 1' 1/2" SEE 1/A7.1 FOR FIRE BOX TYPE AND CLEARANCES TYP. STONE VENEER ASSEMBLY PROVIDE 2" MIN. CLEARANCE BTW FLU TO COMBUSTIBLES PROVIDE WOOD BUILD UP TO SUPPORT STONE VENEER. RE: STRUCT. FOR ATTACHMENT 3" STONE SLAB CHIMNEY CAP *NO 2 5/8" RIGID INSULATION PANEL REQ'D ABOVE ROOF SIP PANEL GLULAM ROOF RAFTER RE: STRUCT T.O. CHIMNEY CAP @ 8340' - 9" 3' - 6" CRICKET 4' - 9 1/4" 9' - 5" 8' - 1" 5' - 8 1/2" 15.000° 15.000° 2' - 0 5/8" 3' - 8 1/2" A7.2 3 3" STONE CHIMNEY CAP FILL 2X10 CAVITY WITH INSULATION TYPE X 5/8" DRYWALL CONT. TO B.O. STONE 2X8 JOISTS W/ TOPS CUT TO SLOPE PLY WOOD ABOVE @ 1/8" PER 1'-0" MAINTAIN 2" CLEARANCE TO COMBUSTIBLES 1/2" 12 4" TERMINATION CAP: MAINTAIN CLEARANCES PRESCRIBED BY CODE ABOVE ADJACENT CHIMNEY FLUES CHASE TOP COLLAR STORM COLLAR SET IN SEALANT OVER FLASHING PROVIDE ELECTRONIC FLUE DAMPER AT INTERIOR FIREPLACE CHIMNEY; PER MANUF SPECIFICATION 3" STONE CHIMNEY CAP SET IN BED OF MORTAR OVER FLASHING CAP 1/2" 4" 2" 2" 1/2" 4X4 TUBE STEEL POST CANTED AT 1/2":12 WELDED TO 1/2" X 6" X 6" STEEL PLATE AT TOP AND 1/2" X 12" X 12 " BOTTOM SET IN A BED OF SEALANT OVER FLASHING, FASTENED WITH (4) EXPANSION BOLTS INTO STONE ABOVE AND BELOW. WRAP IN STONE VENEER LAP CONT. W.P. MEMBRANE OVER T.O WALL & PLYWOOD CONT. FLASHING PAN UNDER STONE CONTINUES UP WALLS 8" MIN. W/ STORM COLLAR THAT TURNS UP @ FLUE 5" MIN Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 2/3/2015 3:37:13 PM A7.2 FIREPLACE SHEET AG HB FLEEGER RESIDENCE 02/03/2015 2950 BOOTH CREEK DR, VAIL VILLAGE FILING 11, BLOCK 3, LOT 2 BUILDING PERMIT SET 1/2" = 1'-0" 1 FIREPLACE EAST-WEST SECTION1 1/2" = 1'-0" 2 FIREPLACE NORTH-SOUTH SECTION1 1 1/2" = 1'-0" 3 CHIMNEY CAP DETAIL No. Revision Date Revision Description 07/31/15