HomeMy WebLinkAboutB15-0026_A7.2_1438367880.pdfMAIN LEVEL
FLOOR PLAN
FINISHED FLOOR
8305' - 2"
UPPER LEVEL
FLOOR PLAN
FINISHED FLOOR
8316' - 2 1/2"
B
2
A7.2
8"
1' - 1"
10" TALL X 10" DEEP COLORADO BUFF
CUT STONE MANTEL. PROVIDE KERF
CUT ON BACK SIDE TO RECEIVE STEEL
ANGLE
MASON TO PROVIDE DESIGN BUILD
ATTACHMENT SYSTEM W/ STEEL
ANGLE LAG-BOLTED @ EA. END INTO
WOOD STRUCTURE.
ICC RIS CHIMNEY
INSTALLED PER MANUF.
SPECIFICATION
WOOD HEADER RE: STRUCT
FLAT FRAMED WOOD STRUCTURE
1" FIREBRICK
TYP. STONE VENEER ASSEMBLY
48" LITEROCK FIRE ROCK
FIREPLACE. PROVIDE
FLU SENTINAL
GRADE BEAM RE: STRUCT.
T.O. CONC. @ 8305' - 1 1/4"
T.O. CONC. LEDGE @ 8304' - 9 1/2"
APPROX. 1'-1" TALL BOULDER
HEARTH OVER WOOD FRAMING AND
STEEL BEAM RE: STRUCT
8304' - 11 3/4"
4' - 7 1/4"
9' - 5" OPENING IN WALL TO ALLOW MAIN LEVEL
EXTERIOR CHIMNEY TO CLEAR UPPER LEVEL
FIREPLACE MAINTAIN CLEARANCES PER MANUF.
SPECIFICATIONS
8 1/4"
2' - 9 1/2" T.O. PLY @ 8319' - 0"
T.O. PLY @ 8318' - 7 1/4"
1/4"
1/4"
1/4"
PROVIDE 2" MIN. CLEARANCE
BTW FLU TO COMBUSTIBLES
PROVIDE WOOD BUILD UP TO SUPPORT
STONE VENEER. RE: STRUCT. FOR
ATTACHMENT
3" STONE SLAB CHIMNEY CAP
*NO 2 5/8" RIGID INSULATION PANEL
REQ'D ABOVE ROOF SIP PANEL
GLULAM ROOF RAFTER RE: STRUCT
3"
3' - 6" T.O. PLY @ 8336' - 9"
T.O. CHIMNEY CAP @ 8340' - 9"
1' - 2"
8 1/4" TALL X 1' - 2" DEEP COLORADO
BUFF CUT STONE HEARTH
10" TALL X 10" DEEP COLORADO BUFF
CUT STONE MANTEL. PROVIDE KERF
CUT ON BACK SIDE TO RECEIVE STEEL
ANGLE
8318' - 5"
8320' - 2 1/2"
MAIN LEVEL
FLOOR PLAN
FINISHED FLOOR
8305' - 2"
UPPER LEVEL
FLOOR PLAN
FINISHED FLOOR
8316' - 2 1/2"
7 8
1
A7.2
8"
2 1/2"
1'
1/2"
SEE 1/A7.1 FOR FIRE BOX TYPE
AND CLEARANCES
TYP. STONE VENEER ASSEMBLY
PROVIDE 2" MIN. CLEARANCE
BTW FLU TO COMBUSTIBLES
PROVIDE WOOD BUILD UP TO SUPPORT
STONE VENEER. RE: STRUCT. FOR
ATTACHMENT
3" STONE SLAB CHIMNEY CAP
*NO 2 5/8" RIGID INSULATION PANEL
REQ'D ABOVE ROOF SIP PANEL
GLULAM ROOF RAFTER RE: STRUCT
T.O. CHIMNEY CAP @ 8340' - 9"
3' - 6"
CRICKET
4' - 9 1/4"
9' - 5" 8' - 1" 5' - 8 1/2"
15.000°
15.000°
2' - 0 5/8" 3' - 8 1/2"
A7.2
3
3" STONE CHIMNEY CAP
FILL 2X10 CAVITY
WITH INSULATION
TYPE X 5/8" DRYWALL
CONT. TO B.O. STONE
2X8 JOISTS W/ TOPS CUT TO
SLOPE PLY WOOD ABOVE @
1/8" PER 1'-0" MAINTAIN 2"
CLEARANCE TO COMBUSTIBLES
1/2"
12
4"
TERMINATION CAP: MAINTAIN
CLEARANCES PRESCRIBED BY
CODE ABOVE ADJACENT CHIMNEY
FLUES
CHASE TOP COLLAR
STORM COLLAR SET IN SEALANT OVER FLASHING
PROVIDE ELECTRONIC FLUE
DAMPER AT INTERIOR FIREPLACE
CHIMNEY; PER MANUF
SPECIFICATION
3" STONE CHIMNEY CAP
SET IN BED OF MORTAR
OVER FLASHING CAP
1/2"
4"
2" 2"
1/2"
4X4 TUBE STEEL POST CANTED AT 1/2":12
WELDED TO 1/2" X 6" X 6" STEEL PLATE AT
TOP AND 1/2" X 12" X 12 " BOTTOM SET IN
A BED OF SEALANT OVER FLASHING,
FASTENED WITH (4) EXPANSION BOLTS
INTO STONE ABOVE AND BELOW. WRAP IN
STONE VENEER
LAP CONT. W.P.
MEMBRANE OVER T.O
WALL & PLYWOOD
CONT. FLASHING PAN
UNDER STONE CONTINUES
UP WALLS 8" MIN. W/
STORM COLLAR THAT
TURNS UP @ FLUE 5" MIN
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
2/3/2015 3:37:13 PM
A7.2
FIREPLACE
SHEET
AG
HB
FLEEGER RESIDENCE
02/03/2015
2950 BOOTH CREEK DR, VAIL VILLAGE FILING
11, BLOCK 3, LOT 2
BUILDING PERMIT SET
1/2" = 1'-0"
1
FIREPLACE EAST-WEST SECTION1
1/2" = 1'-0"
2 FIREPLACE NORTH-SOUTH SECTION1
1 1/2" = 1'-0"
3 CHIMNEY CAP DETAIL
No. Revision Date
Revision
Description
07/31/15