HomeMy WebLinkAboutB15-0026_PL2.4_1476902040.pdfMIN. 1'-6"
MIN. 5'-0"
1" CONDUIT TO
ELECTRICAL PANEL
BY E.C; LOCATION
T.B.D.
1" CONDUIT BY E.C.
120 V. 500 WATT LIGHT AND
NICHE PROVIDED AND INSTALLED
BY P.C. PER SPECS
GROUND CLAMP AND #8 AWG
GROUNDING WIRE TO LIGHT NICHE
BY E.C.
RE-LAMP POSITION;
PROVIDE ENOUGH
CORD
J-BOX PROVIDED AND
INSTALLED BY E.C. 18"
MIN.
POOL LIGHT SECTION 18"
MIN.
1" CONDUIT TO
ELECTRICAL PANEL
BY E.C; LOCATION
T.B.D.
1" CONDUIT BY E.C.
120 V. 100 WATT LIGHT AND
NICHE PROVIDED AND INSTALLED
BY P.C. PER SPECS
GROUND CLAMP AND #8 AWG
GROUNDING WIRE TO LIGHT NICHE
BY E.C.
RE-LAMP POSITION;
PROVIDE ENOUGH
CORD
J-BOX PROVIDED AND INSTALLED
BY E.C.
SPA LIGHT SECTION
MIN. 5'-0"
MIN. 1'-6"
12" STONE SUPPORT BRACKETS
WITH ADJUSTABLE LEG BRACKETS
NOTE:
AUTOMATIC COVER-
COVERSTAR SAFETY COVER
MEETS UL AND ASTM F 1346-91
AUTO COVER BOX DRAIN
G.C. TO DRAIN TO DAYLIGHT
COVER
LEADING
EDGE
UN-GROUTED OPENING TO ALLOW
FOR REMOVAL OF STONE COPING
REMOVABLE COPING SET IN
PANS, TO ACCESS AUTO COVER
MECHANISM, BY G.C.
1'-21
2" 6"
1'-81
2" 6"
6"
6"
12" STONE SUPPORT BRACKETS
WITH ADJUSTABLE LEG BRACKETS
NOTE:
AUTOMATIC COVER-
COVERSTAR SAFETY COVER
MEETS UL AND ASTM F 1346-91
AUTO COVER BOX DRAIN
G.C. TO DRAIN TO DAYLIGHT
COVER
LEADING
EDGE
UN-GROUTED OPENING TO ALLOW
FOR REMOVAL OF STONE COPING
REMOVABLE COPING SET IN
PANS, TO ACCESS AUTO COVER
MECHANISM, BY G.C.
10" 6"
AUTO COVER TRACK
REMOVABLE LID TO ACCESS
SKIMMER BASKET
EQUALIZER LINE
REMOVABLE COPING SET IN
PANS, TO ACCESS AUTO COVER
MECHANISM, BY G.C.
AUTO FILL SENSOR
AUTO COVER BOX
SPA JET AIR LOOP CONCEALED
IN AUTO COVER BOX
SHOTCRETE AROUND AUTO
COVER MECHANISM, REFER TO
PLANS
H
M
L
CONTINUE TO AIR LINE
TERMINATE ABOVE WATER LEVEL
HYDRO THERAPY JETS
H:HIGH
M:MIDDLE
L:LOW BENCH
C:CALF
C
CALF JET
H
M
L
HYDROTHERAPY JET
RETURN LINES TIED TO
MAIN SUCTION DRAINS,
REFER
TO PLAN
COPING REFER TO PLAN
AUTO COVER TRACK
WATER INLETS,
REFER TO PLAN
MIN. 18"
ABOVE
WATER
LEVEL
1" LOW VOLTAGE LIGHT
CONDUIT TO ELECTRICAL
PANEL, BY E.C. J-BOX PROVIDED AND INSTALLED
BY E.C. FAUX PAINT TO MATCH
SURROUNDING MATERIAL, BY G.C.
(MUST BE AT LEAST 5"-0" FROM
WATER)
48" A.F.F.
(MIN.18"
ABOVE
WATER
LEVEL)
WALL AND FINISH MATERIAL BY
G.C.
1" LOW VOLTAGE CONDUIT TO
ELECTRICAL BY E.C.
OPTIONAL WALL
MOUNTED AUTO COVER
KEY SWITCH
J-BOX PROVIDED AND INSTALLED BY E.C.
FAUX PAINT TO MATCH SURROUNDING
MATERIAL, BY G.C. (MUST BE AT LEAST
5"-0" FROM WATER)
1'-0"
AUTO COVER TRACK 1 1
8" H.
MUD SET UNDER STONE/TILE
COPING STONE/TILE PER LANDSCAPE
ARCHITECTS DRAWINGS
VERIFY COPING SIZE, BY G.C.
SLOPE COPING AWAY
FROM POOL/SPA
PL2.4
DETAILS
SCALE: 1"=1'-0"
SWIMMING POOL LIGHT
1
PROJECT:
DRAWING:
FLEEGER
RESIDENCE
2950
BOOTH
CREEK
DRIVE
VAIL,
COLORADO
DATE ISSUE
3-23-16 DD
5-6-16 CD
5-18-16 CD
6-13-16 CD
SCAPES
SCALE: 1"=1'-0"
SPA
LIGHT
2
SCALE: 1"=1'-0"
SWIMMING POOL AUTO COVER
3
SCALE: 1"=1'-0"
SPA AUTO COVER
4
SCALE: 1"=1'-0"
SKIMMER SECTION
5
SCALE: 1"=1'-0"
AUTO FILL AND JET AIR LOOP
6
SCALE: 1"=1'-0"
HYDROTHERAPY JET AIR LINE
7
SCALE: 1"=1'-0"
HYDROTHERAPY JET RETURN LINE
8
SCALE: 1"=1'-0"
POOL/SPA COVER KEY SWITCH
9
SCALE: 1"=1'-0"
J-BOX, SITE LOCATED
10
SCALE: 1"=1'-0"
TYPICAL COPING
11
10/19/16