Loading...
HomeMy WebLinkAboutB15-0026_S-621_1438367880.pdf5 1/8x18 GLULAM BLOCKING BETWEEN RAFTERS W/ (4) 3/4"Ø LAGS EACH END W/ 4" PENETRATION (20) 9" LOG HOG @ 3" OC TO GLULAM RAFTERS CAP PL1/2x5 1/2x1'-5" W/ (4) 3/4"Ø LAGS W/ 4" PENETRATION INTO BLOCKING 3/16 S-500 16 FOR ADDITIONAL INFORMATION SEE S-620 5 S-620 12 (2) 11 7/8" LVL LEDGER W/ (3) ROWS #24 SCREWS @ 8" O.C. HANGER SEE S-601 3 C12x20.7 W/ 1/2"Ø LAGS W/ 3" PEN @ EA STUD 3x SOLID BLOCKING (3) 11 7/8" LVL LEDGER W/ (3) ROWS #24 SCREWS @ 8" O.C. BLOCKING @ 48" OC C12x20.7 W/ 1/2"Ø LAGS W/ 3" PEN @ EA STUD 3x SOLID BLOCKING (2) 11 7/8" LVL LEDGER W/ (3) ROWS #24 SCREWS @ 8" O.C. HANGER SEE S-601 3 BIRDSMOUTH RAFTER UP TO 1 1/2" MAX CURVED GLULAM RAFTER 2x SPLINE @ OVERFRAMED ROOF 2x OVERFRAMING @ 16" OC SIMPSON HGA10KT @ EA RAFTER FULL HEIGHT 2x BLOCKING BLOCKING @ 48" OC LVL LEDGER W/ (3) ROWS 10d NAILS @ 16" OC FOR ADDITIONAL INFORMATION SEE S-621 5 S-620 4 . 4" 3/8" STIFF PL ES CENTERED UNDER W21 WEB (2) 3/4"Ø BOLTS @ 3 1/2" GA 3/8" STIFF PL ES CENTERED OVER W10 WEB 1" 3" 1 1/2" . KNIFE PL 3/8x5 1/2x1'-0" W/ (4) 3/4"Ø BOLTS 3/16 KNIFE PL1/2x4x0'-10" W/ (2) 3/4"Ø BOLTS 2"2" 1 1/2"3"5 1/2" S-620 4 SHEET TITLE: SHEET NUMBER: © MARTIN/MARTIN 2013 MM JOB #: PRINCIPAL: EOR: PROJECT MANAGER: DESIGNERS: DATE PRINTED: Martin/Martin, Inc. considers that design data is only in its final form on plotted drawings with original signatures and professional certification being visibly present on the drawings. Data supplied via computer generated format does not contain this approval or certification. The receiver of electronically transmitted drawings is responsible for verifying the information contained within the electronic data against the recorded or approved documents. The use of electronically transmitted drawings is considered to be at your own risk. Martin/Martin, Inc. assumes no responsibility for any claims or damages resulting from your use of this information. Electronic information is provided for the convenience of the recipient only. The recipient of this file agrees that the information may not be transferred to any other party. PROJECT NO: DATE: REVISIONS NO. ISSUE DATE PERMIT 6/14/13 PROGRESS SET 10/27/14 PERMIT SET 02/03/15 2/5/2015 10:04:36 PM C:\Proj\12.0362-Fleeger-RS14_seanm.rvt S-621 Fleeger Residence ROOF DETAILS 2950 Booth Creek Drive, Vail, CO SJM SJM PD 12.0362.S.01 12.0362.S.01 09/20/2013 1 1/2" = 1'-0" 12 COL @ ENTRY ROOF 1 1/2" = 1'-0" 1 RAFTERS BEARING AT PARAPET 1 1/2" = 1'-0" 2 PARALLEL RAFTERS @ PARAPET 1 1/2" = 1'-0" 3 PARALLEL RAFTERS @ STONE PARAPET 1 1/2" = 1'-0" 5 HIGH CURVED ROOF OVERFRAMING 1 1/2" = 1'-0" 6 HIGH SLOPED ROOF OVERFRAMING 1 1/2" = 1'-0" 8 LOW ROOF @ OVERHANG 1 1/2" = 1'-0" 9 BEAM CONNECTION 1 1/2" = 1'-0" 7 LOW ROOF @ STEEL BEAM 1 1/2" = 1'-0" 10 EAVE @ BRACKET 2/3/2015 07/31/15