Loading...
HomeMy WebLinkAboutB15-0037_A0_14_1425423000.pdf NOTES: r r n APPROVALS . .0, 1 . THE SCOPE OF WORK SHALL DICTATE THE EQUIPMENT TO BE INSTALLED. EQUIPMENT RRH #1 &4 RRH #2&5 RRH #3&6 RRH #7 RRH #8 RRH #9kJ, . 4111r * SHALL BE EQUAL TO OR BETTER THAN REFERRED VENDORS. 2. CONTRACTOR SHALL VERIFY THAT THE SITE PANEL IS AS SHOWN. IF THE SITE PANEL IS 0 e e Xi?..\ e e 0 e e NOT AS SHOWN, CONTRACTOR SHALL NOTIFY THE ENGINEER AS SOON AS PRACTICABLE. ojiacol,zill 3. CONTRACTOR SHALL PROVIDE ALL CONDUITS, CIRCUITS REQUIRED OF A COMPLETED SYSTEM AND SHALL BE IN COMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. EXISTING - \ \ \ \ \ \ 03/03/15 MOUNT r PROPOSED MOUNT 4. CONTRACTOR SHALL BE RESPONSIBLE FOR AS—BUILT PANEL SCHEDULE AND SITE LOCATION r r r r LOCATION DRAWINGS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING OF THE AC AND DC POWER SUPPLY SYSTEMS AND FOR VERIFYING THAT THE PROPOSED TELECOM EQUIPMENT CAN WORK ) ) J ) PROPERLY IN CONJUNCTION WITH THE EXISTING ELECTRICAL SYSTEM. THE TEST RESULTS IN 4 _ ACTUAL LOADS SHALL BE DOCUMENTED USING THE FORMS PROVIDED IN AT&T's DOCUMENT ��� r r TITLED "SITE SURVEY A5." ALL FORMS SHALL BE COMPLETED IN THEIR ENTIRETY. THE A5 ROUTE TO ROUTE TO FORM SHALL BE PRESENTED TO THE CONSTRUCTION MANAGER WELL IN ADVANCE OF THE NEAREST THE NEAREST GROUNDING GROUNDING PLACEMENT OF NEW TELECOM EQUIPMENT. BAR (TYP) BAR (TYP) + — + — + — + — 24VDC HI 1 1 1 1 I H --1 1 I I BATTERY BANK L i a + — + — + — + — JUMPER J SCOPE OF WORK + - + - + - + - SO@ 0 H1111 1 --� 1 1 I 0007 0 0 000 1 . INSTALL (3) NEW RRHs AND SURGE PROTECTOR. INSTALL LTE 3C RADIO CARDS. EXISTING RAYCAP NEW RAYCAP SURGE 2. EXISTING GE "INFINITY M" +24V DC POWER PLANT HAS (10) 100A RECTIFIERS 1 (TYP)CABLE SHIELDS SURGE PROTECTION #1 PROTECTION #2 AND (5) 30A DC—DC CONVERTER MODULES. FIVE RECTIFIERS AND TWO ✓ J DC6-48-60-18-8F DC6-48-60-0-8F CONVERTER MODULES ARE ACTIVE. ENERGIZE (4) EXISTING RECTIFIERS AND (2) J ROUTE TO II :III EII: II: EXISTING DC CONVERTER MODULES. NINE ENERGIZED RECTIFIERS AND (4) MASTER ENERGIZED DC CONVERTER MODULES ARE SUFFICIENT FOR THE NEW LTE °]]7 EXISTING LINEAGE POWER GROUNDING ELECTRICAL LOADS AND TO ALLOW FOR FUTURE EXPANSION. • • C 1 1 PLANT 3. INSTALL THE FOLLOWING DC CIRCUIT BREAKERS: (1 ) 20A/1P BREAKER r -- --- #407998186 FOR EACH INDOOR LTE BBU AND (1 ) 15A/1P BREAKER #407998160 PER RRH. INSTALL ADDITIONAL DC BREAKERS FOR ANCILLARY 1 24.--- 0 0 0 0 0 0 0 0 0 0 0 0 EQUIPMENT AS NECESSARY. ° 0 0 0 0 0 0 0 0 0 0 3 4 00•O l`"*. .,, 4. SITE HAS (10) STRINGS (20 CELLS) OF EXISTING MARATHON M12V155FT 5 6 1J BATTERIES, WHICH ARE INSUFFICIENT. INSTALL (1 ) NEW SEISMIC—RATED BATTERY • ® 0 1 r RACK WITH (4) STRINGS (8 CELLS) OF NEW MARATHON M12V155FT BATTERIES TO 7 0 0 8 o �� 1� £ r -- DC CIFCLI— SCHEDULE PROVIDE 4.0 HOURS OF BATTERY BACKUP. 90 0 10 �� (E) FIBER OPTIC FROM TO CONFIGURATION 5. TWO 4—TON HVAC UNITS ARE RECOMMENDED. THE TONNAGE RATING OF THE TWO 0441— 111 0 1 I CABLE EXISTING HVAC UNITS CANNOT BE CONFIRMED FROM EXISTING DOCUMENTATION I 11 , n 12 (1) 2—#10 ONE RED BUT HAVE BEEN ASSUMED AS THREE—TON UNITS. PANEL. o �. �o o I O 1A -24VDC CIRCUIT LTE BASE BAND UNIT I ONE GREY 13 7--• 14 •••• (E) LTE BASE BAND UNIT 6 RAYCAP SURGE (1) 2—#8 GREY CLASS B 15 16 ■ 0 ED 2A —24VDC CIRCUIT PROTECTION (TELCO FLEX) III OR IV O 0-0 DC6-48-60—RM TELCO FLEX AC POWER PANEL No. 1 (PROPOSED) ED RAYCAP SURGE (1) 2—#8 GREY CLASS B 17 18 120/240 VOLTS, 1-PHASE, 3-WIRE, 200A n n ED 3A —24VDC CIRCUIT PROTECTION (TELCO FLEX) III OR IV O 0--. .--° 0 J r DC6-48-60—RM TELCO FLEX MAIN BREAKER RATING (A) : 200 SYSTEM VOLTAGE (V) : 240 19 20 �� J EXISTING RAYCAP SURGE (1) 2—#8 GREY CLASS B DESCRIPTION VA c/nc BKR POSN L1 L2 POSN BKR c/nc VA DESCRIPTION O ° ° 0 ED 4A —24VDC CIRCUIT PROTECTION (TELCO FLEX) III OR IV 2611 nc 1 5222 2 nc 2611 GROUNDING BAR DC6-48-60—RM TELCO FLEX HVAC #1 2611 nc 30 3 5222 4 30 nc 2611 HVAC#2 21 0 0 22 0 EXISTING RAYCAP RAYCAP SURGE (1) 6—#8 LIGHTS 840 nc 20 5 1200 6 20 nc 360 RECEPTACLES 3 nCD2 24 EXISTING RAYCAP J J SURGE PROTECTION DC6-48-60—RM PROTECTION DC6-48-60-18-8F THHN/THWN/VW-1 TYPE TC—ER DC CABLE HALON PANEL 200 c 20 7 560 8 20 nc 360 RECEPTACLES SURGE PROTECTION 1633 nc 9 1993 10 20 nc 360 RECEPTACLES B NEW RAYCAP SURGE RAYCAP SURGE (1) 6—#8 RECTIFIER#1 20 DC6-48-60—RM 1633 nc 11 1993 12 20 nc 360 RECEPTACLES 25 n 26 CD PROTECTION PROTECTION THHN/THWN/VW-1 TYPE ■ DC6-48-60—RM DC6-48-60-18-8F TC—ER DC CABLE1633 nc 13 3266 14 nc 1633 RECTIFIER#2 20 20 RECTIFIER#7* 27 n , 28 r RAYCAP SURGE RRH REMOTE RADIO (1) 2—#12 1633 nc 15 3266 16 nc 1633 ° �. �° 0 UPGRADE EXISTING RAYCAP ©©O EXISTING ED PROTECTION HEAD #1 THHN/THWN/VW-1 RECTIFIER#3 1633 nc 20 17 3266 18 20 nc 1633 RECTIFIER#8* 29 n n 30 SURGE SUPPRESSOR TO GROUNDING DC6-48-60-18-8F TYPE TC—ER DC CABLE 1633 nc 19 3266 20 nc 1633 ACCOMODATE NEW RRH BAR RAYCAP SURGE RRH REMOTE RADIO (1) 2—#12 1633 nc 21 3266 22 nc 1633 O PROTECTION THHN THWN VW-1 RECTIFIER #4 20 20 RECTIFIER#9* 31 32 UNITS \ p J ).J HEAD #2 / / 1633 nc 23 3266 24 nc 1633 n n DC6-48-60-18-8F TYPE TC—ER DC CABLE 25 1633 26 33 n 34 0 RAYCAP SURGE RRH REMOTE RADIO THHN1)THWN 1VW-1 RECTIFIER #5 nc 20 20 SPARE (OFF) 1633 3 nc 27 1633 28 DC6-48-60-18-8F HEAD #3 TYPE TC ER DC CABLE 1633 nc 29 1633 30 35 36 RAYCAP SURGE (1) 2—#12RECTIFIER#6* 2031 32 20 SPARE (OFF) 0 07 RRH REMOTE RADIO BLANK 1633 nc 33 0 1633 34 BLANK 0 PROTECTION HEAD #4 THHN/THWN/VW-1 37 n 38 LOCATED WITHIN DC6-48-60-18-8F TYPE TC—ER DC CABLE BLANK 35 0 36 BLANK EXISTING LTE RACK RAYCAP SURGERRH REMOTE RADIO (1) 2—#12 BLANK 37 0 38 BLANK 3940 11 PROTECTION HEAD #5 THHN/THWN/VW-1 BLANK 39 0 40 BLANK �. 0 DC6-48-60-18-8F _ TYPE TC—ER DC CABLE BLANK 41 0 42 BLANK 41 42 p JJJ RAYCAP SURGE RRH REMOTE RADIO (1) 2—#12 PHASE TOTALS (VA): 21479 20839 n n 12 PROTECTION HEAD 6 THHN/THWN/VW-1 ° °--• •--° 0 # CURRENT PER PHASE (A): 179 174 Amperes/phase cannot exceed main breaker rating DC6-48-60-18-8F TYPE TC—ER DC CABLE RAYCAP SURGE PROTECTION (1) 2—#12 PANEL TOTAL (VA): 42318 Legend: c = continuous, nc = non-continuous ••• 0 RRH REMOTE RADIO PANEL CAPACITY (kVA): 48.0 CONNECTED LOAD (kVA): 42.3 HEAD #7 THHN/THWN/VW-1 PANEL LOADING (100% non-cont. load (kVA): 42.1 1 DC6-48-60-18-8F TYPE TC—ER DC CABLE ) ( ) RAYCAP SURGE RRH REMOTE RADIO (1) 2—#12 PANEL LOADING (125% continuous load) (kVA): 0.3 14 PROTECTION HEAD #8 THHN/THWN/VW-1 PANEL LOADING (TOTAL) (kVA): 42.4 L .1 DC6-48-60-18-8F TYPE TC—ER DC CABLE SPARE CAPACITY (kVA): 5.6 TO EXISTING RAYCAP SURGE RRH REMOTE RADIO HEAD #9 (1) 2—#12 NOTES: MASTER GROUNDING 1 5 PROTECTION THHN/THWN/VW-1 1. CHANGES AND NEW CIRCUITS ARE INDICATED IN BOLD FONT WITH AN ASTERISK (*). DC6-48-60-18-8F TYPE TC—ER DC CABLE 2. ENERGIZE (4) EXISTING 100A GE RECTIFIERS, CONNECT TO EXISTING 20A/2P CIRCUIT BREAKERS. /� BAR /� 3. UPDATE AC PANEL SCHEDULE. ELECTRICAL DC ONE—LINE DIAGRAM 1 DESIGN CONSULTANT ..— AT&T MOBILITY • aRED SANDSTONE ,_ ' ' . 1 ' -sTec -ante grat eda ° ° E2 DESIGN SERVICES GROUP Network Solutions C O L04025 ' t - R J _ 37860 ° . 1 ELECTRICAL ONE-LINE DIAGRAM 2200 E.WILLIAMS FIELD RD, SUITE 200 545 N. FRONTAGE RD. AT&T MOBILITY 0 02/03/15 FINAL CONSTRUCTION DRAWINGS 1M CP MA =. -® o a Or if GILBERT, ARIZONA 85295 7025 S. REVERE PKWY 188 INVERNESS DRIVE WEST, SUITE 400 " P°°°° °°�4y '1 VAI L, CO 81657 N0. DATE REVISIONS BY CHK APP'D . °� °°° ° ° e FA NUMBER DRAWING NUMBER REV OFFICE: (602)218-8820-FAX(602)218-8820 SUITE 100 ENGLEWOOD, CO 80112 :,,`\7,9/°°°°°° °��',' \1`' ® �"�,,� �� 10093722 COL04025— E2 0 CENTENNIAL, CO 80112 SCALE: AS SHOWN DESIGNED BY: RJK DRAWN BY: RJK �,� 6 5 4 3 2 22 x 34 "D" SIZE