HomeMy WebLinkAboutB15-0037_A0_7_1425423000.pdf 411,1
OF 1,4
APPROVALS 4,: °,110111V....
ki iilltiiri
z id
NI r77
C3
DC2 RRH 4
Cl gol
DC6—RM DC2 RRH
— DC2 RRH 03/03/15
D1 �D3�
FIGURE 1 — TRUNK CABLE TO JUNCTION BOX
MAXIMUM CABLE LENGTHS FOR FIGURE 1 P1000 UNISTRUT CHANNEL _ ..-12.2"
OR EQUIVALENT (2 TYP) ALCATEL—LUCENT RRH
ALCATEL—LUCENT (ALU) (NP) /
END CAPS
LENGTH D 1 (FT) II—I n n n n n (NP) I
acddddddd> dddddd ddddddd�ddddss �dddddddd>�f ddedd 3.50"
Cl SIZE C2 SIZE 75 100 125 150 175 200 250
° Aq `*
8AWG 213 188 163 138 113 88 38 cDOME VER
N - 1 \// SECURING BAND
8AWG 10AWG w N 135 119 103 87 71 56 24 cit E
i —AIR VALVE
_10 o ;
ro
12AWG 85 75 65 55 45 35 15 o a cair
, -
,
N , '
/1 o 0 0 , o
RRH 1 i ____
Cl DC2 C2 RRH �b 5 dR Db, sdU
-or
DC6—RM Cl DOME C2 ] I RRH DC6—RM DC2 RRH ��� ��� -EriziTOP VIEW
1
4„
RRH DC2 RRH ANCHOR/FASTENER (MIN.) RAYCAP DC6 9.25 — C
(SEE NOTE 3) CLEARANCE OVER VOLTAGE
D 1 _ D2 D 1 D2 PROTECTOR 9.00"
ELEVATIO \ DOME COVER
FIGURE 2 — TRUNK CABLE TO DC6 (DOME) FIGURE 3 — DIRECT CABLE TO DC2 A �
MAXIMUM CABLE LENGTHS FOR FIGURES 2 AND 3 \ OTES :
, ,
1 . ALCATEL—LUCENT (ALU) VIA AT&T SUPPLIES THE RRH. SUBCONTRACTOR SHALL SUPPLY ALL '
OTHER MATERIALS AND INSTALL ALL MOUNTING HARDWARE. ALU INSTALLS RRH AND MAKES
CABLE TERMINATIONS. ,
ALU LENGTH D1 /D2 (FT) 2. A SUPPORT FOR A SINGLE RRH SHALL HAVE A MINIMUM OF TWO ANCHORS/FASTENERS FOR DOME COVER
EACH UNISTRUT CHANNEL.
SECURING BAND
CABLE 8 AWG 10 AWG 12 AWG
3. INSTALL ANCHORS/FASTENERS A MAXIMUM OF 2 —0 ON CENTERS. RAYCAP SUPPLIED ,
Cl 288 186 137 • WOOD STUDS — 1 /4"0 LAG BOLT W/ 1 " EMBEDMENT IN WOOD SECURING BAND FOR
/ ATTACHING DOME 6
• CONCRETE — 1 /4"0 HILTI KWIK BOLT III W/ 1 - 1 /2" EMBEDMENT OR EQUIVALENT COVER TO DC6 OVER ' N
C2 16 16 16 • THROUGH BOLT — 1 /4"0 A36/A307 THREADED ROD W/ NUTS AND WASHERS VOLTAGE PROTECTOR — — —I�
ANCHORS AND UNISTRUT CHANNEL SHALL HAVE HOT—DIPPED GALVANIZED FINISH. 1 - - S
E — IT — 7
4. MOUNT RRH TO UNISTRUT WITH 3/8"0 UNISTRUT BOLTING HARDWARE AND SPRING NUTS.
NOTES: TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. CLIP LUGS FOR ATTACHING
11,
DEVICE TO BASE ASSEMBLY B
1 . CABLES LENGTHS ARE APPLICABLE FOR 700MHz, 1900MHz & AWS FREQUENCIES 2x40W AND 2x60W ALU RRH
MODELS AND ERICSSON MODEL RRUS-11 . ALCATEL— LUCE\T 9442iilani — OVAL CABLE INGRESS PORT
2. NOMINAL SYSTEM VOLTAGE IS —48V DC, SUPPLIED FROM A 48V BATTERY. NORMAL OPERATING VOLTAGE IS —52V. EMOTE �A3 0 HEAD ( H ) WALL V O U \T sewNMI
3. CABLE LENGTHS BASED ON ROSENBERGER AND COMMSCOPE CABLES. 9.56" CABLE EGRESS
PORTS (TYP)
"Cr (NOTE 1)
10.38" SIDE VIEW
NOTES: AO. OVAL FIBER CABLE INGRESS AND
ALARM CABLE EGRESS PORT
1 . REMOVE CABLE SEALING GLAND AND ' CABLE EGRESS PORT
INSTALL M32x1 .5 METRIC—TO-1 " J `o _/ '• (TYP 6)
NPT ADAPTER (COPPER \ \ �. rk �. \
CROUSE—HINES P/N CAP 740 994 •) ��i 1 ��i FIBER SIDE
OR EQUIVALENT MFR) WHEN 00 POWER SIDE
CONNECTING CONDUIT TO OVP.
OVAL POWER CABLE INGRESS PORT
0 0
DOME COVER
CLIP LUGS FOR ATTACHING oSECURING BAND
DEVICE TO BASE ASSEMBLY
(TYP 4) BOTTOM VIEW
A
LTE CONDUCTOR SIZE DIAGRAM 3 ALCATEL—LUCENT REMOTE RADIO HEAD (RRH) WALL MOUNT 2 RAYCAP DC6-48-60-0-8F DC POWER OVER VOLTAGE PROTECTOR (OVP) 1
DESIGN CONSULTANT
�r / "'",,,,,,,,,`'� AT&T MOBILITY
•:• aRED SANDSTONE ` 4 {�'
<� sIe c � o
inte-grat-ed
DESIGN SERVICES GROUP U ��® - A5
4 Network Solutions COL04025 _ 37
° - DETAILS AND SPECIFICATIONS
2200 E.WILLIAMS FIELD RD, SUITE 200 545 N. FRONTAGE RD. AT&T MOBILITY 0 02/03/15 FINAL CONSTRUCTION DRAWINGS R/JM CP MA ill` a�C
GILBERT, ARIZONA 85295 7025 S. REVERE PKWY VAIL, CO 81 657 188 INVERNESS DRIVE WEST, SUITE 400 N0. DATE REVISIONS BY CHK APP'D ®,4°°°°°°°°°°°° °°®��`' FA NUMBER DRAWING NUMBER REV
OFFICE: (602) 218-8820-FAX(602)218-8820 SUITE 100 ENGLEWOOD, CO 80112 ��''-%,, '9®®/AL,‘ ;,�` ,1,\N.-
CENTENNIAL, CO 80112 SCALE: AS SHOWN DESIGNED BY: RJK DRAWN BY: RJK ti\ 10093722 COL04025—A5 0
6 5 4 3 2 22 x 34 "D" SIZE