Loading...
HomeMy WebLinkAboutB15-0037_A0_8_1425423000.pdf 411,1 OF 1,4 APPROVALS = N • Z idGlo 01, 4 lb Q o 03/03/15 700 BAND AWS BAND 1900 BAND FUTURE SECTOR 1 SECTOR 2 SECTOR 3 SECTOR 1 SECTOR 2 SECTOR 3 SECTOR 1 SECTOR 2 SECTOR 3 SHIELD DRAIN ALPHA (A) BETA (B) GAMMA (C) ALPHA (A) BETA (B) GAMMA (C) ALPHA (A) BETA (B) GAMMA (C) (NOTE 5) TO LTE ALARM 66 BLOCK r r r r r r 0 700k rTO - - . AWS RRH'S w r r r r r r r O TO RACK � o J J z Z J J CC CC Z Z I GND BAR z CO m o o 0 0 m m o o 0 0 1 (2) 6/C DC (NOTE 4) \ \ \ \ \ \ \ \ \ \ \ \ POWER CABLE Y o Y 0 Y 0 Y 0 Y 0 Y 0 M m m m m m m m m m m m TO RACK GND BAR (NOTE 4) 1900 TO r r r r r r t 0 RRH'SI D J Y CC m 0 m Q TO RACK GND BAR 6 AWG � m (NOTE 4) -48V OV 1C3 OV OV CV eY 0 0 0 0 C RTN 0 0 0 0 NO C NC O1 0 O3 O5 O78 910 1 1 12NOTE M7) -48V C) C3 C) C) C) 0 0 0 SUPPLY 0 ----0 �0 ----0 �e �0 �0 �0 �0 0 0 0 4- rn mm mm mm mm mm mm mm \ / V TO 48V DC DISTRIBUTION PANEL NOTES: 1 . SEE SYSTEM DIAGRAM FOR DC POWER CABLE CONDUCTOR SIZES, PAGE A8. 3 2. CABLE TERMINALS FOR POWER CONNECTION SHALL BE COMPRESSION TYPE, 1 -HOLE FOR 1 /4"-20 STUDS. 3. CABLE TERMINAL FOR GROUND CONNECTION SHALL BE COMPRESSION TYPE, 2-HOLE 1 "-CENTERS FOR 1 /4"-20 STUDS. 4. CONNECTIONS TO RACK GROUND BAR SHALL BE MADE WITH 2-HOLE COMPRESSION TERMINALS. 5. WHEN SHIELDED CABLE IS USED, CONNECT CABLE SHIELD DRAIN WIRE TO RACK GROUND BAR. THIS CONNECTION SHALL BE INDEPENDANT OF THE CABLE GROUND WIRE CONNECTION. 6. TURN BACK AND STORE UNUSED CONDUCTORS. 7. INSTALL RAYCAP PROVIDED LOOP-BACK CONNECTOR ON THE LAST ACTIVE (POWERED) MODULE WHEN FEWER THAN 6 RRH's OR RRU's ARE DEPLOYED. CON \ ECT O \ DIAGAV QAC < — IVOU \TE3 SURGE SUPPRESS ON SYSTEv —ALTENATE DC6 - 48 - 60 — � 1v ( 3Y 'AYCAP) A CONNECTION DETAIL 2 NOT USED 1 I DESIGN CONSULTANT / 1:1":" ` "' AT&T MOBILITY <111 •�• RED SANDSTONE 4 ' _ _ M asIe c °° inte-grat-ed ed ' % Ute;00 :IA_ 4 DESIGN SERVICES GROUP C O L04025 Network Solutions RJ 37860 ° = DETAILS AND SPECIFICATIONS 2200 E.WILLIAMS FIELD RD, SUITE 200 545 N. FRONTAGE RD. AT&T MOBILITY 0 02/03/15 FINAL CONSTRUCTION DRAWINGS CP MA =_ ° o GILBERT, ARIZONA 85295 7025 S. REVERE PKWY 188 INVERNESS DRIVE WEST, SUITE 400JM t-;-: 04,o°° °°400,\i;, OFFICE: (602) 218-8820 FAX(602)218-8820 SUITE 100 VAIL, CO 81657 ENGLEWOOD, CO 80112 NO. DATE REVISIONS BY CHK APP'D ,,, 4`.4,,,°°.......°_,a e, FA NUMBER DRAWING NUMBER REV CENTENNIAL, CO 80112 SCALE: AS SHOWN DESIGNED BY: RJK DRAWN BY: RJK '��'%4,0 ,,,,�,im.me""�'1�{ ci,\\ 10093722 COL04025-A6 0 6 5 4 3 2 22 x 34 "D" SIZE