Loading...
HomeMy WebLinkAboutB15-0037_A0_9_1425423000.pdf 411,1 OF kg HI LTE BBU CABLE FIELD–SIDE CABLES APPROVALS4$4011V. NOTE 5 immd (NOTE 3) H FOR ALU CABLE P/N 849097480 "ALARMS" -I / NOTES 6 & 7 ALARM0t( -\ / 0 .:1400o DESCRIPTIONS 1 • ib 0 1,,,2 I)wia03 IP _ NOTES: 3 03/03/15 _ 4 1 . MOUNT 66 BLOCK NEAR EXISTING ALARM BLOCKS. 5 I 2. WIRE TO PROVIDE CONTINUITY WHEN CONDITION IS NORMAL _ 6 —J 3. INSTALL BRIDGING CLIPS AS REQUIRED 4. ALL SPARE, UNUSED CONDUCTORS SHALL BE TURNED BACK AND STORED FOR POSSIBLE FUTURE USE. 5. ALCATEL–LUCENT PRE–ASSEMBLED LTE BBU CABLE SHALL BE USED UNLESS OTHERWISE DIRECTED BY _ 7 THE MARKET. WHEN FIELD ASSEMBLED, THE CABLE SHALL BE 16–TWISTED PAIRS, 24 AWG, SOLID BARE 8 COPPER, SHIELDED UL TYPE CMR/CMG, WITH PVC JACKET. THE BBU END SHALL BE FITTED WITH FOUR RJ-45 PLUGS CONNECTED AS SHOWN 9 _ 6. FIELD–SIDE CABLES SHALL BE TWISTED PAIRS, 24 AWG, SOLID BARE COPPER, UNSHIELDED (PREFERRED) MIN -----= OR SHIELDED. CABLES FOR INDOOR INSTALLATION SHALL BE UL TYPE CMR/CMG, OR CMX WITH PVC 11 JACKET. CABLES FOR OUTDOOR INSTALLATION SHALL BE UL TYPE CMX–OUTDOOR OR MOISTURE RESISTANT. THE NUMBER OF PAIRS SHALL BE AS NECESSARY FOR THE REQUIRED ALARMS. ANSI _ 12 STANDARD COLOR CODE IS SHOWN. APPROVED ALTERNATE COLOR CODE MAY BE USED AND SHALL BE DOCUMENTED ON AS–BUILT DRAWINGS. 13 _ 7. TWO ALU CABLE TYPES MAY BE SUPPLIED; 14 ALU CABLE P/N 849097480, LABELED "ALARMS" AND ALU CABLE P/N 849066840, LABELED "T1 /E1 AND ALARMS". NM15 PUNCH DOWN EITHER CABLE IN STANDARD COLOR CODE SEQUENCE AS SHOWN. ALU ALARM INPUT POINT _ 16 NUMBERS ARE DIFFERENT FOR THE TWO CABLE TYPES. PUNCH DOWN FIELD SIDE AS SHOWN FOR ALU CABLE TYPE FURNISHED FOR THE SITE. _ 17 8. CONTRACTOR TO INSTALL STANDOFF & COVER. (TALLEY PART# 66BLK–KIT OR EQUIVALENT) _ 18 19 * AS REQUIRED 20 - C _ 21 ALU RJ45 ALARM PIN CONNECTIONS _ 22 ALARM PTS PIN (–) PIN (COMMON) 23 1 , 5, 9 & 13 1 2 _ 24 2, 6, 10 & 14 3 6 WIN25 3, 7, 11 & 15 5 4 _ 26 4, 8, 12 & 16 7 8 27 A— WHT/BLU FROM 4528 NOTE 3 �„ on BLUE FROM 50 " RBS DC CONY. MJ (BLU) 29 Ell \ WHT/BLU TO AT–GRADE DC6 BLUE f 6SPD (SEE DETAIL – ,i30 ' RBS LTE RRU AT DC SYS SPD 31 1409, 1409A, I 32 (NOTE 4) 1464, OR 1466) – 33 PLAN _ 34 WIN35 36 3 _ 37 _ 38 _ 39 MINI40 _ 41 _ 42 43 LTE ALAN 3LOC < ASSIG \ VE\TS - ALU WHITE/BLUE TO 27 ABOVE 44 ( \ Ew DC CO \VETE0R EXISTI \ G DC CO \VETE \ OT ALAVED) 45 MN \ \ ---1 WHT/BLU CONVERTER DC MAJOR (45 8c 46) 46 • \ BLU �� 47 INSTALL JUMPERS FROM 46-47 AND 48-49 • \ WHT/OG TO 24-48V 48 �� • \ ORG CONVERTER* CONVERTER DC MINOR (47 8c 48) 49 (SEE DETAIL BLUE TO 28 ABOVE (BLU) \ • \ WHT/GN 1424A) NM LTE BREAKER FAIL (49 8c 50) \ GRN 0FROM DC CONVERTER fl � A E L EVAT I O \ DESIGN CONSULTANT ""`""""'U'��:To:: AT&T MOBILITY lig •:• RED SANDSTONE rasTeC � �� � N4 inte-grat-ed I _ LDESIGN SERVICES GROUP C O L04025 C.) °Network Solutions RJ li 37860 DETAILS AND SPECIFICATIONS 2200 E.WILLIAMS FIELD RD, SUITE 200 545 N. FRONTAGE RD. AT&T MOBILITY 0 02/03/15 FINAL CONSTRUCTION DRAWINGS CP MA ° CC i GILBERT, ARIZONA 85295 7025 S. REVERE PKWY 188 INVERNESS DRIVE WEST, SUITE 400 �®,`°° IQ VAIL, CO 81 657NO. DATE REVISIONS BY CHK APP'D ° '4/ BY FA NUMBER DRAWING NUMBER REV OFFICE: (602)218-8820-FAX(602)218-8820 SUITE 100 ENGLEWOOD, CO 80112 X619,°...„to �,{;,,��,,,,�+�,� °`4 10093722 COL04025–A7 0 CENTENNIAL, CO 80112 SCALE: AS SHOWN DESIGNED BY: RJK DRAWN BY: RJK ti���\ 6 5 4 3 2 22 x M "D" SIZE